Plan Review Details - Permit 20020124
Plan Review Stops For Permit 20020124
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-03-10 Cont ID  
Sent By cpuell Date 2020-03-10 Time 13:44 Rev Time 0.00
Received By cpuell Date 2020-03-10 Time 13:44 Sent To  
Notes
2020-03-10 13:44:54ADDITION IS AN ACCESSORY GARGAE AND STORAGE, DOES NOT
 REQUIRE IT'S OWN ADDRESS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-03-10 Cont ID  
Sent By pvalenti Date 2020-03-10 Time 11:26 Rev Time 0.00
Received By pvalenti Date 2020-03-10 Time 10:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-02-21 Cont ID  
Sent By pvalenti Date 2020-02-21 Time 13:16 Rev Time 0.00
Received By pvalenti Date 2020-02-21 Time 13:16 Sent To  
Notes
2020-02-21 13:19:23PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING APPROVED WITH PROVISO:
  
 1) A SEPARATE PERMIT IS REQUIRED FOR DRIVEWAY.
  
 2) AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-24 Cont ID  
Sent By pvalenti Date 2020-02-24 Time 16:10 Rev Time 0.00
Received By pvalenti Date 2020-02-20 Time 13:01 Sent To  
Notes
2020-02-21 10:36:22***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND BUILDING REVIEW DENIED:
  
 1. OK
  
 2. OK
  
 3. OK
  
 4. OK
  
 5. OK
  
 6. NOTE: PROVIDE A SEPERATE PERMIT FOR DRIVEWAY/PAVER
 WORK.
  
 ADDITIONAL COMMENTS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-19 Cont ID  
Sent By pvalenti Date 2020-02-19 Time 11:02 Rev Time 0.00
Received By pvalenti Date 2020-02-19 Time 08:54 Sent To  
Notes
2020-02-19 11:28:19***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 1. FBC B 107.2.5, PROVIDE A SURVEY AND A SITE-PLAN.
 2. FBC B 107.2.1 PROVIDE DRAINAGE INDICATORS AND
 SET-BACK MEASUREMENTS ON SITE PLAN AND SURVEY.
 3. FBC B 107.1, PROVIDE COMPLETED ENERGY CALCULATIONS.
 4. FBC B 107.1 PROVIDE PRODUCT APPROVALS FOR WINDOWS
 AND DOORS.
 5. FBC B 107.2.1, CLARIFY THE FULL DESCRIPTION OF WORK
 UNDER THIS PERMIT AS THE PLANS SHOW A NEW SECOND FLOOR
 AREA THAT IS NOT INCLUDED IN THE PERMIT APPLICATION
 DESCRIPTION.
 5. NOTE: PROVIDE A SEPERATE PERMIT FOR DRIVEWAY/PAVER
 WORK.
  
 ADDITIONAL COMMENTS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
  
  
  

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2020-04-13 Cont ID  
Sent By jleahy Date 2020-04-13 Time 12:36 Rev Time 0.00
Received By jleahy Date 2020-04-13 Time 12:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2020-04-11 Cont ID  
Sent By jleahy Date 2020-04-11 Time 10:06 Rev Time 0.00
Received By jleahy Date 2020-04-11 Time 10:06 Sent To  
Notes
2020-04-11 10:07:40PLANS TO FUZZY TO READ, NOT SURE WHAT WAS DONE ON
 PAGES. NEED A CLEARER PRODUCT. JLEAHY
  
 I CAN READ THE OLD PAGES NOT THE TWO NEW ONES.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2020-04-02 Cont ID  
Sent By jleahy Date 2020-04-02 Time 16:11 Rev Time 0.00
Received By jleahy Date 2020-04-02 Time 16:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2020-04-02 Cont ID  
Sent By jleahy Date 2020-04-02 Time 14:50 Rev Time 0.00
Received By jleahy Date 2020-04-02 Time 14:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2020-03-27 Cont ID  
Sent By jleahy Date 2020-03-27 Time 16:35 Rev Time 0.00
Received By jleahy Date 2020-03-27 Time 16:35 Sent To  
Notes
2020-03-28 10:07:08ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E.0
  
 1) A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A
 BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE
 FEEDER OR BRANCH CIRCUIT. NEC 225.30
  
 2) PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A
 BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH
 CIRCUIT. NEC 250.32; FBC RE3607.3
  
 3) PLANS ARE NOT SIGNED. PLAN IS REQUIRED TO BE SIGNED
 AND SEALED BY THE DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN. FBC 107.2.1, FS 471, 481
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2020-03-10 Cont ID  
Sent By jleahy Date 2020-03-10 Time 07:42 Rev Time 0.00
Received By jleahy Date 2020-03-10 Time 07:42 Sent To  
Notes
2020-03-10 08:45:27FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 1) ONLY ONE FEEDER AND/OR BRANCH CIRCUIT TO A
 STRUCTURE, PLEASE SHOW HOW THIS PLAN MEETS THE
 REQUIREMENTS FOR 225.30 (A) THRU (E).
 YOU HAVE TWO FEEDERS GOING TO THE MAIN HOUSE FROM THE
 GUEST QUARTERS.
  
 225.30 NUMBER OF SUPPLIES
 A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A
 BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS SHALL BE
 SUPPLIED BY ONLY ONE FEEDER OR BRANCH CIRCUIT UNLESS
 PERMITTED IN 225.30(A) THROUGH (E). FOR THE PURPOSE OF
 THIS SECTION, A MULTIWIRE
 BRANCH CIRCUIT SHALL BE CONSIDERED A SINGLE CIRCUIT.
 WHERE A BRANCH CIRCUIT OR FEEDER ORIGINATES IN THESE
 ADDITIONAL BUILDINGS OR OTHER
 STRUCTURES, ONLY ONE FEEDER OR BRANCH CIRCUIT SHALL BE
 PERMITTED TO SUPPLY POWER BACK TO THE ORIGINAL BUILDING
 OR STRUCTURE, UNLESS
 PERMITTED IN 225.30(A) THROUGH (E).
  
 (A) SPECIAL CONDITIONS. ADDITIONAL FEEDER S OR BRANCH
 CIRCUITS
 SHALL BE PERMITTED TO SUPPLY THE FOLLOWING:
 (1) FIRE PUMPS
 (2) EMERGENCY SYSTEMS
 (3) LEGALLY REQUIRED STANDBY SYSTEMS
 (4) OPTIONAL STANDBY SYSTEMS
 (5) PARALLEL POWER PRODUCTION SYSTEMS
 (6) SYSTEMS DESIGNED FOR CONNECTION TO MULTIPLE SOURCES
 OF
 SUPPLY FOR THE PURPOSE OF ENHANCED RELIABILITY
 (B) SPECIAL OCCUPANCIES. BY SPECIAL PERMISSION,
 ADDITIONAL
 FEEDERS OR BRANCH CIRCUITS SHALL BE PERMITTED FOR
 EITHER OF THE
 FOLLOWING:
 (1) MULTIPLE-OCCUPANCY BUILDINGS WHERE THERE IS NO
 SPACE
 AVAILABLE FOR SUPPLY EQUIPMENT ACCESSIBLE TO ALL
 OCCUPANTS
 (2) A SINGLE BUILDING OR OTHER STRUCTURE SUFFICIENTLY
 LARGE TO
 MAKE TWO OR MORE SUPPLIES NECESSARY
 (C) CAPACITY REQUIREMENTS. ADDITIONAL FEEDERS OR BRANCH
 CIRCUITS SHALL BE PERMITTED WHERE THE CAPACITY
 REQUIREMENTS ARE
 IN EXCESS OF 2000 AMPERES AT A SUPPLY VOLTAGE OF 1000
 VOLTS
 OR LESS.
 (D) DIFFERENT CHARACTERISTICS. ADDITIONAL FEEDERS OR
 BRANCH
 CIRCUITS SHALL BE PERMITTED FOR DIFFERENT VOLTAGES,
 FREQUENCIES, OR
 PHASES OR FOR DIFFERENT USES, SUCH AS CONTROL OF
 OUTSIDE LIGHTING
 FROM MULTIPLE LOCATIONS.
 (E) DOCUMENTED SWITCHING PROCEDURES. ADDITIONAL FEEDERS
 OR
 BRANCH CIRCUITS SHALL BE PERMITTED TO SUPPLY
 INSTALLATIONS UNDER
 SINGLE MANAGEMENT WHERE DOCUMENTED SAFE SWITCHING
 PROCEDURES
 ARE ESTABLISHED AND MAINTAINED FOR DISCONNECTION.
  
 2) SMOKE ALARM/CO COMBONATION IN THE GARAGE PLEASE SHOW
 LISTING FOR THIS LOCATION 110.3
 R314.1.1 LISTINGS.
 SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217.
 COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE
 LISTED IN ACCORDANCE WITH UL 217 AND UL 2034
  
 3) GARAGE DOOR OPENERS NOT SHOWN ON GFCI
 E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES.
 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE RECEPTACLES
 INSTALLED IN GARAGES AND GRADE-LEVEL PORTIONS OF
 UNFINISHED ACCESSORY BUILDINGS
 USED FOR STORAGE OR WORK AREAS SHALL HAVE GROUND-FAULT
 CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL.
 [210.8(A)(2)]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-02-20 Cont ID  
Sent By jleahy Date 2020-02-20 Time 12:02 Rev Time 0.00
Received By jleahy Date 2020-02-20 Time 12:02 Sent To  
Notes
2020-02-20 12:02:30FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) SERVICE SEEMS TO BE LOCATED IN THE BUILDING IN THE
 BACK OF THE LOT, IF SO ONLY ONE FEEDER CAN BE USED TO
 FEED THE HOUSE.PLEASE VERIFY THE LOCATION OF THE
 SERVICE!!!
  
 225.30 A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY
 A BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A
 SERVICE DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY
 ONE FEEDER OR BRANCH CIRCUIT
  
 E3607.3BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) OR
 BRANCH CIRCUIT(S).
 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) OR BRANCH
 CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR
 GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH
 SECTION E3608. THE GROUNDING ELECTRODE CONDUCTOR(S)
 SHALL BE CONNECTED IN A MANNER SPECIFIED IN SECTION
 E3607.3.1 OR, FOR EXISTING PREMISES WIRING SYSTEMS
 ONLY, SECTION E3607.3.2. WHERE THERE IS NO EXISTING
 GROUNDING ELECTRODE, THE GROUNDING ELECTRODE(S)
 REQUIRED IN SECTION E3608 SHALL BE INSTALLED.
 [250.32(A)]
  
 EXCEPTION: A GROUNDING ELECTRODE SHALL NOT BE REQUIRED
 WHERE ONLY ONE BRANCH CIRCUIT, INCLUDING A MULTIWIRE
 BRANCH CIRCUIT, SUPPLIES THE BUILDING OR STRUCTURE AND
 THE BRANCH CIRCUIT INCLUDES AN EQUIPMENT GROUNDING
 CONDUCTOR FOR GROUNDING THE NONCURRENT-CARRYING PARTS
 OF ALL EQUIPMENT. FOR THE PURPOSES OF THIS SECTION, A
 MULTIWIRE BRANCH CIRCUIT SHALL BE CONSIDERED AS A
 SINGLE BRANCH CIRCUIT.
  
 2) SHOW LOCATION OF SERVICE IF SEPARATE FROM THE HOUSE
 YOU WILL NEED TO SEE THE ABOVE COMMENT FOR THE FEEDER.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-02-19 Cont ID  
Sent By jleahy Date 2020-02-19 Time 13:37 Rev Time 0.00
Received By jleahy Date 2020-02-19 Time 10:09 Sent To  
Notes
2020-02-19 13:37:01FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) GARAGE AND STORAGE BUILDING APPEARS TO BE A SEPARATE
 STRUCTURE AND SHALL BE WIRED AS SUCH,
  
 E3607.3BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) OR
 BRANCH CIRCUIT(S).
 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) OR BRANCH
 CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR
 GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH
 SECTION E3608. THE GROUNDING ELECTRODE CONDUCTOR(S)
 SHALL BE CONNECTED IN A MANNER SPECIFIED IN SECTION
 E3607.3.1 OR, FOR EXISTING PREMISES WIRING SYSTEMS
 ONLY, SECTION E3607.3.2. WHERE THERE IS NO EXISTING
 GROUNDING ELECTRODE, THE GROUNDING ELECTRODE(S)
 REQUIRED IN SECTION E3608 SHALL BE INSTALLED.
 [250.32(A)]
  
 EXCEPTION: A GROUNDING ELECTRODE SHALL NOT BE REQUIRED
 WHERE ONLY ONE BRANCH CIRCUIT, INCLUDING A MULTIWIRE
 BRANCH CIRCUIT, SUPPLIES THE BUILDING OR STRUCTURE AND
 THE BRANCH CIRCUIT INCLUDES AN EQUIPMENT GROUNDING
 CONDUCTOR FOR GROUNDING THE NONCURRENT-CARRYING PARTS
 OF ALL EQUIPMENT. FOR THE PURPOSES OF THIS SECTION, A
 MULTIWIRE BRANCH CIRCUIT SHALL BE CONSIDERED AS A
 SINGLE BRANCH CIRCUIT.
  
 2) SHOW LOCATION OF SERVICE IF SEPARATE FROM THE HOUSE
 YOU WILL NEED TO SEE THE ABOVE COMMENT FOR THE MAIN
 HOUSE ALSO.

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-03-10 Cont ID  
Sent By tklarge Date 2020-03-10 Time 11:01 Rev Time 0.00
Received By tklarge Date 2020-03-10 Time 11:01 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-02-21 Cont ID  
Sent By gjohnson Date 2020-02-21 Time 08:48 Rev Time 0.00
Received By gjohnson Date 2020-02-21 Time 08:48 Sent To  
Notes
2020-02-21 08:52:222ND REVIEW: 20020124
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 GAS COMMENTS: YOU MAY REMOVE GAS FROM MASTER AND SUBMIT
 SEPARATELY IN ORDER TO EXPEDITE MASTER PERMIT ISSUANCE.
 CONTACT STEVE KENNEDY
  
 1. SHT. P1 AND P4 SHOWS STEEL GAS PIPING UNDERGROUND
 GALVANIZED STEEL PIPING IS NOT APPROVED FOR UNDERGROUND
 INSTILLATION'S THE MOST COMMON PIPING USED FOR THIS IS
 A POLYETHYLENE PLASTIC PIPE CONFORMING TO ASTM D2513 .
 PER FBC FG 404.11, 403.6
  
 2. SHT. P3 FUEL GAS NOTES #3 GALVANIZED STEEL PIPING IS
 NOT APPROVED FOR UNDERGROUND INSTILLATION'S THE MOST
 COMMON PIPING USED FOR THIS IS A POLYETHYLENE PLASTIC
 PIPE CONFORMING TO ASTM D2513 . PER FBC FG 404.11,
 403.6
  
 3. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2017 FUEL GAS CODE SEC. 304.
  
 4. DRIP LEGS OR DIRT LEGS ARE REQUIRED AT THE GAS
 APPLIANCES PLEASE PROVIDE DETAIL OR SHOW ON THE GAS
 ISOMETRIC. PER FBC FG 408.2, 408.4
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-03-12 Cont ID  
Sent By fmittner Date 2020-03-12 Time 14:30 Rev Time 0.00
Received By fmittner Date 2020-03-12 Time 14:30 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-02-14 Cont ID  
Sent By fmittner Date 2020-02-14 Time 14:38 Rev Time 0.00
Received By fmittner Date 2020-02-14 Time 14:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2020-04-13 Cont ID  
Sent By jleahy Date 2020-04-13 Time 12:37 Rev Time 0.00
Received By jleahy Date 2020-04-13 Time 12:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2020-04-11 Cont ID  
Sent By jleahy Date 2020-04-11 Time 10:08 Rev Time 0.00
Received By jleahy Date 2020-04-10 Time 13:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2020-04-02 Cont ID  
Sent By jleahy Date 2020-04-02 Time 16:11 Rev Time 0.00
Received By jleahy Date 2020-04-02 Time 15:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2020-04-02 Cont ID  
Sent By jleahy Date 2020-04-02 Time 14:54 Rev Time 0.00
Received By jleahy Date 2020-04-02 Time 11:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-03-27 Cont ID  
Sent By jleahy Date 2020-03-27 Time 16:37 Rev Time 0.00
Received By jleahy Date 2020-03-27 Time 14:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-03-13 Cont ID  
Sent By cpuell Date 2020-03-13 Time 13:28 Rev Time 0.00
Received By lmarchan Date 2020-03-09 Time 09:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-02-21 Cont ID  
Sent By lmarchan Date 2020-02-21 Time 14:35 Rev Time 0.00
Received By lmarchan Date 2020-02-20 Time 09:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-19 Cont ID  
Sent By jleahy Date 2020-02-19 Time 13:37 Rev Time 0.00
Received By jleahy Date 2020-02-14 Time 11:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-14 Cont ID  
Sent By shill Date 2020-02-14 Time 16:04 Rev Time 0.00
Received By shill Date 2020-02-10 Time 16:55 Sent To  
Notes
2020-02-14 16:05:24OTHER DEPARTMENT REVIEWS COMPLETE; READY TO ROUTE FOR
 BUILDING DIVISION REVIEW
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2020-02-14 Cont ID  
Sent By lmarchan Date 2020-02-14 Time 09:24 Rev Time 0.00
Received By lmarchan Date 2020-02-14 Time 09:24 Sent To  
Notes
2020-02-05 10:16:42IMPACT FEES PAID ON PAPER - WILL NEED TO CONTACT FOR
 DIGITAL STAMP
 RECEIPT 2020-0205-271 - $21.91 - PAID

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-02-21 Cont ID  
Sent By pvalenti Date 2020-02-21 Time 14:28 Rev Time 0.00
Received By pvalenti Date 2020-02-20 Time 13:01 Sent To  
Notes
2020-02-21 14:31:24PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 PROVIDE MECHANICAL SUB-PERMIT PRIOR TO MECHANICAL WORK.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-02-19 Cont ID  
Sent By pvalenti Date 2020-02-19 Time 13:30 Rev Time 0.00
Received By pvalenti Date 2020-02-19 Time 10:08 Sent To  
Notes
2020-02-19 13:36:23***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW DENIED:
  
 FBC B 107.1, PLEASE PROVIDE A MECHANICAL SUB-PERMIT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-03-10 Cont ID  
Sent By tklarge Date 2020-03-10 Time 11:02 Rev Time 0.00
Received By tklarge Date 2020-03-10 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-02-21 Cont ID  
Sent By gjohnson Date 2020-02-21 Time 08:27 Rev Time 0.00
Received By gjohnson Date 2020-02-21 Time 08:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-02-18 Cont ID  
Sent By gjohnson Date 2020-02-18 Time 15:17 Rev Time 0.00
Received By gjohnson Date 2020-02-18 Time 13:37 Sent To  
Notes
2020-02-18 15:28:171ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE PLUMBING SHEETS DID NOT GET UPLOADED ALL THE P
 SHEETS WERE THE CSO.00 SHEET THAT HAD THE PRIVATE
 PROVIDER AND COUNTY STAMP ON IT PLEASE PROVIDE THE
 PLUMBING SHEETS LISTED IN THE SHEET INDEX. PER WPB
 AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 7 Status P Date 2020-04-13 Cont ID  
Sent By jleahy Date 2020-04-13 Time 12:37 Rev Time 0.00
Received By jleahy Date 2020-04-13 Time 12:37 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 6 Status P Date 2020-04-10 Cont ID  
Sent By shill Date 2020-04-10 Time 16:38 Rev Time 0.00
Received By shill Date 2020-04-10 Time 16:38 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status F Date 2020-04-10 Cont ID  
Sent By shill Date 2020-04-10 Time 14:17 Rev Time 0.00
Received By shill Date 2020-04-10 Time 14:03 Sent To  
Notes
2020-04-10 14:22:39SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SOME OF THE PAGES LACK THE PRIVATE PROVIDER STAMP.
 EITHER PROVIDE STAMPED PAGES OR REVISE THE AFFIDAVIT(S)
 TO REFER TO THE PAGE VERSION. FOR EXAMPLE, THE
 AFFIDAVIT FOR E-1 COULD BE REVISED TO STATE "E-1
 REVISION 2 DATED 3/26/20". TO KNOW WHICH VERSION WAS
 REVIEWED WE NEED EITHER A STAMPED PLAN OR AN AFFIDAVIT
 WHICH IS CLEAR.
  
  
  
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status F Date 2020-04-03 Cont ID  
Sent By shill Date 2020-04-03 Time 07:31 Rev Time 0.00
Received By shill Date 2020-04-03 Time 07:31 Sent To  
Notes
2020-04-03 07:33:02****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THE PRIVATE PROVIDER AFFIDAVIT DOES NOT INCLUDE ALL
 VERSIONS OF ALL PAGES THAT THEY REVIEWED. PROVIDE AN
 UPDATED AFFIDAVIT AND PROVIDE PAGES WITH THEIR REVIEW
 STAMPS. PLEASE UPLOAD AS A SINGLE PDF TO THE SUPPORTING
 DOCS FILE.
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2020-03-10 Cont ID  
Sent By pvalenti Date 2020-03-10 Time 11:26 Rev Time 0.00
Received By pvalenti Date 2020-03-10 Time 10:40 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2020-02-24 Cont ID  
Sent By pvalenti Date 2020-02-24 Time 16:24 Rev Time 0.00
Received By pvalenti Date 2020-02-24 Time 16:24 Sent To  
Notes
2020-02-24 16:28:30***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND PRIVATE PROVIDER REVIEW DENIED:
  
 WHEN SUBMITTING THE PRIVATE PROVIDER AFFIDAVIT, PLEASE
 INCLUDE THE ARCHITECT'S REVISION DATES.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2020-02-13 Cont ID  
Sent By shill Date 2020-02-13 Time 14:58 Rev Time 0.00
Received By shill Date 2020-02-13 Time 14:58 Sent To  
Notes
2020-02-13 15:06:40****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PLANS WERE UPLOADED AS PNG FILES AND ARE NOT
 LEGIBLE. SEE PROJECTDOX QUICKSTART GUIDE; PLANS ARE TO
 BE IN PDF FORM.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2020-03-10 Cont ID  
Sent By pvalenti Date 2020-03-10 Time 11:21 Rev Time 0.00
Received By pvalenti Date 2020-03-10 Time 10:40 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2020-02-21 Cont ID  
Sent By pvalenti Date 2020-02-21 Time 09:44 Rev Time 0.00
Received By pvalenti Date 2020-02-20 Time 13:01 Sent To  
Notes
2020-02-21 09:45:55***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ROOFING STOP DENIED:
  
 FBC B 107.1, PLEASE PROVIDE THE PRODUCT APPROVALS FOR
 ALL ROOFING MATERIAL.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-02-19 Cont ID  
Sent By pvalenti Date 2020-02-19 Time 10:35 Rev Time 0.00
Received By pvalenti Date 2020-02-19 Time 10:08 Sent To  
Notes
2020-02-19 10:41:17***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ROOFING REVIEW DENIED:
  
 1. FBC B 107.1, PROVIDE THE PRODUCT APPROVALS FOR ALL
 ROOFING MATERIALS.
 2. A ROOFING SUB-PERMIT IS REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2020-04-13 Cont ID  
Sent By shill Date 2020-04-13 Time 14:29 Rev Time 0.00
Received By shill Date 2020-04-13 Time 14:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-04-13 Cont ID  
Sent By jleahy Date 2020-04-13 Time 15:16 Rev Time 0.00
Received By jleahy Date 2020-04-13 Time 15:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2020-04-10 Cont ID  
Sent By shill Date 2020-04-10 Time 14:23 Rev Time 0.00
Received By shill Date 2020-04-10 Time 14:22 Sent To  
Notes
2020-04-10 14:26:07SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FS471, PROVIDE EITHER PAPER ORIGINALS OR DIGITALLY
 SIGNED PDFS FOR THE FOLLOWING PAGES:
  
 E0, E1.1, E1, E2, P1, P3, P4
  
 PAPER ORIGINALS WERE SUBMITTED AT TIME OF FIRST
 SUBMISSION BUT THESE PAGES HAVE CHANGED.
  
 PDFS ARE PREFERABLE; THE GOAL IS THAT THEY WILL BE
 REVIEWED IMMEDIATELY UPON RECEIPT.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2020-04-03 Cont ID  
Sent By shill Date 2020-04-03 Time 07:30 Rev Time 0.00
Received By shill Date 2020-04-03 Time 07:20 Sent To  
Notes
2020-04-03 07:31:22****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 SEND DIGITALLY SIGNED PDFS TO [email protected], CC
 [email protected].
  
 NONE OF THE DOCUMENTS WERE DIGITALLY SIGNED BUT IT'S MY
 UNDERSTANDING THAT THEY ALL HAVE A DIGITAL SIGNATURE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-03-27 Cont ID  
Sent By jleahy Date 2020-03-27 Time 16:36 Rev Time 0.00
Received By jleahy Date 2020-03-27 Time 16:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-02-14 Cont ID  
Sent By pvalenti Date 2020-02-14 Time 10:33 Rev Time 0.00
Received By shill Date 2020-02-14 Time 10:33 Sent To  
Notes
2020-02-14 10:34:03AFTER ALL REVIEWS HAVE PASSED, ONE ORIGINAL WILL BE
 REQUIRED. ONE ORIGINAL PAPER SIGNED & SEALED DOCUMENT
 WAS SUBMITTED, BUT WILL NOT BE COMPARED TO THE
 PROJECTDOX FILES UNTIL AFTER ALL REVIEWS HAVE PASSED.
  
2020-02-05 10:12:152/5/20 HARD COPY SET OF PLANS, PRODUCT APPROVALS, CALCS
 LOCATED IN LIBRARY. LEM

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-12 Cont ID  
Sent By fmittner Date 2020-03-12 Time 14:30 Rev Time 0.00
Received By fmittner Date 2020-03-12 Time 14:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-02-14 Cont ID  
Sent By fmittner Date 2020-02-14 Time 14:38 Rev Time 0.00
Received By fmittner Date 2020-02-14 Time 14:38 Sent To  
Notes
***NONE***