Plan Review Details - Permit 20020004
Plan Review Stops For Permit 20020004
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2020-05-08 Cont ID  
Sent By cpuell Date 2020-05-08 Time 16:10 Rev Time 0.00
Received By cpuell Date 2020-05-08 Time 16:10 Sent To  
Notes
2020-05-08 16:10:22ADDRESS CHANGED FROM 625 S OLIVE TO 695 S OLIVE. CP

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2020-04-20 Cont ID  
Sent By cpuell Date 2020-04-20 Time 15:32 Rev Time 0.00
Received By cpuell Date 2020-04-20 Time 15:32 Sent To  
Notes
2020-04-20 15:32:30FOR THE FOUNDATION PERMIT, THE BUILDING ADDRESS NEEDS
 TO BE CHANGED, PLEASE CONTACT [email protected] TO
 DISCUSS. PLEASE SEE BELOW FOR BUILDING PERMIT COMMENTS:
 NEED SEPARATE ADDRESS FOR PET SPA ON TANGLEWOOD, FOR
 THE 3 SUITE/RESTRAUNT SPACES ON SOUTH OLIVE AND FOR THE
 ACTUAL BUILDING ITSLF WHICH WILL BE BASED ON THE
 LOVCATION OF THE LOBBY/LEASING OFFICE/ MAILROOM. PLEASE
 CONTACT [email protected] TO DISCUSS POSSIBLE OPTIONS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-02-18 Cont ID  
Sent By cpuell Date 2020-02-18 Time 16:52 Rev Time 0.00
Received By cpuell Date 2020-02-18 Time 16:52 Sent To  
Notes
2020-02-18 16:53:05CONTACTED CUSTOMER TO ADDRESS ADDRESSING ISSUES,
 WAITING TO HEAR BACK.
  
 PLEASE CONTACT [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-05-29 Cont ID  
Sent By rmcdouga Date 2020-05-29 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2020-05-29 Time 11:21 Sent To  
Notes
2020-05-29 11:21:48FOUNDATION ONLY
 BUILDING PROVISO ITEMS
 1) THE SOIL BEARING CAPACITY OF 8,000 PSF IS REQUIRED
 TO BE VERIFIED PRIOR TO VERTICAL CONSTRUCTION.
 2) THIS FOUNDATION PERMIT IS BEING APPLIED FOR UNDER
 SECTION 105.13 OF THE CITY OF WEST PALM BEACH
 AMENDMENTS TO THE 2017 FBC. THE HOLDER OF THIS
 FOUNDATION PERMIT SHALL PROCEED AT THE HOLDER'S OWN
 RISK WITH THE BUILDING OPERATION AND WITHOUT ASSURANCE
 THAT A PERMIT FOR THE ENTIRE STRUCTURE WILL BE GRANTED.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-04-17 Cont ID  
Sent By rmcdouga Date 2020-04-17 Time 11:56 Rev Time 0.00
Received By rmcdouga Date 2020-04-17 Time 06:47 Sent To  
Notes
2020-04-17 06:49:53PLAN REVIEW COMMENTS
 FOUNDATION ONLY PERMIT
 625 S. OLIVE AVE.
 PERMIT #20020004
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) WILL BE ADDRESSED PRIOR TO RECEIVING C.O. (ART IN
 PUBLIC PLACES)
  
 2) THE THRESHOLD AGREEMENT IS NOT COMPLETE. THE
 ENGINEER AND INSPECTOR'S RESUMES ARE REQUIRED TO BE
 SUBMITTED FOR THE RECORD. THE CONTRACTOR'S AND OWNER'S
 NOTARIZED AFFIDAVITS WERE NOT BEEN SUBMITTED. THRESHOLD
 BUILDING / FL S. S. 553.71(7)
  
 3) THE SOIL BEARING CAPACITY OF 8,000 PSF IS REQUIRED
 TO BE VERIFIED PRIOR TO VERTICAL CONSTRUCTION.
  
 4) COMPLIED.
  
 5) NOT ADDRESSED. BASED ON THE SIZE OF THE ELEVATOR
 HOISTWAYS, IT DOES NOT APPEAR THAT THE INSIDE OF THE
 ELEVATOR CAR WILL LARGE ENOUGH TO ACCOMMODATE THE
 REQUIRED STRETCHER. PROVIDE A DIMENSIONED ELEVATOR CAR
 FLOOR PLAN SHOWING THE STRETCHER CLEARANCES. (ORIGINAL
 COMMENT FOLLOWS.) FBC 3002.4 REQUIRES ANY BUILDING THAT
 IS MORE THAN THREE STORIES HIGH OR IN WHICH THE
 VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL LANDING
 AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET TO BE
 CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER ELEVATOR
 THAT IS OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE
 DEPARTMENT ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL
 BE OF A SIZE AND ARRANGEMENT TO ACCOMMODATE AN
 AMBULANCE STRETCHER 24 INCHES BY 76 INCHES WITH NOT
 LESS THAN 5-INCH RADIUS CORNERS, IN THE HORIZONTAL,
 OPEN POSITION AND SHALL BE IDENTIFIED BY THE
 INTERNATIONAL SYMBOL FOR EMERGENCY MEDICAL SERVICES
 (STAR OF LIFE).
  
 6) NOT ADDRESSED. THIS ITEM CAN BE ADDRESSED WITH THE
 SHELL PERMIT. (ORIGINAL COMMENT FOLLOWS.) THE TRASH
 CHUTE DISCHARGE ROOM IS REQUIRED TO BE SEPARATED BY
 FIRE BARRIERS WITH A FIRE-RESISTANCE RATING NOT LESS
 THAN THE REQUIRED FIRE RATING OF THE SHAFT ENCLOSURE.
 FBC 713.13.4
  
 7) COMPLIED.
  
 8) NO RESPONSE IN COMMENTS. (ORIGINAL COMMENT FOLLOWS.)
 PLEASE REVIEW THE ELEVATIONS AROUND THE EXTERIOR OF THE
 BUILDING AND COMPARE THEM WITH THE FLOOR ELEVATION
 (11.97') OF THE BUILDING TO MAKE SURE THAT THE EXITS
 DISCHARGE AT GRADE AND THE ELEVATIONS AND SLOPES OF
 LANDINGS AND WALK WAYS WILL MEET THE RUNNING SLOPE AND
 CROSS SLOPE REQUIREMENTS OF THE FLORIDA ACCESSIBILITY
 CODE SECTION 403.
  
 9) THIS WILL BE A PROVISO ITEM. (ORIGINAL COMMENT
 FOLLOWS.) THIS FOUNDATION PERMIT IS BEING APPLIED FOR
 UNDER SECTION 105.13 OF THE CITY OF WEST PALM BEACH
 AMENDMENTS TO THE 2017 FBC. THE HOLDER OF THIS
 FOUNDATION PERMIT SHALL PROCEED AT THE HOLDER'S OWN
 RISK WITH THE BUILDING OPERATION AND WITHOUT ASSURANCE
 THAT A PERMIT FOR THE ENTIRE STRUCTURE WILL BE GRANTED.
  
 10) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-03-04 Cont ID  
Sent By rmcdouga Date 2020-03-04 Time 11:29 Rev Time 0.00
Received By rmcdouga Date 2020-03-03 Time 18:58 Sent To  
Notes
2020-03-04 08:33:56PLAN REVIEW COMMENTS
 FOUNDATION ONLY PERMIT
 625 S. OLIVE AVE.
 PERMIT #20020004
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ART IN PUBLIC PLACES
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. PER
 CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND CITY
 OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, ART
 IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST. PER CITY OF WEST PALM BEACH
 CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES,
 SECTION 78-122, RENOVATION AND NEW CONSTRUCTION
 PROJECTS ARE ASSESSED CUMULATIVELY, SO THE ART
 ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE PROJECTS.
 FOR INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR AT
 822-1515 OR E-MAIL: [email protected]
  
 2) THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN
 (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
 A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION
 PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
 B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5)
 FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY
 THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED
 TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED
 AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED
 BEFORE PERMIT ISSUANCE WILL TAKE PLACE.
 C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF
 RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM
 BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS
 AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633 FLORIDA STATUTES.
 D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN
 INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
 E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
 F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE,
 PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING
 ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE
 APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR
 PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN
 COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR
 THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE
 IN BLACK & WHITE.
 G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES,
 PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT
 AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING
 DOCUMENTS BY THE CONTRACTOR.
 H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL
 BUILDING INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6
 MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY.
 I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR
 THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS
 REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL,
 APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND
 CEILINGS.
 J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL
 BE HAPPY TO SEND YOU A COPY OF THE CURRENT ( OCTOBER
 2018 ) CITY GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT
 INSPECTORS.
  
 3) THE GEOTECHNICAL REPORT THAT WAS SUBMITTED INDICATES
 THAT THE RECOMMENDED VIBRO COMPACTION SOIL PREPARATION
 WILL PRODUCE A SOIL BEARING VALUE OF UP TO 6,000 PSF.
 NOTE 3A ON SHEET S200 OF THE PLANS STATES THAT THE
 BUILDING DESIGN REQUIRES A SOIL BEARING CAPACITY OF
 8,000 PSF. PLEASE INDICATE HOW THIS WILL BE ADDRESSED.
 FBC 1801.2
  
 4) SPECIFY HOW COMPLIANCE WITH FBC CHAPTER 33
 SAFEGUARDS DURING CONSTRUCTION FOR THE FOUNDATION
 PERMIT WILL BE MET.
  
 5) FBC 3002.4 REQUIRES ANY BUILDING THAT IS MORE THAN
 THREE STORIES HIGH OR IN WHICH THE VERTICAL DISTANCE
 BETWEEN THE BOTTOM TERMINAL LANDING AND THE TOP
 TERMINAL LANDING EXCEEDS 25 FEET TO BE CONSTRUCTED TO
 CONTAIN AT LEAST ONE PASSENGER ELEVATOR THAT IS
 OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE DEPARTMENT
 ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL BE OF A
 SIZE AND ARRANGEMENT TO ACCOMMODATE AN AMBULANCE
 STRETCHER 24 INCHES BY 76 INCHES WITH NOT LESS THAN
 5-INCH RADIUS CORNERS, IN THE HORIZONTAL, OPEN POSITION
 AND SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL FOR
 EMERENCY MEDICAL SERVICES (STAR OF LIFE).
  
 6) THE TRASH CHUTE DISCHARGE ROOM IS REQUIRED TO BE
 SEPARATED BY FIRE BARRIERS WITH A FIRE-RESISTANCE
 RATING NOT LESS THAN THE REQUIRED FIRE RATING OF THE
 SHAFT ENCLOSURE. FBC 713.13.4
  
 7) THE EXIT PASSAGEWAY AT STAIR 01 IS INCORRECTLY
 LABELED AS AN EXIT ACCESS CORRIDOR. AN EXIT PASSAGEWAY
 IS AN EXTENSION OF THE ENCLOSED INTERIOR EXIT STAIRWAY
 AND HAS REQUIREMENTS SIMILAR TO THE STAIRWAY. PLEASE
 CORRECT. SEE FBC 1023.1 AND 1024.
  
 8) PLEASE REVIEW THE ELEVATIONS AROUND THE EXTERIOR OF
 THE BUILDING AND COMPARE THEM WITH THE FLOOR ELEVATION
 (11.97') OF THE BUILDING TO MAKE SURE THAT THE EXITS
 DISCHARGE AT GRADE AND THE ELEVATIONS AND SLOPES OF
 LANDINGS AND WALK WAYS WILL MEET THE RUNNING SLOPE AND
 CROSS SLOPE REQUIREMENTS OF THE FLORIDA ACCESSIBILITY
 CODE SECTION 403.
  
 9) THIS FOUNDATION PERMIT IS BEING APPLIED FOR UNDER
 SECTION 105.13 OF THE CITY OF WEST PALM BEACH
 AMENDMENTS TO THE 2017 FBC. THE HOLDER OF THIS
 FOUNDATION PERMIT SHALL PROCEED AT THE HOLDER'S OWN
 RISK WITH THE BUILDING OPERATION AND WITHOUT ASSURANCE
 THAT A PERMIT FOR THE ENTIRE STRUCTURE WILL BE GRANTED.
  
 10) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-20 Cont ID  
Sent By jleahy Date 2020-04-17 Time 14:57 Rev Time 0.00
Received By jleahy Date 2020-04-17 Time 14:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-03-04 Cont ID  
Sent By jleahy Date 2020-03-04 Time 08:59 Rev Time 0.00
Received By jleahy Date 2020-03-04 Time 08:14 Sent To  
Notes
2020-03-04 09:07:27FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) MP IS IT A MAIN OR MLO?, MHP IS IT A MAIN OR MLO?,
 MAIN DIST. SEC (6000A) #1 HOW MANY MAINS?
  
 2) GROUNDING ELECTRODES COMMON 250.58
  
 3) CANNOT DETERMINE IF THE SERVICE MEETS THE CODE OR IF
 IT HAS ADEQUATE CAPACITY. NEED MORE INFORMATION.
  
 4) FIRE PUMP SHOWN ON PLANS BUT NOT ON RISER?
  
 5) IS THERE A GENERATOR?

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2020-06-01 Cont ID  
Sent By rrossano Date 2020-06-01 Time   Rev Time 0.00
Received By rrossano Date 2020-06-01 Time   Sent To ENG
Notes
2020-06-01 15:55:24REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL E20020018.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2020-04-20 Cont ID  
Sent By rrossano Date 2020-04-20 Time   Rev Time 0.00
Received By rrossano Date 2020-04-20 Time   Sent To  
Notes
2020-04-20 12:46:10PLEASE ADDRESS BUILDING COMMENTS.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-03-11 Cont ID  
Sent By shill Date 2020-03-11 Time 18:57 Rev Time 0.00
Received By shill Date 2020-03-11 Time 18:57 Sent To  
Notes
2020-03-11 18:58:22CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-04-17 Cont ID  
Sent By pleduc Date 2020-04-17 Time   Rev Time 0.00
Received By pleduc Date 2020-04-17 Time 10:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-02-24 Cont ID  
Sent By pleduc Date 2020-02-24 Time   Rev Time 0.00
Received By pleduc Date 2020-02-21 Time 09:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-06-08 Cont ID  
Sent By lmarchan Date 2020-06-08 Time 13:12 Rev Time 0.00
Received By lmarchan Date 2020-05-28 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-04-22 Cont ID  
Sent By lmarchan Date 2020-04-22 Time 15:30 Rev Time 0.00
Received By lmarchan Date 2020-03-29 Time 15:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-03-11 Cont ID  
Sent By shill Date 2020-03-11 Time 18:58 Rev Time 0.00
Received By shill Date 2020-02-19 Time 07:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2020-05-29 Cont ID  
Sent By rmcdouga Date 2020-05-29 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2020-05-29 Time 10:22 Sent To  
Notes
2020-05-29 10:28:05PALM BEACH COUNTY HAS AGREED TO DEFER THE IMPACT FEE
 REVIEW AND PAYMENT UNTIL THE PERMIT FOR THE VERTICAL
 CONSTRUCTION PERMIT #20011267 IS READY TO BE ISSUED.
 EMAIL FROM WILLIE SWOOPE DATED 5/28/2020.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-03-03 Cont ID  
Sent By rmcdouga Date 2020-03-03 Time 18:48 Rev Time 0.00
Received By rmcdouga Date 2020-03-03 Time 18:48 Sent To  
Notes
2020-03-03 18:58:26PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 IF YOU WISH TO DEFER THIS REQUIREMENT UNTIL THE PERMIT
 TO BEGIN VERTICAL CONSTRUCTION IS READY TO BE ISSUED,
 SUBMIT A LETTER TO THE BUILDING OFFICIAL REQUESTING
 SUCH. THE BUILDING OFFICIAL WILL MAKE THE DETERMINATION
 IF THE FOUNDATION ONLY PERMIT WILL BE ISSUED.
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-06-10 Cont ID  
Sent By ccole Date 2020-06-10 Time 12:58 Rev Time 0.00
Received By ccole Date 2020-06-05 Time 15:37 Sent To  
Notes
2020-06-10 08:01:48PLUMBING PROVISOS:
  
 1) PLUMBING APPROVAL IS FOR UNDERSLAB PLUMBING ONLY.
  
 SEPARATE PERMITS ARE REQUIRED FOR THE GREASE
 INTERCEPTORS, BACKFLOW PREVENTER, GAS PIPING, FIRE
 LINE, AND FOR THE MAIN BUILDING PLUMBING SYSTEMS.
  
 2) A REVISION TO THE FOUNDATION PERMIT IS REQUIRED TO
 PROVIDE THE REQUIRED ACCESSIBLE DRINKING FOUNTAINS IN
 THE 1ST FLOOR BUSINESS OCCUPANCY.
 NO PLUMBING INSPECTIONS WILL BE PERFORMED UNTIL THE
 REVISON IS SUBMITTED AND APPROVED.
  
 CCOLE- 6/10/2020
2020-06-08 12:58:42 
 3RD REVIEW FBC-2017 PLUMBING
 PERMIT #20020004
 6/8/20
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE REQUIRED DRINKING FOUNTAINS IN THE BUSINESS
 OCCUPANCY ON THE 1ST FLOOR WERE NOT PROVIDED. A WATER
 COOLER CANNOT REPLACE THE REQUIRED ACCESSIBLE DRINKING
 FOUNTAINS PER SECTION 211.2 AND 211.3 FBC ACC.
  
 211.2 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 PLEASE SEE SECTIONS 602.1- 602.7 FBC ACC AND REVISE THE
 DRAWINGS.
  
 2) COMMENT #9 PRINTED BELOW IS PASSED WITH PROVISO FOR
 A SEPARATE PERMIT TO BE OBTAINED FOR THE GREASE
 INTERCEPTORS PRIOR TO INSTALLATION BELOW THE FOUNDATION
 SLAB.
 9) P1.00B GREASE INTERCEPTORS: REFER TO SECTION 8.3.1
 PDI G101 AND INDICATE IN THE NOTE THE 1/4" PER FT.
 SLOPES OF THE GREASE WASTE PIPES. PLEASE NOTE THAT IN
 ACCORDANCE WITH THIS SECTION, THE INTERCEPTOR MUST BE
 SIZED AT A MINIMUM FLOW RATE OF 75 GPM @ 2 MINUTES
 DRAIN TIME. A) SHOW THE LOCATIONS OF STUB UPS FOR THE
 INTERCEPTOR VENTS, SAMPLE PORTS, CLEANOUTS, AND AIR
 INTAKES- SECTION 107.2.1. B) SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE SELECTED INTERCEPTORS- SEE
 SECTION 1003.3.4 FBC P FOR ACCEPTABLE APPROVAL
 STANDARDS. C) PROVIDE AN ENLARGED INSTALLATION DETAIL
 ON THE PLANS. PLEASE NOTE THAT THE INTERCEPTORS SHALL
 BE INSTALLED PER MANUFACTURER'S GUIDELINES AND SHALL BE
 APPROVED FOR INSTALLATION BY THE CITY OF WEST PALM
 BEACH UTILITIES DEPARTMENT. PLEASE CONTACT CHIEF
 PLUMBING INSPECTOR TIMOTHY LARGE FOR MORE INFORMATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBINGPLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-04-21 Cont ID  
Sent By ccole Date 2020-04-21 Time 12:29 Rev Time 0.00
Received By ccole Date 2020-04-20 Time 13:50 Sent To  
Notes
2020-04-21 12:30:122ND REVIEW FBC-2017 PLUMBING
 PERMIT #20020004
 4/21/20
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 PLEASE NOTE THAT THERE ARE NO SITE OR CIVIL PLANS
 INCLUDED IN THE PLAN SET TO INDICATE LOCATIONS OF
 UTILITY ENTRANCES AND MAIN SANITARY AND STORM DRAINAGE
 CONNECTIONS TO THE CITY SERVICES.
  
 1) PLEASE CHOOSE A PLAN SHEET RELATIVE TO THE PLUMBING
 PORTION OF THE PROPOSED PROJECT AND PROVIDE A DETAILED
 SCOPE OF WORK OUTLINE INDICATING THE LIMITATION OF
 PLUMBING WORK TO BE PERFORMED UNDER THIS FOUNDATION
 ONLY PERMIT. THIS CAN ALSO BE PROVIDED AS A DOCUMENT-
 SECTION 107.2.1 WPB. INDICATE WHICH SHEETS ARE TO BE
 INCLUDED THE SCOPE AND MARK ALL OTHERS AS "FOR
 REFERENCE ONLY".
  
 2) SHEETS CD-01, A1.01. A1.01A: THE OCCUPANT LOAD
 CALCULATIONS ON THE PLANS FOR THE BUSINESS AREAS DO NOT
 INCLUDE THE SEATING CALCULATIONS FOR THE COFFEE BAR-
 SEE MAIN PERMIT PLANS UNDER #20011267. THIS AREA IS
 CALCULATED AT 15 NET PERSONS PER SQ. FT.- TABLE
 1004.1.2 FBC B. PLEASE CORRECT THE CALCULATIONS-
 SECTION 107.2.1 WPB.
  
 3) SHEETS CD-01, A1.01, A1.0A, P1.00A: REFER TO TABLE
 403.3 FBC P AND PROVIDE A SCHEDULE ON THE PLAN SHOWING
 THE MINIMUM REQUIRED PLUMBING FIXTURES REQUIRED AND THE
 FIXTURES PROVIDED. CHOOSE ANY RELEVANT SHEET TO PROVIDE
 THE SCHEDULE. PLEASE NOTE THAT SEPARATE TOILET
 FACILITIES FOR MALE AND FEMALE USE ARE REQUIRED IN
 BUSINESS OCCUPANCIES, AND A DRINKING FOUNTAIN AND A
 SERVICE SINK. REVISE THE DRAWINGS TO SHOW THE LOCATIONS
 OF THE REQUIRED FIXTURES AND PLUMBING PIPING
 REQUIREMENTS- SECTION 107.2.1 WPB.
  
 4) SHEET CD-03: THE PLUMBING FIXTURES REQUIRED IN THE
 BUSINESS AREA ARE DESIGNATED FOR PUBLIC USE AND SHALL
 BE INSTALLED IN COMPLIANCE WITH THE FLORIDA
 ACCESSIBILITY CODE SIXTH EDITION 2017- PLEASE CORRECT
 THE REFERENCE TO THE 2010 ADA. ALSO CORRECT THE
 REFERENCE TO FHA TO INCLUDE "PUBLIC AND COMMON USE
 FACILITIES". A) PLEASE REPLACE ALL TYPICAL FIGURES
 SHOWN ON THE PLAN FOR PUBLIC USE WITH THE TYPICAL
 FIGURES SHOWN IN THE FBC ACC. B) PROVIDE TYPICAL
 FIGURES RELEVANT TO FAIR HOUSING COMPLIANCE FROM THE
 FAIR HOUSING ACT DESIGN MANUAL.
  
 5) PROVIDE PROJECT SPECIFIC ENLARGED AND DIMENSIONED
 DRAWINGS FOR THE PUBLIC AND COMMON USE TOILET ROOMS ON
 THE 1ST FLOOR THAT INDICATE ALL ACCESSIBLE FIXTURE AND
 ACCESSORY INSTALLATION AND CLEARANCE REQUIREMENTS IN
 ACCORDANCE WITH CHAPTER 6 OF THE FBC ACC. PLEASE
 INCLUDE DIMENSIONED ELEVATION VIEWS AND DIAGRAMS
 SHOWING COMPLIANCE. PLEASE NOTE THAT COMPLETE
 ACCESSIBILITY DETAILS FOR THE 1ST FLOOR INCLUDING THE
 COFFEE BAR MAY BE DEFERRED AT THIS TIME, HOWEVER IT IS
 NOT CLEAR AS THE EXTENT OF WORK TO BE COVERED UNDER
 THIS FOUNDATION PERMIT- SEE COMMENT #1 ABOVE.
  
 6) P1.00A & P100B: INDICATE PIPE MATERIALS FOR THE
 SANITARY SEWER, DWV, GREASE WASTE LINE, AND WATER
 SERVICE- TABLES 605.3, 702.1, 702.2, 702.3 FBC P.
 PROVIDE A SUBMITTAL PACKAGE FOR ALL MATERIALS
 SPECIFIED- SECTION 107.2.1 WPB.
  
 7) P1.00A: INDICATE HOW THE MAIN 6" WATER LINE WILL BE
 PROTECTED FROM CORROSION AND STRESS AND STRAIN-
 SECTIONS 305.1, 305.1.1 AND 305.2 FBC P. PROVIDE
 SLEEVING DETAILS WHERE REQUIRED.
  
 8) P1.00A & B: PROVIDE MANHOLE INSTALLATION DETAILS AND
 SHOW THEIR LOCATIONS ON THE MAIN 1ST FLOOR PLAN (SHEET
 A1.01). INDICATE THEY WILL BE EQUIPPED WITH GAS-TIGHT
 COVERS- SECTION 708.1.7 FBC P.
  
 9) P1.00B GREASE INTERCEPTORS: REFER TO SECTION 8.3.1
 PDI G101 AND INDICATE IN THE NOTE THE 1/4" PER FT.
 SLOPES OF THE GREASE WASTE PIPES. PLEASE NOTE THAT IN
 ACCORDANCE WITH THIS SECTION, THE INTERCEPTOR MUST BE
 SIZED AT A MINIMUM FLOW RATE OF 75 GPM @ 2 MINUTES
 DRAIN TIME. A) SHOW THE LOCATIONS OF STUB UPS FOR THE
 INTERCEPTOR VENTS, SAMPLE PORTS, CLEANOUTS, AND AIR
 INTAKES- SECTION 107.2.1. B) SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE SELECTED INTERCEPTORS- SEE
 SECTION 1003.3.4 FBC P FOR ACCEPTABLE APPROVAL
 STANDARDS. C) PROVIDE AN ENLARGED INSTALLATION DETAIL
 ON THE PLANS. PLEASE NOTE THAT THE INTERCEPTORS SHALL
 BE INSTALLED PER MANUFACTURER'S GUIDELINES AND SHALL BE
 APPROVED FOR INSTALLATION BY THE CITY OF WEST PALM
 BEACH UTILITIES DEPARTMENT. PLEASE CONTACT CHIEF
 PLUMBING INSPECTOR TIMOTHY LARGE FOR MORE INFORMATION.
  
 10) P1.00 A & B, & P6.01: INDICATE HOW THE WATER
 SERVICE LINE AND BOOSTER PUMP WERE SIZED. PROVIDE
 CALCULATIONS- SECTION 604.1 FBC P.
  
 11) P1.00 A & B, & P6.02: PROVIDE DRAINAGE AND SEWER
 SYSTEM SIZING CALCULATIONS- TABLE 710.1(1) FBC P.
  
 12) P1.00 A & B: PROVIDE STORM DRAINAGE CALCULATIONS IN
 ACCORDANCE WITH SECTION 1106.1 & TABLES 1106.2 & 1106.3
 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-03-02 Cont ID  
Sent By shill Date 2020-03-02 Time 18:27 Rev Time 0.00
Received By shill Date 2020-03-02 Time 18:27 Sent To  
Notes
2020-03-02 18:27:51PLUMBING 1ST REVIEW**DENIED**2002004
  
 1) PROVIDE FLOOR PLAN SHOWING ALL 1ST FLOOR ROOM
 DIMENSIONS. FBC 107.3.5
 2) PROVIDE OCCUPANCY AND OCCUPANT LOAD FOR THE 1ST
 FLOOR. I WAS ONLY ABLE TO LOCATE 1 TOILET ROOM. SHOW
 THE REQUIRED PLUMBING FIXTURE PER FBC-PLB TABLE 403.1
 3) PROVIDE HOW YOU SIZED THE INTERCEPTOR AND BY WHAT
 MEANS (PDI G101 OR FAC 64E-6). FBC-PLB 1003.3.4
 4) PROVIDE A PLUMBING SANITARY AND WATER ISOMETRIC
 DRAWING. FBC 107.3.5
 5) PROVIDE ALL ACCESSIBILITY DETAILS FOR THE 1ST FLOOR.
 FBC 107.3.5
  
  
 TIM HUNT
 PLUMBING PLAN REVIEW
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 561-248-2703
 [email protected]
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-05-29 Cont ID  
Sent By rmcdouga Date 2020-05-29 Time 11:30 Rev Time 0.00
Received By rmcdouga Date 2020-05-29 Time 11:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-05-11 Cont ID  
Sent By rmcdouga Date 2020-05-11 Time 13:50 Rev Time 0.00
Received By rmcdouga Date 2020-05-11 Time 13:50 Sent To  
Notes
2020-05-11 13:51:31SIGNATURES WILL NEED TO BE REVIEWED FOR EACH VERSION OF
 PLANS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-03-03 Cont ID  
Sent By rmcdouga Date 2020-03-03 Time 17:41 Rev Time 0.00
Received By rmcdouga Date 2020-03-03 Time 17:41 Sent To  
Notes
2020-03-03 17:43:57THE SIGNATURES ON THE STRUCTURAL SHEETS ARE SHOWING AS
 INVALID.

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status P Date 2020-05-29 Cont ID  
Sent By rmcdouga Date 2020-05-29 Time 11:32 Rev Time 0.00
Received By rmcdouga Date 2020-05-29 Time 11:32 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2020-05-11 Cont ID  
Sent By rmcdouga Date 2020-05-11 Time 13:39 Rev Time 0.00
Received By rmcdouga Date 2020-05-11 Time 13:39 Sent To  
Notes
2020-05-11 13:40:51THRESHOLD DOCUMENTS ARE NOT COMPLETE. SEE BUILDING
 COMMENTS.

Review Stop Z ZONING
Rev No 4 Status P Date 2020-06-03 Cont ID  
Sent By elevesqu Date 2020-06-03 Time 09:14 Rev Time 0.00
Received By elevesqu Date 2020-06-03 Time 09:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2020-04-30 Cont ID  
Sent By elevesqu Date 2020-04-30 Time 15:46 Rev Time 0.00
Received By elevesqu Date 2020-04-30 Time 15:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2020-04-21 Cont ID  
Sent By elevesqu Date 2020-04-21 Time 11:10 Rev Time 0.00
Received By elevesqu Date 2020-04-21 Time 11:10 Sent To  
Notes
2020-04-20 15:06:57FROM CONVERSATION WITH APPLICANT - ONE LOUVRED DOOR TO
 FPL ROOM IS BEING REMOVED- PLEASE UPDATE PLANS TO
 REFLECT
  
 PLEASE UPDATE SITE PLAN AND FIRST FLOOR PLANS TO MATCH
 MOST RECENTLY APPROVED WITH SITE PLAN APPROVAL - (FOR
 EXAMPLE, OPEN SPACE NOT UPDATED ON THIS VERSION)
  
 PLEASE INCLUDE CLEARLY MARKED SETBACK LINE ON SITE PLAN
  
 PHOTOMETRICS AND GARAGE PHOTOMETRICS HAVE BEEN REMOVED
 FROM PERMIT SET- TO BE REVIEWED THROUGH SEPARATE PERMIT
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-02-21 Cont ID  
Sent By elevesqu Date 2020-02-21 Time 16:47 Rev Time 0.00
Received By elevesqu Date 2020-02-21 Time 16:47 Sent To  
Notes
2020-02-21 16:48:00SITE PLAN APPROVAL NOT YET GRANTED
  
 PLEASE UPLOAD ALL UPDATED PLANS TO MATCH SITE PLAN
 APPROVAL PLANS ONCE IT HAS BEEN GRANTED
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426