| Plan Review Stops For Permit 20011288 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-27 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-12 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-12 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2020-05-28 11:05:17 | NO NOTES | | 2020-05-12 12:01:49 | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-04-14 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-04-13 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2020-04-13 17:14:05 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | | REVIEW CHECKLIST. | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 1- PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH | | | DIGITAL SIGNATURE. | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | RESPONSE: | | | PLANS SUBMITTED NOW HAVE A DIGITAL SIGNATURE THAT | | | BELONGS TO DANIEL CLAVIJO. ACCORDING TO THE DBPR | | | WEBSITE, DANIEL CLAVIJO IS NOT A FLORIDA LICENSED | | | ARCHITECT. NEED THE DIGITAL SIGNATURE OF A LICENSED | | | ARCHITECT WHEN SUBMITTING PLANS ELECTRONICALLY. | | | ORIGINAL PLANS D AND PLANS SUBMITTED NOW HAVE A THE | | | PRINTED IMAGE OF THE SEAL AND SIGNATURE OF PATRICK W. | | | SEGRAVES REGISTERED ARCHITECT. ACCORDING TO THIS, THIS | | | IS THE ARCHITECT RESPONSIBLE FOR THESE PLANS. WHY IS | | | ANOTHER PERSON THAT IS NOT LICENSED IN FLORIDA SIGNING | | | AND SEALING THESE PLANS? | | | PLEASE COMPLY WITH 61G1-16.005 PROCEDURES FOR DIGITALLY | | | SIGNING AND SEALING AND FOR ELECTRONICALLY TRANSMITTING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | ORIGINAL COMMENT: | | | 2- SCOPE OF WORK IS NOT CLEAR. THE DESCRIPTION OF THE | | | SCOPE OF WORK SPECIFIED ON THE PERMIT APPLICATION | | | SUBMITTED IS FOR "EXTERIOR LAP SIDING" ONLY. PLANS | | | SUBMITTED ARE FOR COMPLETE RENOVATION (ALTERATION LEVEL | | | 3) FOR THE FRONT AND REAR BUILDINGS. SCOPE OF WORK | | | SPECIFIED ON THE PERMIT APPLICATION AND SCOPE OF WORK | | | SHOWN ON PLANS NEED TO MATCH. REVISE AS REQUIRED. SEC. | | | 107.2.1 CITY AMENDMENTS. COMPLETE REVIEW PROCESS WILL | | | BE PERFORMED WHEN SCOPE OF WORK IS CORRECTED, INCLUDING | | | PLAN REVIEW BY ALL RELEVANT TRADES. NOTE: REVISE | | | VALUATION ACCORDINGLY. THE PERMIT FOR THE LAP SIDING | | | ONLY CAN NOT BE ISSUED AT THIS TIME BECAUSE BASED ON | | | DRAWINGS SUBMITTED THE EXTERIOR ELEVATIONS ARE GOING TO | | | BE CHANGED AND THERE IS AN PROPOSED ADDITION ALSO) ALL | | | THIS WORK WILL NEED TO BE APPROVED. | | | | | | RESPONSE: | | | SCOPE OF WORK WAS CLARIFIED. COMPLETE RENOVATION OF | | | BOTH BUILDINGS. THIS IS ALTERATION LEVEL 3. COMPLETE | | | BUILDING REVIEW WILL BE PERFORMED NOW. SEE COMMENTS | | | BELOW UNDER "NEW COMMENTS". | | | | | | 3- OK. | | | 4- OK | | | | | | ORIGINAL COMMENT: | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL). | | | (A) INSWING EXTERIOR DOORS AS SHOWN ON PLANS. | | | (B) OUTSWING EXTERIOR DOORS AS SHOWN ON PLANS. | | | (C) CARRIAGE DOOR SHUTTERS AS SHOWN ON PLANS. | | | (D) WINDOWS AS SHOWN ON PLANS. OPERABLE WINDOWS AND | | | FIXED WINDOWS. | | | (E) SHUTTERS AS SHOWN ON PLANS. AND PROVIDE COMPLETE | | | INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | | | | NEW COMMENTS. ALTERATION LEVEL 3. SEC. 505 FBC-EXISTING | | | BUILDING: | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 6- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR THE NEW DOORS AND WINDOWS OPENINGS AS SHOWN ON | | | PLANS. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | 7- WALL SECTION ON SHEET A-7. SPECIFY ALL STRUCTURAL | | | CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 8- MISSING THE STRUCTURAL DRAWINGS THAT ARE LISTED IN | | | THE INDEX ON THE COVER SHEET. PROVIDE ALL DRAWINGS THAT | | | ARE LISTED IN THE INDEX. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 9- IMPACT FEES - | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-02-13 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-02-13 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2020-02-13 14:04:19 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH | | | DIGITAL SIGNATURE. | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | 2- SCOPE OF WORK IS NOT CLEAR. THE DESCRIPTION OF THE | | | SCOPE OF WORK SPECIFIED ON THE PERMIT APPLICATION | | | SUBMITTED IS FOR "EXTERIOR LAP SIDING" ONLY. PLANS | | | SUBMITTED ARE FOR COMPLETE RENOVATION (ALTERATION LEVEL | | | 3) FOR THE FRONT AND REAR BUILDINGS. SCOPE OF WORK | | | SPECIFIED ON THE PERMIT APPLICATION AND SCOPE OF WORK | | | SHOWN ON PLANS NEED TO MATCH. REVISE AS REQUIRED. SEC. | | | 107.2.1 CITY AMENDMENTS. COMPLETE REVIEW PROCESS WILL | | | BE PERFORMED WHEN SCOPE OF WORK IS CORRECTED, INCLUDING | | | PLAN REVIEW BY ALL RELEVANT TRADES. NOTE: REVISE | | | VALUATION ACCORDINGLY. THE PERMIT FOR THE LAP SIDING | | | ONLY CAN NOT BE ISSUED AT THIS TIME BECAUSE BASED ON | | | DRAWINGS SUBMITTED THE EXTERIOR ELEVATIONS ARE GOING TO | | | BE CHANGED AND THERE IS AN PROPOSED ADDITION ALSO) ALL | | | THIS WORK WILL NEED TO BE APPROVED. | | | | | | 3- LAP SIDING SCOPE OF WORK IS NOT CLEAR. EXISTING | | | EXTERIOR ELEVATIONS SHOW VERTICAL SIDING, WHILE | | | PROPOSED EXTERIOR ELEVATIONS SHOW HORIZONTAL SIDING. | | | PROPOSED ELEVATIONS SPECIFY THAT ORIGINAL HORIZONTAL | | | SIDING UNDERNEATH TO BE RETAINED AND PRESERVED. ARE | | | THERE TWO LAYERS OF SIDING ON THIS HOUSES?. DEMOLITION | | | NOTES DON'T PROVIDE ANY SPECIFICATIONS FOR THE | | | DEMOLITION OF THE EXISTING SIDING. CLARIFY AS REQUIRED. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 4- -VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. UPDATE VALUATION OR PROVIDE COPY OF SIGNED | | | CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES. | | | | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL) | | | | | | 61G20-3.001 SCOPE. | | | (1) PRODUCTS IN THE FOLLOWING CATEGORIES NEED PRODUCT | | | APPROVAL FOR USE IN THE STATE: : | | | (A) PANEL WALLS; | | | (B) EXTERIOR DOORS; | | | (C) ROOFING PRODUCTS; | | | (D) SKYLIGHTS; | | | (E) WINDOWS; | | | (F) SHUTTERS; | | | (G) STRUCTURAL COMPONENTS; AND | | | (H) IMPACT PROTECTIVE SYSTEMS. | | | (2) THIS RULE APPLIES TO APPROVAL OF PRODUCTS AND | | | SYSTEMS, WHICH COMPRISE THE BUILDING ENVELOPE AND | | | STRUCTURAL FRAME, FOR COMPLIANCE WITH THE STRUCTURAL | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-28 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-04-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-28 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-27 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-02 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-02 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2020-04-02 14:34:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 3. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND | | | PANELS. NEC 110.3, 110.9; FBC RE E3606.3 | | | 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 6. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 | | | 7. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | 8. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 9. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 10. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | | CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 11. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR MAIN HOUSE. NEC 225.31, | | | 225.32 | | | 12. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 13. POOL WIL BE REQUIRED TO OBTAIN A SEPARATE PERMIT. | | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | | PERMITS AND PLAN SUBMITTALS FOR THE POOL. WPB FBC | | | 105.1, 107.2.1 | | | 14. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 15. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PLAN DOES NOT | | | SHOW COMPLIANCE. PROVIDE CORRECTION. NEC 210.11(C)(3) , | | | FBC RE E3703.4 | | | 16. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PLAN DOES NOT SHOW COMPLIANCE. PROVIDE | | | CORRECTION. NEC 210.11(C)(1) , FBC RE E3703.2 | | | 17. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR RECEPTACLE OUTLETS. RECEPTACLES SHALL | | | BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY | | | ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 | | | FEET FROM A RECEPTACLE OUTLET. THE WALL SPACING | | | REQUIREMENTS FOR KITCHEN COUNTER SPACE STATE THAT | | | RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT | | | ALONG THE WALL LINE IS MORE THAN 24 INCHES MEASURED | | | HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. | | | THE PLAN PROVIDED DOES NOT MEET THIS CODE IN SOME | | | AREAS. PROVIDE CORRECTION. NEC 210.52(C)(1); FBC RE | | | E3901 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-28 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-27 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-05-05 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-05-05 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2020-05-05 11:30:10 | 1ST REVIEW FBC-2017 GAS | | | PERMIT #20011288 | | | 5/5/202 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A SEPARATE PERMIT IS REQUIRED FOR THE GAS PIPING | | | INSTALLATIONS- SECTION 107.2.1 WPB. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-04-03 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-04-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-04-03 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-02-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-02-14 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-02-14 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-14 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-05-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-12 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-04-16 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-04-14 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-03-31 |
Time |
15:40 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-02-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-02-20 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-03 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-06-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-06-01 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-05-28 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2020-06-01 10:14:22 | MU 2020-018028 - $0 DUE | | 2020-05-28 14:56:54 | 5/28 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-04-14 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-04-14 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2020-04-14 12:16:58 | IMPACT FEES - DIGITAL SUBMITTALS | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-05-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-05-21 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-05-21 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2020-05-21 15:18:29 | APPROVED WITH PRIVISO- HAVE CU MANUFACTURE'S | | | INSTALLLATION INSTRUCTIONS ON THE JOB SITE FOR THE | | | INSPECTOR AT FINAL INSPECTION. FBC RES M10307.2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-17 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-17 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2020-04-17 13:56:39 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT-20011288 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | IT APPEARS THAT YOU HAVE INCLUDED THE ENERGY CALCS AND | | | MANUAL J CALCULATIONS FOR THE GUEST HOUSE ONLY. PLEASE | | | PROVIDE THE ENERGY CALCS. AND MANUAL J CALCS. FOR THE | | | MAIN HOUSE AS WELL. FBC EC 101.5.1.1.2 | | | ALSO PLEASE SHOW THE C/U?S ANCHORAGE MEETS FBC RES | | | M1307.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-04-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-04-01 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-04-01 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2020-04-01 14:32:23 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT- 20011288 | | | | | | CODES IN EFFECT: | | | | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE MECHANICAL SHEETS FOR THE NEW | | | MECHANICAL WORK ON THIS PROJECT. FBC WPB 107.3.5.1.4 , | | | FBC WPB 107.2.1. | | | | | | 2) MECHANICAL EQUIPMENT MUST BE SIZED WITH ACCA MANUAL | | | J. FBC EC R403.7. | | | | | | 3) PLEASE PROVIDE THE ENERGY FORM R405. FBC EC | | | 101.5.1.1.2 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-27 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-05-05 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-05-05 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2020-05-05 11:22:20 | 2ND REVIEW FBC-2017 PLUMBING | | | PERMIT #20011288 | | | 5/5/20 | | | | | | CODES IN EFFECT. | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P1 & P2: PROVIDE A CLEANOUT AT THE POINT | | | WHERE THE GUEST HOUSE BUILDING DRAIN EXITS THE | | | STRUCTURE AND CONNECTS TO THE SEWER PIPE- SECTION | | | P3005.2.3 FBC RES. | | | | | | 2) P1 & P2: PROVIDE A VENT FOR THE GUEST ROOM BATH | | | GROUP. IT APPEARS BY THE DRAWING THAT A VENT STACK | | | CONNECTED TO THE LAV. DRAIN WOULD BE A GOOD LOCATION- | | | SEE SECTION P3108.1 HORIZONTAL WET VENT- FBC RES. | | | | | | 3) P2: PLEASE SHOW THE WYE FITTING DRAIN CONNECTIONS | | | POSITIONED IN THE DIRECTION OF FLOW- SECTION P2608.1 | | | FBC RES. | | | | | | 4) P2: SHOW THE REQUIRED 2" TRAP AND 3" BRANCH DRAIN | | | FOR THE WASHING MACHINE- P3201.7 FBC RES & 406.2 FBC P. | | | | | | 5) P1 & P2: SHOW THE DISHWASHER LOCATIONS AND DRAIN | | | CONNECTION- P2717.2 FBC RES. | | | | | | 6) P1 & P2: THE SHOWER PANS SHALL COMPLY WITH SECTION | | | P2709.2 FBC RES, AND THE SHOWER VALVES SHALL COMPLY | | | WITH SECTION P2708.2 FBC RES. PLEASE PLACE NOTES AND/OR | | | DETAILS ON THE PLAN TO SHOW COMPLIANCE. | | | | | | 7) INSTALLATION OF AN RPZ BACKFLOW PREVENTER IS | | | REQUIRED FOR THE WATER SERVICE TO THE TWO SEPARATE | | | DWELLINGS ON THE SAME LOT. A FL. LICENSED PLUMBING | | | CONTRACTOR CERTIFIED FOR INSTALLATION SHALL SUBMIT A | | | SEPARATE PERMIT APPLICATION TO BE APPROVED BY THE WPB | | | BUILDING AND UTILITIES DEPARTMENTS. | | | | | | 8) P1: ACCORDING TO THE ENERGY COMPLIANCE SUBMITTAL AND | | | THE ELECTRIC PANEL SCHEDULES, GAS-FIRED TANKLESS WATER | | | HEATERS ARE TO BE INSTALLED FOR EACH BUILDING. | | | A) SHOW THE LOCATIONS OF THE UNITS ON THE PLAN ALONG | | | WITH ANY OTHER GAS-FIRED APPLIANCES EITHER NEW OR | | | EXISTING- SECTION 107.2.1 WPB. | | | B) PROVIDE WATER HEATER EQUIPMENT SCHEDULES ON THE PLAN | | | AND SUBMIT MANUFACTURE'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE WATER HEATERS AND ALL | | | NEW APPLIANCES- SECTION 107.2.1 WPB. | | | C) PROVIDE GAS ISOMETRIC DRAWINGS FOR EACH BUILDING | | | SHOWING THE TYPES AND SIZES OF GAS PIPING, DELIVERY | | | PRESSURES, TOTAL DEVELOPED LENGTH OF THE PIPING RUNS, | | | LENGTHS OF ALL CUT SECTIONS OF PIPING, LOCATIONS OF | | | REGULATORS, UNIONS, DRIP LEGS, AND PIPE CONNECTION | | | FITTINGS- SECTIONS G2413.4.1, G2413.4.2, G2413.3, | | | G2413.4, AND TABLES G2413.4(1) THROUGH G2413.4(21) FBC | | | RES. | | | D) SHOW LOCATIONS OF REQUIRED VENTS AND PROVIDE VENTING | | | DIAGRAMS THAT INDICATE THE TYPE AND SIZE OF VENT, TOTAL | | | RUN LENGTHS, TERMINATION LOCATIONS, AND SUPPORT | | | DETAILS- G2426- G2429 FBC RES. | | | E) PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR THE | | | GAS PIPING INSTALLATION- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-04-02 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-04-02 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2020-04-02 16:28:48 | 04/02/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 2. A BACKFLOW PREVENTER MAY BE REQUIRED SINCE THIS A | | | DUAL DWELLING PER THE CITY OF WEST PALM BEACH ORD | | | #2853-95. A PERMIT REQUIRED BY A LICENSED CONTRACTOR | | | AND MUST BE CERTIFIED BY UTILITIES PRIOR TO FINAL | | | INSPECTION. PLEASE CONTACT THE CITY OF WPB UTILITIES AT | | | 561-822-2240 FOR FURTHER DIRECTIONS. | | | | | | 3. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 4. THERE IS NO VALUE LISTED ON ANY PLUMBING OR | | | SUB-APPLICATION AND THE OVERALL VALUE IS LOW. WPB | | | AMENDMENTS TO THE FBC 109.3 BUILDING PERMITS | | | VALUATIONS. IF IN THE OPINION OF THE BUILDING OFFICIAL, | | | THE CLAIMED VALUATION OF BUILDING, ALTERATION, | | | STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR PLUMBING | | | SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED UNLESS THE | | | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR | | | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO | | | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR | | | PERMITTING PURPOSES, THE VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST | | | ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS | | | PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL | | | BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING | | | OFFICIAL. | | | | | | 5. HOT WATER REQUIRED, PLEASE SHOW THE SOURCE AND | | | APERTURE OF HOT WATER PER THE 2017 FBC R 2722.2. | | | | | | 6. PLANS ARE REQUIRED TO BE DESIGNED AND SIGNED AND | | | SEALED BY A LICENSED ENGINEER OR ARCHITECT. PLANS | | | FURNISHED BY AN INTERIOR DESIGNER ARE NOT ACCEPTABLE. | | | PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; FBC | | | 107.2.1, 107.3.5. | | | | | | 7. IF THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE | | | LINING FBC R 2709.2, NOTE: SHOWER PAN MUST HAVE A | | | SLOPED MORTAR BED THAT IS PRE-PITCHED BENEATH PRIOR TO | | | LINER INSTALLATION OF 1/4" IN PER FOOT TOWARD THE | | | DRAIN, MUST HAVE DAM CORNER, BACKING AROUND THE | | | PERIMETER AND BEFORE FINAL MORTAR APPLICATION PLACE | | | SOME PEA GRAVEL OVER WEEP HOLES SO THE MORTAR DOES NOT | | | COVER THEM PER MANUFACTURES SPECIFICATIONS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-04-14 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-04-14 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2020-04-14 11:10:57 | ROOFING PRODUCTS: | | | 1) CEDAR SHAKES & SHINGLES NOA 196-0917.03. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-05-28 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-05-27 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-04-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-28 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-28 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2020-04-28 09:07:59 | IF ANY NEW SHEETS ARE SUBMITTED FOR NEXT REVIEW, THEY | | | WILL NEED TO BE CHECKED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-02 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-04-02 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2020-04-13 17:02:39 | 04/13/2020. PLANS SUBMITTED NOW HAVE A DIGITAL | | | SIGNATURE THAT BELONGS TO DANIEL CLAVIJO. ACCORDING TO | | | THE DBPR WEBSITE, DANIEL CLAVIJO IS NOT A FLORIDA | | | LICENSED ARCHITECT. NEED THE DIGITAL SIGNATURE OF A | | | LICENSED ARCHITECT WHEN SUBMITTING PLANS | | | ELECTRONICALLY. ORIGINAL PLANS SUBMITTED AND PLANS | | | SUBMITTED NOW HAVE A THE PRINTED IMAGE OF THE SEAL AND | | | SIGNATURE OF PATRICK W. SEGRAVES REGISTERED ARCHITECT. | | | ACCORDING TO THIS, THIS IS THE ARCHITECT RESPONSIBLE | | | FOR THESE PLANS. WHY IS ANOTHER PERSON THAT IS NOT | | | LICENSED IN FLORIDA SIGNING AND SEALING THESE PLANS? | | | PLEASE COMPLY WITH 61G1-16.005 PROCEDURES FOR DIGITALLY | | | SIGNING AND SEALING AND FOR ELECTRONICALLY TRANSMITTING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | | | | | | | | | | ******************************************************* | | | ***************************************************** | | 2020-04-02 12:52:11 | ALL DIGITAL SIGNATURES THIS SUBMISSION ARE GOOD. ANY | | | NEW SUBMITTAL SHEETS FOR NEXT REVIEW WILL NEED TO BE | | | CHECKED. WPB FBC 105.1 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-02-13 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-02-13 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2020-02-13 13:17:55 | PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH | | | DIGITAL SIGNATURE. | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-04-03 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-04-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-04-03 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-02-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-02-14 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-02-14 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|