Plan Review Details - Permit 20011288
Plan Review Stops For Permit 20011288
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 11:28 Rev Time 0.00
Received By cthroop Date 2020-05-27 Time 15:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-05-12 Cont ID  
Sent By cthroop Date 2020-05-12 Time 11:55 Rev Time 0.00
Received By cthroop Date 2020-05-12 Time 10:19 Sent To  
Notes
2020-05-28 11:05:17NO NOTES
2020-05-12 12:01:49 
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-04-14 Cont ID  
Sent By jgomez Date 2020-04-14 Time 13:02 Rev Time 0.00
Received By jgomez Date 2020-04-13 Time 13:04 Sent To  
Notes
2020-04-13 17:14:05RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 DIGITAL SIGNATURE.
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 RESPONSE:
 PLANS SUBMITTED NOW HAVE A DIGITAL SIGNATURE THAT
 BELONGS TO DANIEL CLAVIJO. ACCORDING TO THE DBPR
 WEBSITE, DANIEL CLAVIJO IS NOT A FLORIDA LICENSED
 ARCHITECT. NEED THE DIGITAL SIGNATURE OF A LICENSED
 ARCHITECT WHEN SUBMITTING PLANS ELECTRONICALLY.
 ORIGINAL PLANS D AND PLANS SUBMITTED NOW HAVE A THE
 PRINTED IMAGE OF THE SEAL AND SIGNATURE OF PATRICK W.
 SEGRAVES REGISTERED ARCHITECT. ACCORDING TO THIS, THIS
 IS THE ARCHITECT RESPONSIBLE FOR THESE PLANS. WHY IS
 ANOTHER PERSON THAT IS NOT LICENSED IN FLORIDA SIGNING
 AND SEALING THESE PLANS?
 PLEASE COMPLY WITH 61G1-16.005 PROCEDURES FOR DIGITALLY
 SIGNING AND SEALING AND FOR ELECTRONICALLY TRANSMITTING
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 ORIGINAL COMMENT:
 2- SCOPE OF WORK IS NOT CLEAR. THE DESCRIPTION OF THE
 SCOPE OF WORK SPECIFIED ON THE PERMIT APPLICATION
 SUBMITTED IS FOR "EXTERIOR LAP SIDING" ONLY. PLANS
 SUBMITTED ARE FOR COMPLETE RENOVATION (ALTERATION LEVEL
 3) FOR THE FRONT AND REAR BUILDINGS. SCOPE OF WORK
 SPECIFIED ON THE PERMIT APPLICATION AND SCOPE OF WORK
 SHOWN ON PLANS NEED TO MATCH. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS. COMPLETE REVIEW PROCESS WILL
 BE PERFORMED WHEN SCOPE OF WORK IS CORRECTED, INCLUDING
 PLAN REVIEW BY ALL RELEVANT TRADES. NOTE: REVISE
 VALUATION ACCORDINGLY. THE PERMIT FOR THE LAP SIDING
 ONLY CAN NOT BE ISSUED AT THIS TIME BECAUSE BASED ON
 DRAWINGS SUBMITTED THE EXTERIOR ELEVATIONS ARE GOING TO
 BE CHANGED AND THERE IS AN PROPOSED ADDITION ALSO) ALL
 THIS WORK WILL NEED TO BE APPROVED.
  
 RESPONSE:
 SCOPE OF WORK WAS CLARIFIED. COMPLETE RENOVATION OF
 BOTH BUILDINGS. THIS IS ALTERATION LEVEL 3. COMPLETE
 BUILDING REVIEW WILL BE PERFORMED NOW. SEE COMMENTS
 BELOW UNDER "NEW COMMENTS".
  
 3- OK.
 4- OK
  
 ORIGINAL COMMENT:
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL).
 (A) INSWING EXTERIOR DOORS AS SHOWN ON PLANS.
 (B) OUTSWING EXTERIOR DOORS AS SHOWN ON PLANS.
 (C) CARRIAGE DOOR SHUTTERS AS SHOWN ON PLANS.
 (D) WINDOWS AS SHOWN ON PLANS. OPERABLE WINDOWS AND
 FIXED WINDOWS.
 (E) SHUTTERS AS SHOWN ON PLANS. AND PROVIDE COMPLETE
 INSTALLATION SCHEDULE. SEE CITY SAMPLE.
  
  
 NEW COMMENTS. ALTERATION LEVEL 3. SEC. 505 FBC-EXISTING
 BUILDING:
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE.
  
 6- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE NEW DOORS AND WINDOWS OPENINGS AS SHOWN ON
 PLANS. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 7- WALL SECTION ON SHEET A-7. SPECIFY ALL STRUCTURAL
 CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 8- MISSING THE STRUCTURAL DRAWINGS THAT ARE LISTED IN
 THE INDEX ON THE COVER SHEET. PROVIDE ALL DRAWINGS THAT
 ARE LISTED IN THE INDEX. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- IMPACT FEES -
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-13 Cont ID  
Sent By jgomez Date 2020-02-13 Time 14:05 Rev Time 0.00
Received By jgomez Date 2020-02-13 Time 10:48 Sent To  
Notes
2020-02-13 14:04:19RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 DIGITAL SIGNATURE.
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 2- SCOPE OF WORK IS NOT CLEAR. THE DESCRIPTION OF THE
 SCOPE OF WORK SPECIFIED ON THE PERMIT APPLICATION
 SUBMITTED IS FOR "EXTERIOR LAP SIDING" ONLY. PLANS
 SUBMITTED ARE FOR COMPLETE RENOVATION (ALTERATION LEVEL
 3) FOR THE FRONT AND REAR BUILDINGS. SCOPE OF WORK
 SPECIFIED ON THE PERMIT APPLICATION AND SCOPE OF WORK
 SHOWN ON PLANS NEED TO MATCH. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS. COMPLETE REVIEW PROCESS WILL
 BE PERFORMED WHEN SCOPE OF WORK IS CORRECTED, INCLUDING
 PLAN REVIEW BY ALL RELEVANT TRADES. NOTE: REVISE
 VALUATION ACCORDINGLY. THE PERMIT FOR THE LAP SIDING
 ONLY CAN NOT BE ISSUED AT THIS TIME BECAUSE BASED ON
 DRAWINGS SUBMITTED THE EXTERIOR ELEVATIONS ARE GOING TO
 BE CHANGED AND THERE IS AN PROPOSED ADDITION ALSO) ALL
 THIS WORK WILL NEED TO BE APPROVED.
  
 3- LAP SIDING SCOPE OF WORK IS NOT CLEAR. EXISTING
 EXTERIOR ELEVATIONS SHOW VERTICAL SIDING, WHILE
 PROPOSED EXTERIOR ELEVATIONS SHOW HORIZONTAL SIDING.
 PROPOSED ELEVATIONS SPECIFY THAT ORIGINAL HORIZONTAL
 SIDING UNDERNEATH TO BE RETAINED AND PRESERVED. ARE
 THERE TWO LAYERS OF SIDING ON THIS HOUSES?. DEMOLITION
 NOTES DON'T PROVIDE ANY SPECIFICATIONS FOR THE
 DEMOLITION OF THE EXISTING SIDING. CLARIFY AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 4- -VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. UPDATE VALUATION OR PROVIDE COPY OF SIGNED
 CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL)
  
 61G20-3.001 SCOPE.
 (1) PRODUCTS IN THE FOLLOWING CATEGORIES NEED PRODUCT
 APPROVAL FOR USE IN THE STATE: :
 (A) PANEL WALLS;
 (B) EXTERIOR DOORS;
 (C) ROOFING PRODUCTS;
 (D) SKYLIGHTS;
 (E) WINDOWS;
 (F) SHUTTERS;
 (G) STRUCTURAL COMPONENTS; AND
 (H) IMPACT PROTECTIVE SYSTEMS.
 (2) THIS RULE APPLIES TO APPROVAL OF PRODUCTS AND
 SYSTEMS, WHICH COMPRISE THE BUILDING ENVELOPE AND
 STRUCTURAL FRAME, FOR COMPLIANCE WITH THE STRUCTURAL
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 11:09 Rev Time 0.00
Received By cthroop Date 2020-05-28 Time 11:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-04-28 Cont ID  
Sent By jpearson Date 2020-04-28 Time 09:07 Rev Time 0.00
Received By jpearson Date 2020-04-27 Time 15:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-04-02 Cont ID  
Sent By jpearson Date 2020-04-02 Time 16:31 Rev Time 0.00
Received By jpearson Date 2020-04-02 Time 10:11 Sent To  
Notes
2020-04-02 14:34:12CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 3. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9; FBC RE E3606.3
 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 6. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS
 SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8(A)(9); FBC RE E3902.9
 7. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220; FBC RE E3602.2
 8. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 9. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 10. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS
 LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY
 ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS
 SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE
 CORRECTION. NEC 410.16; FBC RE E4003.12
 11. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR MAIN HOUSE. NEC 225.31,
 225.32
 12. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR
 A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH
 CIRCUIT. NEC 250.32; FBC RE3607.3
 13. POOL WIL BE REQUIRED TO OBTAIN A SEPARATE PERMIT.
 PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE
 PERMITS AND PLAN SUBMITTALS FOR THE POOL. WPB FBC
 105.1, 107.2.1
 14. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 15. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PLAN DOES NOT
 SHOW COMPLIANCE. PROVIDE CORRECTION. NEC 210.11(C)(3) ,
 FBC RE E3703.4
 16. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE
 OUTLET(S). PLAN DOES NOT SHOW COMPLIANCE. PROVIDE
 CORRECTION. NEC 210.11(C)(1) , FBC RE E3703.2
 17. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR RECEPTACLE OUTLETS. RECEPTACLES SHALL
 BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY
 ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6
 FEET FROM A RECEPTACLE OUTLET. THE WALL SPACING
 REQUIREMENTS FOR KITCHEN COUNTER SPACE STATE THAT
 RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT
 ALONG THE WALL LINE IS MORE THAN 24 INCHES MEASURED
 HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE.
 THE PLAN PROVIDED DOES NOT MEET THIS CODE IN SOME
 AREAS. PROVIDE CORRECTION. NEC 210.52(C)(1); FBC RE
 E3901
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 11:11 Rev Time 0.00
Received By cthroop Date 2020-05-28 Time 11:11 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 12:40 Rev Time 0.00
Received By cthroop Date 2020-05-27 Time 15:14 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-05-05 Cont ID  
Sent By ccole Date 2020-05-05 Time 11:27 Rev Time 0.00
Received By ccole Date 2020-05-05 Time 11:27 Sent To  
Notes
2020-05-05 11:30:101ST REVIEW FBC-2017 GAS
 PERMIT #20011288
 5/5/202
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A SEPARATE PERMIT IS REQUIRED FOR THE GAS PIPING
 INSTALLATIONS- SECTION 107.2.1 WPB.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-04-03 Cont ID  
Sent By fmittner Date 2020-04-03 Time 11:49 Rev Time 0.00
Received By fmittner Date 2020-04-03 Time 11:49 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-02-14 Cont ID  
Sent By fmittner Date 2020-02-14 Time 12:22 Rev Time 0.00
Received By fmittner Date 2020-02-14 Time 12:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 12:40 Rev Time 0.00
Received By cthroop Date 2020-05-14 Time 13:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-05-12 Cont ID  
Sent By cthroop Date 2020-05-12 Time 12:22 Rev Time 0.00
Received By cthroop Date 2020-04-16 Time 13:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-04-14 Cont ID  
Sent By jgomez Date 2020-04-14 Time 13:09 Rev Time 0.00
Received By jgomez Date 2020-03-31 Time 15:40 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-20 Cont ID  
Sent By lmarchan Date 2020-02-20 Time 09:48 Rev Time 0.00
Received By lmarchan Date 2020-02-03 Time 09:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-06-01 Cont ID  
Sent By lmarchan Date 2020-06-01 Time 10:13 Rev Time 0.00
Received By lmarchan Date 2020-05-28 Time 14:56 Sent To  
Notes
2020-06-01 10:14:22MU 2020-018028 - $0 DUE
2020-05-28 14:56:545/28 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-04-14 Cont ID  
Sent By jgomez Date 2020-04-14 Time 12:16 Rev Time 0.00
Received By jgomez Date 2020-04-14 Time 12:16 Sent To  
Notes
2020-04-14 12:16:58IMPACT FEES - DIGITAL SUBMITTALS
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-05-21 Cont ID  
Sent By medwards Date 2020-05-21 Time 15:12 Rev Time 0.00
Received By medwards Date 2020-05-21 Time 15:12 Sent To  
Notes
2020-05-21 15:18:29APPROVED WITH PRIVISO- HAVE CU MANUFACTURE'S
 INSTALLLATION INSTRUCTIONS ON THE JOB SITE FOR THE
 INSPECTOR AT FINAL INSPECTION. FBC RES M10307.2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-04-17 Cont ID  
Sent By medwards Date 2020-04-17 Time 13:55 Rev Time 0.00
Received By medwards Date 2020-04-17 Time 13:55 Sent To  
Notes
2020-04-17 13:56:392ND REVIEW FBC-2017 MECHANICAL
 PERMIT-20011288
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 IT APPEARS THAT YOU HAVE INCLUDED THE ENERGY CALCS AND
 MANUAL J CALCULATIONS FOR THE GUEST HOUSE ONLY. PLEASE
 PROVIDE THE ENERGY CALCS. AND MANUAL J CALCS. FOR THE
 MAIN HOUSE AS WELL. FBC EC 101.5.1.1.2
 ALSO PLEASE SHOW THE C/U?S ANCHORAGE MEETS FBC RES
 M1307.2
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-04-01 Cont ID  
Sent By medwards Date 2020-04-01 Time 14:31 Rev Time 0.00
Received By medwards Date 2020-04-01 Time 14:17 Sent To  
Notes
2020-04-01 14:32:231ST REVIEW FBC-2017 MECHANICAL
 PERMIT- 20011288
  
 CODES IN EFFECT:
  
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MECHANICAL SHEETS FOR THE NEW
 MECHANICAL WORK ON THIS PROJECT. FBC WPB 107.3.5.1.4 ,
 FBC WPB 107.2.1.
  
 2) MECHANICAL EQUIPMENT MUST BE SIZED WITH ACCA MANUAL
 J. FBC EC R403.7.
  
 3) PLEASE PROVIDE THE ENERGY FORM R405. FBC EC
 101.5.1.1.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 12:40 Rev Time 0.00
Received By cthroop Date 2020-05-27 Time 15:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-05-05 Cont ID  
Sent By ccole Date 2020-05-05 Time 11:21 Rev Time 0.00
Received By ccole Date 2020-05-05 Time 09:30 Sent To  
Notes
2020-05-05 11:22:202ND REVIEW FBC-2017 PLUMBING
 PERMIT #20011288
 5/5/20
  
 CODES IN EFFECT.
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1 & P2: PROVIDE A CLEANOUT AT THE POINT
 WHERE THE GUEST HOUSE BUILDING DRAIN EXITS THE
 STRUCTURE AND CONNECTS TO THE SEWER PIPE- SECTION
 P3005.2.3 FBC RES.
  
 2) P1 & P2: PROVIDE A VENT FOR THE GUEST ROOM BATH
 GROUP. IT APPEARS BY THE DRAWING THAT A VENT STACK
 CONNECTED TO THE LAV. DRAIN WOULD BE A GOOD LOCATION-
 SEE SECTION P3108.1 HORIZONTAL WET VENT- FBC RES.
  
 3) P2: PLEASE SHOW THE WYE FITTING DRAIN CONNECTIONS
 POSITIONED IN THE DIRECTION OF FLOW- SECTION P2608.1
 FBC RES.
  
 4) P2: SHOW THE REQUIRED 2" TRAP AND 3" BRANCH DRAIN
 FOR THE WASHING MACHINE- P3201.7 FBC RES & 406.2 FBC P.
  
 5) P1 & P2: SHOW THE DISHWASHER LOCATIONS AND DRAIN
 CONNECTION- P2717.2 FBC RES.
  
 6) P1 & P2: THE SHOWER PANS SHALL COMPLY WITH SECTION
 P2709.2 FBC RES, AND THE SHOWER VALVES SHALL COMPLY
 WITH SECTION P2708.2 FBC RES. PLEASE PLACE NOTES AND/OR
 DETAILS ON THE PLAN TO SHOW COMPLIANCE.
  
 7) INSTALLATION OF AN RPZ BACKFLOW PREVENTER IS
 REQUIRED FOR THE WATER SERVICE TO THE TWO SEPARATE
 DWELLINGS ON THE SAME LOT. A FL. LICENSED PLUMBING
 CONTRACTOR CERTIFIED FOR INSTALLATION SHALL SUBMIT A
 SEPARATE PERMIT APPLICATION TO BE APPROVED BY THE WPB
 BUILDING AND UTILITIES DEPARTMENTS.
  
 8) P1: ACCORDING TO THE ENERGY COMPLIANCE SUBMITTAL AND
 THE ELECTRIC PANEL SCHEDULES, GAS-FIRED TANKLESS WATER
 HEATERS ARE TO BE INSTALLED FOR EACH BUILDING.
 A) SHOW THE LOCATIONS OF THE UNITS ON THE PLAN ALONG
 WITH ANY OTHER GAS-FIRED APPLIANCES EITHER NEW OR
 EXISTING- SECTION 107.2.1 WPB.
 B) PROVIDE WATER HEATER EQUIPMENT SCHEDULES ON THE PLAN
 AND SUBMIT MANUFACTURE'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE WATER HEATERS AND ALL
 NEW APPLIANCES- SECTION 107.2.1 WPB.
 C) PROVIDE GAS ISOMETRIC DRAWINGS FOR EACH BUILDING
 SHOWING THE TYPES AND SIZES OF GAS PIPING, DELIVERY
 PRESSURES, TOTAL DEVELOPED LENGTH OF THE PIPING RUNS,
 LENGTHS OF ALL CUT SECTIONS OF PIPING, LOCATIONS OF
 REGULATORS, UNIONS, DRIP LEGS, AND PIPE CONNECTION
 FITTINGS- SECTIONS G2413.4.1, G2413.4.2, G2413.3,
 G2413.4, AND TABLES G2413.4(1) THROUGH G2413.4(21) FBC
 RES.
 D) SHOW LOCATIONS OF REQUIRED VENTS AND PROVIDE VENTING
 DIAGRAMS THAT INDICATE THE TYPE AND SIZE OF VENT, TOTAL
 RUN LENGTHS, TERMINATION LOCATIONS, AND SUPPORT
 DETAILS- G2426- G2429 FBC RES.
 E) PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR THE
 GAS PIPING INSTALLATION- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-04-02 Cont ID  
Sent By lcrespo Date 2020-04-02 Time 16:28 Rev Time 0.00
Received By lcrespo Date 2020-04-02 Time 07:31 Sent To  
Notes
2020-04-02 16:28:4804/02/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 2. A BACKFLOW PREVENTER MAY BE REQUIRED SINCE THIS A
 DUAL DWELLING PER THE CITY OF WEST PALM BEACH ORD
 #2853-95. A PERMIT REQUIRED BY A LICENSED CONTRACTOR
 AND MUST BE CERTIFIED BY UTILITIES PRIOR TO FINAL
 INSPECTION. PLEASE CONTACT THE CITY OF WPB UTILITIES AT
 561-822-2240 FOR FURTHER DIRECTIONS.
  
 3. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL
 PLUMBING.
  
 4. THERE IS NO VALUE LISTED ON ANY PLUMBING OR
 SUB-APPLICATION AND THE OVERALL VALUE IS LOW. WPB
 AMENDMENTS TO THE FBC 109.3 BUILDING PERMITS
 VALUATIONS. IF IN THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF BUILDING, ALTERATION,
 STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR PLUMBING
 SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED UNLESS THE
 APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR
 BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO
 MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR
 PERMITTING PURPOSES, THE VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST
 ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS
 PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL
 BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING
 OFFICIAL.
  
 5. HOT WATER REQUIRED, PLEASE SHOW THE SOURCE AND
 APERTURE OF HOT WATER PER THE 2017 FBC R 2722.2.
  
 6. PLANS ARE REQUIRED TO BE DESIGNED AND SIGNED AND
 SEALED BY A LICENSED ENGINEER OR ARCHITECT. PLANS
 FURNISHED BY AN INTERIOR DESIGNER ARE NOT ACCEPTABLE.
 PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; FBC
 107.2.1, 107.3.5.
  
 7. IF THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE
 LINING FBC R 2709.2, NOTE: SHOWER PAN MUST HAVE A
 SLOPED MORTAR BED THAT IS PRE-PITCHED BENEATH PRIOR TO
 LINER INSTALLATION OF 1/4" IN PER FOOT TOWARD THE
 DRAIN, MUST HAVE DAM CORNER, BACKING AROUND THE
 PERIMETER AND BEFORE FINAL MORTAR APPLICATION PLACE
 SOME PEA GRAVEL OVER WEEP HOLES SO THE MORTAR DOES NOT
 COVER THEM PER MANUFACTURES SPECIFICATIONS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-04-14 Cont ID  
Sent By jgomez Date 2020-04-14 Time 11:09 Rev Time 0.00
Received By jgomez Date 2020-04-14 Time 11:08 Sent To  
Notes
2020-04-14 11:10:57ROOFING PRODUCTS:
 1) CEDAR SHAKES & SHINGLES NOA 196-0917.03.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-05-28 Cont ID  
Sent By cthroop Date 2020-05-28 Time 11:11 Rev Time 0.00
Received By cthroop Date 2020-05-27 Time 15:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-04-28 Cont ID  
Sent By jpearson Date 2020-04-28 Time 09:06 Rev Time 0.00
Received By jpearson Date 2020-04-28 Time 09:06 Sent To  
Notes
2020-04-28 09:07:59IF ANY NEW SHEETS ARE SUBMITTED FOR NEXT REVIEW, THEY
 WILL NEED TO BE CHECKED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-04-02 Cont ID  
Sent By jpearson Date 2020-04-02 Time 12:52 Rev Time 0.00
Received By jgomez Date 2020-04-02 Time 12:52 Sent To  
Notes
2020-04-13 17:02:3904/13/2020. PLANS SUBMITTED NOW HAVE A DIGITAL
 SIGNATURE THAT BELONGS TO DANIEL CLAVIJO. ACCORDING TO
 THE DBPR WEBSITE, DANIEL CLAVIJO IS NOT A FLORIDA
 LICENSED ARCHITECT. NEED THE DIGITAL SIGNATURE OF A
 LICENSED ARCHITECT WHEN SUBMITTING PLANS
 ELECTRONICALLY. ORIGINAL PLANS SUBMITTED AND PLANS
 SUBMITTED NOW HAVE A THE PRINTED IMAGE OF THE SEAL AND
 SIGNATURE OF PATRICK W. SEGRAVES REGISTERED ARCHITECT.
 ACCORDING TO THIS, THIS IS THE ARCHITECT RESPONSIBLE
 FOR THESE PLANS. WHY IS ANOTHER PERSON THAT IS NOT
 LICENSED IN FLORIDA SIGNING AND SEALING THESE PLANS?
 PLEASE COMPLY WITH 61G1-16.005 PROCEDURES FOR DIGITALLY
 SIGNING AND SEALING AND FOR ELECTRONICALLY TRANSMITTING
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
  
  
 *******************************************************
 *****************************************************
2020-04-02 12:52:11ALL DIGITAL SIGNATURES THIS SUBMISSION ARE GOOD. ANY
 NEW SUBMITTAL SHEETS FOR NEXT REVIEW WILL NEED TO BE
 CHECKED. WPB FBC 105.1

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-02-13 Cont ID  
Sent By jgomez Date 2020-02-13 Time 13:16 Rev Time 0.00
Received By jgomez Date 2020-02-13 Time 13:15 Sent To  
Notes
2020-02-13 13:17:55PLANS ARE SUBMITTED ELECTRONICALLY. NEED PLANS WITH
 DIGITAL SIGNATURE.
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-04-03 Cont ID  
Sent By fmittner Date 2020-04-03 Time 11:49 Rev Time 0.00
Received By fmittner Date 2020-04-03 Time 11:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-02-14 Cont ID  
Sent By fmittner Date 2020-02-14 Time 12:22 Rev Time 0.00
Received By fmittner Date 2020-02-14 Time 12:22 Sent To  
Notes
***NONE***