Plan Review Details - Permit 20011267
| Plan Review Stops For Permit 20011267 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2020-06-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-06-22 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-06-22 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2020-06-22 16:48:15 | PRIMARY ADDRESS: 696 S OLIVE | | | SUITE: 655 S OLIVE | | | SUITE: 645 S OLIVE | | | SUITE 635 S OLIVE | | | SUITE: 66 TANGLEWOOD CT | | | | | | ALL APPROVED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2020-04-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-04-20 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-04-20 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2020-05-08 16:12:32 | MAIN BUILDING ADDRESS CHANGED FROM 625 S OLIVE TO 695 S | | | OLIVE, STILL NEED TO ESTABLISH ADDRESSES FOR SUITES & | | | PET SALON. M CP | | 2020-04-20 15:25:11 | NEED SEPARATE ADDRESS FOR PET SPA ON TANGLEWOOD, FOR | | | THE 3 SUITE/RESTRAUNT SPACES ON SOUTH OLIVE AND FOR THE | | | ACTUAL BUILDING ITSLF WHICH WILL BE BASED ON THE | | | LOVCATION OF THE LOBBY/LEASING OFFICE/ MAILROOM. PLEASE | | | CONTACT [email protected] TO DISCUSS POSSIBLE OPTIONS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-02-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-02-18 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-02-18 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2020-02-18 16:52:29 | CONTACTED CUSTOMER TO ADDRESS ADDRESSING ISSUES, | | | WAITING TO HEAR BACK. | | | | | | PLEASE CONTACT [email protected] |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
P |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-18 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-18 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2020-02-18 11:20:05 | APPROVED WITH EXCEPTION. | | | THIS ITEM HAS BEEN APPROVED PROVISIONALLY. THIS | | | REQUIREMENT WILL HAVE TO BE ADDRESSED PRIOR TO | | | RECEIVING A C.O. FOR THE BUILDING. | | | | | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR AT | | | 822-1515 OR E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-31 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-31 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-14 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-13 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2020-07-13 15:11:21 | 3RD REVIEW | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | PLAN REVIEW COMMENTS | | | THRESHOLD BUILDING | | | 8 STORY APARTMENT BUILDING (MIXED USE M, S-2, R-2, A-3 | | | AND B) | | | CONST. TYPE I-A, SPRINKLERED | | | 170 MPH, EXPOSURE "D" | | | FLOOD ZONE "X" | | | 625 S. OLIVE AVE. | | | PERMIT #20011267 | | | | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NOT COMPLIED. REQUEST TO DEFER HAS NOT BEEN RECEIVED | | | FROM THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE | | | CHARGE. THE ITEMS TO BE DEFERRED NEED TO BE LISTED ON | | | THE PLANS. PREVIOUSLY (#38) THE FBC 107.3.4.1 DEFERRED | | | SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED | | | SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN | | | THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION | | | AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL | | | WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL | | | ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING | | | OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS | | | ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE | | | BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL | | | ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW | | | THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A | | | NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | 2) NOT COMPLIED. THE NOTE IN THE RESPONSE NARRATIVE | | | NEEDS TO BE ON THE PLANS. PREVIOUSLY (#39) SHOW | | | COMPLIANCE FBC ACCESSIBILITY SECTION 242 FOR ACCESSIBLE | | | ENTRY INTO THE POOL OR SPECIFY ON THE PLANS WHY IT IS | | | NOT REQUIRED. COMMUNITY POOLS THAT ARE ASSOCIATED WITH | | | A PRIVATE RESIDENTIAL COMMUNITY THAT DO NOT RECEIVE | | | GOVERNMENTAL FINANCIAL ASSISTANCE OR SPONSORSHIP AND | | | ARE LIMITED TO THE EXCLUSIVE OF RESIDENTS AND THEIR | | | GUESTS ARE NOT COVERED BY THE ADA ACCESSIBILITY | | | REQUIREMENTS, INCLUDING PROVISIONS FOR POOL LIFTS OR | | | SLOPED ENTRIES. IF A SWIMMING POOL LOCATED IN A | | | RESIDENTIAL COMMUNITY IS MADE AVAILABLE TO THE PUBLIC | | | FOR RENTAL OR USE IT IS REQUIRED TO COMPLY WITH TITLE | | | II OF THE ADA. SPECIFY ON THE PLANS THE FORMER OR SHOW | | | COMPLIANCE WITH THE LATTER STATEMENTS. SEE DECLARATORY | | | STATEMENT, DS 2013-011. | | | | | | 3) NOT COMPLIED. PREVIOUSLY (#40) SEPARATE PERMITS, | | | REVIEWS AND FEES ARE REQUIRED FOR SOME ITEMS THAT MAY | | | HAVE BEEN INCLUDED IN THE VALUE FOR THIS PROJECT. ITEMS | | | SUCH AS FIRE ALARM, FIRE SPRINKLER, LOW VOLTAGE, | | | LANDSCAPING, IRRIGATION AND ALL ITEMS OTHER THAN | | | BUILDING, MECHANICAL, ELECTRIC AND PLUMBING. PLEASE | | | PROVIDE A COST BREAKDOWN SO THAT WE CAN DEDUCT THESE | | | ITEMS FROM THE PERMIT VALUE SO THAT YOU WILL NOT BE | | | CHARGED TWICE FOR THE SAME ITEM. | | | | | | 4) NEW COMMENT. THE PROPOSED DOOR FROM SUITE 300, THE | | | REST./RETAIL AREA, ON THE GROUND FLOOR THAT OPENS INTO | | | THE PARKING GARAGE IS LOCATED IN A ONE HOUR FIRE | | | RESISTIVE RATED WALL. TABLE 508.4 REQUIRES A ONE HOUR | | | FIRE SEPARATION BETWEEN S-2 AND M OR B OCCUPANCIES IN A | | | SPRINKLERED BUILDING. THIS DOOR IS REQUIRED TO BE FIRE | | | RATED AND THE DOOR SCHEDULE ON SHEET A8-01 DOES NOT | | | SHOW A FIRE RATING FOR DOOR C300C. THIS DOOR IS | | | SPECIFIED AS TYPE D5 WHICH IS A GLAZED DOOR. | | | | | | 5) PLEASE PROVIDE A RESPONSE LETTER ADDRESSING HOW EACH | | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-05-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-05-14 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-05-13 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2020-05-11 14:38:13 | PLAN REVIEW COMMENTS | | | THRESHOLD BUILDING | | | 8 STORY APARTMENT BUILDING (MIXED USE M, S-2, R-2, A-3 | | | AND B) | | | CONST. TYPE 1-A, SPRINKLERED | | | 170 MPH, EXPOSURE "D" | | | FLOOD ZONE "X" | | | 625 S. OLIVE AVE. | | | PERMIT #20011267 | | | | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PROVISO. WILL COMPLY WITH AIPP BEFORE RECEIVING C.O. | | | | | | 2) PARTIALLY COMPLIED. AT A MINIMUM ALL STRUCTURAL | | | PLANS THAT ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ENGINEER OF RECORD ARE REQUIRED TO HAVE THE THRESHOLD | | | BUILDING STATEMENT. A COMPLETE SET OF THRESHOLD | | | DOCUMENTS IS REQUIRED. THE CONTRACTOR'S AND OWNER'S | | | NOTARIZED THRESHOLD DOCUMENTS WERE NOT SUBMITTED. THE | | | CONTRACTOR, KAST CONSTRUCTION, HAS DONE SIMILAR | | | PROJECTS IN THIS JURISDICTION SO A JOB SUMMARY IS NOT | | | REQUIRED. A RESUME OF THE SPECIAL INSPECTOR'S PREVIOUS | | | INSPECTION EXPERIENCE WAS NOT SUBMITTED. THE THRESHOLD | | | BUILDING COMPLIANCE STATEMENT IS REQUIRED ON ALL OF THE | | | STRUCTURAL SHEETS, INCLUDING SCHEDULES AND DETAILS. | | | THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION | | | PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | | IN BLACK & WHITE. | | | G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR | | | THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS | | | REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, | | | APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND | | | CEILINGS. | | | J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT ( OCTOBER | | | 2018 ) CITY GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT | | | INSPECTORS. | | | | | | 3) COMPLIED. LETTER FROM GEOTECHNICAL ENGINEER RE: | | | INCREASE SOIL CAPACITY TO 8,000 PSF WAS SUBMITTED WITH | | | FOUNDATION ONLY PERMIT, #20020004. | | | | | | 4) COMPLIED. MOT AND CONSTRUCTION SAFEGUARD PLAN | | | SUBMITTED WITH FOUNDATION ONLY PERMIT, #20020004. | | | | | | 5) COMPLIED. ONE OF THE ELEVATORS IS SHOWN TO COMPLY | | | WITH FBC 3002.4. | | | | | | 6) COMPLIED. THE TRASH CHUTE DISCHARGE ROOM HAS BEEN | | | GIVEN A 2 HOUR FIRE RATING. | | | | | | 7) PARTICALLY COMPLIED. THE EXIT PASSAGEWAY AT STAIR 01 | | | WAS RELABELED AS AN EXIT PASSAGEWAY. PLEASE ADD A NOTE | | | STATING THAT PENETRATIONS INTO OR THROUGH AN EXIT | | | PASSAGEWAY ARE PROHIBITED EXCEPT FOR EQUIPMENT AND | | | OTHER ITEMS SERVING THE EXIT PASSAGEWAY IN ACCORDANCE | | | WITH FBC 1024.6. ON SHEET A1-0 THE NOTE CALLING THIS AN | | | EGRESS AND MOVE IN CORRIDOR NEEDS TO BE REPLACED WITH | | | THE EXIT PASSAGEWAY LABEL AND ITS NOTES. | | | | | | 8) COMPLIED. PROVIDE A SITE PLAN WITH ELEVATIONS SHOWN | | | IN NAVD 88. THERE WAS ONE WITH THE FOUNDATION PLAN, BUT | | | IT APPEARS TO BE MISSING FROM THESE DOCUMENTS. FBC | | | 107.2.1.2 | | | PLEASE REVIEW THE ELEVATIONS OF THE GRADE AROUND THE | | | EXTERIOR OF THE BUILDING AND COMPARE THEM WITH THE | | | FLOOR ELEVATION (11.97') OF THE BUILDING TO MAKE SURE | | | THAT THE EXITS DISCHARGE AT GRADE AND THE ELEVATIONS | | | AND SLOPES OF LANDINGS AND WALK WAYS WILL MEET THE | | | RUNNING SLOPE AND CROSS SLOPE REQUIREMENTS OF THE | | | FLORIDA ACCESSIBILITY CODE SECTION 403. | | | | | | 9) NOT COMPLIED. THE ORIENTATIONS DO NOT APPEAR TO BE | | | CORRECT. AR-01 IS AT THE SOUTH OF THE BUILDING LOOKING | | | WEST. AR-02 IS AT THE NORTH OF THE BUILDING LOOKING | | | WEST. AR-03 IS AT THE NORTH OF THE BUILDING LOOKING | | | EAST. AR-04 IS AT THE SOUTH OF THE BUILDING LOOKING | | | EAST. THE AR-RENDERINGS APPEAR TO BE MISLABELED. PLEASE | | | CLARIFY. FBC 107.2.1 | | | | | | 10) NOT APPLICABLE. FBC TABLE 602 REQUIRES MERCANTILE | | | OCCUPANCIES TO HAVE 2 HOUR FIRE RESISTANCE RATED | | | EXTERIOR WALLS FOR LESS THAN 10 FT OF FIRE SEPARATION | | | DISTANCE. THIS IS NOT REFLECTED IN THE CODE DATA ON | | | SHEET CD-1. HOWEVER, THIS DOES NOT APPEAR TO BE AN | | | ISSUE FOR YOUR PROJECT. | | | | | | 11) COMPLIED. HOWEVER, THE WIND VELOCITY FOR THIS | | | PROJECT IS 170 MPH NOT 180 MPH. CHANGED FROM BROWARD | | | COUNTY TO PALM BEACH COUNTY. | | | | | | 12) COMPLIED. THE RED DASHED CIRCLES WERE REMOVED. | | | | | | 13) NO RESPONSE LETTER WAS SUBMITTED TO ADDRESS THIS | | | QUESTION. THERE IS A STAIR #04 SHOWN ON THE PLANS | | | BETWEEN THE 2ND AND 3RD LEVELS OF THE PARKING GARAGE | | | WITH A NOTE (WHICH IS MISLABELED AS STAIR 03 ON CD-02) | | | THAT IT IS TO PREVENT A DEAD END CONDITION AT LEVEL 3. | | | PLEASE CLARIFY. | | | | | | 14) COMPLIED. THE COMMERCIAL AREAS ON THE GROUND FLOOR | | | USED A-2 TO DETERMINE OCCUPANT LOADS. | | | | | | 15) COMPLIED. THE COVERED OUTDOOR RESTAURANT SEATING | | | RELABELED AS A-2. | | | | | | 16) COMPLIED. ELEVATOR 1 IS SHOWN TO MEET STRETCHER | | | REQUIREMENT. | | | | | | 17) NO RESPOSE LETTER ADDRESSING COMMENT WAS SUBMITTED. | | | ADD A NOTE ON THE GROUND FLOOR PLANS WITH A SHADED AREA | | | TO STATE THAT A MINIMUM OVERHEAD CLEARANCE OF 8' -2" IS | | | REQUIRED IN THAT AREA. VERIFY THE REQUIRED VERTICAL | | | CLEARANCE OF 98 INCHES FOR THE VAN PARKING SPACE, | | | ACCESS AISLE AND VEHICULAR ROUTE SERVING IT AS REQUIRED | | | BY FBC ACCESSIBILITY SECTION 502.5. | | | | | | 18) NOT COMPLIED. THE PARKING TABLE ON A1-01 WAS | | | CORRECTED, BUT NOT THE ONE ON GN-00. THE PARKING DATA | | | ON SHEET GN-00 HAS 20 COMMERCIAL SPACES AND 183 | | | RESIDENTIAL SPACES. TABLE 208.2 IN THE FBC | | | ACCESSIBILITY REQUIRES A MINIMUM OF 1 ACCESSIBLE | | | PARKING SPACE WHEN THE TOTAL NUMBER OF SPACES PROVIDED | | | IS 1 TO 25. THE FAIR HOUSING GUIDELINES REQUIRE AT | | | LEAST 2 PERCENT OF THE COVERED RESIDENTIAL UNITS TO | | | HAVE ACCESSIBLE PARKING WHICH IS 4 SPACES. THIS PROJECT | | | IS REQUIRED TO HAVE A MINIMUM OF 5 ACCESSIBLE PARKING | | | SPACES. THE PLANS SHOW ONLY 4 ACCESSIBLE SPACES. | | | SECTION 208.2.4 REQUIRES AT LEAST ONE VAN PARKING SPACE | | | COMPLYING WITH SECTION 502 FOR EVERY SIX OR FRACTION OF | | | SIX REQUIRED ACCESSIBLE SPACES. | | | | | | 19) SEE COMMENT #7. | | | | | | 20) COMPLIED. THE EXIT DOOR SIZE AND CALCULATIONS ARE | | | NOT PROVIDED FOR THE EXIT DISCHARGE DOOR AT THE EXIT | | | PASSAGEWAY FOR STAIR #01 ON SHEET CD-01. | | | | | | 21) COMPLIED. ON SHEET CD-04, DEAD END PATH A IS NOT | | | IDENTIFIED. FBC 107.2.1 | | | | | | 22) COMPLIED. A PORTION OF PATH B IS MISSING ON THE | | | DRAWING. FBC 107.2.1 | | | | | | 23) COMPLIED. TRAVEL DISTANCE WAS CORRECTED. | | | | | | 24) COMPLIED. SHOW THE TRAVEL PATHS FROM THE POOL | | | DECK/POOL AREA TO THE EXITS. FBC 1017.3 | | | | | | 25) COMPLIED. THE NUMBER OF OCCUPANTS THAT WILL BE | | | USING EACH OF EXITS. FBC SECTION 1006 AND FBC 107.2.1.2 | | | | | | 26) COMPLIED. THE OCCUPANT LOADS ARE TOTALS AND THE | | | DISPERSION OF OCCUPANTS TO EACH OF THE EXITS IS NOT | | | SHOWN ON THE PLANS. SHOW THE NUMBER OF OCCUPANTS FOR | | | EACH ROOM OR AREA AND WHICH EXIT THEY WILL USE. FBC | | | 107.2.1 | | | | | | 27) COMPLIED. SHOW THE EGRESS PATHS AND EXIT DOORS FOR | | | THE OUTDOOR TERRACE, CLUBROOM, FITNESS ROOM AND AMENITY | | | DECK SHOWN ON SHEET CD-04. FBC 1007 | | | | | | 28) COMPLIED. THE EXIT DOOR TO STAIR #03 FROM THE POOL | | | DECK ON LEVEL 4 IS SPECIFIED WITH A WITH A 19 INCH | | | CLEAR WIDTH. FBC 1010.1.1 REQUIRES A MINIMUM CLEAR | | | OPENING WIDTH OF 32 INCHES. THE SIZES FOR THE DOORS TO | | | THIS STAIR ARE NOT PROVIDED ON LEVELS 2 AND 3. FBC | | | 107.2.1 | | | | | | 29) NOT COMPLIED. ON SHEET CD-02, THE EXIT DOOR TO | | | STAIR 01 HAS INCORRECT AND MISSING INFORMATION. FBC | | | 107.2.1 | | | | | | 30) COMPLIED. SHOW THE EXIT PATHS OF TRAVEL AND TRAVEL | | | DISTANCES FOR EACH LEVEL OF THE GARAGE. FBC 1006 | | | | | | 31) COMPLIED. THE FIRST LEVEL OF THE PARKING GARAGE IS | | | ENCLOSED WITH MECHANICAL VENTILATION REQUIRED. THE | | | SECOND AND THIRD LEVELS ARE AN OPEN GARAGE. FBC TABLE | | | 705.8 FOOTNOTE "G" ALLOWS UNLIMITED OPENINGS IN OPEN | | | PARKING STRUCTURES WHICH APPLIES TO LEVEL 2 AND 3 OF | | | THE GARAGE. THE WEST ELEVATION IS 10'-1" FROM THE | | | PROPERTY LINE WHICH IS ALSO THE FIRE SEPARATION | | | DISTANCE. TABLE 705.8 ALLOWS A SPRINKLERED BUILDING | | | THAT HAS 10 FEET TO 15 FEET OF FIRE SEPARATION DISTANCE | | | TO HAVE 45 PERCENT OF THE WALL AREA OF EACH STORY TO BE | | | OPEN. PLEASE PROVIDE THE CALCULATIONS FOR THE ALLOWABLE | | | OPEN AREA OF EACH OF STORIES OTHER THAN THE OPEN LEVELS | | | OF THE PARKING GARAGE FOR THE WEST ELEVATION AND THE | | | PORTION OF THE SOUTH ELEVATION THAT IS 10' 1-7/8" FROM | | | THE PROPERTY LINE TO SHOW COMPLIANCE WITH FBC 705.8. | | | | | | 32) NOT COMPLIED. THE HANDRAIL EXTENSION AT THE BOTTOM | | | OF STAIRS ARE REQUIRED TO EXTEND AT THE SLOPE OF THE | | | STAIR FLIGHT FOR A HORIZONTAL DISTANCE AT LEAST EQUAL | | | TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. SEE | | | FBC ACCESSIBILITY SECTION 505.10.3. IT IS SHOWN WITH A | | | HORIZONTAL EXTENSION ON THE STAIR SECTION ON SHEETS | | | A7-01, A7-03 | | | | | | 33) COMPLIED. FBC 913.2.1 REQUIRES THE FIRE PUMP ROOM | | | TO BE SEPARATED FROM ALL OTHER AREAS OF THE BUILDING BY | | | 2-HOUR FIRE BARRIERS. | | | | | | 34) COMPLIED. THE TRASH CHUTE DISCHARGE ROOM HAS A 2 | | | HOUR FIRE RATING. | | | | | | 35) NOT COMPLIED. HANDRAIL IS SHOWN WITH A HORIZONTAL | | | EXTENSION RATHER THAN EXTENDING AT THE SLOPE OF THE | | | STAIRS. WITH A STAIR NUMBER FOUR ON SHEET A7-04 DOES | | | NOT HAVE THE REQUIRED HANDRAIL EXTENSION AT THE BOTTOM | | | OF STAIRS. HANDRAILS ARE REQUIRED TO EXTEND AT THE | | | SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE AT | | | LEAST EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER | | | NOSING. SEE FBC ACCESSIBILITY SECTION 505.10.3. | | | | | | 36) COMPLIED. PROVIDE AREA TABULATIONS FOR THE ENTIRE | | | BUILDING. FBC 107.2.1.2 | | | | | | 37) NOT COMPLIED. REQUEST TO DEFER HAS NOT BEEN | | | RECEIVED. FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT | | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. | | | | | | 38) NOT COMPLIED. REQUEST TO DEFER HAS NOT BEEN | | | RECEIVED. FBC 107.3.4.1 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 39) NOT COMPLIED. SHOW COMPLIANCE FBC ACCESSIBILITY | | | SECTION 242 FOR ACCESSIBLE ENTRY INTO THE POOL OR | | | SPECIFY ON THE PLANS WHY IT IS NOT REQUIRED. COMMUNITY | | | POOLS THAT ARE ASSOCIATED WITH A PRIVATE RESIDENTIAL | | | COMMUNITY THAT DO NOT RECEIVE GOVERNMENTAL FINANCIAL | | | ASSISTANCE OR SPONSORSHIP AND ARE LIMITED TO THE | | | EXCLUSIVE OF RESIDENTS AND THEIR GUESTS ARE NOT COVERED | | | BY THE ADA ACCESSIBILITY REQUIREMENTS, INCLUDING | | | PROVISIONS FOR POOL LIFTS OR SLOPED ENTRIES. IF A | | | SWIMMING POOL LOCATED IN A RESIDENTIAL COMMUNITY IS | | | MADE AVAILABLE TO THE PUBLIC FOR RENTAL OR USE IT IS | | | REQUIRED TO COMPLY WITH TITLE II OF THE ADA. SPECIFY ON | | | THE PLANS THE FORMER OR SHOW COMPLIANCE WITH THE LATTER | | | STATEMENTS. SEE DECLARATORY STATEMENT, DS 2013-011. | | | | | | 40) NOT COMPLIED. SEPARATE PERMITS, REVIEWS AND FEES | | | ARE REQUIRED FOR SOME ITEMS THAT MAY HAVE BEEN INCLUDED | | | IN THE VALUE FOR THIS PROJECT. ITEMS SUCH AS FIRE | | | ALARM, FIRE SPRINKLER, LOW VOLTAGE, LANDSCAPING, | | | IRRIGATION AND ALL ITEMS OTHER THAN BUILDING, | | | MECHANICAL, ELECTRIC AND PLUMBING. PLEASE PROVIDE A | | | COST BREAKDOWN SO THAT WE CAN DEDUCT THESE ITEMS FROM | | | THE PERMIT VALUE SO THAT YOU WILL NOT BE CHARGED TWICE | | | FOR THE SAME ITEM. | | | | | | 41) COMPLIED. THE REST./RETAIL AREAS ON THE GROUND | | | FLOOR HAVE DOORS THAT OPEN INTO THE PARKING GARAGE. IT | | | APPEARS THAT THESE ARE MEANT TO BE REQUIRED EXITS. | | | TABLE 508.4 REQUIRES A ONE HOUR FIRE SEPARATION BETWEEN | | | S-2 AND M OR B OCCUPANCIES IN A SPRINKLERED BUILDING. | | | IF THESE ARE REQUIRED EXITS THEY WILL BE REQUIRED TO BE | | | CONNECTED TO A ONE HOUR RATED CORRIDOR SEPARATING THEM | | | FROM THE PARKING GARAGE AND DISCHARGING TO THE EXTERIOR | | | OF THE BUILDING. | | | | | | 42) NEW COMMENT. WIND VELOCITY IS SPECIFIED AS 180 MPH | | | ON CD 01- CD06 PLANS IN BUILDING CODE DATA UNDER RISK | | | CATEGORY. THE STRUCTURAL PLANS SPECIFY A 175 MPH VULT | | | WINDSPEED. THE ACTUAL VULT WINDSPEED FOR WEST PALM | | | BEACH IS 170 MPH. CITY AMENDMENTS SECTION 120. PLEASE | | | COORDINATE. | | | | | | 43) THE DIAGONAL DISTANCE FOR SUITE 300 ON THE GROUND | | | LEVEL DID NOT USE THE MAXIMUM OVERALL DIAGONAL | | | DIMENSION OF THE AREA TO DETERMINE EXIT SEPARATION | | | DISTANCE. PLEASE CORRECT. FBC 1007.1.1 | | | | | | 44) THE 1/3 OF THE DIAGONAL DISTANCE IN THE LEASING | | | AREA IS INCORRECT. ONE THIRD OF 80'-4" IS 26'-9 ". FBC | | | 107.2.1 | | | | | | 45) THE EXIT TRAVEL DISTANCE FOR PATH A AT LEVEL 01 | | | SHOULD BE FROM THE MOST REMOTE POINT TO THE NEAREST | | | EXIT. IT APPEARS THAT THE NORTHWEST CORNER OF THE BIKE | | | STORAGE AREA WOULD BE THE MOST REMOTE POINT. FBC 1017.3 | | | | | | 46) PLEASE PROVIDE A RESPONSE LETTER ADDRESSING HOW | | | EACH OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-10 |
Time |
19:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-21 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2020-03-06 14:10:11 | PLAN REVIEW COMMENTS | | | THRESHOLD BUILDING | | | 8 STORY APARTMENT BUILDING (MIXED USE M, S-2, R-2, A-3 | | | AND B) | | | CONST. TYPE 1-A, SPRINKLERED | | | 170 MPH, EXPOSURE "D" | | | FLOOD ZONE "X" | | | 625 S. OLIVE AVE. | | | PERMIT #20011267 | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ART IN PUBLIC PLACES | | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. PER | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND CITY | | | OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, ART | | | IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. PER CITY OF WEST PALM BEACH | | | CODE OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, | | | SECTION 78-122, RENOVATION AND NEW CONSTRUCTION | | | PROJECTS ARE ASSESSED CUMULATIVELY, SO THE ART | | | ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE PROJECTS. | | | FOR INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR AT | | | 822-1515 OR E-MAIL: [email protected] | | | | | | 2) THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION | | | PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | | IN BLACK & WHITE. | | | G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR | | | THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS | | | REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, | | | APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND | | | CEILINGS. | | | J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT ( OCTOBER | | | 2018 ) CITY GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT | | | INSPECTORS. | | | | | | 3) THE GEOTECHNICAL REPORT THAT WAS SUBMITTED INDICATES | | | THAT THE RECOMMENDED VIBRO COMPACTION SOIL PREPARATION | | | WILL PRODUCE A SOIL BEARING VALUE OF UP TO 6,000 PSF. | | | NOTE 3A ON SHEET S200 OF THE PLANS STATES THAT THE | | | BUILDING DESIGN REQUIRES A SOIL BEARING CAPACITY OF | | | 8,000 PSF. PLEASE INDICATE HOW THIS WILL BE ADDRESSED. | | | FBC 1801.2 | | | | | | 4) SPECIFY HOW COMPLIANCE WITH FBC CHAPTER 33 | | | SAFEGUARDS DURING CONSTRUCTION FOR THE FOUNDATION | | | PERMIT WILL BE MET. | | | | | | 5) FBC 3002.4 REQUIRES ANY BUILDING THAT IS MORE THAN | | | THREE STORIES HIGH OR IN WHICH THE VERTICAL DISTANCE | | | BETWEEN THE BOTTOM TERMINAL LANDING AND THE TOP | | | TERMINAL LANDING EXCEEDS 25 FEET TO BE CONSTRUCTED TO | | | CONTAIN AT LEAST ONE PASSENGER ELEVATOR THAT IS | | | OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE DEPARTMENT | | | ACCESS TO ALL FLOORS. THE ELEVATOR CAR SHALL BE OF A | | | SIZE AND ARRANGEMENT TO ACCOMMODATE AN AMBULANCE | | | STRETCHER 24 INCHES BY 76 INCHES WITH NOT LESS THAN | | | 5-INCH RADIUS CORNERS, IN THE HORIZONTAL, OPEN POSITION | | | AND SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL FOR | | | EMERGENCY MEDICAL SERVICES (STAR OF LIFE). | | | | | | 6) THE TRASH CHUTE DISCHARGE ROOM IS REQUIRED TO BE | | | SEPARATED BY FIRE BARRIERS WITH A FIRE-RESISTANCE | | | RATING NOT LESS THAN THE REQUIRED FIRE RATING OF THE | | | SHAFT ENCLOSURE. FBC 713.13.4 | | | | | | 7) THE EXIT PASSAGEWAY AT STAIR 01 IS INCORRECTLY | | | LABELED AS AN EXIT ACCESS CORRIDOR. AN EXIT PASSAGEWAY | | | IS AN EXTENSION OF THE ENCLOSED INTERIOR EXIT STAIRWAY | | | AND HAS REQUIREMENTS SIMILAR TO THE STAIRWAY. PLEASE | | | CORRECT. SEE FBC 1023.1 AND 1024. | | | | | | 8) PROVIDE A SITE PLAN WITH ELEVATIONS SHOWN IN NAVD | | | 88. THERE WAS ONE WITH THE FOUNDATION PLAN, BUT IT | | | APPEARS TO BE MISSING FROM THESE DOCUMENTS. FBC | | | 107.2.1.2 | | | PLEASE REVIEW THE ELEVATIONS OF THE GRADE AROUND THE | | | EXTERIOR OF THE BUILDING AND COMPARE THEM WITH THE | | | FLOOR ELEVATION (11.97') OF THE BUILDING TO MAKE SURE | | | THAT THE EXITS DISCHARGE AT GRADE AND THE ELEVATIONS | | | AND SLOPES OF LANDINGS AND WALK WAYS WILL MEET THE | | | RUNNING SLOPE AND CROSS SLOPE REQUIREMENTS OF THE | | | FLORIDA ACCESSIBILITY CODE SECTION 403. | | | | | | 9) THE AR-RENDERINGS APPEAR TO BE MISLABELED. PLEASE | | | CLARIFY. FBC 107.2.1 | | | | | | 10) FBC TABLE 602 REQUIRES MERCANTILE OCCUPANCIES TO | | | HAVE 2 HOUR FIRE RESISTANCE RATED EXTERIOR WALLS FOR | | | LESS THAN 10 FT OF FIRE SEPARATION DISTANCE. THIS IS | | | NOT REFLECTED IN THE CODE DATA ON SHEET CD-1. HOWEVER, | | | THIS DOES NOT APPEAR TO BE AN ISSUE FOR YOUR PROJECT. | | | | | | 11) ON SHEET CD-01 AND THE OTHER EXISTING PLANS THE | | | RISK CATEGORY IN CODE DATA TABLE HAS BROWARD COUNTY AND | | | THIS PROJECT IS LOCATED IN PALM BEACH COUNTY. PLEASE | | | CORRECT. FBC 107.2.1 | | | | | | 12) PLEASE REMOVE THE RED DASHED CIRCLES FROM THE | | | EXITING PLANS ON SHEETS CD-01 AND CD-02. THEY MAKE THE | | | DRAWINGS DIFFICULT TO REVIEW. FBC 107.2.1.3 | | | | | | 13) THERE IS A STAIR #04 SHOWN ON THE PLANS BETWEEN THE | | | 2ND AND 3RD LEVELS OF THE PARKING GARAGE WITH A NOTE | | | (WHICH IS MISLABELED AS STAIR 03 ON CD-02) THAT IT IS | | | TO PREVENT A DEAD END CONDITION AT LEVEL 3. PLEASE | | | CLARIFY. | | | | | | 14) THE COMMERCIAL AREAS ON THE GROUND FLOOR EXITING | | | PLAN ARE LABELED RESTAURANT/RETAIL AND THE OCCUPANT | | | LOADS PROVIDED ARE FOR MERCANTILE. A RESTAURANT WOULD | | | BE AN A-2 ASSEMBLY OCCUPANCY WITH AN OCCUPANT LOAD OF | | | 15 NET WHICH WOULD BE MORE THAN THE 60 SQFT FOR | | | MERCANTILE. PLEASE USE THE MOST RESTRICTIVE OCCUPANT | | | LOAD. FBC 1004.1 | | | | | | 15) THE COVERED OUTDOOR RESTAURANT SEATING SHOULD BE | | | LABELED A-2 RATHER THAN A-3 PER FBC 303.3. PLEASE | | | CORRECT. | | | | | | 16) SHOW COMPLIANCE WITH FBC 3002.4 FOR THE REQUIREMENT | | | TO PROVIDE AN ELEVATOR CAR THAT WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 24" X 76". | | | | | | 17) VERIFY THE REQUIRED VERTICAL CLEARANCE OF 98 INCHES | | | FOR THE VAN PARKING SPACE, ACCESS AISLE AND VEHICULAR | | | ROUTE SERVING IT AS REQUIRED BY FBC ACCESSIBILITY | | | SECTION 502.5. | | | | | | 18) THE PARKING DATA ON SHEET GN-00 HAS 20 COMMERCIAL | | | SPACES AND 183 RESIDENTIAL SPACES. TABLE 208.2 IN THE | | | FBC ACCESSIBILITY REQUIRES A MINIMUM OF 1 ACCESSIBLE | | | PARKING SPACE WHEN THE TOTAL NUMBER OF SPACES PROVIDED | | | IS 1 TO 25. THE FAIR HOUSING GUIDELINES REQUIRE AT | | | LEAST 2 PERCENT OF THE COVERED RESIDENTIAL UNITS TO | | | HAVE ACCESSIBLE PARKING WHICH IS 4 SPACES. THIS PROJECT | | | IS REQUIRED TO HAVE A MINIMUM OF 5 ACCESSIBLE PARKING | | | SPACES. THE PLANS SHOW ONLY 4 ACCESSIBLE SPACES. | | | SECTION 208.2.4 REQUIRES AT LEAST ONE VAN PARKING SPACE | | | COMPLYING WITH SECTION 502 FOR EVERY SIX OR FRACTION OF | | | SIX REQUIRED ACCESSIBLE SPACES. | | | | | | 19) PLEASE LABEL THE EXIT PASSAGEWAY THAT CONNECTS | | | STAIR #01 TO THE EXIT DISCHARGE. SEE FBC SECTION 1024 | | | FOR THE REQUIREMENTS OF AN EXIT PASSAGEWAY WHICH | | | EXTENDS THE INTERIOR EXIT STAIRS TO THE EXTERIOR OF THE | | | BUILDING AND IS TREATED THE SAME AS AN ENCLOSED EXIT | | | STAIR WAY. | | | | | | 20) THE EXIT DOOR SIZE AND CALCULATIONS ARE NOT | | | PROVIDED FOR THE EXIT DISCHARGE DOOR AT THE EXIT | | | PASSAGEWAY FOR STAIR #01 ON SHEET CD-01. | | | | | | 21) ON SHEET CD-04, DEAD END PATH A IS NOT IDENTIFIED. | | | FBC 107.2.1 | | | | | | 22) A PORTION OF PATH B IS MISSING ON THE DRAWING. FBC | | | 107.2.1 | | | | | | 23) THE EXIT ACCESS TRAVEL DISTANCE IS MEASURED FROM | | | THE MOST REMOTE POINT WITHIN A STORY ALONG THE NATURAL | | | AND UNOBSTRUCTED PATH OF EGRESS TRAVEL TO AN EXIT. THE | | | MOST REMOTE POINT WOULD BE FROM THE CORNER OF THE | | | BALCONIES IN THE ROOMS. FBC 1017.3 | | | | | | 24) SHOW THE TRAVEL PATHS FROM THE POOL DECK/POOL AREA | | | TO THE EXITS. FBC 1017.3 | | | | | | 25) IN ADDITION TO THE EXIT CAPACITY AT EACH EXIT DOOR | | | ON THE FLOOR, INDICATE THE NUMBER OF OCCUPANTS THAT | | | WILL BE USING EACH OF EXITS. FBC SECTION 1006 AND FBC | | | 107.2.1.2 | | | | | | 26) THE OCCUPANT LOADS ARE TOTALS AND THE DISPERSION OF | | | OCCUPANTS TO EACH OF THE EXITS IS NOT SHOWN ON THE | | | PLANS. SHOW THE NUMBER OF OCCUPANTS FOR EACH ROOM OR | | | AREA AND WHICH EXIT THEY WILL USE. FBC 107.2.1 | | | | | | 27) SHOW THE EGRESS PATHS AND EXIT DOORS FOR THE | | | OUTDOOR TERRACE, CLUBROOM, FITNESS ROOM AND AMENITY | | | DECK SHOWN ON SHEET CD-04. FBC 1007 | | | | | | 28) THE EXIT DOOR TO STAIR #03 FROM THE POOL DECK ON | | | LEVEL 4 IS SPECIFIED WITH A WITH A 19 INCH CLEAR WIDTH. | | | FBC 1010.1.1 REQUIRES A MINIMUM CLEAR OPENING WIDTH OF | | | 32 INCHES. THE SIZES FOR THE DOORS TO THIS STAIR ARE | | | NOT PROVIDED ON LEVELS 2 AND 3. FBC 107.2.1 | | | | | | 29) THE DOORS TO OTHER STAIRS ARE MISSING EGRESS | | | INFORMATION ALSO. FBC 107.2.1 | | | | | | 30) SHOW THE EXIT PATHS OF TRAVEL AND TRAVEL DISTANCES | | | FOR EACH LEVEL OF THE GARAGE. FBC 1006 | | | | | | 31) THE FIRST LEVEL OF THE PARKING GARAGE IS ENCLOSED | | | WITH MECHANICAL VENTILATION REQUIRED. THE SECOND AND | | | THIRD LEVELS ARE AN OPEN GARAGE. FBC TABLE 705.8 | | | FOOTNOTE "G" ALLOWS UNLIMITED OPENINGS IN OPEN PARKING | | | STRUCTURES WHICH APPLIES TO LEVEL 2 AND 3 OF THE | | | GARAGE. THE WEST ELEVATION IS 10'-1" FROM THE PROPERTY | | | LINE WHICH IS ALSO THE FIRE SEPARATION DISTANCE. TABLE | | | 705.8 ALLOWS A SPRINKLERED BUILDING THAT HAS 10 FEET TO | | | 15 FEET OF FIRE SEPARATION DISTANCE TO HAVE 45 PERCENT | | | OF THE WALL AREA OF EACH STORY TO BE OPEN. PLEASE | | | PROVIDE THE CALCULATIONS FOR THE ALLOWABLE OPEN AREA OF | | | EACH OF STORIES OTHER THAN THE OPEN LEVELS OF THE | | | PARKING GARAGE FOR THE WEST ELEVATION AND THE PORTION | | | OF THE SOUTH ELEVATION THAT IS 10' 1-7/8" FROM THE | | | PROPERTY LINE TO SHOW COMPLIANCE WITH FBC 705.8. | | | | | | 32) THE HANDRAIL EXTENSION AT THE BOTTOM OF STAIRS ARE | | | REQUIRED TO EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR | | | A HORIZONTAL DISTANCE AT LEAST EQUAL TO ONE TREAD DEPTH | | | BEYOND THE LAST RISER NOSING. SEE FBC ACCESSIBILITY | | | SECTION 505.10.3. IT IS SHOWN WITH A HORIZONTAL | | | EXTENSION ON THE STAIR SECTION ON SHEET A7-01, A7-03 | | | | | | 33) FBC 913.2.1 REQUIRES THE FIRE PUMP ROOM TO BE | | | SEPARATED FROM ALL OTHER AREAS OF THE BUILDING BY | | | 2-HOUR FIRE BARRIERS. | | | | | | 34) THE TRASH (WASTE) CHUTE IS REQUIRED TO DISCHARGE | | | INTO AN ENCLOSED ROOM SEPARATED BY FIRE BARRIERS WITH A | | | FIRE-RESISTANCE RATING NOT LESS THAN THE REQUIRED FIRE | | | RESISTANCE RATING OF THE SHAFT ENCLOSURE PER FBC | | | 713.13.4. | | | | | | 35) STAIR NUMBER FOUR ON SHEET A7-04 DOES NOT HAVE THE | | | REQUIRED HANDRAIL EXTENSION AT THE BOTTOM OF STAIRS. | | | HANDRAILS ARE REQUIRED TO EXTEND AT THE SLOPE OF THE | | | STAIR FLIGHT FOR A HORIZONTAL DISTANCE AT LEAST EQUAL | | | TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. SEE | | | FBC ACCESSIBILITY SECTION 505.10.3. | | | | | | 36) PROVIDE AREA TABULATIONS FOR THE ENTIRE BUILDING. | | | FBC 107.2.1.2 | | | | | | 37) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. | | | | | | 38) FBC 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES | | | OF THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS | | | THOSE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT | | | THE TIME OF THE APPLICATION AND THAT ARE TO BE | | | SUBMITTED TO THE BUILDING OFFICIAL WITHIN A SPECIFIED | | | PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE | | | PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 39) SHOW COMPLIANCE FBC ACCESSIBILITY SECTION 242 FOR | | | ACCESSIBLE ENTRY INTO THE POOL OR SPECIFY ON THE PLANS | | | WHY IT IS NOT REQUIRED. COMMUNITY POOLS THAT ARE | | | ASSOCIATED WITH A PRIVATE RESIDENTIAL COMMUNITY THAT DO | | | NOT RECEIVE GOVERNMENTAL FINANCIAL ASSISTANCE OR | | | SPONSORSHIP AND ARE LIMITED TO THE EXCLUSIVE OF | | | RESIDENTS AND THEIR GUESTS ARE NOT COVERED BY THE ADA | | | ACCESSIBILITY REQUIREMENTS, INCLUDING PROVISIONS FOR | | | POOL LIFTS OR SLOPED ENTRIES. IF A SWIMMING POOL | | | LOCATED IN A RESIDENTIAL COMMUNITY IS MADE AVAILABLE TO | | | THE PUBLIC FOR RENTAL OR USE IT IS REQUIRED TO COMPLY | | | WITH TITLE II OF THE ADA. SPECIFY ON THE PLANS THE | | | FORMER OR SHOW COMPLIANCE WITH THE LATTER STATEMENTS. | | | SEE DECLARATORY STATEMENT, DS 2013-011. | | | | | | 40) SEPARATE PERMITS, REVIEWS AND FEES ARE REQUIRED FOR | | | SOME ITEMS THAT MAY HAVE BEEN INCLUDED IN THE VALUE FOR | | | THIS PROJECT. ITEMS SUCH AS FIRE ALARM, FIRE SPRINKLER, | | | LOW VOLTAGE, LANDSCAPING, IRRIGATION AND ALL ITEMS | | | OTHER THAN BUILDING, MECHANICAL, ELECTRIC AND PLUMBING. | | | PLEASE PROVIDE A COST BREAKDOWN SO THAT WE CAN DEDUCT | | | THESE ITEMS FROM THE PERMIT VALUE SO THAT YOU WILL NOT | | | BE CHARGED TWICE FOR THE SAME ITEM. | | | | | | 41) THE REST./RETAIL AREAS ON THE GROUND FLOOR HAVE | | | DOORS THAT OPEN INTO THE PARKING GARAGE. IT APPEARS | | | THAT THESE ARE MEANT TO BE REQUIRED EXITS. TABLE 508.4 | | | REQUIRES A ONE HOUR FIRE SEPARATION BETWEEN S-2 AND M | | | OR B OCCUPANCIES IN A SPRINKLERED BUILDING. IF THESE | | | ARE REQUIRED EXITS THEY WILL BE REQUIRED TO BE | | | CONNECTED TO A ONE HOUR RATED CORRIDOR SEPARATING THEM | | | FROM THE PARKING GARAGE AND DISCHARGING TO THE EXTERIOR | | | OF THE BUILDING. | | | | | | 42) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-20 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-20 |
Time |
17:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-05-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-18 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-15 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2020-05-18 11:19:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5.CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED. | | | 12. SHEET E2-04 SHOWS LIGHTING BEING INSTALLED WITHIN 5 | | | FEET OF THE POOL. WHAT IS THE HEIGHT OF THESE FIXTURES? | | | LIGHTING SHALL NOT BE INSTALLED AT A HEIGHT LESS THAN | | | 12 FEET WHEN WITHIN 5 FEET OF THE INSIDE WALL OF THE | | | POOL. PROVIDE CLARIFICATION AND/OR CORRECTION. NEC | | | 680.22(B)(1) (RESPONSE INDICATES THAT THE LIGHT | | | FIXTURES WILL BE INSTALLED AT A HEIGHT ABOVE POOL DECK | | | OF AT LEAST 7 FEET. THIS IS NOT CODE COMPLIANT, A | | | MINIMUM OF 12 FEET IS REQUIRED. PROVIDE CLARIFICATION | | | AND/OR CORRECTION.) | | | 13. CORRECTED. | | | 14. CORRECTED. | | | 15. CORRECTED. | | | 16. CORRECTED. | | | 17. FOR POOL ROOM EQUIPMENT, PROVIDE ENCLOSURE TYPES | | | DESIGNED TO PROTECT AGAINST CORROSIVE ENVIRONMENTS. NEC | | | TABLE 110.28 (DUE TO THE CORROSIVE ENVIRONMENTS OF THE | | | POOL EQUIPMENT ROOM, A MINIMUM OF NEMA 3X IS REQUIRED. | | | PROVIDE CORRECTION.) | | | 18. CORRECTED. | | | 19. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-03-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-11 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-10 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2020-03-11 09:03:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING | | | PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK | | | IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY | | | OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1 | | | 2. PROVIDE ACKNOWLEDGEMENT THAT EMERGENCY RESPONDER | | | RADIO COVERAGE WILL BE SUPPLIED UNDER SEPARATE PERMIT. | | | FBC 403.4.5; WPB FBC 107.2.1 | | | 3. RISER DIAGRAM DOES NOT CONTAIN INFORMATION FOR THE | | | SERVICE TO THE FIRE PUMP. PROVIDE CORRECTION. NEC | | | 215.5; WPB FBC 107.2.1 | | | 4. PROVIDE MULTIPLE SOURCES FOR RELIABLE POWER TO THE | | | FIRE PUMP. NEC 695.3(B) | | | 5. PROVIDE STANDBY AND EMERGENCY POWER FOR STANDBY | | | POWER LOADS SPECIFIED IN FBC 403.4.8.3 AND EMERGENCY | | | POWER LOADS SPECIFIED IN FBC 403.4.8.4. FBC 403.4.8 | | | 6. RISER DIAGRAM INDICATES THAT EXCEPTION 3 TO NEC | | | 230.90(A) WILL BE USED FOR THE 6000 AMP DISTRIBUTION | | | CENTER, BUT NO DETAILS ARE PROVIDED ABOUT THE | | | OVERCURRENT PROTECTION IN THIS EQUIPMENT. THE 6 MAINS | | | PERMITTED ARE REQUIRED TO BE GROUPED IN THE SAME | | | LOCATION. PROVIDE CLARIFICATION AND/OR CORRECTIONS AS | | | NEEDED. PROVIDE PANEL SCHEDULE FOR THIS DISTRIBUTION | | | EQUIPMENT TO CONFIRM CODE COMPLIANCE. WPB FBC 107.2.1; | | | NEC 230.90, 230.72 | | | 7. PROVIDE NAME OF METER CENTERS ON THE METER CENTER. | | | THE LOAD CALCULATION FOR EACH METER CENTER ARE SHOWN | | | TOGETHER, SO IT IS UNCLEAR WHICH CALCULATION IS FOR | | | WHICH METER CENTER. WPB FBC 107.2.1 | | | 8. PROVIDE LOAD CALCULATION FOR EACH BUSWAY FEEDING THE | | | METER CENTERS. WPB FBC 107.2.1; NEC 215.2, 220 | | | 9. PROVIDE CONDUCTOR SIZE FEEDING EACH BUSWAY. WPB FBC | | | 107.2.1; NEC 215.2, 220 | | | 10. PROVIDE VOLTAGE DROP CALCULATIONS FOR EACH BUSWAY. | | | FBC EC C405.6.3 | | | 11. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT | | | SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2, | | | C405.2.1 | | | 12. SHEET E2-04 SHOWS LIGHTING BEING INSTALLED WITHIN 5 | | | FEET OF THE POOL. WHAT IS THE HEIGHT OF THESE FIXTURES? | | | LIGHTING SHALL NOT BE INSTALLED AT A HEIGHT LESS THAN | | | 12 FEET WHEN WITHIN 5 FEET OF THE INSIDE WALL OF THE | | | POOL. PROVIDE CLARIFICATION AND/OR CORRECTION. NEC | | | 680.22(B)(1) | | | 13. RISER DIAGRAM INDICATES AIC FAULT CURRENT IS | | | ASSUMED. PROVIDE ACTUAL AVAILABLE SHORT CIRCUIT | | | CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE | | | POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. AS AN | | | ALTERNATIVE, A BLOCK NOTE WILL BE ACCEPTED INDICATING | | | THIS WILL BE A DEFERRED SUBMITTAL PROVIDED PRIOR TO | | | RELEASE OF POWER. NEC 110.9, 110.10 | | | 14. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 15. PROVIDE BLOCK NOTE INDICATING COMPLIANCE: WITHIN 30 | | | DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD | | | DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDE TO | | | THE BUILDING OWNER, INCLUDING: 1. A SINGLE LINE DIAGRAM | | | OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND 2. | | | FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL | | | DISTRIBUTION. FBC EC C405.6.4.1 | | | 16. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FOR RESIDENTIAL | | | AREAS, A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | | ONLY HIGH EFFICACY LAMPS. FBC EC C405.1, C405.4.2 | | | 17. FOR POOL ROOM EQUIPMENT, PROVIDE ENCLOSURE TYPES | | | DESIGNED TO PROTECT AGAINST CORROSIVE ENVIRONMENTS. NEC | | | TABLE 110.28 | | | 18. PROVIDE DETAILS OF SELECTIVE COORDINATION PER NEC | | | 700.28 AND 701.27. | | | 19. PROVIDE DETAILS OF ARC ENERGY REDUCTION PER NEC | | | 240.87. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-07-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-14 16:14:23 | REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL E20020018. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2020-05-04 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-05-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-05-04 15:50:51 | UNDER FORMAL ENGINEERING REVIEW E20020018. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2020-03-10 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-03-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-03-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-03-10 07:19:36 | PLEASE ADDRESS ZONING COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2020-06-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-06-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-06-29 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2020-05-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-05-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-04-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2020-05-07 12:16:46 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | PREVIOUS COMMENTS NOT ADDRESSED: | | | | | | 5) SHEET A1-01 - THERE IS NO INDICATION OF A REQUIRED | | | FIRE RATING OF THE PET SPA WALLS. | | | | | | PER NFPA 101 CH 6 | | | | | | 6.1.14.3 MIXED OCCUPANCIES. | | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | | CLASSIFIED AS TO ITS USE IN | | | ACCORDANCE WITH SECTION 6.1. | | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | | RESTRICTIVE | | | REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS | | | SEPARATE SAFEGUARDS | | | ARE APPROVED. | | | 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.) | | | 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED, | | | EACH PART OF THE | | | BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED | | | IN THIS CHAPTER, | | | SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY | | | FIRE-RESISTIVE | | | ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3, | | | TABLE 6.1.14.4.1(A), | | | AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED | | | BY APPROVED | | | EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY | | | 6.1.14.4.6. | | | | | | PLEASE REVIEW AND COR | | | | | | | | | | | | | | | 7) SHEET A 1-04 - PLEASE PROVIDE THE DIMENSION IN | | | BETWEEN THE STRAIRWELLS SHOWING COMPLIANCE WITH THE | | | HOSELINE LENGHTS PER NFPA 14 | | | | | | 7.3.2.2* WHERE THE MOST REMOTE PORTION OF A | | | NONSPRINKLERED | | | FLOOR OR STORY IS LOCATED IN EXCESS OF 150 FT (45.7 M) | | | OF TRAVEL | | | DISTANCE FROM A HOSE CONNECTION IN OR ADJACENT TO A | | | REQUIRED | | | EXIT OR THE MOST REMOTE PORTION OF A SPRINKLERED FLOOR | | | OR STORY | | | IS LOCATED IN EXCESS OF 200 FT (61 M) OF TRAVEL | | | DISTANCE FROM A | | | HOSE CONNECTION IN OR ADJACENT TO A REQUIRED EXIT, | | | ADDITIONAL | | | HOSE CONNECTIONS SHALL BE PROVIDED, IN APPROVED | | | LOCATIONS, | | | WHERE REQUIRED BY THE LOCAL FIRE DEPARTMENT OR THE AHJ. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS OF COMPLIANCE OR | | | CORRECT | | | | | | | | | | | | NEW COMMENT: | | | | | | 1) THERE ARE SEVERAL FIREDAMPER/DUCT DETECTOR LOCATIONS | | | NOTED BY MECHANICAL PLAN REVIEWER THAT ARE REQUIRED AND | | | NEED TO BE ADDRESSED THAT WON'T BE REPEATED HERE TO | | | AVOID DUPLICATION. | | | | | | THOSE COMMENTS WILL BE MONITORED FOR CORRECTION. | | | | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-03-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-03-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-03-18 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2020-03-18 15:41:41 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) ALL A SHEETS - THERE ARE INDICATIONS OF THE COLOR | | | RED ON SOME WALLS HOWEVER, THERE ARE NO INDICATION OF | | | WHAT THOSE ABBREVIATED OR SOLID RED LINES MEANS | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 2) SHEET A1-01 - THERE ARE INDICATIONS OF A TRASH ROOM | | | HOWEVER, NO INDICATION OF ANY REQUIRED FIRE RATING OF | | | THE TRASH ROOM WALLS. | | | | | | PET NFPA 101, CH 30 | | | | | | 30.3.2 PROTECTION FROM HAZARDS. | | | 30.3.2.1 HAZARDOUS AREAS. ANY HAZARDOUS AREA SHALL BE | | | PROTECTED IN ACCORDANCE WITH SECTION 8.7. | | | 30.3.2.1.1 THE AREAS DESCRIBED IN TABLE 30.3.2.1.1 | | | SHALL BE | | | PROTECTED AS INDICATED. | | | | | | TRASH COLLECTION ROOMS 1 HOUR AND SPRINKLERS | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 3) SHEET CD 01 - THERE ARE INDICATIONS OF THE M SPACES | | | WITH AN OCCUPANT LOAD OF 60SF/OCC. | | | | | | PER NFPA 101 CH 7 - 60 IS USED FOR SALES AREAS ON | | | FLOORS ABOVE STREET FLOOR. 30 SHOULD BE USED FOR STREET | | | FLOOR SALES | | | | | | PLEASE REVIEW AND CORRECT OR PROVIDE A DETAILED | | | NARRATIVE AND SPECIFIC FIRE CODE. | | | | | | | | | | | | | | | 4) SHEET CD 01 - THERE ARE INDICATIONS THAT THE M | | | OCCUPANCY EXITS AT THE REAR INTO A S OCCUPANCY. | | | | | | EXITING INTO A HIGHER HAZARD OCCUPANCY IS NOT ALLOWED | | | IN THE FIRE CODE. | | | | | | | | | PER NFPA 101 CH 7 | | | | | | 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE | | | PERMITTED TO BE | | | THROUGH ADJOINING OR INTERVENING ROOMS OR AREAS, | | | PROVIDED THAT SUCH | | | ROOMS OR AREAS ARE ACCESSORY TO THE AREA SERVED. | | | FOYERS, LOBBIES, AND | | | RECEPTION ROOMS CONSTRUCTED AS REQUIRED FOR CORRIDORS | | | SHALL NOT BE | | | CONSTRUED AS INTERVENING ROOMS. EXIT ACCESS SHALL BE | | | ARRANGED SO | | | THAT IT IS NOT NECESSARY TO PASS THROUGH ANY AREA | | | IDENTIFIED UNDER | | | PROTECTION FROM HAZARDS IN CHAPTERS 11 THROUGH 43. | | | | | | PLEASE REVIEW AND CORRECT | | | | | | | | | 5) SHEET A1-01 - THERE IS NO INDICATION OF A REQUIRED | | | FIRE RATING OF THE PET SPA WALLS. | | | | | | PER NFPA 101 CH 6 | | | | | | 6.1.14.3 MIXED OCCUPANCIES. | | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | | CLASSIFIED AS TO ITS USE IN | | | ACCORDANCE WITH SECTION 6.1. | | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | | RESTRICTIVE | | | REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS | | | SEPARATE SAFEGUARDS | | | ARE APPROVED. | | | 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.) | | | 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED, | | | EACH PART OF THE | | | BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED | | | IN THIS CHAPTER, | | | SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY | | | FIRE-RESISTIVE | | | ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3, | | | TABLE 6.1.14.4.1(A), | | | AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED | | | BY APPROVED | | | EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY | | | 6.1.14.4.6. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 6) SHEET A 1-04 & ALL FLOOR LEVELS ABOVE - PLEASE | | | PROVIDE THE DIMESION OF THE NORTH AND SOUTH DEAD-END | | | CORRIDOR SHOWING COMPLIANCE WITH NFPA 101 CH 30 | | | | | | 30.2.5.4.2 DEAD-END CORRIDORS SHALL NOT EXCEED 50 FT | | | (15 M) IN | | | BUILDINGS PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED | | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 30.3.5. | | | | | | PLEASE REVIEW AND PROVIDE | | | | | | | | | | | | 7) SHEET A 1-04 - PLEASE PROVIDE THE DIMENSION IN | | | BETWEEN THE STRAIRWELLS SHOWING COMPLIANCE WITH THE | | | HOSELINE LENGHTS PER NFPA 14 | | | | | | 7.3.2.2* WHERE THE MOST REMOTE PORTION OF A | | | NONSPRINKLERED | | | FLOOR OR STORY IS LOCATED IN EXCESS OF 150 FT (45.7 M) | | | OF TRAVEL | | | DISTANCE FROM A HOSE CONNECTION IN OR ADJACENT TO A | | | REQUIRED | | | EXIT OR THE MOST REMOTE PORTION OF A SPRINKLERED FLOOR | | | OR STORY | | | IS LOCATED IN EXCESS OF 200 FT (61 M) OF TRAVEL | | | DISTANCE FROM A | | | HOSE CONNECTION IN OR ADJACENT TO A REQUIRED EXIT, | | | ADDITIONAL | | | HOSE CONNECTIONS SHALL BE PROVIDED, IN APPROVED | | | LOCATIONS, | | | WHERE REQUIRED BY THE LOCAL FIRE DEPARTMENT OR THE AHJ. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS OF COMPLIANCE OR | | | CORRECT | | | | | | | | | | | | 8) SHEET A 1-04 - THE DOORS TO THE FITNESS ROOM ARE | | | INDICATED AS IN-SWING. | | | | | | PER NFPA 101 CH 7 | | | | | | 7.2.1.4.2 DOOR LEAF SWING DIRECTION. DOOR LEAVES | | | REQUIRED TO BE | | | OF THE SIDE-HINGED OR PIVOTED-SWINGING TYPE SHALL SWING | | | IN THE | | | DIRECTION OF EGRESS TRAVEL UNDER ANY OF THE FOLLOWING | | | CONDITIONS: | | | (1) WHERE SERVING A ROOM OR AREA WITH AN OCCUPANT LOAD | | | OF 50 OR | | | MORE, EXCEPT UNDER ANY OF THE FOLLOWING CONDITIONS: | | | (A) DOOR LEAVES IN HORIZONTAL EXITS SHALL NOT BE | | | REQUIRED TO | | | SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE PERMITTED | | | BY 7.2.4.3.8.1 OR 7.2.4.3.8.2. | | | (B) DOOR LEAVES IN SMOKE BARRIERS SHALL NOT BE REQUIRED | | | TO | | | SWING IN THE DIRECTION OF EGRESS TRAVEL IN EXISTING | | | HEALTH | | | CARE OCCUPANCIES, AS PROVIDED IN CHAPTER 19. | | | (2) WHERE THE DOOR ASSEMBLY IS USED IN AN EXIT | | | ENCLOSURE, UNLESS | | | THE DOOR OPENING SERVES AN INDIVIDUAL LIVING UNIT THAT | | | OPENS | | | DIRECTLY INTO AN EXIT ENCLOSURE | | | (3) WHERE THE DOOR OPENING SERVES A HIGH HAZARD | | | CONTENTS AREA | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 9)THIS IS A HIGH RISE BUILDING HOWEVER A FIRE COMMAND | | | ROOM COULD NOT BE READILY IDENTIFIED OR LOCATED. | | | | | | PER NFPA 1 & 101 | | | | | | 3.3.36.7* HIGH-RISE BUILDING. A BUILDING WHERE THE | | | FLOOR OF AN | | | OCCUPIABLE STORY IS GREATER THAN 75 FT (23 M) ABOVE THE | | | LOWEST | | | LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS. | | | | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | | | | PER NFPA 101 | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | | | | PLEASE REVIEW AND PROVIDE DETAILS. | | | | | | | | | | | | 10) THERE APPEARS TO BE NO CLEAR INDICATION OF ANY | | | SMOKE CONTROL SYSTEM(S). | | | | | | PLEASE PROVIDE DETAILS | | | | | | | | | | | | 11) SHEETS A7-20 & 21 - THERE ARE NO INDICATIONS OF | | | ELEVATORS THAT COMPLY WITH THE FIRE CODE | | | | | | PER NFPA 101 | | | | | | 30.5.3 ELEVATORS, ESCALATORS, AND CONVEYORS. ELEVATORS, | | | ESCALATORS, AND CONVEYORS SHALL COMPLY WITH THE | | | PROVISIONS OF | | | SECTION 9.4. | | | | | | 9.4.2 CODE COMPLIANCE. | | | 9.4.2.1 EXCEPT AS MODIFIED HEREIN, NEW ELEVATORS, | | | ESCALATORS, | | | DUMBWAITERS, AND MOVING WALKS SHALL BE IN ACCORDANCE | | | WITH THE | | | REQUIREMENTS OF ASME A17.1/CSA B44, SAFETY CODE FOR | | | ELEVATORS AND ESCALATORS. | | | | | | 9.4.3 FIRE FIGHTERS? EMERGENCY OPERATIONS. | | | 9.4.3.1 ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE | | | FIGHTERS? | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, | | | SAFETY CODE FOR ELEVATORS AND ESCALATORS. | | | 9.4.3.2 ALL EXISTING ELEVATORS HAVING A TRAVEL DISTANCE | | | OF 25 FT | | | (7620 MM) OR MORE ABOVE OR BELOW THE LEVEL THAT BEST | | | SERVES THE | | | NEEDS OF EMERGENCY PERSONNEL FOR FIRE-FIGHTING OR | | | RESCUE PURPOSES | | | SHALL CONFORM TO THE FIRE FIGHTERS? EMERGENCY | | | OPERATIONS | | | REQUIREMENTS OF ASME A17.3, SAFETY CODE FOR EXISTING | | | ELEVATORS | | | AND ESCALATORS. | | | | | | | | | 12) SHEETS A7-20 & 21 - PLEASE PROVIDE INDICATIONS FOR | | | COMPLIANCE OF THE ELEVATOR INTERIOR SIZE FOR EMS | | | STRETCHER DIMESIONS. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 13) SHEET E0-00 & ELECTRICAL SHEETS - THERE ARE | | | INDICATIONS OF FIRE ALARM DEVICES; HOWEVER, ALL FIRE | | | ALARM WORK SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT | | | | | | | | | | | | 14) ELECTRICAL SHEETS - THERE ARE NO INDICATIONS OF BDA | | | INSTALLATIONS FOR RADIO TWO-WAY COMMUNICATIONS PER NFPA | | | 72 | | | | | | A BDA PERMIT AND REPORT IS REQUIRED UNDER SPERATE | | | PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT | | | | | | | | | 15) SHEET FPO - THERE ARE INDICATIONS UNDER GENERAL | | | NOTE OF A FIRE SPRINKLER PERMIT. | | | | | | ALL FIRE SPRINKLER WORK SHALL BE DONE UNDER SEPARATE | | | PERMIT AND SHOP DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT | | | | | | | | | | | | 16) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 17 ) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-07-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-07-17 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-07-17 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2020-07-17 13:30:46 | DEFERRED SUBMITTALS FOR THE GAS INCLUDE THE | | | MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE GAS PRESSURE REGULATORS AND | | | SPECIFICATIONS FOR ALL GAS EQUIPMENT AND APPLIANCES. | | | TKL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-06-12 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-06-12 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2020-06-12 08:18:58 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE GAS PRESSURE | | | REGULATORS.REGULATORS INSTALLED ON THE EXTERIOR OF THE | | | BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION.2017 FBC-FUEL GAS SEC.410.1. | | | 2) SHT. P4-01 - TYPICAL DIRT LEG DETAIL - UPFEED TO | | | EQUIPMENT DIAGRAM - THE DRAWING IS INCOMPLETE. | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL GAS | | | EQUIPMENT. FBC-FUEL GAS SEC.301.3. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-03-09 |
Time |
05:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-03-09 |
Time |
05:56 |
Sent To |
|
|
| Notes |
| 2020-03-09 05:57:24 | GAS 1ST REVIEW**DENIED*20011267* NOTE - A COMPREHENSIVE | | | REVIEW COULD NOT BE DONE AT THIS TIME AND ADDITIONAL | | | PLAN REVIEW COMMENTS MAY BE GENERATED UPON THE | | | RE-REVIEW OF SUBMITTED CORRECTIONS | | | | | | 1) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. | | | 2) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1. | | | 3) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | 4) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | 5) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 | | | 6) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 | | | 7) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) | | | 8) SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS SEC.409.4 | | | 9) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1 | | | 10) ) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1 | | | | | | TIM HUNT | | | PLUMBING PLAN REVIEW | | | CITY OF WEST PALM BEACH (CGA SOLUTIONS) | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-08-17 |
|
|
Cont ID |
|
| Sent By |
rsklarew |
Date |
2020-08-17 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
rsklarew |
Date |
2020-08-17 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-10 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-30 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-21 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-22 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-06-12 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-04-20 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-03-19 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-14 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-08-05 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-09 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2020-08-05 09:46:08 | MU-2020-026209 - $468,545.67 - PAID - REMAINING FEES IN | | | ESCROW | | 2020-07-09 07:28:42 | 7/9/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-02-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-18 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-18 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2020-02-18 11:11:37 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-07-13 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-07-13 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-04-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-04-24 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-21 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2020-04-24 19:11:34 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #20011267 | | | 4/24/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | BASED ON THE RESUBMITTED PLANS AND RESPONSE NARRATIVE, | | | COMMENTS FROM THE 1ST REVIEW LISTED BELOW WILL BE | | | MARKED AS "OK", "APPROVED WITH EXCEPTION" OR AS | | | "DENIED" ACCORDINGLY. PLEASE COMPLY WITH ALL EXCEPTIONS | | | AND COMMENTS. PLEASE NOTE THE NEW COMMENTS ATTACHED AT | | | THE END OF THE REVIEW. | | | | | | 1) APPROVED WITH EXCEPTION- THE CALCULATIONS SHALL BE | | | ELECTRONICALLY SIGNED AND SEALED BY THE ENGINEER- FL. | | | STATUTE 471.025 AND SECTION 61G15-23.005 FAC. THE | | | SIGNATURE AND SEAL MAY BE PLACED ON THE COVER SHEET OF | | | THE CALCS. PLEASE SUBMIT THE ENTIRE PACKAGE AS A | | | SEPARATE DOCUMENT APART FROM THE COMMENT RESPONSE | | | DOCUMENT- SECTION 107.2.1 WPB. | | | | | | 2) OK. | | | | | | 3) DENIED- SHEET M5-01: PROVIDE BLOWER DOOR TESTING | | | NOTE ON THE PLAN PER THE NARRATIVE RESPONSE. "BLOWER | | | DOOR TESTING WILL BE CONDUCTED FOR EACH UNIT TYPE TO | | | VERIFY THE INFILTRATION RATES MEET THE MINIMUM AIR | | | CHANGE RATE REQUIRED FOR USE OF NATURAL VENTILATION". | | | PROVIDE NATURAL VENTILATION CALCULATIONS FOR EACH | | | APARTMENT MODEL- SECTION 402.2 FBC M. | | | | | | 4) DENIED: THE AREA OF THE 1ST FLOOR GARAGE BY THE | | | TRANSFORMER ROOM APPEARS ISOLATED FROM THE FAN ON THE | | | SOUTH WALL. PLEASE PLACE A NOTE THAT ON THE PLAN TO | | | INDICATE AN EXHAUST VENTILATION TEST WILL BE PERFORMED | | | TO INSURE THE EFFECTIVENESS OF THE SYSTEM- SECTIONS | | | 403.3.1.2 & 403.3.1.5 FBC M.M-101A: | | | | | | 5) DENIED- SHEETS A1-01A & M1-01A: THE GARAGE FAN IS | | | LOCATED IN A DRIVE AREA. PLEASE PROVIDE A MEANS OF | | | PROTECTION FROM VEHICLE IMPACT SUCH AS CURBING OR | | | BOLLARDS- SECTIONS 303.4 AND 304.6 FBC M. | | | | | | 6) OK- DEFERRED SUBMITTALS ACCEPTABLE FOR THE GARAGE CO | | | AND NO2 SENSORS. | | | | | | 7) DENIED- SHEET M-101.A: A) FIRE DAMPER MISSING AT THE | | | MAKEUP AIR DUCT PENETRATION OF THE FIRE-RATED PUMP ROOM | | | WALL- SECTION 607.5.2 FBC M. B) THE MAKEUP AIR INLET | | | OPENING CANNOT BE LOCATED ABOVE THE DRIVEWAY PER | | | SECTIONS 510.6.5 AND 401.4 FBC M. A MINIMUM 10' | | | HORIZONTAL CLEARANCE IS REQUIRED. C) VERIFY THE | | | UNDERSIDE OF THE MAKEUP AIR DUCT WILL BE A MINIMUM 8? | | | ABOVE THE GARAGE FLOOR- SECTION 304.6. D) THE L-3 | | | LOUVER SHALL BE AMCA 550 RATED IN ACCORDANCE WITH | | | SECTION 401.5 FBC M. SUBMIT MANUFACTURER?S | | | SPECIFICATIONS FOR THE GREENHECK EHH-501X TO VERIFY | | | COMPLIANCE. | | | | | | 8) OK. | | | | | | 9) DENIED- M1-01A: THE NOTE ON THE PLAN DOES NOT | | | INCLUDE THE REQUIRED 10' EXHAUST TERMINATION CLEARANCE | | | TO OPERABLE OPENINGS INTO THE BUILDING. A) THE L-4 | | | LOUVER SHALL BE AMCA 550 RATED IN ACCORDANCE WITH | | | SECTION 501.3.2 FBC M. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE GREENHECK EHH-501X TO VERIFY | | | COMPLIANCE. | | | | | | 10, 11, 12) APPROVED WITH EXCEPTION- PLEASE PLACE A | | | NOTE ON SHEET M0 INDICATING SEPARATE PERMITS AND PLANS | | | WILL BE SUBMITTED FOR: A) FIRE PUMP. B) DIESEL FUEL | | | TANK. C) FUEL PIPING. PLEASE SUBMIT THE CLARKE PUMP | | | ROOM VENTILATION CALCULATOR AS A SEPARATE DOCUMENT | | | APART FROM THE COMMENT RESPONSES- SECTION 107.2.1 WPB. | | | | | | 13) DENIED- M1-01A: FIRE DAMPER MISSING FOR THE TRASH | | | EXHAUST DUCT PENETRATING THE FIRE-RATED TRASH ROOM | | | WALL- SECTION 607.5.2 FBC M. | | | | | | 14) DENIED- M1-01A: SHOW THE LOCATIONS OF THE GRAVITY | | | DAMPERS AND PROVIDE A NOTE ON THE PLAN INDICATING THE | | | DAMPERS WILL BE AMCA 500D RATED PER SECTION C403.2.4.3 | | | FBC EC. THE DAMPERS MAY BE ADDED TO THE LIST OF | | | DEFERRED SUBMITTALS FOR THE PROJECT. A) THE L-5 O/A | | | INTAKE LOUVER SHALL BE AMCA 550 RATED IN ACCORDANCE | | | WITH SECTION 401.5 FBC M. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE GREENHECK EHH-501X TO VERIFY | | | COMPLIANCE. | | | | | | 15) DENIED- M1-01A: AIRFLOW PERFORMANCE DATA FOR THE | | | DAIKIN 5-TON AIR HANDLERS INDICATE THE BLOWERS CAN | | | PRODUCE OVER 2000 CFMS DEPENDING ON THE SETTING OF THE | | | BLOWER AND EXTERNAL STATIC PRESSURE WHICH CAN BE | | | ADJUSTED TO PRODUCE AS MUCH AS 2340 CFMS OF SUPPLY AIR. | | | PLEASE PROVIDE THE DUCT SMOKE DETECTORS IN THE SUPPLY | | | AIR SYSTEMS AHU 3 & 4- SECTION 606.2.1 FBC M. | | | | | | 16) OK. | | | | | | 17) DENIED- M1-01A & B: THE EXHAUST TERMINATION | | | LOCATION FOR THE GREASE DUCTS ARE SHOWN TO BE WITHIN | | | THE REQUIRED 10' CLEARANCE TO THE PROPERTY LINES- | | | SECTION 506.3.13.3 FBC M. THE EXHAUST TERMINATION | | | LOCATION FOR SUITE 100 IS NOT SHOWN- SECTION 107.2.1 | | | WPB. | | | | | | 18) APPROVED WITH EXCEPTION- M1-01A & B & M0: PLEASE | | | PROVIDE A MASTER LIST OF ALL SEPARATELY PERMITTED | | | SYSTEMS AND TENANT SPACES ON THE M0 PLAN, AND ADD THE | | | KITCHEN EXHAUST AND FIRE SUPPRESSION SYSTEMS, AND WALK | | | IN COOLERS AND FREEZERS TO THE LIST- SECTION 107.2.1 | | | WPB. | | | | | | 19) OK. | | | | | | 20) DENIED- M1-01B: THE LIFE SAFETY DOES NOT INDICATE | | | THAT THE COMMON WALLS SEPARATING THE PET | | | SPA/TRANSFORMER ROOM ARE FIRE-RESISTANT RATED- TABLE | | | 508.4 FBC B. | | | | | | 21) DENIED- M1-01B & M1-02B: THE INSTALLATION OF THE | | | OUTDOOR CONDENSERS ON THE INTERIOR OF THE BUILDING WILL | | | REQUIRE APPROVAL BY SUBMITTAL OF A MANUFACTURER'S | | | LETTER OR INSTALLATION GUIDELINES CONFIRMING THE | | | INSTALLATION IS APPROVED IN ACCORDANCE WITH THE LISTING | | | AND LABELING OF THE PRODUCT- SECTION 304.1 FBC M. | | | | | | 22, 24, 25) APPROVED WITH EXCEPTION- M1-03B & M0: THE | | | ENGINEER IS REQUESTING THE POOL EQUIPMENT ROOM AND ALL | | | ASSOCIATED EQUIPMENT AND APPLIANCES, VENTILATION | | | SYSTEM, STORAGE OF MATERIALS TO BE UNDER SEPARATE | | | PERMIT. PLEASE PLACE A NOTE ON THE PLAN AND ADD ALL | | | ITEMS TO THE MASTER LIST OF ALL SEPARATELY PERMITTED | | | SYSTEMS ON THE M0 PLAN- SECTION 107.2.1 WPB. | | | | | | 26) OK | | | | | | 27) DENIED- 2ND REQUEST M1-05A: FIRE DAMPERS ARE | | | MISSING FOR THE AHU-5 & 6 SUPPLY, RETURN, AND O/A DUCTS | | | PENETRATING THE FIRE-RATED MECHANICAL ROOM WALLS- | | | SECTION 607.5.2 FBC M. | | | | | | 28) DENIED 2ND REQUEST M1-05A: DUCT SMOKE DETECTORS ARE | | | REQUIRED IN THE SUPPLY AIR SYSTEMS OF THE 5-TON AHU 5 & | | | 6 SYSTEMS PER SECTION 606.2.1 FBC M. PLEASE NOTE THAT | | | AN EXEMPTION CAN BE APPLIED IF THE MANUFACTURER'S | | | SPECIFICATIONS INDICATE THE SYSTEMS ARE NOT CAPABLE OF | | | PRODUCING OVER 2000 CFMS OF SUPPLY AIR. | | | | | | 29) DENIED- M-105A: SHOW THE LOCATIONS OF THE O/A | | | GRAVITY DAMPERS AND PROVIDE A NOTE ON THE PLAN | | | INDICATING THE DAMPERS WILL BE AMCA 500D RATED PER | | | SECTION C403.2.4.3 FBC EC. THE DAMPERS MAY BE ADDED TO | | | THE LIST OF DEFERRED SUBMITTALS FOR THE PROJECT. | | | A) THE AD-7 RETURN GRILL CANNOT BE USED FOR O/A INTAKE- | | | SEE SECTION 401.5 FBC M. | | | | | | 30) OK. | | | | | | 31) DENIED M-301 THROUGH M-305: REQUIRED EXHAUST | | | VENTILATION FOR THE KITCHENS NOT SHOWN- SECTION AND | | | TABLE 403.3.2.3 FBC M. RECIRCULATING-TYPE DOMESTIC | | | KITCHEN EXHAUST HOODS ARE ALLOWED PER SECTION 505.1 | | | EXCEPTION 1 FBC M. IF THIS IS THE INTENTION PLEASE | | | PLACE A NOTE ON THE PLANS AND ADD THE HOODS TO THE | | | DEFERRED SUBMITTALS LIST. | | | | | | 32) DENIED M-301 THROUGH M-305: A) PLEASE PLACE A NOTE | | | TO INDICATE THAT DRYER EXHAUST DUCTS SHALL NOT RUN | | | THROUGH THE RETURN PLENUMS. IT APPEARS THAT THIS IS THE | | | CASE ON SHEET M3-02- UNITS A2D, A3, A4, B1 AND ON SHEET | | | M3.03- UNIT B2. B) M3-01: IT APPEARS THAT THE FLOOR | | | PLAN DRAWINGS FOR UNITS A2 AND A2.1 ARE CUT OFF. C) | | | M3-03: IT APPEARS THAT THE DRYER EXHAUST DUCT FOR UNIT | | | B2A IS RUNNING THROUGH AN ADJACENT APARTMENT. D) PLEASE | | | ADD A NOTE TO INDICATE THE TOILET AND DRYER EXHAUST | | | TERMINATIONS SHALL BE LOCATED A MINIMUM OF 3' TO | | | OPERABLE OPENINGS INTO THE BUILDING- SECTION 501.3.1 | | | (3) FBC M. | | | | | | 33) OK. | | | 34) OK. | | | 35) OK. | | | 36) OK. | | | 37) OK. | | | 38) OK. | | | | | | 39) APPROVED WITH EXCEPTION: PLEASE SUBMIT THE | | | COMMISSIONING PLAN AS A SEPARATE DOCUMENT APART FROM | | | THE COMMENT RESPONSE DOCUMENT. PLACE A NOTE ON SHEET M0 | | | INDICATING COMPLIANCE WITH SECTION C104.2.6 FINAL | | | INSPECTION: | | | THE BUILDING SHALL HAVE A FINAL INSPECTION AND SHALL | | | NOT BE OCCUPIED UNTIL APPROVED. THE FINAL INSPECTION | | | SHALL INCLUDE VERIFICATION OF THE INSTALLATION AND | | | PROPER OPERATION OF ALL REQUIRED BUILDING CONTROLS, AND | | | DOCUMENTATION VERIFYING ACTIVITIES ASSOCIATED WITH | | | REQUIRED BUILDING COMMISSIONING HAVE BEEN CONDUCTED AND | | | FINDINGS OF NONCOMPLIANCE CORRECTED. BUILDINGS, OR | | | PORTIONS THEREOF, SHALL NOT BE CONSIDERED FOR A FINAL | | | INSPECTION UNTIL THE CODE OFFICIAL HAS RECEIVED A | | | LETTER OF TRANSMITTAL FROM THE BUILDING OWNER | | | ACKNOWLEDGING THAT THE BUILDING OWNER HAS RECEIVED THE | | | PRELIMINARY COMMISSIONING REPORT AS REQUIRED IN SECTION | | | C408.2.4. | | | | | | 40) APPROVED WITH EXCEPTION: PLEASE PROVIDE A MASTER | | | LIST OF DEFERRED SUBMITTALS SHEET M0. DEFERRED | | | SUBMITTALS: REQUIRED SUBMITTALS LISTED BELOW SHALL HAVE | | | SHOP DRAWING STAMPS BY THE EOR AND EITHER BE SUBMITTED | | | TO THE BUILDING DEPARTMENT, OR BE IN THE FIELD AT TIME | | | OF INSPECTION. PLEASE INCLUDE: | | | A) FIRE DAMPERS AND FIRE/SMOKE DAMPERS. | | | B) MOTORIZED AND GRAVITY DAMPERS | | | C) DUCT SMOKE DETECTORS | | | D) LOUVERS FOR EXHAUST AND OUTSIDE AIR INTAKES | | | INCLUDING MANUFACTURER'S SPECIFICATIONS AND FL. PRODUCT | | | APPROVALS AND/OR MIAMI-DADE NOA'S | | | F) AC STAND NOA'S OR FL. PRODUCT APPROVALS | | | G) C0, N02, & CO2 SENSORS | | | H) CLOTHES DRYERS | | | I) X-VENT BATHROOM AND DRYER EXHAUST WALL CAPS | | | J) COOKING APPLIANCES | | | K) SIGNED AND SEALED SITE-SPECIFIC WIND LOAD | | | ENGINEERING FOR INSTALLATION OF ALL ROOF TOP MECHANICAL | | | EQUIPMENT. | | | L) O/A DAMPERS. | | | | | | NEW COMMENTS. | | | | | | 1) SHEET M1-01A: POSITIVE PRESSURIZATION MUST BE | | | PROVIDED AND MAINTAINED IN THE BIKE STORAGE ROOM | | | ADJACENT TO THE ENCLOSED GARAGE. PLEASE SEE SECTION 202 | | | FOR DEFINITION OF OCCUPIED SPACE AND SECTION 404.3 FBC | | | M AND PROVIDE A SYSTEM FOR THE ROOM THAT MEETS | | | COMPLIANCE | | | | | | 2) M1-04A: CLARIFY HOW THE JANITOR'S CLOSET WILL BE | | | VENTILATED AND INDICATE HOW MAKEUP AIR IS BEING | | | PROVIDED TO THE RESTROOMS AND TO THE CLOSET- SECTION | | | 107.2.1 WPB. A) PROVIDE THE SEQUENCE OF OPERATION FOR | | | THE FANS- SECTION 401.3 AND TABLE 403.3.1.1 FBC M. | | | | | | 3) M1-05A & M5-01: AHU-7 IS MISLABELED AS A SYSTEM | | | SERVING THE LOUNGE- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-13 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-11 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2020-03-13 15:22:54 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #20011267 | | | 3/12/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR ALL | | | SYSTEMS- SECTION C403.2.1 FBC EC. | | | | | | 2) SHEET M-101A & M5-01: THE O/A VENTILATION SCHEDULE | | | DOES NOT INCLUDE CALCULATIONS FOR THE GROUND FLOOR | | | LOBBY, BREAKROOM, AND MAIL ROOM BEING SUPPLIED BY AHU-3 | | | & 4. PLEASE NOTE THE CALCULATIONS SHALL BE IN | | | ACCORDANCE WITH TABLE 403.3.1.1 FBC M. | | | | | | 3) M5-01: CONCERNING THE USE OF NATURAL VENTILATION FOR | | | THE APARTMENTS, PLEASE REFER TO SECTION 401.2 FBC M. | | | NATURAL VENTILATION CAN ONLY BE USED IF THE APARTMENTS | | | ARE NOT REQUIRED TO HAVE MECHANICAL VENTILATION. | | | 401.2 VENTILATION REQUIRED. | | | "EVERY OCCUPIED SPACE SHALL BE VENTILATED BY NATURAL | | | MEANS IN ACCORDANCE WITH SECTION 402 OR BY MECHANICAL | | | MEANS IN ACCORDANCE WITH SECTION 403. WHERE THE AIR | | | INFILTRATION RATE IN A DWELLING UNIT IS LESS THAN 3 AIR | | | CHANGES PER HOUR WHEN TESTED WITH A BLOWER DOOR AT A | | | PRESSURE OF 0.2-INCH WATER COLUMN (50 PA) IN ACCORDANCE | | | WITH SECTION R402.4.1.2 OF THE FLORIDA BUILDING CODE, | | | ENERGY CONSERVATION, THE DWELLING UNIT SHALL BE | | | VENTILATED BY MECHANICAL MEANS IN ACCORDANCE WITH | | | SECTION 403." | | | FOR MORE INFORMATION REFER TO SECTIONS R402.4.1.2, AND | | | C402.5 THROUGH C402.5.8 | | | | | | 4) M-101A: AN EXHAUST INLET SHALL BE INSTALLED IN THE | | | AREA OF HEAVIEST CONCENTRATIONS OF CONTAMINANTS | | | ACCORDING TO SECTION 502.1.1 FBC M. DOES THE LOCATION | | | OF GARAGE FAN F-2 MEET THAT CRITERIA? WILL CIRCULATION | | | FANS BE INSTALLED IN THE GARAGE? | | | | | | 5) M-101A: SHOW HOW THE F-2 FAN WILL BE PROTECTED FROM | | | VEHICULAR DAMAGE- SECTION 303.4 AND 304.6 FBC M. | | | | | | 6) M-101A: SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE CO AND NO2 SENSORS. | | | PLEASE NOTE THAT THE SPECS MAY BE A DEFERRED SUBMITTAL. | | | | | | 7) M-101.A: THE L-3 MAKEUP AIR LOUVER AT THE COMMON | | | WALL BETWEEN THE PARKING GARAGE AND THE DIESEL FIRE | | | PUMP ROOM IS NOT PERMITTED. MAKEUP AIR SHALL BE TAKEN | | | FROM A CLEAN SOURCE OUTSIDE OF THE BUILDING, AND ALL | | | AIR FROM THE ENCLOSED GARAGE SHALL BE EXHAUSTED AND NOT | | | PERMITTED TO BE RECIRCULATED- TABLE 403.3.1.1, AND | | | SECTIONS 506.5 AND 401.4 FBC M. A) PLEASE NOTE THAT THE | | | WALLS AND CEILING ENCLOSING THE PUMP AND FUEL TANK ROOM | | | SHALL BE MINIMUM 1-HR. FIRE-RATED IN ACCORDANCE WITH | | | TABLE 4.13.1.1.2 NFPA 20, AND TABLE 307.1 AND SECTION | | | 414.2 FBC B. THE LIFE SAFETY PLAN- SHEET CD-01 SHOWS NO | | | FIRE-RATING FOR THE COMMON WALL SEPARATING THE ENCLOSED | | | GARAGE AND THE PUMP ROOM. PLEASE CORRECT. | | | | | | 8) M-101A: PROVIDE EXHAUST VENTILATION CALCULATIONS AND | | | THE SEQUENCE OF OPERATION FOR THE PUMP ROOM FAN F-5- | | | SEE SECTION 502.8.1.1 SEE SYSTEM REQUIREMENTS BELOW- | | | | | | 1. MECHANICAL VENTILATION SHALL BE PROVIDED AT A RATE | | | OF NOT LESS THAN 1 CFM PER SQUARE FOOT OF FLOOR AREA | | | OVER THE STORAGE AREA. | | | 2. THE SYSTEMS SHALL OPERATE CONTINUOUSLY UNLESS | | | ALTERNATE DESIGNS ARE APPROVED. | | | 3. A MANUAL SHUTOFF CONTROL SHALL BE PROVIDED OUTSIDE | | | OF THE ROOM IN A POSITION ADJACENT TO THE ACCESS DOOR | | | TO THE ROOM OR IN ANOTHER APPROVEDLOCATION. THE SWITCH | | | SHALL BE A BREAK-GLASS OR OTHER APPROVED TYPE AND SHALL | | | BE LABELED: VENTILATION SYSTEM EMERGENCY SHUTOFF. | | | 4. THE EXHAUST VENTILATION SHALL BE DESIGNED TO | | | CONSIDER THE DENSITY OF THE POTENTIAL FUMES OR VAPORS | | | RELEASED. FOR FUMES OR VAPORS THAT ARE HEAVIER THAN | | | AIR, EXHAUST SHALL BE TAKEN FROM A POINT WITHIN 12 | | | INCHES (305 MM) OF THE FLOOR. FOR FUMES OR VAPORS THAT | | | ARE LIGHTER THAN AIR, EXHAUST SHALL BE TAKEN FROM A | | | POINT WITHIN 12 INCHES (305 MM) OF THE HIGHEST POINT OF | | | THE ROOM. | | | 5. THE LOCATION OF BOTH THE EXHAUST AND INLET AIR | | | OPENINGS SHALL BE DESIGNED TO PROVIDE AIR MOVEMENT | | | ACROSS ALL PORTIONS OF THE FLOOR OR ROOM TO PREVENT THE | | | ACCUMULATION OF VAPORS. | | | 6. THE EXHAUST AIR SHALL NOT BE RECIRCULATED TO | | | OCCUPIED AREAS IF THE MATERIALS STORED ARE CAPABLE OF | | | EMITTING HAZARDOUS VAPORS AND CONTAMINANTS HAVE NOT | | | BEEN REMOVED. AIR CONTAMINATED WITH EXPLOSIVE OR | | | FLAMMABLE VAPORS, FUMES OR DUSTS; FLAMMABLE, HIGHLY | | | TOXIC OR TOXIC GASES; OR RADIOACTIVE MATERIALS SHALL | | | NOT BE RECIRCULATED. | | | | | | 9) M-101A: PROVIDE THE REQUIRED CLEARANCES ON THE PLAN | | | FOR THE F-5 EXHAUST OUTLET- SECTION 501.3.1 (2) FBC M. | | | | | | 10) M-101A & FP1-01A: PROVIDE PRODUCT SUBMITTALS FOR | | | THE DIESEL FIRE PUMP, THE PUMP EXHAUST DUCTWORK, AND | | | THE 200-GALLON DIESEL FUEL TANK- SECTIONS 4.2 AND | | | 11.5.2.5 NFPA 20, AND SECTION 22.1 NFPA 30. THE | | | SUBMITTALS SHALL INDICATE THE UL LISTINGS FOR EACH | | | PRODUCT. PLEASE NOTE THAT THE SUBMITTALS MAY BE | | | DEFERRED BY REQUEST. | | | | | | 11) M-101A & FP1-01A: PLEASE NOTE THE VENTILATION | | | SYSTEM FOR THE PUMP AS DESIGNED WILL BE CAPABLE OF | | | MAINTAINING A MAXIMUM TEMPERATURE OF 120 DEGREES F IN | | | THE ROOM, WILL PROVIDE ADEQUATE COMBUSTION AIR, AND | | | WILL REMOVE ALL HAZARDOUS VAPORS- SECTION 11.3.2.1 NFPA | | | 20. PLEASE NOTE THERE IS NO AC SYSTEM IN THE ROOM | | | | | | 12) FP1-01A: PROVIDE FILL AND VENT PIPE SPECIFICATIONS, | | | PIPE SIZING CALCULATIONS, PIPE INSTALLATION DETAILS- | | | JOINTS AND CONNECTIONS, AND PIPE SUPPORT DETAILS- | | | SECTION 1302, 1303, 1305 FBC M. B) SHOW THE REMOTE FILL | | | PIPING LOCATION AND FILL PIPING RUN- SECTION 1305.6 FBC | | | M. C) SHOW THE NORMAL AND EMERGENCY RELIEF VENT PIPING | | | RUNS AND TERMINATION LOCATIONS AT THE EXTERIOR OF THE | | | BUILDING WITH REQUIRED CLEARANCES- SECTION 1305.7 FBC | | | M. | | | | | | 13) M-101A: IT APPEARS THE F-3 INLINE FAN FOR THE TRASH | | | ROOM IS NOT LOCATED IN THE ROOM OR HAS NO EXHAUST GRILL | | | CONNECTION SHOWN- SECTION 107.2.1 WPB. | | | | | | 14) M-101A: PROVIDE AUTOMATICALLY CONTROLLED SHUTOFF | | | DAMPERS- EITHER MOTORIZED OR GRAVITY FOR THE O/A INTAKE | | | DUCTS TO AHU 3 & 4- SECTION C403.2.4.3 FBC EC. | | | | | | 15) M-101A: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | | SUPPLY AIR SYSTEMS OF THE 5-TON AHU 3 & 4 SYSTEMS PER | | | SECTION 606.2.1. PLEASE NOTE THAT AN EXEMPTION CAN BE | | | APPLIED IF THE MANUFACTURER'S SPECIFICATIONS INDICATE | | | THE SYSTEMS ARE NOT CAPABLE OF PRODUCING OVER 2000 CFMS | | | OF SUPPLY AIR. | | | | | | 16) M-101A: PROVIDE CONDENSATE DISPOSAL PLANS FOR AHU-3 | | | & 4- SECTION 307.2.1 FBC M. | | | | | | 17) M-101A & B: PLEASE VERIFY ALL FUTURE KITCHEN | | | EXHAUST TERMINATIONS WILL MEET REQUIRED CLEARANCES PER | | | SECTIONS 501.3.1, 506.3.13.2 & 506.3.13.3 FBC M, | | | INCLUDING 10' CLEARANCES FROM GRADE AND THE PROPERTY | | | LINE. | | | | | | 18) M-101A & B: PLACE A NOTE INDICATING SEPARATE | | | PERMITS ARE REQUIRED FOR THE KITCHEN HOOD EXHAUST | | | SYSTEMS, THE FIRE SUPPRESSIONS SYSTEMS, AND WALK-IN | | | COOLERS AND FREEZERS- SECTION 107.2.1 WPB. A) | | | CONCERNING THE HOOD SYSTEMS UNDER SEPARATE PERMIT | | | PLEASE BE ADVISED THAT SECTION 508.1.1 FBC M- MAKEUP | | | AIR TEMPERATURE WILL BE ENFORCED: THE TEMPERATURE | | | DIFFERENTIAL BETWEEN MAKEUP AIR AND THE AIR IN THE | | | CONDITIONED SPACE SHALL NOT EXCEED 10 DEGREESF (6?C) | | | EXCEPT WHERE THE ADDED HEATING AND COOLING LOADS OF THE | | | MAKEUP AIRDO NOT EXCEED THE CAPACITY OF THE HVAC | | | SYSTEM. | | | | | | 19) M-101B: OUTDOOR VENTILATION AIR IS REQUIRED FOR THE | | | ELEVATOR LOBBY- SECTION 404.3 AND TABLE 403.3.1.1 FBC | | | M. | | | | | | 20) M-101B: AN EXHAUST VENTILATION SYSTEM IS REQUIRED | | | FOR THE PET SPA- TABLE 403.3.1.1 FBC M. PLEASE PROVIDE | | | A SYSTEM AND FAN SIZING CALCULATIONS. IF THE SPA IS TO | | | BE UNDER SEPARATE PERMIT, PLEASE PLACE A NOTE ON THE | | | PLAN ACCORDINGLY. NOTE- THE PLAN SHOWS AN UNTAGGED AIR | | | HANDLER IN THE SPACE. A) SHEET CD-01: THE LIFE SAFETY | | | DOES NOT INDICATE THAT THE COMMON WALLS SEPARATING THE | | | PET SPA/TRANSFORMER ROOM AND PET SPA/GARAGE ARE | | | FIRE-RESISTANT RATED- TABLE 508.4 FBC B. | | | | | | 21) M-102B: THE PLAN APPEARS TO SHOW HP CONDENSERS | | | INSTALLED INSIDE THE BUILDING WHICH MAY NOT BE IN | | | ACCORDANCE WITH THE PRODUCT'S LISTING AND INSTALLATION | | | GUIDELINES- SECTION 304.1 FBC M. A) PLEASE PROVIDE | | | DETAILS TO INDICATE HOW THE CONDENSERS ARE TO BE | | | INSTALLED. WILL THEY BE ANCHORED DIRECTLY TO THE SLAB, | | | ON WALL BRACKETS, STANDS? HOW WILL THEY BE PROTECTED | | | FROM VEHICLE DAMAGE- SEE SECTIONS 303.4 AND 304.6 FBC | | | M. | | | | | | 22) M-103B: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR | | | THE GAS-FIRED POOL HEATER (MAY BE A DEFERRED | | | SUBMITTAL)- SECTION 617.1 FBC FG. THE SPECS AND | | | INSTALLATION GUIDELINES SHALL VERIFY THE USE OF THE PVC | | | COMBUSTION AIR INTAKE DUCT, AND B VENT SYSTEM. A) | | | PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE POOL | | | HEATER INCLUDING THE TOTAL BTUH INPUT RATING OF THE | | | APPLIANCE. B) PROVIDE A VENTING DIAGRAM SHOWING THE | | | SIZE OF THE VENT, RISER HEIGHT, LATERAL LENGTH, AND | | | TOTAL VENT RUN- TABLE 504.2(1) FBC FG. | | | | | | 24) M-101B: PROVIDE A LIST OF POOL TREATMENT CHEMICALS | | | AND MATERIALS THAT WILL BE STORED IN THE POOL EQUIPMENT | | | ROOM, AND THE QUANTITIES OF THE CHEMICALS AND | | | MATERIALS- SEE SECTION 414.1.3 FBC B. A) PLEASE NOTE | | | THAT SHEET CD-03 DOES NOT INDICATE FIRE-RATED WALLS FOR | | | THE ROOM. | | | | | | 25) M-101B: PROVIDE EXHAUST VENTILATION CALCULATIONS | | | FOR THE POOL EQUIPMENT ROOM AND A SEQUENCE OF OPERATION | | | FOR THE F-8 FAN. A) REFER TO SECTION 510.9 FBC M AND | | | PROVIDE THE TYPE OF EXHAUST DUCTWORK TO BE INSTALLED. | | | | | | 26) M-104A & B: THE ACCESS PANELS SPECIFIED UNDER NOTE | | | #2 SHALL BE SIZED LARGE ENOUGH TO REMOVE THE FAN COIL | | | UNITS- SECTION 306.1 FBC M. | | | | | | 27) M-105A: IT APPEARS FIRE DAMPERS ARE MISSING FOR THE | | | AHU-5 & 6 SUPPLY, RETURN, AND O/A DUCTS PENETRATING THE | | | FIRE-RATED MECHANICAL ROOM WALLS- SECTION 607.5.2 FBC | | | M. | | | | | | 28) M-105A: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | | SUPPLY AIR SYSTEMS OF THE 5-TON AHU 5, 6, & 7 SYSTEMS | | | PER SECTION 606.2.1. PLEASE NOTE THAT AN EXEMPTION CAN | | | BE APPLIED IF THE MANUFACTURER'S SPECIFICATIONS | | | INDICATE THE SYSTEMS ARE NOT CAPABLE OF PRODUCING OVER | | | 2000 CFMS OF SUPPLY AIR. | | | | | | 29) M-105A: PROVIDE AUTOMATICALLY CONTROLLED SHUTOFF | | | DAMPERS- EITHER MOTORIZED OR GRAVITY FOR THE O/A INTAKE | | | DUCTS TO AHU 5,6, & 7- SECTION C403.2.4.3 FBC EC. | | | | | | 30) M-104A, 105A, 106A, 107A, 108A: IT DOES NOT APPEAR | | | THAT THE O/A IS BEING EVENLY DISTRIBUTED TO ALL AREA OF | | | THE CORRIDORS AS DEPICTED ON THE PLANS. | | | | | | 31) M-301 THROUGH M-305: REQUIRED EXHAUST VENTILATION | | | FOR THE KITCHENS NOT SHOWN- SECTION AND TABLE 403.3.2.3 | | | FBC M. | | | | | | 32) M-301 THROUGH M-305: PLEASE PLACE NOTES ON THE PLAN | | | TO INDICATE NO COMBUSTIBLE MATERIAL IN THE RETURN | | | PLENUMS, NO FUEL-FIRED APPLIANCES IN THE RETURN | | | PLENUMS, AND THE ACCESS PANELS FOR THE FAN COIL UNITS | | | SHALL BE SIZED LARGE ENOUGH FOR SERVICE AND REPLACEMENT | | | OF THE UNITS- SECTIONS 606.1, 606.2, AND 306.1 FBC M. | | | | | | 33) M-302- 303: SUBMIT MANUFACTURER'S SPECIFICATIONS | | | FOR ALL CLOTHES DRYERS SHOWN ON THE PLANS, AND INDICATE | | | THE TYPE AND SIZE OF DUCTS, AND TOTAL LENGTH OF THE | | | DUCT RUN ON THE PLANS- SECTION 504.1 AND 504.8.4 FBC M. | | | | | | 34) M-302, UNIT A3: THE MAIN RETURN THROUGH THE | | | LOUVERED DOOR SHALL BE MINIMUM 10' FROM THE COOKING | | | APPLIANCE- SECTION 601.5 FBC M. A) PLEASE NOTE THE | | | LOUVERED DOOR SHALL BE NON-COMBUSTIBLE IN ACCORDANCE | | | WITH SECTION 602.1 FBC M. | | | | | | 35) M-302, UNIT A4: SHOW THE SUPPLY CFMS AT AD-2 | | | DIFFUSER. | | | | | | 36) M-302 & M-501, UNIT B1: FCU-3 HAS A MAXIMUM CFM | | | CAPACITY OF 430 CFMS, HOWEVER THE LAYOUT PLAN INDICATES | | | 580 CFMS REQUIRED. | | | | | | 37) M-303, UNIT B2C: SHOW THE SUPPLY CFMS AT AD-3 | | | DIFFUSER. | | | | | | 38) M-401: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | | SUPPLY AIR SYSTEMS OF DOAS-1 & 2 PER SECTION 606.2.1 | | | FBC M. | | | | | | 39) COMMISSIONING PLAN: COMMISSIONING OF THE MECHANICAL | | | SYSTEMS AND SERVICE WATER HEATING SYSTEMS IS REQUIRED | | | PER SECTION C408.2 FBC EC. COMMISSIONING PLAN. "PRIOR | | | TO THE FINAL MECHANICAL AND PLUMBING INSPECTIONS, THE | | | LICENSED DESIGN PROFESSIONAL, ELECTRICAL ENGINEER, | | | MECHANICAL ENGINEER, OR APPROVED AGENCY SHALL PROVIDE | | | EVIDENCE OF MECHANICAL SYSTEMS COMMISSIONING AND | | | COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF THIS | | | SECTION". | | | A COMMISSIONING PLAN SHALL BE DEVELOPED BY A LICENSED | | | DESIGN PROFESSIONAL, ELECTRICAL ENGINEER, MECHANICAL | | | ENGINEER OR APPROVED AGENCY AND SHALL INCLUDE THE | | | FOLLOWING ITEMS: | | | 1. A NARRATIVE DESCRIPTION OF THE ACTIVITIES THAT WILL | | | BE ACCOMPLISHED DURING EACH PHASE OF COMMISSIONING, | | | INCLUDING THE PERSONNEL INTENDED TO ACCOMPLISH EACH OF | | | THE ACTIVITIES. | | | 2. A LISTING OF THE SPECIFIC EQUIPMENT, APPLIANCES OR | | | SYSTEMS TO BE TESTED AND A DESCRIPTION OF THE TESTS TO | | | BE PERFORMED. | | | 3. FUNCTIONS TO BE TESTED INCLUDING, BUT NOT LIMITED | | | TO, CALIBRATIONS AND ECONOMIZER CONTROLS. | | | 4. CONDITIONS UNDER WHICH THE TEST WILL BE PERFORMED. | | | TESTING SHALL AFFIRM WINTER AND SUMMER DESIGN | | | CONDITIONS AND FULL OUTSIDE AIR CONDITIONS. | | | 5. MEASURABLE CRITERIA FOR PERFORMANCE' | | | | | | 40) DEFERRED SUBMITTALS: REQUIRED SUBMITTALS LISTED | | | BELOW SHALL HAVE SHOP DRAWING STAMPS BY THE EOR AND | | | EITHER BE SUBMITTED TO THE BUILDING DEPARTMENT, OR BE | | | IN THE FIELD AT TIME OF INSPECTION. | | | A) FIRE DAMPERS AND FIRE/SMOKE DAMPERS. | | | B) MOTORIZED AND GRAVITY DAMPERS | | | C) DUCT SMOKE DETECTORS | | | D) LOUVERS FOR EXHAUST AND OUTSIDE AIR INTAKES | | | INCLUDING MANUFACTURER'S SPECIFICATIONS AND FL. PRODUCT | | | APPROVALS AND/OR MIAMI-DADE NOA'SEF) AC STAND NOA'S OR | | | FL. PRODUCT APPROVALS | | | E) C0, N02, & CO2 SENSORS | | | F) CLOTHES DRYERS | | | G) TOILET AND DRYER EXHAUST WALL CAPS | | | H) COOKING APPLIANCES | | | I) SIGNED AND SEALED SITE-SPECIFIC WIND LOAD | | | ENGINEERING FOR INSTALLATION OF ALL ROOF TOP MECHANICAL | | | EQUIPMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2020-08-04 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-08-04 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-08-04 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2020-08-04 11:51:20 | PASSED WITH PROVISOS. | | | PROVISOS | | | | | | 1) THE SAMPLING PORT FOR ALL GREASE INTERCEPTORS IS TO | | | BE LOCATED ON THE DISCHARGE SIDE OF THE UNIT PER THE | | | CITY OF WPB REQUIREMENTS. | | | 2) THE BOTTOM OF THE RACKED TANKLESS WATER HEATER UNITS | | | ON THE ROOF SHALL ALSO MEET THE CLEARANCES REQUIRED IN | | | FBC-BUILDING SEC.1510.10 AND TABLE 1510.10. | | | 3) SUBMIT A CONDENSATE RISER FOR REVIEW. THE SIZING | | | SHALL COMPLY WITH FBC-PLUMBING SEC.314.2.2 & TABLE | | | 314.2.2. 2ND REQUEST. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2020-07-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-07-21 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-07-21 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2020-07-21 11:43:53 | PASSED WITH PROVISOS. | | | PROVISOS | | | | | | 1) THE SAMPLING PORT FOR ALL GREASE INTERCEPTORS IS TO | | | BE LOCATED ON THE DISCHARGE SIDE OF THE UNIT PER THE | | | CITY OF WPB REQUIREMENTS. | | | 2) THE BOTTOM OF THE RACKED TANKLESS WATER HEATER UNITS | | | ON THE ROOF SHALL ALSO MEET THE CLEARANCES REQUIRED IN | | | FBC-BUILDING SEC.1510.10 AND TABLE 1510.10. | | | 3) SUBMIT AN EXPANDED DETAIL AS TO HOW THE HOT WATER | | | RETURN LINE IS CONNECTED BACK TO THE WATER SYSTEM. WPB | | | AMEND. TO FBC SEC. 107 2.1. | | | 4) SHTS. P6-01, P6-02, P6-04 - PLACE A NOTE ON THESE | | | PLANS THAT READS "SEE PLAN VIEW DRAWINGS FOR THE | | | SPECIFIC LEVELS FOR KEYNOTE LEGEND FOR THE RISERS." | | | 5) SUBMIT A CONDENSATE RISER FOR REVIEW. THE SIZING | | | SHALL COMPLY WITH FBC-PLUMBING SEC.314.2.2 & TABLE | | | 314.2.2. 2ND REQUEST. | | | 6) RIGID SUPPORT SWAY BRACING SHALL BE PROVIDED AT | | | CHANGES IN DIRECTION GREATER THAN 45 DEGREES FOR PIPE | | | SIZES 4 INCHES AND LARGER IN THE SANITARY SYSTEM PER | | | 2017 FBC-PLUMBING SEC.308.6. PROVIDE A DETAIL FOR THESE | | | SUPPORTS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-07-20 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-07-14 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2020-07-17 14:06:54 | | | | | | | 1) THE SAMPLING PORT FOR ALL GREASE INTERCEPTORS IS TO | | | BE LOCATED ON THE DISCHARGE SIDE OF THE UNIT PER THE | | | CITY OF WPB REQUIREMENTS. | | | 2) THE BOTTOM OF THE RACKED TANKLESS WATER HEATER UNITS | | | ON THE ROOF SHALL ALSO MEET THE CLEARANCES REQUIRED IN | | | FBC-BUILDING SEC.1510.10 AND TABLE 1510.10. | | | 3) SUBMIT AN EXPANDED DETAIL AS TO HOW THE HOT WATER | | | RETURN LINE IS CONNECTED BACK TO THE WATER SYSTEM. WPB | | | AMEND. TO FBC SEC. 107 2.1. | | | 4) SHTS. P6-01, P6-02, P6-04 - PLACE A NOTE ON THESE | | | PLANS THAT READS "SEE PLAN VIEW DRAWINGS FOR THE | | | SPECIFIC LEVELS FOR KEYNOTE LEGEND FOR THE RISERS." | | | 5) SUBMIT A CONDENSATE RISER FOR REVIEW. THE SIZING | | | SHALL COMPLY WITH FBC-PLUMBING SEC.314.2.2 & TABLE | | | 314.2.2. 2ND REQUEST. | | | 6) RIGID SUPPORT SWAY BRACING SHALL BE PROVIDED AT | | | CHANGES IN DIRECTION GREATER THAN 45 DEGREES FOR PIPE | | | SIZES 4 INCHES AND LARGER IN THE SANITARY SYSTEM PER | | | 2017 FBC-PLUMBING SEC.308.6. PROVIDE A DETAIL FOR THESE | | | SUPPORTS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-06-12 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-05-19 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2020-06-04 10:54:06 | 1) SUBMIT A SET OF SIGNED AND SEALED CIVIL DRAWINGS FOR | | | REVIEW. THE CIVIL DRAWINGS SHALL SHOW THE GAS, SANITARY | | | AND STORM SYSTEMS ON THE PLANS. WPB AMEND. TO FBC | | | SEC.107.2..1. | | | THE FOLLOWING COMMENTS #2 THROUGH #6 ALL REFER TO SHT. | | | CD-21: | | | 2) THE DETAILS FOR THE REINFORCEMENT FOR THE GRAB BARS | | | SHOW THE BOTTOM OF THE REINFORCEMENT AT 30 INCHES | | | MAXIMUM BUT THE FAIR HOUSING GUIDELINES SHOW 32 INCHES | | | MAX. CLARIFY.REVISE ALL DETAILS AS NEEDED. | | | 3) DETAIL #3 - SHOW THE LENGTH OF THE REINFORCEMENT FOR | | | THE GRAB BAR. A MINIMUM OF 24 INCHES IS REQUIRED PER | | | THE FHA GUIDELINES. | | | 4) DETAIL #5 - SHOW THE MAXIMUM HEIGHT DIMENSION FOR | | | THE REINFORCEMENT FOR THE GRAB BAR.COMPLY WITH THE FAIR | | | HOUSING ACT GUIDELINES. | | | 5) DETAIL #14 - SHOW THE REQUIRED CLEAR FLOOR SPACE FOR | | | THE PERPENDICULAR APPROACHTO THE TUB. COMPLY WITH FHA | | | GUIDELINES. | | | 6) DETAIL #16 - THERE IS A NOTE BY THE SHOWER DIAGRAM | | | THAT REFERS TO A 23 INCH BY 60 INCH ROLL IN SHOWER. | | | CLARIFY.SHOWERS SHALL BE A MINIMUM OF 30 INCHES IN | | | WIDTH.FBC-PLUMBING SEC.417.4. | | | 7) SHT. CD-22 - THE PLAN IS LABELED AS "COMMON AND | | | PUBLIC AREAS" BUT THE PLAN REFLECTS WHAT APPEARS TO BE | | | THE INTERIOR OF THE UNITS. CLARIFY. | | | 8) SHT. CD-23 - DETAIL #14 - THE END OF THE "L" SHAPED | | | SEAT SHALL BE 23 INCHES MAXIMUM FROM THE SEAT WALL PER | | | ANSI A117.1 - 1986.. THE DETAIL SHOWS 23-24 INCHES. | | | CLARIFY. | | | 9) SHT. CD-23 - DETAIL #11 - THE DETAIL SHOWS WHAT | | | APPEARS TO BE TWO DIFFERENT HEIGHT DIMENSIONS FOR THE | | | BREAK ROOM SINK. ONE SHOWS 36 INCHES AND ONE SHOWS 34 | | | INCHES. THE MAXIMUM HEIGHT IS 34 INCHES. CLARIFY. | | | 10) SHT. CD-23 - DETAIL #15 - THE MAXIMUM HEIGHT TO THE | | | BOTTOM OF A URINAL SCREEN IS 12 INCHES . THE DETAIL | | | SHOWS 13 1/2 INCHES.FBC-PLUMBING SEC.405.3.5. | | | 11)SHT. CD-23 - DETAIL #16 - SHOWS A VERTICAL GRAB | | | BAR.GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION PER ANSI A117.1 SEC. 4.16. THERE IS NO | | | EXCEPTION FOR VERTICAL GRAB BARS. | | | 12) SHT. A3-01 - DETAIL #1 - SHOW THE REQUIRED 30 | | | INCHES BY 48 INCHES MANEUVERING SPACE LOCATED OUSIDE | | | THE SWING OF THE DOOR PER FHA GUIDELINES. | | | 13) SHT. A3-02 - DEATIL #1- SHOW THE REQUIRED 30 INCHES | | | BY 48 INCHES MANEUVERING SPACE LOCATED OUSIDE THE SWING | | | OF THE DOOR PER FHA GUIDELINES. | | | 14) SHT. A3-08 - DETAIL #1 - SHOW THE LENGTH OF THE | | | SHOWER WALL NEXT TO THE WATER CLOSET. THIS WALL CANNOT | | | EXCEED 24 INCHES PER FHA GUIDELINES. | | | 15) SHT.A3-09 - DETAIL #1 - SHOW THE LENGTH OF THE | | | SHOWER WALL NEXT TO THE WATER CLOSET. THIS WALL CANNOT | | | EXCEED 24 INCHES PER FHA GUIDELINES. | | | 16) SUBMIT DETAILS ON THE "MOVEABLE ISLAND" IN THE | | | KITCHEN. WPB AMEND. TO FBC SEC. 107.2.1. | | | 17) SHT. A3-24 - SHOW THE REQUIRED 30 INCHES BY 48 | | | INCHES MANEUVERING SPACE LOCATED OUSIDE THE SWING OF | | | THE DOOR PER FHA GUIDELINES. | | | 18) SHT. A3-24 - KEYED NOTE #13.08 NOTES THE WATER | | | HEATER IS LOCATED IN THE CABINET ABOVE THE | | | REFRIGERATOR. PROVIDE SPECIFICATIONS FOR THE WATER | | | HEATER AND REQUIREMENTS FOR THE CLEARANCES FOR | | | MAINTENANCE AND REPLACEMENT PER FBC-PLUMBING SEC. | | | 502.5. | | | 19) PLACE A NOTE ON THE PLANS THAT THE SHUTOFF VALVES | | | FOR THE WASHING MACHINES WILL BE PROVIDED WITH ACCESS | | | PER FBC-PLUMBING SEC.606.3.SEE SHT. A6-60. | | | 20) CLEARLY SHOW ON THE UNIT PLANS THAT THE PARALLEL | | | CLEAR FLOOR SPACE AT THE LAVATORIES IS CENTERED ON THE | | | LAVATORIES. | | | 21) SUBMIT DETAILS ON THE STORM DETENTION SYSTEM AS | | | REFERENCED ON SHT. A5-03. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 22) SHT. A7-30 - PROVIDE THE DIMENSIONS OF THE SUMP | | | PIT. | | | 23) SHT.ID-0.00 - DETAIL #8 - CODE ANALYSIS LISTS THE | | | TEXAS ACCESSIBILITY STANDARS. CLARIFY. | | | 24) SHT. ID-0.01 - ACCESSIBLE AND USABLE PUBLIC AND | | | COMMON AREAS SHALL COMPLY WITH ANSI A117.1 -1986 PER | | | THE FHA GUIDELINES. | | | 25) SHT. ID-0.01 - DETAIL #6 - HANDICAP TOILET AND | | | BLOCKING DETAIL SHOWS A VERTICAL GRAB BAR WITH A NOTE | | | STATING "VERTICAL GRAB BARS REQUIRED IN PUBLIC SPACES | | | ONLY BY ANSI 604." THERE IS NO SUCH CODE SECTION IN | | | ANSI A117.1 - 1986 AND THERE IS NO EXCEPTION FOR THE | | | INSTALLATION OF GRAB BARS IN A VERTICAL POSITION IN THE | | | FBC-ACCESS. REMOVE THIS NOTE FROM THE PLAN. | | | 26) SHT. ID-0.001 - THE MAXIMUM HEIGHT TO THE BOTTOM OF | | | THE BLOCKING FROM THE FINISH FLOOR IS 32 INCHES PER THE | | | FAIR HOUSING GUIDELINES, NOT 30 INCHES AS SHOWN. | | | 27) SHT. ID-0.01 - THE PLANS REFERENCE THE ADA. THE ADA | | | IS NOT ENFORCED IN FLORIDA. THE FLORIDA BUILDING CODE- | | | ACCESSIBILITY VOLUME IS THE GOVENING DOCUMENT. PLEASE | | | REVISE THE NOTE. | | | 28) SHT. ID-0.01 - DETAIL #6 - SINGLE USER COMPARTMENT | | | SHALL HAVE 59 INCHES DEEP MINIMUM WITH A FLOOR MOUNTED | | | WATER CLOSET BUT THE PLANS SHOW 56 INCHES. CLARIFY. | | | 29) SHT. ID-2.01 - DETAIL #3 - SUBMIT A DIMENSION PLAN | | | SHOWING THE LENGTH AND WIDTH OF THE TOILET ROOM.ALSO, | | | THE DOOR SWINGS INTO THE CLEAR FLOOR SPACE FOR THE | | | LAVATORY.SHOW THE SUUFICIENT MANEUVERING SPACE WITHIN | | | THE BATHROOM FOR A PERSON USING A WHEELCHAIR TO ENTER | | | AND CLOSE THE DOOR, USE THE FIXTURES, REOPEN THE DOOR, | | | AND EXIT. REFER TO FIGURE 3 OF ANSI A117.1 - 1986, | | | 30) SUBMIT THE TOTAL OCCUPANT LOAD FOR THE FITNESS | | | CENTER, LOUNGE, POOL AND CLUBROOM. THE REQUIRED NUMBER | | | OF SANNITARY FACILITIES IN THE MEN'S AND WOMEN'S | | | RESTROOM SHALL COMPLY WITH FBC-PLUMBING TABLE 403.1 AND | | | ALSO SEC.403.1.3. FOR POTTY PARITY. | | | 31) SHT. ID - 3.02 - DETAIL #15 - REMOVE THE VERTICAL | | | GRAB BAR. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION PER ANSI A117.1 - 1986 SEC. 4.16. THERE IS NO | | | EXCEPTION FOR VERTICAL GRAB BARS. | | | 32) SHT. P1-00A - PLACE RISER TAGS ON EACH RISER OF THE | | | SANITARY SYSTEM AND PROVIDE MATCH LINES ON THE PLAN | | | SHEETS. WPB AMEND. TO FBC SEC. 107.2.1. | | | 33) SHT.P1- 00B - PROVIDE MATCH LINES ON THE PLANS FOR | | | THE CONTINUATION OF DRAIN LINES AND PLACE RISER TAGS ON | | | EACH RISER. WPB AMEND. TO FBC SEC. 107.2.1. | | | 34) A SAMPLING PORT IS REQUIRED ON THE OUTLET OF EACH | | | INTERCEPTOR PER THE CITY OF WEST PALM BEACH STANDARD | | | DRAWING GS-7.1. | | | 35) THE GREASE RETENTION CAPACITY OF THE INTERCEPTOR | | | SHALL BE A MINIMUM OF 500 LBS. PER 2017 FBC-PLUMBING | | | SEC.1003.3.4.1, FOOTNOTE (A). | | | 36) SUBMIT MANUFACTURER'S DETAILS FOR THE GREASE | | | INTERCEPTORS.WPB AMEND. TO FBC SEC. 107.2.1. | | | 37) SHT. P1-02A - KEYNOTES #5 & #6 AT COLS. "C" & "E" | | | POINT TO NOTHING.CLARIFY. ALSO, PROVIDE MATCH LINES ON | | | THE PLANS. | | | 38) SHT. P1-03A.1 - TAG ALL RISERS, PROVIDE MATCH LINES | | | ON THE PLANS. KEYNOTE #6 INDICATES AN 1 1/2 INCH COLD | | | WATER LINE BUT THE PLAN SHOWS 1 1/4 INCH WATER LINE. | | | CLARIFY. | | | 39) SHT. P1-03A.2 - TAG ALL RISERS, PROVIDE MATCH LINES | | | ON THE PLANS. KEYNOTE #6 INDICATES AN 1 1/2 INCH COLD | | | WATER LINE BUT THE PLAN SHOWS 1 1/4 INCH WATER LINE. | | | CLARIFY. | | | 40) SHT. P1-03B.1 - TAG ALL RISERS, PROVIDE MATCH LINES | | | ON THE PLANS. KEYNOTE #6 INDICATES AN 1 1/2 INCH COLD | | | WATER LINE BUT THE PLAN SHOWS 1 1/4 INCH WATER LINE. | | | CLARIFY. | | | 41) SHT. P1-03B.2 - TAG ALL RISERS, PROVIDE MATCH LINES | | | ON THE PLANS. KEYNOTE #6 INDICATES AN 1 1/2 INCH COLD | | | WATER LINE BUT THE PLAN SHOWS 1 1/4 INCH WATER LINE. | | | CLARIFY. | | | 42) PROVIDE MATCH LNES AND RISER TAGS FOR THE FOLLOWING | | | PLAN SHEETS: P1-04A.1, P1-04A.2, P1-04B.1, P1-04B.2, | | | P1-05A, P1-05A.1, P1-05B, P1-06A, P1-06B, P1-07A, | | | P1-07B, P1-08A, P1-08B, P1-09A, P1-09B. | | | 43) SUBMIT AN ELEVATION DETAIL OF THE RACKED TANKLESS | | | WATER HEATERS. SHOW THE DISTANCE FROM THE BOTTOM OF THE | | | TANKLESS WATER HEATERS TO THE FINISH ROOF SURFACE. | | | CLEARANCES SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS AND 2017 FBC-FUEL GAS CODE. | | | 44) SHT. P6-01 - FULL OPEN SHUTOFF VALVES ARE REQUIRED | | | AT THE BASE OF EACH WATER RISER PER 2017 FBC-PLUMBING | | | SEC.606.1. ACCESS SHALL BE PROVIDED FOR THE VALVES. | | | 45) SHT.P3-18 - DRAINAGE RISER - DRAIN LINES ARE | | | MISSING, VENTS GOING NOWHERE, WHERE DOES THE DRAIN FOR | | | THE BATHTUB CONNECT? CLARIFY. | | | 46) SHT.P3-20 - DRAINAGE RISER - A WATER CLOSET IS | | | MISSING FROM THE DRAINAGE RISER. CLARIFY. | | | 47) SHT. P4-01 - ISLAND SINK DETAIL - ACCESS IS | | | REQUIRED THE CLEANOUT. FBC-PLUMBING SEC. 708.1.10. | | | 48) SHT. P4-01 - THE THERMO MIXING VALVE DETAIL SHALL | | | COMPLY WITH 2017 FBC-PLUMBING SEC.607.2.2. THE HOT | | | WATER OR TEMPERED WATER RETURN LINE SHALL BE ROUTED TO | | | THE COLD WATER INLET PIPE OF THE WATER HEATER AND THE | | | COLD WATER INLET PIPE OR THE HOT WATER RETURN | | | CONNECTION OF THE THERMOSTATIC MIXING VALVE. | | | 49) SHT. P4-02 - INSTANTANEOUS WATER HEATER DETAIL - | | | 3-WAY VALVES ARE NOT APPROVED PER THE 2017 FBC-PLUMBING | | | SEC.606.2. | | | 50) SHT. P4-02 - SUBMIT MANUFACTURER'S SPECIFICATIONS | | | FOR THE OIL SMART PUMP SYSTEM. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 51) SHT. P5-01 - PLUMBING FIXTURE SCHEDULE - THE | | | WASHING MACINE WASTE STACK SHALL BE A MINIMUM OF 3 INCH | | | PER 2017 FBC-PLUMBING SEC.406.2. | | | 52) SHT. P5-01 - DOMESTIC PUMP DETAIL - A LOW-PRESSURE | | | CUTOFF IS REQUIRED ON THE PUMP PER 2017 FBC-PLUMBING | | | SEC.606.5.5. | | | 53) SHT. P6-01 - THE 3/4 INCH LINE FOR THE HOSE BIBB IN | | | THE TRASH ROOM SHALL BE EQUIPPED WITH A SHUTOFF VALVE | | | PER 2017 FBC-PLUMBING SEC.606.2. | | | 54) SHT. P6-01 - SHOW THE TERMINATION POINTS OF ALL THE | | | WATER SUPPLY LINES/ TAG ALL WATER RISERS FOR | | | IDENTIFICATION AND SIZE ALL BRANCHES ON THE WATER | | | RISER. WPB AMEND. TO FBC SEC. 107.2.1. | | | 55) SHT.P6-01 - SUBMIT MANUFACTURER'S SPECIFICATIONS | | | FOR THE BOOSTER & RECIRCULATION PUMP.THE RECIRCULATION | | | PUMP SHALL COMPLY WITH THE REQUIREMENTS OF FBC-PLUMBING | | | SEC.607..2.1.2. | | | 56) SHT. P6-02 - TAG ALL THE RISERS ON THE SANITARY | | | RISER FOR IDENTIFICATION AND IDENTIFY THE FIXTURES. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 57) SHT.P6-04 - THE PUBLISHED ROOF DRAIN FLOW RATE, | | | BASED ON THE HEAD OF WATER ABOVE THE ROOF DRAIN, SHALL | | | BE USED TO SIZE THE STORM DRAINAGE SYSTEM IN ACCORDANCE | | | WITH FBC-PLUMBING SECTION 1106, 1106.1, 1106.2.. SUBMIT | | | GPM FLOW RATE CALCULATIONS FOR THE STORM DRAIANGE | | | SYSTEM. CALCULATIONS SHALL INCLUDE PARAPET WALLS PER | | | FBC-PLUMBING SEC.1106.4. | | | 58) SHT. P6-04 - THERE ARE DRAINS SHOWN AS "FLOATING", | | | AND NOT CONNECTED TO ANY PIPING. CLARIFY. | | | 59) SHT. P6-04 - CLEANOUTS ARE REQUIRED IN THE STORM | | | DRAINAGE SYSTEM OER FBC-PLUMBING SEC.1101.8. | | | 60) SHT. P6-04 - SHOW THE TERMINATION POINT OF THE | | | STORM DRAIN SYSTEM ON THE STORM SYSTEM RISER. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 61) SUBMIT A CONDENSATE RISER. THE SIZING SHALL COMPLY | | | WITH FBC-PLUMBING SEC.314.2.2 & TABLE 314.2.2. | | | 62) SHT. P1-01A STILLS HAS A NOTE REGARDING THE | | | INSTALLATION OF AN AAV TO BE INSTALLED HIGH IN ROOM ON | | | LEVEL 1. THE INSTALLATION OF AIR ADMITTANCE VALVES ARE | | | NOT PERMITTED BELOW THE TOP FOUR BRANCH INTERVALS PER | | | FBC-PLUMBING SEC.918.3.1. | | | 63) SIZE THE WATER RISERS ON THE ENLARGED UNIT PLANS. | | | WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-03-09 |
Time |
05:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-02-24 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2020-03-09 05:56:41 | PLUMBING 1ST REVIEW**DENIED**20011267 | | | | | | 1) SHT. CS-00 UNDER APPLICABLE CODE PLEASE SHOW FAIR | | | HOUSING (FHA) AS THIS PROJECT FALLS UNDER THE FAIR | | | HOUSING ACT. | | | 2) PLEASE CALL OUT WHICH FAIR HOUSING (FHA) DESIGN SPEC | | | (A OR B) THIS PROJECT WILL HAVE. IF A MIXTURE OF BOTH | | | PLEASE PROVIDE A SHEET LABELING EACH UNIT ON EACH FLOOR | | | DESIGN SPEC WILL BE. FBC 107.2.1 | | | 3) SHT A1-01 AND A1-01A ONLY SHOWS 1 TOILET ROOM. | | | PROVIDE OCCUPANCY AND OCCUPANT LOAD FOR ALL AREAS AND | | | ALL FLOORS AND PROVIDE TOILET ROOMS AS REQUIRED AS IT | | | DOES NOT APPEAR 1 IS ENOUGH. FBC-PLB 403.1 | | | 4) SHT A1-01 AND SHT A1-01A PLEASE SHOW THE REQUIRED | | | 30? X 48? CLEAR FLOOR SPACE OUTSIDE THE ACH OF THE DOOR | | | WHEN THE DOOR SWING INTO 1 OF THE REQUIRED CLEAR FLOOR | | | SPACES. FBC-ACC 603.2.1 | | | 5) PLEASE MIN THE TEXT WRITING IN EACH ROOM AS ITS TOO | | | LARGE AND MAKES IT TOO DIFFICULT TO SEE EACH ROOMS | | | LAYOUT. FBC 107.2.1 | | | 6) SHT A1-04 THE COMMON AREA TOILET AREA IT APPEARS THE | | | MEN?S HAS MORE TOILET FIXTURES THEN THE WOMEN?S AND | | | DOES NOT MEET POTTY PARITY. FBC-PLB 403.1.3 | | | 7) IN YOUR BATHROOM ELEVATION OF THE TOILET (SEE SHT | | | A3-02, A3-03,A3-16) YOU ARE SHOWING 19? AND MORE FOR | | | THE CENTER OF THE TOILET. PER FHA THE ABSOLUTE | | | MEASUREMENT MUST BE 18? FROM THE GRAB BAR SIDE OR AT | | | LEAST 1 SIDE WERE A DROP DOWN GRAB BAR IS TO BE USED. | | | 8) SHT. A3-23 DETAIL # 6, A3-29 DETAIL#5 SINK HEIGHT | | | SHOWN AS 2? 10 ??. MAX PERMITTED UNDER FHA IS 2?10?. | | | 9) SHT A6-60 PLEASE ADD NOTE THAT SHUT OFF VALVES FROM | | | WASHER/DRYERS SHALL BE ACCESSIBLE. FBC-PLB 605.6, 606.3 | | | 10) SHT I.D-0.01 DETAIL #6 YOU SHOW THE TOILET CLEAR | | | FLOOR SPACE AS 60? X 56?. THIS WOULD ONLY BE IF THE | | | TOILET WAS A WALL MOUNT. SEE FBC-ACC 604.8.1.1 AND | | | CLARIFY THAT THIS PROJECT IS WALL HUNG TOILETS ONLY IN | | | THE ADA TOILET ROOM. FBC 107.2.1 | | | 11) SHT. P1.01A TOILET ROOM PLEASE LIST ASSE 1070 | | | TEMPERING DEVICE WITH INSTANT WATER HEATER. TEMP | | | FACTORY PRE-SET @ 105 DOES NOT MEET THE FOLLOWING CODE. | | | FBC-PLB 607.1.2 | | | 12) SHT. P1.01A CALLS OUT AAV TO BE INSTALL HIGH IN | | | ROOM. AAV ARE NOT PERMITTED BELOW THE TOP 4 BRANCH | | | INTERVALS. FBC-PLB 918.3.1 AND AAV INSTALLATION MANUAL | | | 13) ON SHT P4-01 YOU SHOW A TEMPERING VALVE ON ALL | | | SINK. IS IT YOUR INTENT ON THESE BEING INSTALLED ON ALL | | | UNIT BATHROOM AND KITCHEN SINKS? PLEASE CLARIFY. FBC | | | 107.2.1 | | | 14) SHT P4-01 ISLAND SINK DETAIL FOR THE AAV PLEASE ADD | | | NOTE THIS IS NOT PERMITTED BELOW THE TOP 4 BRANCH | | | INTERVALS. FBC-PLB 918.3.1 | | | 15) SHT P-02 PLEASE LIST BACKFLOW SHALL BE LEAD FREE. | | | 2017 WPB CROSS CONNECTION MANUAL | | | 16) ON SHT. P5-01 THE INSULATION SCHEDULE LIST | | | INSULATION AS 1?. FBC-ENERGY C404.4 CALLS FOR | | | INSULATION THICKNESS BASED ON TABLE FBC-ENERGY | | | C403.2.10 AND BASED ON PIPE SIZE. PLEASE CORRECT. | | | 17) PROVIDE A COMPLETE SANITARY, WATER, AND STORM | | | ISOMETRIC DRAWING. FBC 107.3.5 | | | 18) PROVIDE INFORMATION ON THE GREASE INTERCEPTORS. | | | MANUFACTURE, SIZE, HOW YOU SIZED ETC. FBC 107.2.1. | | | UNABLE TO LOCATE ANY CIVIL PLANS. | | | | | | | | | | | | TIM HUNT | | | PLUMBING PLAN REVIEW | | | CITY OF WEST PALM BEACH (CGA SOLUTIONS) | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2020-08-10 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2020-08-10 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2020-08-10 15:29:14 | PLANNNING AND BUILDING CONSULTANTS, LLC IS PROVIDING | | | PRIVATE PROVIDER INSPECTIONS FOR THIS PROJECT. STEVEN | | | KENNEDY |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-03-09 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-03-09 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2020-03-09 07:50:12 | ROOFING SUBMITTALS HAVE BEEN DEFERRED. PLANS SPECIFY 60 | | | MIL TPO FULLY ADHERED TO LIGHT WEIGHT INSULATING | | | CONCRETE. SEE SPEC. SECTION 035216. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-31 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-31 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-20 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-20 |
Time |
17:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-05-15 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-05-15 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2020-05-15 11:51:23 | ID AND S SHEETS ARE SHOWING INVALID SIGNATURE. PER THE | | | WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN IS | | | REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1; FS | | | 471/481 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-05-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-03 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-01-30 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2020-03-03 15:52:35 | FIRST CYCLE REVIEW OF SIGNATURES-APPROVED | | | EACH CYCLE WILL NEED TO BE REVIEWED. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-07-14 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-07-14 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2020-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-05-11 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-05-11 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2020-05-11 13:16:48 | THRESHOLD DOCUMENTS ARE NOT COMPLETE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-07-02 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-07-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-06-30 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2020-07-02 15:49:17 | PROVISOS: | | | 1. PLEASE CONTINUE CMU KNEE WALL OR USE ALTERNATIVE | | | PANEL ALONG THE NORTH SIDE OF LEVEL 2 AND 3 OF THE | | | PARKING GARAGE ON OLIVE AVENUE TO SCREEN VEHICLE | | | LIGHTS. | | | 2. THE INTERIOR OF THE PARKING GARAGE ENTRANCES AND THE | | | INTERIOR OF ALL LEVELS OF THE PARKING GARAGE SHALL BE | | | TREATED (WALL AND CEILINGS) TO A DEPTH OF 20 FEET. THIS | | | INCLUDES PAINTING OR SCREENING PIPES AND OTHER | | | UTILITIES. | | | 3. ALL PARKING GARAGE LIGHTING SHALL BE SHIELDED AND | | | NOT PRODUCE GLARE TO THE OUTSIDE OF THE STRUCTURE. | | | 4. THE OWNER SHALL WORK WITH CITY STAFF TO KEEP | | | TANGLEWOOD COURT, TRINITY PLACE AND OLIVE AVENUE OPEN | | | FOR VEHICLES AND PEDESTRIANS BY MEANS OF SCAFFOLDING OR | | | OTHER MEASURES TO THE MOST EXTENT POSSIBLE THROUGHOUT | | | THE CONSTRUCTION PROCESS. | | | 5. THE BENCH SHALL HAVE A MIDDLE BAR AND | | | ANTI-SKATEBOARDING BARS/OBJECTS TO DETER LOITERING. | | | 6. THE OWNER SHALL COORDINATE WITH THE CITY PARKING | | | ADMINISTRATION FOR THE REMOVAL AND RELOCATION OF | | | ON-STREET PARKING SPACES. | | | 7. ENHANCED LANDSCAPE (E.G. SEAGRAPES) SHALL BE | | | INCLUDED ALONG THE WESTERN FA?ADE TO PROVIDE SUFFICIENT | | | GARAGE SCREENING (REVIEWED THROUGH LANDSCAPE PERMIT). | | | 8. IF THE BICYCLE RACKS CANNOT BE DIRECTLY MOUNTED TO | | | PAVERS AND WOULD REQUIRE A CONCRETE PAD, THE LOCATION | | | SHALL BE MODIFIED TO EXISTING CONCRETE AREA. | | | 9. STAFF RECOMMENDS A STRAIGHT END OF THE WESTERN ROW | | | OF PAVERS ALONG TANGLEWOOD RATHER THAN SLANTED, FOR | | | CONSISTENCY WITH THE REST OF THE PROJECT. | | | 10. APPLICANT SHALL SUBMIT LEVEL OF SERVICE LETTER FOR | | | TRASH COLLECTION TO PUBLIC WORKS AND TO ZONING FOR | | | DETERMINATION OF CAPACITY FOR TRASH BINS/COMPACTORS | | | PRIOR TO CO. | | | 11. APPLICANT SHALL SUBMIT MINOR AMENDMENT WITH | | | AS-BUILT PLANS (CIVIL, LANDSCAPE, SITE PLAN, | | | ARCHITECTURAL) PRIOR TO CO. | | | 12. ANY MODIFICATION TO THE PLACEMENT OF ABOVE GROUND | | | UTILITIES, INCLUDING WALL MOUNTED UTILITIES SHALL BE | | | COORDINATED WITH ZONING AS WELL AS THE OTHER | | | DEPARTMENTS. ABOVE GROUND UTILITIES SHALL NOT BE | | | LOCATED WITHIN SIDEWALK PATH CLEARANCE AND SHALL BE | | | SCREENED BY LANDSCAPE TO BEST EXTENT POSSIBLE. WALL | | | MOUNTED SHALL BE PAINTED TO MATCH BUILDING FA?ADE WHEN | | | POSSIBLE. | | | 13. ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE SCREENED. | | | 14. THE APPLICANT SHALL CONTINUE TO WORK WITH CITY | | | STAFF TO EXPLORE OPTIONS FOR THE RELOCATION OF LARGE | | | LIVE OAK TREE #18 TO AN OFF-SITE LOCATION. | | | 15. THE PROJECT SHALL MEET THE REQUIREMENT FOR ART IN | | | PUBLIC PLACES. SHEET A4-10 GARAGE SCREENING DETAIL | | | SHALL BE UPDATED AS PERMIT REVISION ONCE THE FINAL | | | SCREENING IS APPROVED BY AIPP | | | 16. NUMBER OF PARKING SPACES TO BE UPDATED THROUGH | | | REVISION TO SITE DATA PRIOR TO CO. ENSURE THAT THAT | | | COMPACT SPACES DO NOT EXCEED 30% OF PROVIDED PARKING | | | SPACES | | | 17. SHEET A1-01 SHALL BE UPDATED TO REFLECT UPDATED | | | SITE PLAN AND CIVIL PLANS (OLD MICROMOBILITY STATION | | | LOCATION, OLD COMPACTOR STAGING AREA LOCATION, PAVER | | | AREA NOT MATCHING) PRIOR TO CO | | | 18. LANDSCAPE PLAN SHALL BE UPDATED IF A PATHWAY WILL | | | BE REQUIRED ALONG WESTERN FA?ADE TO EXIT STAIRCASE. | | | 19. ADJUST GATE TO INCLUDE ADDITIONAL 1 FOOT OF SPACE | | | BETWEEN GATE AND COMPACT SPACE ON RAMP FROM FLOOR 1 TO | | | 2 | | | 20. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | | PROJECT. | | | 21. ALL STREET LIGHTS, TREE GRATES, BOLLARDS, PAVERS OR | | | ANY OTHER STREETSCAPE ELEMENTS INSTALLED WITHIN THE | | | CITY?S ROW SHALL COMPLY WITH CITY?S STANDARDS AND SHALL | | | BE APPROVED BY THE PLANNING DIVISION AND THE | | | ENGINEERING SERVICES DEPARTMENT DURING THE BUILDING | | | PERMIT PROCESS. ANY FEES ASSOCIATED WITH THE REMOVAL OF | | | EXISTING STREET LIGHTS SHALL BE A COST TO THE OWNER. | | | 22. SEPARATE PERMIT REQUIRED FOR THE FOLLOWING: | | | A. PHOTOMETRICS | | | B. LANDSCAPE (OPEN SPACE COMPLIANCE TO BE REVIEWED | | | THROUGH THIS PERMIT) | | | C. IRRIGATION | | | D. TREE REMOVAL | | | E. SIGNAGE | | | F. CONSTRUCTION FENCE SIGNAGE (NO SIGNAGE PERMITTED ON | | | BUILDING SHELL) | | | 23. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT, | | | THE APPLICANT SHALL PREPARE A CONSTRUCTION SITE | | | SECURITY AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY | | | OF WEST PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL | | | 24. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 25. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 26. IRRIGATION FOR STREET TREES AND LANDSCAPING IN THE | | | RIGHT OF WAYS SHALL BE PROVIDED BY THE APPLICANT, | | | SUCCESSORS AND ASSIGNS FROM THE SUBJECT DEVELOPMENT. | | | ALL EXISTING CITY IRRIGATION LINES RUNNING TO | | | INDIVIDUAL AREAS OR TREES SHALL BE REMOVED AND CAPPED | | | IN SUCH A WAY TO ENSURE CITY IRRIGATION SUPPLY LINES | | | SHALL REMAIN INTACT AND CONTINUOUS FOR OTHER AREAS | | | SERVED BY THE LINES | | | 27. THE OWNER SHALL CONTRIBUTE A TROLLEY FEE AT $10 PER | | | MICRO-UNIT PER MONTH. THIS PAYMENT METHOD SHALL BE | | | ESTABLISHED PRIOR TO CO. | | | 28. RECORDED SIDEWALK/ACCESS EASEMENTS SHALL BE | | | REQUIRED, AND ALL OTHER EASEMENTS DEEMED NECESSARY BY | | | THE CITY SURVEYOR. | | | 29. PAVEMENT SHALL BE RESURFACED IN ACCORDANCE WITH | | | CITY STANDARDS TO ANY AREA WHERE PAVEMENT MARKINGS ARE | | | REMOVED. | | | 30. THE OWNER SHALL BE RESPONSIBLE FOR CAPTURING ANY | | | MAJOR GRADE CHANGES WITHIN THE INTERIOR OF THE BUILDING | | | AND KEEP THE PUBLIC AREAS OF THE LOT FREE OF | | | TRIP-HAZARD CURB LINES OR ANY RAMPS. | | | 31. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION ADJACENT TO THE | | | DEVELOPMENT. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-05-01 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-05-01 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-05-01 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2020-05-01 15:43:12 | 1. THERE ARE TWO GN-00 - FIRST ONE HAS INCORRECT | | | PARKING DATA TABLE ON SHEET GN-00 DOES NOT MATCH LATEST | | | FROM APPROVED SITE PLAN, APPEARS TO BE OLDER PARKING | | | TABLE - PLEASE UPDATE | | | 2. FAR CALCULATIONS ON THIS SHEET GNB-00 DES NOT MATCH | | | LATEST APPROVED SITE PLAN AND DOES NOT MATCH SHEET | | | PZ-01- PLEASE CLARIFY - UPDATE 6/2/20 NOT APPLICABLE | | | 3. FAR CALCULATIONS: THE UNENCLOSED AND ENCLOSED | | | CORRIDOR LEADING FROM THE POOL DECK INTO THE BUILDING | | | ON BOTH THE NORTH AND SOUTH SIDE COUNT TOWARDS FAR (NOT | | | NOTICED DURING SITE PLAN REVIEW) - THIS WILL NEED TO BE | | | INCLUDED IN FAR CALCS - UPDATED 6/3/2020 NOT APPLICABLE | | | 4. THE PARKING DATA ON THE SECOND SHEET GN-00 DOESN?T | | | MATCH THE LATEST SITE PLAN APPROVAL AND SEEMS TO HAVE | | | INCORRECT NUMBERS OF SPACES BASED ON THE FLOOR PLANS | | | SUBMITTED. FOR EXAMPLE, THE NUMBER OF HC SPACES ON THE | | | FIRST FLOOR IS LISTED AS 3 12X18 AND 1 VAN ACCESSIBLE - | | | BUT THERE ARE ONLY 2 2X18. THE NUMBER OF COMPACT SPACES | | | ON LEVEL 2 IS LISTED AS 8 BUT STAFF COUNTS 9. THE TOTAL | | | SPACES ON LEVEL 1 RAMP LISTS 24 BUT STAFF COUNTS 20. | | | 5. PER CITY TRAFFIC ENGINEERING REQUIREMENT AND SITE | | | PLAN CONDITION OF APPROVAL, THE THREE PARKING SPACES | | | MARKED ?FUTURE CAR SHARE? AND ONE PARKING SPACE MARKED | | | ?RESIDENTIAL PARKING GUEST? THAT ARE LOCATED BY THE | | | OVERHANG GATE SHALL BE REMOVED OR THE OVERHANG GATE | | | SHALL BE RELOCATED TO ELIMINATE CONFLICTS. IF THE | | | SPACES ARE REMOVED, THREE OTHER GUEST SPACES MUST ALSO | | | BE RESERVED FOR ?FUTURE CAR SHARE? AND ONE ADDITIONAL | | | PARKING SPACE MUST BE RESERVED FOR ?GUEST PARKING? | | | 6. PLEASE SUBMIT LEVEL OF SERVICE LETTER FOR TRASH | | | COLLECTION TO PUBLIC WORKS AND TO ZONING FOR | | | DETERMINATION OF CAPACITY FOR TRASH BINS/COMPACTORS. | | | 7. ALL PARKING SPACES ADJACENT TO A WALL OR FIXED | | | STRUCTURE NEED AN ADDITIONAL ONE FOOT OF SPACE ? | | | PARKING SPACE ADJACENT TO MAIN ELECTRICAL ROOM ON FIRST | | | FLOOR DOES NOT HAVE ADDITIONAL ONE FOOT ? PLEASE CHECK | | | ALL FLOOR PLANS FOR THIS REQUIREMENT AND ADJUST AS | | | NECESSARY | | | 8. ADDITIONALLY, THE TOTAL SPACES LISTED IN THIS | | | PARKING DATA PER LEVEL DOES NOT MATCH THE LABEL ON THE | | | FLOOR PLANS THAT SAY "X PARKING SPACES INCLUDING RAMP | | | TO LEVEL X" - PLEASE CHECK | | | 9. SOME DIMENSIONS MISSING FROM PLAN BREAK PLANS FLOOR | | | PLAN- LEVEL 04 (SHEET PZ-02) | | | 10. PLEASE UPDATE SHEET PZ-03 WITH DATA FROM LANDSCAPE | | | PLANS ? (SEMI-PUBLIC COURTYARD NOT GARDEN PLAZA) FOR | | | CONSISTENCY | | | 11. PLEASE UPDATE ACTIVE USE PLAN SHEET PZ-04 AND | | | TRANSPARENCY PLAN SHEET PZ-05 AND HORIZONTAL PROJECTION | | | SHEET PZ-06 WITH UPDATED NORTH FA?ADE (UPDATED LOUVRE | | | DOORS). PLEASE NOTE- GLASS DOOR TO FPL ROOM DOES NOT | | | COUNT TOWARDS TRANSPARENCY PER DEFINITION OF | | | TRANSPARENCY | | | 12. THE MAIL ROOM ALONG OLIVE AVENUE, IF A SOLID WALL | | | RATHER THAN WINDOWS FACES THE ROW, THIS CANNOT BE | | | COUNTED TOWARDS ACTIVE USE OR TRANSPARENCY. IT APPEARS | | | IT WAS NOT COUNTED IN DATA, BUT IT IS HIGHLIGHTED AS | | | ACTIVE USE AND TRANSPARENCY ON THE FLOOR PLANS ON SHEET | | | PZ-04 AND PZ-05. UPDATE PLANS AS NECESSARY. PLEASE | | | CONSIDER THE USE OF WINDOWS ALONG THE MAIL ROOM. | | | 13. LANDSCAPE: THE RELOCATING PALMS WILL NOT | | | EFFECTIVELY SCREEN THE PARKING GARAGE LIKE THE | | | EVER-GREEN TREES THAT WERE PROPOSED IN SITE PLAN | | | APPROVAL. THE PALMS CAN BE RELOCATED OFF SITE - TALK TO | | | RAY CARANCI FOR OPTIONS. THE PALMS DO NOT PROVIDE | | | SUFFICIENT BUFFERING | | | 14. PLEASE REMOVE ANY CLOUD BUBBLING FROM PLANS IF OLD, | | | PLEASE INCLUDE CLOUD BUBBLING FOR ANY NEW UPDATES | | | 15. THE PORTION OF HORIZONTAL PROJECTION ON TANGLEWOOD | | | COURT FOR THE NE CORNER ELEVATION ON SHEET PZ-06 NEED | | | TO BE SHIFTED TO CONTAIN THE CORRECT AREA | | | 16. PLEASE REMOVE PHOTOMETRIC PLAN SHEET PZ-07 FROM | | | PLAN SET ? TO BE REVIEWED THROUGH SEPARATE PERMIT | | | (REMINDER THAT SEMI PUBLIC COURTYARD AND ALL BUILDING | | | ENTRANCES NEED TO BE INCLUDED IN PHOTOMETRIC PLAN) | | | PLEASE LOOK AT THE EASTERN MOST LIGHT POLE PROPOSED ON | | | TANGLEWOOD COURT AND ITS PROXIMITY TO THE FIRE HYDRANT | | | ? CHECK WITH BUILDING/FIRE DEPT FOR PERMITTED LOCATION | | | AND PROXIMITY) ? SUBMIT LANDSCAPE PLAN WITH LIGHT POLES | | | SHOWN WITH PHOTOMETRIC PERMIT | | | 17. PLEASE RELOCATE PUBLIC USE BIKE RACKS TO CONCRETE | | | AREA NOT WITHIN MAIN PATH OF TRAVEL TO AVOID HAVING | | | CONCRETE PAD IN MIDDLE OF PAVER AREA | | | 18. BENCH WITHIN SETBACK AREA CANNOT BE MORE THAN 42? | | | TALL ? PLEASE INCLUDE DETAIL OF BENCH AND HEIGHT | | | 19. ALL BENCHES SHALL HAVE CENTER BAR TO DETER | | | LOITERING ? PLEASE INCLUDE DETAIL | | | 20. HOW WILL PAVER AREA TRANSITION INTO ADA RAMP AT | | | PROJECT?S SOUTHEAST CORNER? WILL LARGE CONCRETE BAND BE | | | REQUIRED? PLEASE CONSIDER | | | 21. PLEASE CHECK WITH MARK HURLEY ON DISTANCE BETWEEN | | | BACKFLOW PREVENTER AND PROPOSED TREE ? DETERMINE IF | | | TREE NEEDS TO BE SHIFTED TO ACCOMMODATE | | | 22. PLEASE REMOVE LABEL REFERENCING RELOCATED LIVE OAK | | | TREE FROM ENLARGED 1ST FLOOR PLAN SHEET A1-01A | | | 23. THERE IS PARKING SPACE ALONG THE NORTH FA?ADE WITH | | | A LABEL ON FLOOR PLAN LEVEL 2 SHEET A1-02 THAT | | | REFERENCES A TURNAROUND AND BACKUP SPACE, BUT THE SPACE | | | ALSO IS LABELED AS A COMPACT SPACE | | | 24. ENLARGED PLANS A AND B DO NOT MATCH THE OVERALL | | | FLOOR PLAN FOR EACH LEVEL 2-8 INCLUDING SUCH ITEMS AS | | | DOUBLE STRIPING FOR PARKING, BALCONIES, PARKING | | | CONFIGURATION ETC. PLEASE UPDATE ALL AS NECESSARY | | | 25. THE RENDERING OF THE SOUTHEAST VIEW SHOWS A GLASS | | | WINDOW WHERE THE LOUVRED DOOR WAS ORIGINALLY PROPOSED | | | ALONG TANGLEWOOD CT, BUT THE ELEVATIONS AND FLOOR PAN | | | DO NOT INDICATE A WINDOW. PLEASE UPDATE ELEVATIONS AND | | | FLOOR PLAN TO REFLECT IF THERE IS A WINDOW IN THIS | | | LOCATION, WHICH IS PREFERRED BY STAFF. | | | 26. THE WIDTH OF THE EASTERN MOST ROW OF BALCONIES | | | (CLOSEST TO OLIVE AVENUE) ALONG THE NORTH FA?ADE | | | APPEARS WIDER ON THE ELEVATION AND FLOOR PLAN THAN ON | | | THE RENDERING ? PLEASE ADJUST AS NECESSARY. | | | 27. IT APPEARS THAT THE NORTH PORTION OF THE BIKE | | | STORAGE MAY ONLY HAVE A 6-FOOT HEIGHT CLEARANCE ? | | | CONFIRM WITH BUILDING DEPARTMENT IF THIS WILL BE AN | | | ISSUE FOR BICYCLE STORAGE AND ADJUST IF NECESSARY | | | 28. ADDITIONAL DEPTH WAS ADDED TO THE WEST ELEVATION OF | | | THE SOUTH GARAGE ENTRANCE THROUGH CMU WALL ? IS THIS | | | ACCURATELY REFLECTED IN RENDERINGS AND ELEVATIONS? | | | 29. IS THE STAIRCASE LEADING FROM THE POOL DECK NOT | | | COVERED? DO NOT SEE INDICATION OF COVERING ON 4TH FLOOR | | | ELEVATION OR ON RENDERINGS ? PLEASE CLARIFY | | | 30. PLEASE INCLUDE DETAIL FOR SF-11 AND SF-17 FOR | | | DOORWAYS. ARE THESE DOORWAYS ALSO GLASS? THEY DO THEY | | | APPEAR NOT GLASS ON COLOR ELEVATIONS | | | 31. WILL THERE BE A GATE AT THE ENTRANCE TO THE | | | PEDESTRIAN PASEO? WHAT CAN BE DONE TO BLOCK VIEW OF THE | | | PARKING GARAGE AND RAMP FROM THE SIDEWALK? | | | 32. ON THE EAST ELEVATION, THERE APPEARS A BOX ON THE | | | SIDEWALK ADJACENT TO A LIGHT POLE ALONG THE NORTH | | | (ALONG TANGLEWOOD CT) ? WHAT IS THIS? | | | 33. CROSS SLOPES EXCEED MAX. PERMITTED WITHIN ROW - | | | DISCUSSIONS ONGOING WITH CITY ENG AND KIMLEY HORN. | | | PLEASE UPDATE WHEREVER NECESSARY ONCE FINAL IS APPROVED | | | THROUGH ENG | | | 34. PLEASE UPDATE GARAGE SCREEN ENLARGED ELEVATION | | | SHEET A4-10 WITH AICP CONCEPT PAGES OR FINAL SELECTION | | | ? AN AMENDMENT FOR THE GARAGE SCREENING WILL NEED TO BE | | | SUBMITTED IF THE FINAL SELECTION IS MADE AFTER THE | | | BUILDING PERMIT IS APPROVED | | | 35. STAFF NOTICED THAT SHEET A5-10, A5-11, A5-13 DO NOT | | | MATCH PARAPET HEIGHT AND MISSING CANOPY ALONG NORTH | | | SIDE. SHEET A5-21 OLD PARKING ENTRANCE DESIGN. PLEASE | | | ENSURE ALL WALL SECTIONS AND ENLARGED ELEVATION SHEETS | | | ARE UPDATED TO MATCH MOST CURRENT ARCHITECTURAL DESIGN | | | 36. SHEET A5-12: IN THE CASE THAT THE ART IS NOT | | | APPROVED BY AIPP OR ANOTHER AREA ON THE BUILDING/GROUND | | | IS PICKED FOR THE AIPP, THE PERFORATED METAL SQUARE | | | LATTICE WITHIN THE PROPOSED ART BOX SHALL HAVE TO BE | | | RECONSIDERED. THE ART WALL FRAME ITSELF MAY NEED TO BE | | | RECONSIDERED. | | | 37. SHEET A5-20 REFERENCES THE NEED FOR LIGHTS TO BE AT | | | THE PARKING GARAGE ENTRANCES ? THESE NEED TO BE | | | SHIELDED FROM PUBLIC ROW TO THE BEST EXTENT POSSIBLE | | | 38. SHEET A6-01 HAS OLD BICYCLE STORAGE ROOM DETAIL ? | | | PLEASE REMOVE | | | 39. SHEET A6-01 LABELS ?ENLARGED PLAN- MAINTENANCE | | | ROOM? BUT THE IMAGE IS OF COMPACT PARKING SPACES. | | | PLEASE UPDATE AS NECESSARY. PET SPA DETAIL ON SHEET | | | A6-01 DOES NOT MATCH FLOOR PLAN | | | 40. SHEET A6-02 DOES NOT MATCH UPDATED FLOOR PLAN. | | | PLEASE ENSURE SHEET A6-03 IS UPDATED IF NECESSARY | | | 41. PARTIAL FOUNDATION PLAN S100A AND S100B DO NOT | | | MATCH FLOOR PLAN ? SUGGEST REMOVING ROM PERMIT SET | | | UNLESS BUILDING DEPT NEEDS THESE SHEETS. IF THEY NEED | | | THEM, PLEASE UPDATE. RECOMMEND SAME FOR PARTIAL FRAMING | | | PLANS IF THEY DON?T MATCH FOR PLAN CONSISTENCY | | | 42. PLEASE REMOVE PHOTOMETRIC PLANS FOR FIRST LEVEL AND | | | GARAGE AND SUBMIT SEPARATE PERMIT | | | 43. PLEASE INCLUDE UPDATED CONTEXTUAL ELEVATIONS WITH | | | UPDATED DISTANCE BETWEEN PROPOSED STRUCTURE AND TWO | | | CITY PLAZA AS REQUIRED BY SITE PLAN CONDITION OF | | | APPROVAL | | | 44. PLEASE CONSIDER AN ADDITIONAL DOOR LEADING TO | | | RETAIL/RESTAURANT SPACE ALONG NORTH FA?ADE | | | | | | PROPOSED PROVISOS: | | | 1. ALL ROOFTOP EQUIPMENT SHALL BE SCREENED IF NOT DONE | | | SO THROUGH RAISED PARAPET. | | | 2. ALL LANDSCAPING AND IRRIGATION TO BE TO BE REVIEWED | | | THROUGH SEPARATE PERMIT | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | | PROJECT. | | | 4. ALL STREET LIGHTS, TREE GRATES, BOLLARDS, PAVERS OR | | | ANY OTHER STREETSCAPE ELEMENTS INSTALLED WITHIN THE | | | CITY?S ROW SHALL COMPLY WITH CITY?S STANDARDS AND SHALL | | | BE APPROVED BY THE PLANNING DIVISION AND THE | | | ENGINEERING SERVICES DEPARTMENT DURING THE BUILDING | | | PERMIT PROCESS. ANY FEES ASSOCIATED WITH THE REMOVAL OF | | | EXISTING STREET LIGHTS SHALL BE A COST TO THE OWNER. | | | 5. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT, | | | THE APPLICANT SHALL PREPARE A CONSTRUCTION SITE | | | SECURITY AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY | | | OF WEST PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. | | | 6. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 7. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 8. IRRIGATION FOR STREET TREES AND LANDSCAPING IN THE | | | RIGHT OF WAYS SHALL BE PROVIDED BY THE APPLICANT, | | | SUCCESSORS AND ASSIGNS FROM THE SUBJECT DEVELOPMENT. | | | ALL EXISTING CITY IRRIGATION LINES RUNNING TO | | | INDIVIDUAL AREAS OR TREES SHALL BE REMOVED AND CAPPED | | | IN SUCH A WAY TO ENSURE CITY IRRIGATION SUPPLY LINES | | | SHALL REMAIN INTACT AND CONTINUOUS FOR OTHER AREAS | | | SERVED BY THE LINES | | | 9. THE OWNER SHALL WORK WITH CITY STAFF TO KEEP | | | TANGLEWOOD COURT, TRINITY PLACE AND OLIVE AVENUE OPEN | | | FOR VEHICLES AND PEDESTRIANS BY MEANS OF SCAFFOLDING OR | | | OTHER MEASURES TO THE MOST EXTENT POSSIBLE THROUGHOUT | | | THE CONSTRUCTION PROCESS. | | | 10. THE OWNER SHALL COORDINATE WITH THE CITY PARKING | | | ADMINISTRATION FOR THE REMOVAL AND RELOCATION OF | | | ON-STREET PARKING SPACES. | | | 11. THE PROJECT SHALL MEET THE REQUIREMENT FOR ART IN | | | PUBLIC PLACES. | | | 12. THE OWNER SHALL CONTRIBUTE A TROLLEY FEE AT $10 PER | | | MICRO-UNIT PER MONTH. THIS PAYMENT METHOD SHALL BE | | | ESTABLISHED PRIOR TO CO. | | | 13. RECORDED SIDEWALK/ACCESS EASEMENTS SHALL BE | | | REQUIRED, AND ALL OTHER EASEMENTS DEEMED NECESSARY BY | | | THE CITY SURVEYOR. | | | 14. PAVEMENT SHALL BE RESURFACED IN ACCORDANCE WITH | | | CITY STANDARDS TO ANY AREA WHERE PAVEMENT MARKINGS ARE | | | REMOVED. | | | 15. THE OWNER SHALL BE RESPONSIBLE FOR CAPTURING ANY | | | MAJOR GRADE CHANGES WITHIN THE INTERIOR OF THE BUILDING | | | AND KEEP THE PUBLIC AREAS OF THE LOT FREE OF | | | TRIP-HAZARD CURB LINES OR ANY RAMPS. | | | 16. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION ADJACENT TO THE | | | DEVELOPMENT. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-02-21 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-02-21 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-02-21 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2020-02-21 16:48:41 | SITE PLAN APPROVAL NOT YET GRANTED | | | | | | PLEASE UPLOAD ALL UPDATED PLANS TO MATCH SITE PLAN | | | APPROVAL PLANS ONCE IT HAS BEEN GRANTED | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
|
Account Summary | Usage Policy | Privacy Policy