Plan Review Details - Permit 20010876
Plan Review Stops For Permit 20010876
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2020-04-05 Cont ID  
Sent By jwitmer Date 2020-02-10 Time 11:14 Rev Time 0.00
Received By jwitmer Date 2020-02-10 Time 10:58 Sent To  
Notes
2020-02-10 11:11:50NEW CONSTRUCTION. NOT REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-04-05 Cont ID  
Sent By jwitmer Date 2020-04-05 Time 13:14 Rev Time 0.00
Received By jwitmer Date 2020-04-05 Time 12:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-16 Cont ID  
Sent By jwitmer Date 2020-03-16 Time 12:33 Rev Time 0.00
Received By jwitmer Date 2020-03-16 Time 11:02 Sent To  
Notes
2020-03-16 12:33:462017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20010876
 ADD: 7000 OKEECHOBEE BLVD. (CORRECTED ADDRESS) BUILDING
 # 2/ STARBUCKS INTERIOR BUILD-OUT
 CONT: TBD/ TO BE DETERMINED
 TEL: 954-583-9990
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2ND REVIEW
 DATE: MON. MARCH 16TH/2020
 ACTION: DENIED
  
 1A) 2ND REQUEST. THE RESPONSE LETTER STILL IS WRONG.
 OKEECHOBEE BLVD. RUNS EAST TO WEST. THE FURTHER WEST
 YOU GO ON OKEECHOBEE BLVD. THE HIGHER THE ADDRESSES.
 STARBUCKS IS TO BE LOCATED IN BUILDING # 2 WHICH IS THE
 SMALLER OF THE 2 BUILDING FOOT PRINTS. STARBUCKS IS
 ALSO THE FURTHEST EAST OF THE 2 BUILDINGS ON THIS LOT.
 THE ADDRESS FOR THE SHELL BUILDING FOR BUILDING # 2
 (STARBUCK THE TENANT) IS 7000 OKEECHOBEE BLVD. SHELL
 BUILD. B IS PERMIT 19081537.
  
 THE LARGER BUILDING, BUILDING # 1 WITH FOOTPRINT OF
 8,180 SQ. FT. IS 7030 OKEECHOBEE BLVD. THE FURTHER WEST
 YOU GO ON OKEECHOBEE BLVD. THE HIGHER THE BUILDING
 NUMBER. CORRECT ALL OF THE SHEETS ADDRESSES.
  
 1B) NEW COMMENT. CORRECT THE SHEET G-001 THE LAND LORD
 SHELL PERMIT IS NOT 19090177 FOR BUILDING # 2 WHERE
 STARBUCKS IS THE PROPOSED TENANT. THE PERMIT NUMBER
 19090177 IS FOR THE SHELL PERMIT FOR BUILD. # 1, AN
 8,180 SQ. FT. VANILLA BOX RETAIL SHELL BUILDING.
  
 1ST ROUND OF COMMENTS. PLEASE CORRECT THE ADDRESS IN
 THE TITLEBLOCK FOR ALL OF THE PLANS. THE ADDRESS AS
 GIVEN IN THE TITLEBLOCK IS 7030 OKEECHOBEE BLVD. THIS
 ADDRESS IS FOR BUILDING # 1, A 8180 SQ. FT. BUILDING.
 THE SHELL PERMIT FOR BUILDING # 2 IS 19081537 AND 2,364
 SQUARE FEET AND HAS THE CORRECT ADDRESS WITHIN THE
 TITLEBLOCK OF 7000 OKEECHOBEE BLVD. THE CITY HAS
 CORRECTED THE TENANT BUILD-OUT ADDRESS ON THE PERMIT
 APPLICATION AND IN OUR RECORDS, PLEASE UPDATE THE
 SUBMITTED PLANS TO THE CORRECT ADDRESS.
  
 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED.
 2017 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-10 Cont ID  
Sent By jwitmer Date 2020-02-10 Time 14:16 Rev Time 0.00
Received By jwitmer Date 2020-02-10 Time 10:58 Sent To  
Notes
2020-02-10 14:14:142017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20010876
 ADD: 7000 OKEECHOBEE BLVD. (CORRECTED ADDRESS) BUILDING
 # 2/ STARBUCKS INTERIOR BUILD-OUT
 CONT: TBD/ TO BE DETERMINED
 TEL: 954-583-9990
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 1ST REVIEW
 DATE: MON. FEB. 10/2020
 ACTION: DENIED
  
 1) PLEASE CORRECT THE ADDRESS IN THE TITLEBLOCK FOR ALL
 OF THE PLANS. THE ADDRESS AS GIVEN IN THE TITLEBLOCK IS
 7030 OKEECHOBEE BLVD. THIS ADDRESS IS FOR BUILDING # 1,
 A 8180 SQ. FT. BUILDING. THE SHELL PERMIT FOR BUILDING
 # 2 IS 19081537 AND 2,364 SQUARE FEET AND HAS THE
 CORRECT ADDRESS WITHIN THE TITLEBLOCK OF 7000
 OKEECHOBEE BLVD.. THE CITY HAS CORRECTED THE TENANT
 BUILD-OUT ADDRESS ON THE PERMIT APPLICATION AND IN OUR
 RECORDS, PLEASE UPDATE THE SUBMITTED PLANS TO THE
 CORRECT ADDRESS.
  
 2017 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED.
 2017 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-04-03 Cont ID  
Sent By jpearson Date 2020-04-03 Time 14:09 Rev Time 0.00
Received By jpearson Date 2020-04-03 Time 13:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-03-17 Cont ID  
Sent By jleahy Date 2020-03-17 Time 14:33 Rev Time 0.00
Received By jleahy Date 2020-03-17 Time 14:27 Sent To  
Notes
2020-03-17 14:34:18VALUE OF PERMIT HAS NOT CHANGED JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-02-02 Cont ID  
Sent By jleahy Date 2020-02-02 Time 10:58 Rev Time 0.00
Received By jleahy Date 2020-02-02 Time 09:44 Sent To  
Notes
2020-02-02 11:01:10 
  
  
 1) VALUE FOR WORK SHOWN TOO LOW. PLEASE SUBMIT A SIGNED
 CONTRACT FOR THE WORK INVOLVED.
  
 2) FAULT CURRENT CALCULATION REQUIRED FOR SERVICE AND
 NEW PANEL. 110.24(B) FOR MODIFICATIONS

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-03-17 Cont ID  
Sent By sathomas Date 2020-03-17 Time 00:00 Rev Time 0.00
Received By sathomas Date 2020-03-17 Time 00:00 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-01-28 Cont ID  
Sent By sathomas Date 2020-01-28 Time 00:00 Rev Time 0.00
Received By sathomas Date 2020-01-28 Time 00:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-04-08 Cont ID  
Sent By lmarchan Date 2020-04-08 Time 15:22 Rev Time 0.00
Received By lmarchan Date 2020-04-02 Time 16:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-25 Cont ID  
Sent By shill Date 2020-03-25 Time 13:27 Rev Time 0.00
Received By shill Date 2020-03-11 Time 11:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-02-10 Time   Rev Time 0.00
Received By cpuell Date 2020-01-22 Time 14:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2020-04-05 Cont ID  
Sent By jwitmer Date 2020-04-05 Time 13:15 Rev Time 0.00
Received By jwitmer Date 2020-04-05 Time 13:15 Sent To  
Notes
2020-04-05 13:16:29IMPACT FEES PAID ON THE SHELL BUILDING.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-02-10 Cont ID  
Sent By jwitmer Date 2020-02-10 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2020-02-10 Time 10:58 Sent To  
Notes
2020-02-10 14:17:44PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-04-08 Cont ID  
Sent By ccole Date 2020-04-08 Time 07:56 Rev Time 0.00
Received By ccole Date 2020-04-06 Time 16:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-03-25 Cont ID  
Sent By ccole Date 2020-03-25 Time 08:35 Rev Time 0.00
Received By ccole Date 2020-03-24 Time 13:22 Sent To  
Notes
2020-03-25 09:07:532ND REVIEW FBC-2017 MECHANICAL
 PERMIT #20010876
 3/25/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS M001, M002, M101, & M601: AS PREVIOUSLY NOTED
 IN THE 1ST REVIEW, THE RTU'S FOR STARBUCKS WERE
 INSTALLED UNDER PERMIT #19010177. PLEASE CORRECT THE
 REFERENCES TO PERMIT #19081537 - SECTION 107.2.1 WPB.
  
 2) UNDER PERMIT #19090177, THE ENGINEER OF RECORD TODD
 W. CAREY P.E DID NOT PROVIDE EITHER ENERGY OR AC
 CALCULATIONS ACCORDING TO WHAT HE SAID WAS FROM
 STARBUCK'S DIRECTION. THE CALCULATIONS WERE TO BE
 SUBMITTED UNDER THE TENANT BUILD-OUT WHICH IS THIS
 PERMIT #20010876. THERE WERE PROVISOS PLACED ON THE
 APPROVED PLAN SHEET M.101 UNDER PERMIT #19090177
 STATING THAT THE CALCULATIONS WOULD BE PROVIDED UNDER
 THE TENANT BUILD-OUT. CURRENTLY AC CALCULATIONS HAVE
 BEEN SUBMITTED BUT NOT THE ENERGY CALCULATIONS AS
 REQUIRED BY SECTION C101.5 FBC EC. PLEASE SUBMIT AN
 ENERGY COMPLIANCE REPORT USING EITHER THE PRESCRIPTIVE
 OR PERFORMANCE BASED METHOD- SEE SECTION C401.2 FOR
 FURTHER COMPLIANCE INFORMATION.
  
 3) SHEETS M002 & M601: RTU-1 AT 10 TONS OF COOLING AND
 RTU-2 AT 8.5 TONS OF COOLING ARE OVERSIZED ACCORDING TO
 THE HEAT LOAD CALCS WHICH INDICATE 16 TONS OF COOLING
 REQUIRED- SECTION C403.2.2 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-02-06 Cont ID  
Sent By ccole Date 2020-02-06 Time 15:54 Rev Time 0.00
Received By ccole Date 2020-02-06 Time 13:16 Sent To  
Notes
2020-02-06 16:11:251ST REVIEW FBC-2017 MECHANICAL
 PERMIT #20010876
 2/6/2020
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE COMPLETE COOLING AND HEATING CALCULATIONS
 FOR THE RTU'S- SECTION C403.2.1 FBC EC. SHEET M001
 CONTAINS ONLY PAGE 1 OF 3.
  
 2) VERFIY THE NEW RTU'S WILL BE EQUIPPED WITH
 AUTOMATICALLY CONTROLLED SHUTOFF DAMPERS FOR O/A-
 SECTION C403.2.4.3 FBC EC.
  
 3) SUBMIT AN ENERGY COMPLIANCE REPORT USING EITHER THE
 PRESCRIPTIVE OR PERFORMANCE BASED COMPLIANCE PATH AS
 REQUIRED BY SECTION C101.5 FBC EC.
  
 4) M601: MIAMI-DADE NOA #14-1224.10 FOR THE AC
 CONDENSER STANDS HAS EXPIRED. PLEASE UPDATE THE NOA
 NUMBER AND SUBMIT THE DOCUMENT- RULE 9N-3 FAC. PLEASE
 NOTE THIS MAY BE A DEFERRED SUBMITTAL IF NECESSARY-
 SECTION 107.3.4.1 WPB.
  
 5) G-004: SUBMIT MANUFACTURER'S SPECS FOR THE TURBO
 CHEF OVENS. PLEASE NOTE THAT IN ACCORDANCE WITH SECTION
 507.3 WILL REQUIRE EITHER A TYPE II EXHAUST HOOD OR AN
 EXHAUST FAN SIZED AT .70 CFMS PER SF. THE DEFAULT
 SQUARE FOOTAGE NOTED IN THE CODE SECTION IS 100 SF.
  
 6) M601: CORRECT THE LANDLORD PERMIT # B-19-232701-000
 LISTED IN THE RTU SCHEDULE. THE LANDLORD'S SHELL PERMIT
 WAS #19090177.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-04-07 Cont ID  
Sent By jpearson Date 2020-04-07 Time 13:25 Rev Time 0.00
Received By jpearson Date 2020-04-07 Time 12:34 Sent To  
Notes
2020-04-07 12:34:08REVIEWED BY JERRY SMITH

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-03-25 Cont ID  
Sent By jesmith Date 2020-03-25 Time 13:27 Rev Time 0.00
Received By shill Date 2020-03-25 Time 09:05 Sent To  
Notes
2020-03-25 13:27:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 20010876 7000 OKEECHOBEE BLVD
  
 2ND REVIEW
 PLUMBING COMMENTS: APPROVED W/PROVISO
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 I.PLUMBING PROVISO
 1. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE
 AS A DEFERRED SUBMITTAL MANUFACTURER?S SPECIFICATION
 AND INSTALLATION GUIDE FOR ALL SPECIALTY EQUIPMENT
 FURNISHED BY OWNER/VENDORS REQUIRING PLUMBING WATER
 AND/OR WASTE CONNECTIONS. DOCUMENT SHALL BE SUBMITTED,
 APPROVED AND ON SITE PRIOR TO FINAL INSPECTION. PROCEED
 AT YOUR OWN RISK.
 2. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, A PLAN
 REVISION SHALL BE SUBMITTED OF A RECORD DRAWING.
 DOCUMENT SHALL BE SUBMITTED, APPROVED AND ON SITE PRIOR
 TO FINAL INSPECTION. PROCEED AT YOUR OWN RISK.
 3. RE: PLAN SHEET P-501 AND P-011; WATER HEATER DETAIL
 AND TEMPERED WATER; TEMPERED WATER SHALL BE DELIVERED
 FROM LAVATORIES AND GROUP WASH FIXTURES LOCATED IN
 PUBLIC TOILET FACILITIES PROVIDED FOR CUSTOMERS,
 PATRONS AND VISITORS. TEMPERED WATER SHALL BE DELIVERED
 THROUGH AN APPROVED WATER-TEMPERATURE LIMITING DEVICE
 THAT CONFORMS TO ASSE 1070 OR CSA B125.3 PER FBC PL
 416.5. DEVICE IS POINT OF USE AND ONE EACH SHALL BE
 PROVIDED AT EACH FIXTURE, NOT AT THE WATER HEATER.
 4. PER FBC PL 608.3, PROVIDE BACKFLOW PREVENTERS AT ALL
 POTABLE COLD AND FILTERED WATER CONNECTIONS TO THE
 FOLLOWING ITEMS: ICE MACHINES, COFFEE/EXPRESSO MAKERS,
 CARBONATED DRINK DISPENSERS, SANITIZERS, WATER PUMPS,
 FILTERS, SOFTENERS, TANKS AND OTHER DEVICES THAT HANDLE
 OR TREAT POTABLE AND/OR FILTERED WATER.
 DISCHARGE OF DRAINS FROM FORE MENTIONED EQUIPMENT AND
 BACKFLOW PREVENTERS SHALL DISCHARGE TO THE APPROPRIATE
 TRAPPED AND VENTED OPEN RECEPTACLE THROUGH AN AIR GAP
 IN ACCORDANCE WITH FBC PL 608.13.1
 5. PROVIDE TRAP SEAL PROTECTION FOR ALL FLOOR DRAINS
 PER FBC PL 1002.4.1.
 II. PLUMBING PROVISO: THE FOLLOWING NOTES ARE A
 CLARIFICATION OF FBC ACC REQUIREMENTS AND SHALL PREVAIL
 IN EVENT CONFLICTING INFORMATION PROVIDED ON THE PLAN;
 SEE PLAN SHEETS I-401 AND I-40101
 A. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2
 B. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 C. TURNING SPACE SHALL COMPLY WITH FBC ACC 304.3.1 OR
 304.3.2.
 D. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL PER FBC ACC 604.5.1
 E. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 F. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
 HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH 309.
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET PER FBC ACC 604.6
 G. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 H. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE
 FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 I. UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED PER FBC ACC 602.2
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 20010876 7000 OKEECHOBEE BLVD
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-02-07 Cont ID  
Sent By gjohnson Date 2020-02-07 Time 13:01 Rev Time 0.00
Received By gjohnson Date 2020-02-06 Time 15:03 Sent To  
Notes
2020-02-07 13:32:331ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. GRAB BARS SHALL BE MEASURED FROM FINISHED FLOOR TO
 THE TOP OF THE GRIPPING SURFACE. PER FBC ACC 609.4
  
 2. THE REAR GRAB BARS SHALL BE 36" MIN AND EXTEND 12"
 MIN FROM CENTERLINE OF THE TOILET AND 24" MIN ON THE
 OTHER SIDE. PER FBC ACC 604.5.2
  
 3. THE TOILET DISPENSER SHALL BE 15"- 48" MAX OFF
 FINISHED FLOOR AND 7" - 9" OFF THE FRONT OF THE TOILET.
 FBC ACC 604.7
  
 4. FULL PORT SHUT OFF ARE REQUIRED ON EACH DROP ON THE
 WATER SYSTEM. PER FBC PL 606.1(5)
  
 5. PROVIDE SIZING CALCULATIONS FOR GREASE INTERCEPTOR.
 PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-04-08 Cont ID  
Sent By ccole Date 2020-04-08 Time 08:07 Rev Time 0.00
Received By ccole Date 2020-04-08 Time 07:57 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-03-25 Cont ID  
Sent By shill Date 2020-03-25 Time 09:07 Rev Time 0.00
Received By shill Date 2020-03-25 Time 09:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2020-02-10 14:20:55CHECKED THE ARCHITECTS SHEETS FOR DIGITAL SIGNATURES.
 OK. 02/10/2020. JW

Review Stop Z ZONING
Rev No 1 Status P Date 2020-01-31 Cont ID  
Sent By hdanfort Date 2020-01-31 Time 11:02 Rev Time 0.00
Received By hmtribou Date 2020-01-31 Time 11:02 Sent To I
Notes
***NONE***