Plan Review Details - Permit 20010400
Plan Review Stops For Permit 20010400
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-02-03 Cont ID  
Sent By pvalenti Date 2020-02-03 Time 08:57 Rev Time 0.00
Received By pvalenti Date 2020-02-03 Time 06:48 Sent To  
Notes
2020-02-03 09:49:08PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 1. FBC B 107.3.4.1, PROVIDE (DESIGNER OF RECORD REVIEW
 STAMPED AND SIGNED) DEFERRED SUBMITTALS INCLUDING
 PRODUCT APPROVALS FOR GARAGE DOORS, ROOF MATERIALS AND
 ROOF ENGINEERING.
  
  
 NOTES:
 1. A ROOFING SUB PERMIT IS REQUIRED.
 2. THE DEMO PERMIT NEEDS TO BE APPROVED.
 3. COUNTY IMPACT FEE REVIEW HAS NOT APPROVED.
 4. THERE IS A DESCREPANCY BETWEEN THE ARCHITECT'S SEER
 REQUIREMENT OF A/C EQUIPMENT ON PAGE A-001 AND THE
 EQUIPMENT INDICATED ON THE MECHANICAL PLANS AND ENERGY
 CALCULATIONS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-06-22 Cont ID  
Sent By jleahy Date 2020-06-22 Time 11:49 Rev Time 0.00
Received By jleahy Date 2020-06-22 Time 11:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-02-06 Cont ID  
Sent By jpearson Date 2020-02-06 Time 15:42 Rev Time 0.00
Received By jpearson Date 2020-02-06 Time 07:03 Sent To I
Notes
2020-02-06 15:42:33CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 2. PROVIDE AIC RATING OF ANY SERVICE DISCONNECTS AND
 PANELS. NEC 110.3, 110.9; FBC RE E3606.3
 3. FEED FROM ATS TO MAIN PANEL IS REQUIRED TO HAVE AN
 EQUIPMENT GROUNDING CONDUCTOR, SIZED PER CODE.
 ADDITIONALLY, AND SUB-PANEL FED FROM A PANEL AFTER THE
 FIRST MEANS OF DISCONNECT IS REQUIRED TO HAVE THE EGC.
 PROVIDE CORRECTION FOR ALL FEEDERS. NEC 250.122; FBC RE
 E3704.6, 3607.3.1
 4. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. LOAD CALCULATIONS ARE SHOWN FOR
 INDIVIDUAL PANELS, BUT NOT FOR THE SERVICE. NEC 215.2,
 220, 408.30; FBC RE E3602.2
 5. ELECTRICAL PLAN SHOWS A 200 AMP SERVICE WITH A 200
 AMP TRANSFER SWITCH. RISER DIAGRAM SHOWS A 400 AMP
 SERVICE WITH A 400 AMP TRANSFER SWITCH. CORRECT
 DISCREPANCY. WPB FBC 107.2.1
 6. RISER DIAGRAM SHOWS A 2/0 FEEDER FOR A 200 AMP
 PANEL. THIS WIRE IS NOT SIZED PROPERLY. WIRE SIZES FROM
 NEC 310.15(B)(7), OR FBC RE E3603.1, CAN ONLY BE USED
 WHEN THE SERVICE CONDUCTOR SUPPLIES 100% OF THE LOAD.
 SINCE THIS IS NOT THE CASE, PROVIDE CORRECTED WIRE SIZE
 FOR THIS FEEDER. NEC 310.15(B)(7) AND (B)(16); FBC RE
 E3603.1, E3705.1
 7. RISER DIAGRAM SHOWS A #4 FEEDER FOR A 100 AMP PANEL
 IN TWO LOCATIONS. THIS WIRE IS NOT SIZED PROPERLY. WIRE
 SIZES FROM NEC 310.15(B)(7), OR FBC RE E3603.1, CAN
 ONLY BE USED WHEN THE SERVICE CONDUCTOR SUPPLIES 100%
 OF THE LOAD. SINCE THIS IS NOT THE CASE, PROVIDE
 CORRECTED WIRE SIZE FOR THIS FEEDER. NEC 310.15(B)(7)
 AND (B)(16); FBC RE E3603.1, E3705.1
 8. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 9. PROVIDE GFCI PROTECTION FOR DISHWASHERS. NEC
 210.8(D); FBC RE E3902.10
 10. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING
 PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK
 IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY
 OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1
 11. BREAKER FOR POOL PUMP REQUIRED TO BE GFCI
 PROTECTED. PROVIDE CORRECTION. NEC 680.21(C); FBC RE
 E4203.1.3
 12. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2
 13. LIGHTING IN CLOSETS IS SHOWN AS A J-BOX FOR A
 CELING MOUNTED OR HANGING DECORATIVE FIXTURE. PER CODE,
 LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS AND
 PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE
 PERMITTED IN CLOTHES CLOSETS. PROVIDE A BLOCK NOTE THAT
 COMPLIANCE IS REQUIRED. NEC 410.16; FBC RE E4003.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-01-16 Cont ID  
Sent By lcrespo Date 2020-01-16 Time 07:05 Rev Time 0.00
Received By lcrespo Date 2020-01-16 Time 07:05 Sent To  
Notes
2020-01-16 07:06:03GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-01-30 Cont ID  
Sent By fmittner Date 2020-01-30 Time 16:08 Rev Time 0.00
Received By fmittner Date 2020-01-30 Time 16:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-06-22 Cont ID  
Sent By pvalenti Date 2020-06-22 Time 14:06 Rev Time 0.00
Received By pvalenti Date 2020-06-22 Time 12:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-02-06 Time   Rev Time 0.00
Received By lmarchan Date 2020-01-13 Time 13:51 Sent To  
Notes
2020-01-14 13:51:23R24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2020-07-27 Cont ID  
Sent By lmarchan Date 2020-07-27 Time 10:33 Rev Time 0.00
Received By lmarchan Date 2020-06-22 Time 16:23 Sent To  
Notes
2020-07-24 12:05:24MU-2020-021804 - $1463.48 - PAID
2020-06-22 16:23:276/22/20 SENT TO IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2020-06-22 Cont ID  
Sent By pvalenti Date 2020-06-22 Time 14:03 Rev Time 0.00
Received By pvalenti Date 2020-06-22 Time 14:01 Sent To  
Notes
2020-06-22 14:03:11PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 IMPACT FEE REVIEW DENIED:
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233?5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2020-06-01 Cont ID  
Sent By shill Date 2020-06-01 Time 13:51 Rev Time 0.00
Received By shill Date 2020-06-01 Time 13:51 Sent To  
Notes
2020-06-01 13:52:09PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-02-03 Cont ID  
Sent By pvalenti Date 2020-02-03 Time 07:29 Rev Time 0.00
Received By pvalenti Date 2020-02-03 Time 06:48 Sent To  
Notes
2020-02-03 07:31:01IMPACT FEES - PAPER SUBMITTALS
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-06-03 Cont ID  
Sent By pvalenti Date 2020-06-03 Time 14:31 Rev Time 0.00
Received By pvalenti Date 2020-06-03 Time 14:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-02-03 Cont ID  
Sent By pvalenti Date 2020-02-03 Time 06:18 Rev Time 0.00
Received By pvalenti Date 2020-02-01 Time 13:23 Sent To  
Notes
2020-02-03 06:42:12***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW DENIED:
  
 1. FBC B 107.2.1, THE NOTES FOUND ON PAGES M01 AND M02
 STATE THAT THE HVAC SYSTEM SHALL COMPLY WITH FBC EC 5TH
 EDITION ENERGY. THIS NEEDS TO BE CORRECTED TO THE FBC
 EC 6TH EDITION.
 2. FBC M 504.10 (11), THE DRYER EXHAUST DUCT NOTE
 INDICATES AN EXHAUST CAP WITH GRAVITY DAMPER AND INSECT
 SCREEN. ITEM #11 OF FBC M 504.10 STATES THAT SCREENS
 SHALL NOT BE INSTALLED AT THE TERMINATION. ALSO PLEASE
 SHOW LOCATION OF THE DRYER EXHAUST TERMINATION AT THE
 UTILITY ROOM.
 3. FBC M 307.1, THE PLANS NEED TO INDICATE THE LOCATION
 OF CONDENSATE LINES AND TERMINATION.
 4. FBC M 301.15, PROVIDE ENGINEERING FOR
 TIE-DOWNS/CONNECTIONS OF THE EXTERIOR CONDENSATE LINES.
 5. FBC B 107.2.1 THE CONDENSING UNIT FOR A/C #1 IS A 15
 SEER, THIS DOES NOT MEET THE ARCHITECT'S REQUIREMENT
 FOUND ON PAGE A-00 UNDER ENERGY CODE COMPLIANCE NOTE
 #14 WHICH CALLS FOR ALL A/C EQUIPMENT TO MEET A MINIMUM
 OF 16 SEER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-01-16 Cont ID  
Sent By lcrespo Date 2020-01-16 Time 07:04 Rev Time 0.00
Received By lcrespo Date 2020-01-16 Time 07:06 Sent To  
Notes
2020-01-16 07:05:3201/16/20 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2020-06-03 Cont ID  
Sent By pvalenti Date 2020-06-03 Time 15:28 Rev Time 0.00
Received By pvalenti Date 2020-06-03 Time 15:26 Sent To  
Notes
2020-06-03 15:28:18PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 A ROOFING PERMIT WITH ALL PRODUCT APPROVALS IS REQUIRED
 PRIOR TO ROOF WORK.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-02-03 Cont ID  
Sent By pvalenti Date 2020-02-03 Time 08:05 Rev Time 0.00
Received By pvalenti Date 2020-02-03 Time 06:48 Sent To  
Notes
2020-02-03 08:09:21***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ROOFING REVIEW DENIED:
  
 FBC B 107, A ROOFING SUB-PERMIT IS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-01-30 Cont ID  
Sent By fmittner Date 2020-01-30 Time 16:09 Rev Time 0.00
Received By fmittner Date 2020-01-30 Time 16:09 Sent To  
Notes
***NONE***