Plan Review Details - Permit 20010398
Plan Review Stops For Permit 20010398
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By pvalenti Date 2020-04-29 Time 10:51 Rev Time 0.00
Received By pvalenti Date 2020-04-28 Time 16:17 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-02-06 Cont ID  
Sent By rmcphers Date 2020-02-06 Time 13:24 Rev Time 0.00
Received By rmcphers Date 2020-02-06 Time 13:24 Sent To  
Notes
2020-02-06 13:30:33EMAIL SENT TO PERMIT LIBRARY
2020-02-06 13:27:39NEED A LETTER FROM THE CONTRACTOR STATING THAT THE ON
 LINE REQUIREMENTS FROM PALM BEACH COUNTY FOR ASBESTOS
 WILL BE COMPLIED WITH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-04-29 Cont ID  
Sent By pvalenti Date 2020-04-29 Time 10:50 Rev Time 0.00
Received By pvalenti Date 2020-04-28 Time 16:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-07 Cont ID  
Sent By rmcphers Date 2020-02-06 Time 13:23 Rev Time 0.00
Received By dbattles Date 2020-02-06 Time 12:56 Sent To  
Notes
2020-02-07 08:28:02BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 20010398
 REVIEWED: FEBRUARY 7, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FAIRHOUSING ACT (MULTIFAMILY DWELLINGS BUILT AFTER
 MARCH 13, 1991)
  
 1) 109.3 FBC[AMENDED]PLEASE PROVIDE COPY OF PROPOSAL
 WITH CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT
 SHOWN ON PERMIT APPLICATION.
  
 2) 301.1 FBC[EXISTING] GENERAL. THE REPAIR, ALTERATION,
 CHANGE OF OCCUPANCY, ADDITION OR RELOCATION OF ALL
 EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE METHODS
 LISTED IN SECTIONS 301.1.1 THROUGH 301.1.3 AS SELECTED
 BY THE APPLICANT. SECTIONS 301.1.1 THROUGH 301.1.3
 SHALL NOT BE APPLIED IN COMBINATION WITH EACH OTHER.
 A) 301.1.1 FBC[EXISTING] PRESCRIPTIVE COMPLIANCE
 METHOD. REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF
 OCCUPANCY COMPLYING WITH CHAPTER 4 OF THIS CODE IN
 BUILDINGS COMPLYING WITH THE FLORIDA FIRE PREVENTION
 CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE
 PROVISIONS OF THIS CODE.
 B) 301.1.2 FBC[EXISTING] WORK AREA COMPLIANCE METHOD.
 REPAIRS, ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY
 AND RELOCATED BUILDINGS COMPLYING WITH THE APPLICABLE
 REQUIREMENTS OF CHAPTERS 5 THROUGH 13 OF THIS CODE
 SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS
 OF THIS CODE.
 C) 301.1.3 FBC[EXISTING] PERFORMANCE COMPLIANCE METHOD.
 REPAIRS, ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY
 AND RELOCATED BUILDINGS COMPLYING WITH CHAPTER 14 OF
 THIS CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE
 PROVISIONS OF THIS CODE.
 - WHICH METHOD IS BEING USED FOR COMPLIANCE?
 (PRESCRIPTIVE,WORK AREA OR PERFORMANCE)
  
 501 FBC[EXISTING]IF WORK AREA COMPLIANCE PLEASE STATE
 THE LEVEL OF ALTERATION FOR WORK BEING PERFORMED.
 A) LEVEL 1 ALTERARTION
 B) LEVEL 2 ALTERARTION
 C) LEVEL 3 ALTERARTION
 - PLEASE ADD LEVEL OF ALTERATION TO DESIGN DATA.
 -ADD NOTE THAT FLOORING IS UNDER SEPARATE PERMIT
  
 3) THIS BUILDING WOULD HAVE BEEN BUILT WITH FAIRHOUSING
 ACT STANDARDS.
 PLEASE ADD TO COVER SHEET WHICH SAFE HARBOR STANDARD IS
 USED FOR FAIRHOUSING.
  
 101.4.1 FBC[EXISTING]BUILDINGS NOT PREVIOUSLY OCCUPIED.
 A BUILDING OR PORTION OF A BUILDING THAT HAS NOT BEEN
 PREVIOUSLY OCCUPIED OR USED FOR ITS INTENDED PURPOSE IN
 ACCORDANCE WITH THE LAWS IN EXISTENCE AT THE TIME OF
 ITS COMPLETION SHALL BE PERMITTED TO COMPLY WITH THE
 PROVISIONS OF THE LAWS IN EXISTENCE AT THE TIME OF ITS
 ORIGINAL PERMIT UNLESS SUCH PERMIT HAS EXPIRED.
 SUBSEQUENT PERMITS SHALL COMPLY WITH THE FLORIDA
 BUILDING CODE, BUILDING OR FLORIDA BUILDING CODE,
 RESIDENTIAL, AS APPLICABLE, FOR NEW CONSTRUCTION.
  
 IN LOOKING AT UNDIMENSIONED PLANS IT APPEARS THAT CLEAR
 SPACE WILL BE PROVIDED.
 HOWEVER, PLEASE INDICATE WHAT UNITS ARE APPLICABLE TO
 FAIRHOUSING STANDARDS.
 ARE THERE ELEVATORS TO EACH FLOOR? IF YES THAN
 FAIRHOUSING APPLIES TO ALL UNITS.
 FOR THE UNITS WHERE FAIRHOUSING APPLIES INDICATE WHAT
 SPECIFICATION THE BATH IS, SHOW CLEAR FLOOR SAPCE AT
 KITCHEN AND BATHROOM FIXTURES.
  
 REQUIREMENT 7 - USABLE BATHROOMS.
 VERIFY THE NEW VANITY MEETS HEIGHT REQUIREMENTS. ADD
 DETAIL OF CABINET TO SHOW COMPLIANCE.
  
 4) R-2 UNITS ARE SUBJECT TO FIRE RATINGS AND IT SHOWS
 THAT PLUMBING AND ELECTRICAL IS BEING ALTERED IN THE
 KITCHEN SOFFITS.
 PLEASE STATE WHAT RATING IS REQUIRED AT CEILING AND
 PROVIDE TESTED ASSEMBLY THAT WILL BE USED TO MAINTAIN
 THAT RATING.
  
 420.3 FBC[B]HORIZONTAL SEPARATION. FLOOR ASSEMBLIES
 SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR
 ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME
 BUILDING AND FLOOR ASSEMBLIES SEPARATING DWELLING OR
 SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO
 THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS
 HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711.
  
 711.2.4.3 FBC[B]DWELLING UNITS AND SLEEPING UNITS.
 HORIZONTAL ASSEMBLIES SERVING AS DWELLING OR SLEEPING
 UNIT SEPARATIONS IN ACCORDANCE WITH SECTION 420.3 SHALL
 BE NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED
 CONSTRUCTION. EXCEPTION: HORIZONTAL ASSEMBLIES
 SEPARATING DWELLING UNITS AND SLEEPING UNITS SHALL BE
 NOT LESS THAN 1/2- HOUR FIRE-RESISTANCE-RATED
 CONSTRUCTION IN A BUILDING OF TYPE IIB, IIIB AND VB
 CONSTRUCTION, WHERE THE BUILDING IS EQUIPPED THROUGHOUT
 WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 SECTION 903.3.1.1.
  
 5) 711.2.4.3 FBC[B]PLEASE ADD NOTE ON COVER IF THE
 UNITS ARE SPRINKLED AND THE TYPE OF CONSTRUCTION AS
 WELL.
  
 6) 714 FBC[B]IF PENETRATIONS ARE ALTERED OR CREATED
 PLEASE PROVIDE TESTED ASSEMBLIES THAT SHOW COMPLIANCE
 WITH SECTION 714 PENETRATIONS.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
2020-01-15 11:02:30PLEASE SEE COST BREAKDOWN DOCUMENT AND COORDINATE WITH
 SAK. SEE ATTACHMENT. LEM

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-01-30 Cont ID  
Sent By jpearson Date 2020-01-30 Time 06:44 Rev Time 0.00
Received By jpearson Date 2020-01-21 Time 08:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-01-17 Cont ID  
Sent By pleduc Date 2020-01-17 Time   Rev Time 0.00
Received By pleduc Date 2020-01-17 Time 12:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-04-29 Cont ID  
Sent By pvalenti Date 2020-04-29 Time 10:51 Rev Time 0.00
Received By pvalenti Date 2020-04-16 Time 08:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-06 Cont ID  
Sent By rmcphers Date 2020-02-06 Time 13:29 Rev Time 0.00
Received By rmcphers Date 2020-01-15 Time 11:15 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-02-06 Cont ID  
Sent By rmcphers Date 2020-02-06 Time 13:28 Rev Time 0.00
Received By rmcphers Date 2020-02-06 Time 13:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2020-04-21 Cont ID  
Sent By medwards Date 2020-04-17 Time 12:43 Rev Time 0.00
Received By medwards Date 2020-04-21 Time 12:20 Sent To  
Notes
2020-04-21 12:20:15COST BREAKDOWN SHEET WAS REVISED TO SHOW NO MECHANICAL
 WORK AND RESUBMITTED. PROJECT IS N FOR MECHANICAL.
2020-04-17 12:47:25THE COST BREAKDOWN SHEET HAS MECHANICAL - $800.00 PER
 UNIT FOR A TOTAL COST OF $22,400.00. IF THERE IS NO
 MECHANICAL WORK BEING DONE IN THIS PROJECT THIS NEEDS
 TO BE CHANGED TO ALSO SAY NO MECHANICAL WORK IN THIS
 PROJECT. IF THERE IS WORK BEING DONE TO WARRANT THIS
 AMOUNT OF MONEY, PLEASE PROVIDE DETAIL DRAWINGS AS
 REQUESTED IN THE 1ST REVIEWERS' COMMENTS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-30 Cont ID  
Sent By ccole Date 2020-01-30 Time 07:53 Rev Time 0.00
Received By ccole Date 2020-01-29 Time 17:11 Sent To  
Notes
2020-01-30 07:55:341ST REVIEW FBC-2017 MECHANICAL
 PERMIT #20010398
 1/20/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MECHANICAL ALTERATION PLANS IF
 APPLICABLE TO THE PROPOSED PROJECT- SECTION 107.2.1
 WPB. OTHERWISE PLEASE LABEL "NO MECHANICAL WORK" ON THE
 COVER SHEET.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK ?VOID? OR ?OLD? ON THEM. PLEASE
 RETAIN THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS.
 THIS PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-04-23 Cont ID  
Sent By tklarge Date 2020-04-23 Time 10:35 Rev Time 0.00
Received By tklarge Date 2020-04-23 Time 09:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-23 Cont ID  
Sent By jesmith Date 2020-01-23 Time 10:56 Rev Time 0.00
Received By jesmith Date 2020-01-23 Time 09:25 Sent To  
Notes
2020-01-23 10:55:59CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 20010398 4470 PORTOFINO WAY
  
  
 PLUMBING COMMENTS: DENIED
  
 THE OVERALL VALUE SEEMS TO BE LOW. WPB AMENDMENTS TO
 THE FBC 109.3 BUILDING PERMITS VALUATIONS. IF IN THE
 OPINION OF THE BUILDING OFFICIAL, THE CLAIMED VALUATION
 OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED UNLESS THE APPLICANT CAN SHOW DETAILED, QUANTITY
 ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS (EXCLUDING
 LAND VALUE) TO MEET THE APPROVAL OF THE BUILDING
 OFFICIAL. FOR PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE
 TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL,
 INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND
 DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT;
 EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE
 CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET
 BY THE BUILDING OFFICIAL.
  
 PROVISO
 1. PER WPB FBC 110.1, CONCEALED WORK SHALL BE EXPOSED
 FOR INSPECTION BY THE PLUMBING INSPECTOR TO DETERMINE
 COMPLIANCE WITH THE FBC PLUMBING CODE. THIS INCLUDES
 NEW SOFFITS AND THE BATHTUB CONTROL VALVE WALL AND AT
 THE INSPECTOR?S DISCRETION IS NOT LIMITED TO THE SAME.
 ALL TESTS AS REQUIRED BY THE PLUMBING INSPECTOR SHALL
 BE PERFORMED.
 2. ALL WORK SHALL COMPLY WITH THE FBC PLUMBING AND PER
 CITY CODES ARE SUBJECT TO FIELD INSPECTOR?S APPROVAL.
 3. A PLUMBING PERMIT SHALL BE APPLIED FOR BY A LAWFULLY
 LICENSED/CERTIFIED PLUMBING CONTRACTOR.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 20010398 4470 PORTOFINO WAY
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-04-17 Cont ID  
Sent By medwards Date 2020-04-17 Time 12:50 Rev Time 0.00
Received By medwards Date   Time   Sent To  
Notes
2020-04-17 12:51:152ND CYCLE SIGNATURE REVIEW APPROVED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-02-06 Cont ID  
Sent By rmcphers Date 2020-02-06 Time 13:29 Rev Time 0.00
Received By rmcphers Date 2020-02-06 Time 13:29 Sent To  
Notes
***NONE***