| Plan Review Stops For Permit 20010335 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2020-02-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-10 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-02-10 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2020-02-10 09:43:09 | LETTER RECEIVED AND INSERTED INTO PLANS SUPPORTING | | | DOCUMENTS. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-03 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-31 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2020-02-03 14:14:58 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: HTTP://PALM | | | BEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICES/ENVIRONME | | | NTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-RENOVATION. | | | HTML. THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA | | | EMAIL TO [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT | | | LINE. | | | | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-02-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-10 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-02-10 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2020-02-10 09:43:51 | PROVISO: | | | SUBMITTAL FOR INTERIOR GLASSWORK TO BE PROVIDED TO | | | INSPECTOR PRIOR TO INSTALL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-03 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-31 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2020-02-03 14:12:25 | PROVISO: | | | SUBMITTAL FOR INTERIOR GLASSWORK TO BE PROVIDED TO | | | INSPECTOR PRIOR TO INSTALL. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-01-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-26 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-26 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-02-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-02-07 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-01-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-01-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-01-15 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2020-01-15 14:59:18 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 1 - THERE IS NO INDICATION OF COMPLIANCE | | | WITH THE FLORIDA FIRE PREVENTION CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH | | | INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A | | | APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 2) SHEET A 1 - THERE ARE PLAN SHEET INDICATORS OF FP 1, | | | FA 1 & FA 2; HOWEVER, THERE ARE NO CORRESPONDING PLAN | | | SHEET ATTACHED. | | | | | | PLEASE REVIEW AND CORRECT | | | | | | | | | 3) ALL SHEETS - THERE IS NO SUITE NUMBER INDICATED ON | | | ANY PLAN SHEET. | | | | | | PLEASE REVIEW AND CORRECT | | | | | | | | | | | | 4) SHEET A 6 - THERE IS NO INDICATION OF EXISTING LIFE | | | SAFETY SYSTEMS; FIRE SPRINKLER & FIRE ALARM. | | | | | | EXISITNG LIFE SAFETY SYSTEMS SHALL REMIAN FUNCTIONAL | | | AND ACTIVE THROUGHOUT DEMO AND CONSTRUCTION. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A | | | APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-02-29 |
Time |
03:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-02-24 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2020-02-27 08:43:51 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-02-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-02-27 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-05 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2020-02-24 15:49:53 | C12 | | 2020-02-06 16:35:34 | C12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-03 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-09 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2020-01-21 15:36:45 | ROUTED TO C12 | | 2020-01-10 13:20:18 | C12 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-02-03 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-01-31 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2020-02-03 11:00:20 | NO CHANGE IN OCCUPANCY AND NO CHANGE IN SQ. FOOTAGE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-01-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-14 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-13 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-02-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-02-29 |
Time |
03:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-02-29 |
Time |
02:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-02-19 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-02-19 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2020-02-19 16:03:12 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1) A HOT WATER RECIRCULATION LINE IS REQUIRED PER 2017 | | | FBC-PLUMBING SEC.607.2. | | | 2) SHOW THE RECIRCULATION LINE ON THE WATER RISER. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 3) THE RECIRCULATION PUMP DOES NOT COMPLY WITH FBC PL | | | 607.2.1.2 ON A SYSTEM THAT USE THE COLD WATER PIPING TO | | | RETURN BACK TO THE WATER HEATER SHALL HAVE A SENSOR | | | THAT STARTS THE PUMP. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-01-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-01-15 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-01-15 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2020-01-15 11:10:10 | 1) SUBMIT AN ENLARGED FLOOR PLAN FOR TOILET ROOM #515 | | | (CEO) AND TOILET ROOM # 518. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 2) THE WALL NEXT TO THE WATER CLOSET IN TOILET ROOM # | | | 515 DOE NOT APPEAR TO BE LONG ENOUGH TO ACCEPT A 42 | | | INCH GRAB BAR. CLARIFY. | | | 3) IF THE SHOWER IN ROOM #515 IS A STANDARD ROLL IN | | | SHOWER, A 30 INCH WIDE MINIMUM BY 60 INCH LONG MINIMUM | | | CLEAR FLOOR SPACE SHALL BE PROVIDED ADJACENT TO THE | | | OPEN FACE OF THE SHOWER COMPARTMENT PER 2017 | | | FBC-ACCESS. SEC.608.2.2.1. CLARIFY. | | | 4) THE INSTALLATION OF THE GRAB BARS SHALL COMPLY WITH | | | 2017 FBC-ACCESS. SECS.604.5. SHOW COMPLIANCE ON | | | SHT.A-9.. | | | 5) THE MIRRORS IN THE ACCESSIBLE TOILET ROOMS SHALL | | | COMPLY WITH 2017 FBC-ACCESS. SEC.603.3 | | | 6) SHOW THE CLEAR FLOOR SPACE FOR THE WATER CLOSET IN | | | TOILET ROOM #515. COMPLY WITH 2017 FBC-ACCESS. | | | SEC.604.3.1. | | | 7) THE TOILET PAPER DISPENSER SHALL COMPLY WITH 2017 | | | FBC-ACCESS. SEC.604.7. | | | 8) TOILET ROOM #515 SHOWS THE DOOR OF THE CLOSET | | | SWINGING INTO THE CLEAR FLOOR SPACE FOR THE LAVATORY. | | | COMPLY WITH 2017 FBC-ACCESS. SEC.603.2.3. | | | 9) THE DISHWASHER SHALL BE EQUIPPED WITH A BACKFLOW | | | PREVENTER ON THE WATER LINE PER 2017 FBC-PLUMBING | | | SEC.608.2. | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS ON THE | | | BLODGETT OVEN.WPB AMEND. TO FBC SE. 107.1. | | | 11) A HOT WATER RECIRCULATION LINE IS REQUIRED PER 2017 | | | FBC-PLUMBING SEC.607.2. | | | 12) SHOW THE RECIRCULATION LINE ON THE WATER RISER. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2020-02-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2020-02-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-11 15:16:41 | * DOES NOT TRIGGER 50% THRESHOLD FOR LANDSCAPE | | | IMPROVEMENTS. | | | | | | *INTERIOR MODIFICATIONS FOR AN OFFICE USE ONLY. | | | | | | | | | REFERENCE: ORDINANCE NO. 2209-88 (SERVICO CENTRE | | | CONDOMINUM CPD) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-01-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2020-01-17 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2020-01-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-17 13:44:54 | * DOES NOT TRIGGER 50% THRESHOLD FOR LANDSCAPE | | | IMPROVEMENTS. | | | | | | REFERENCE: ORDINANCE NO. 2209-88 (SERVICO CENTRE | | | CONDOMINUM CPD) |
|
|