Plan Review Details - Permit 20010335
Plan Review Stops For Permit 20010335
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-02-10 Cont ID  
Sent By dbattles Date 2020-02-10 Time 09:39 Rev Time 0.00
Received By dbattles Date 2020-02-10 Time 09:39 Sent To  
Notes
2020-02-10 09:43:09LETTER RECEIVED AND INSERTED INTO PLANS SUPPORTING
 DOCUMENTS.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-02-03 Cont ID  
Sent By dbattles Date 2020-02-03 Time 14:15 Rev Time 0.00
Received By dbattles Date 2020-01-31 Time 15:07 Sent To  
Notes
2020-02-03 14:14:58PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: HTTP://PALM
 BEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICES/ENVIRONME
 NTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-RENOVATION.
 HTML. THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA
 EMAIL TO [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT
 LINE.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-10 Cont ID  
Sent By dbattles Date 2020-02-10 Time 09:43 Rev Time 0.00
Received By dbattles Date 2020-02-10 Time 09:43 Sent To  
Notes
2020-02-10 09:43:51PROVISO:
 SUBMITTAL FOR INTERIOR GLASSWORK TO BE PROVIDED TO
 INSPECTOR PRIOR TO INSTALL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-02-03 Cont ID  
Sent By dbattles Date 2020-02-03 Time 14:11 Rev Time 0.00
Received By dbattles Date 2020-01-31 Time 15:07 Sent To  
Notes
2020-02-03 14:12:25PROVISO:
 SUBMITTAL FOR INTERIOR GLASSWORK TO BE PROVIDED TO
 INSPECTOR PRIOR TO INSTALL.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-01-26 Cont ID  
Sent By jpearson Date 2020-01-26 Time 11:39 Rev Time 0.00
Received By jpearson Date 2020-01-26 Time 11:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-02-07 Cont ID  
Sent By pleduc Date 2020-02-07 Time   Rev Time 0.00
Received By pleduc Date 2020-02-07 Time 14:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-01-15 Cont ID  
Sent By pleduc Date 2020-01-15 Time   Rev Time 0.00
Received By pleduc Date 2020-01-15 Time 14:52 Sent To  
Notes
2020-01-15 14:59:18THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 1 - THERE IS NO INDICATION OF COMPLIANCE
 WITH THE FLORIDA FIRE PREVENTION CODE.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH
 INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A
 APPLICABLE NOTE OF ACKNOWLEDGEMENT.
  
  
  
 2) SHEET A 1 - THERE ARE PLAN SHEET INDICATORS OF FP 1,
 FA 1 & FA 2; HOWEVER, THERE ARE NO CORRESPONDING PLAN
 SHEET ATTACHED.
  
 PLEASE REVIEW AND CORRECT
  
  
 3) ALL SHEETS - THERE IS NO SUITE NUMBER INDICATED ON
 ANY PLAN SHEET.
  
 PLEASE REVIEW AND CORRECT
  
  
  
 4) SHEET A 6 - THERE IS NO INDICATION OF EXISTING LIFE
 SAFETY SYSTEMS; FIRE SPRINKLER & FIRE ALARM.
  
 EXISITNG LIFE SAFETY SYSTEMS SHALL REMIAN FUNCTIONAL
 AND ACTIVE THROUGHOUT DEMO AND CONSTRUCTION.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A
 APPLICABLE NOTE OF ACKNOWLEDGEMENT.
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-02-29 Cont ID  
Sent By tklarge Date 2020-02-29 Time 03:50 Rev Time 0.00
Received By tklarge Date 2020-02-24 Time 08:43 Sent To  
Notes
2020-02-27 08:43:51RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-27 Cont ID  
Sent By lmarchan Date 2020-02-27 Time 08:42 Rev Time 0.00
Received By lmarchan Date 2020-02-05 Time 16:35 Sent To  
Notes
2020-02-24 15:49:53C12
2020-02-06 16:35:34C12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-03 Cont ID  
Sent By dbattles Date 2020-02-03 Time 14:15 Rev Time 0.00
Received By dbattles Date 2020-01-09 Time 13:20 Sent To  
Notes
2020-01-21 15:36:45ROUTED TO C12
2020-01-10 13:20:18C12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-02-03 Cont ID  
Sent By dbattles Date 2020-02-03 Time 10:59 Rev Time 0.00
Received By dbattles Date 2020-01-31 Time 15:07 Sent To  
Notes
2020-02-03 11:00:20NO CHANGE IN OCCUPANCY AND NO CHANGE IN SQ. FOOTAGE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-01-14 Cont ID  
Sent By ccole Date 2020-01-14 Time 07:42 Rev Time 0.00
Received By ccole Date 2020-01-13 Time 17:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-02-29 Cont ID  
Sent By tklarge Date 2020-02-29 Time 03:50 Rev Time 0.00
Received By tklarge Date 2020-02-29 Time 02:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-02-19 Cont ID  
Sent By gjohnson Date 2020-02-19 Time 16:01 Rev Time 0.00
Received By gjohnson Date 2020-02-19 Time 16:01 Sent To  
Notes
2020-02-19 16:03:122ND REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1) A HOT WATER RECIRCULATION LINE IS REQUIRED PER 2017
 FBC-PLUMBING SEC.607.2.
 2) SHOW THE RECIRCULATION LINE ON THE WATER RISER. WPB
 AMEND. TO FBC SEC. 107.2.1.
 3) THE RECIRCULATION PUMP DOES NOT COMPLY WITH FBC PL
 607.2.1.2 ON A SYSTEM THAT USE THE COLD WATER PIPING TO
 RETURN BACK TO THE WATER HEATER SHALL HAVE A SENSOR
 THAT STARTS THE PUMP.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-15 Cont ID  
Sent By tklarge Date 2020-01-15 Time 11:50 Rev Time 0.00
Received By tklarge Date 2020-01-15 Time 06:17 Sent To  
Notes
2020-01-15 11:10:101) SUBMIT AN ENLARGED FLOOR PLAN FOR TOILET ROOM #515
 (CEO) AND TOILET ROOM # 518. WPB AMEND. TO FBC SEC.
 107.2.1.
 2) THE WALL NEXT TO THE WATER CLOSET IN TOILET ROOM #
 515 DOE NOT APPEAR TO BE LONG ENOUGH TO ACCEPT A 42
 INCH GRAB BAR. CLARIFY.
 3) IF THE SHOWER IN ROOM #515 IS A STANDARD ROLL IN
 SHOWER, A 30 INCH WIDE MINIMUM BY 60 INCH LONG MINIMUM
 CLEAR FLOOR SPACE SHALL BE PROVIDED ADJACENT TO THE
 OPEN FACE OF THE SHOWER COMPARTMENT PER 2017
 FBC-ACCESS. SEC.608.2.2.1. CLARIFY.
 4) THE INSTALLATION OF THE GRAB BARS SHALL COMPLY WITH
 2017 FBC-ACCESS. SECS.604.5. SHOW COMPLIANCE ON
 SHT.A-9..
 5) THE MIRRORS IN THE ACCESSIBLE TOILET ROOMS SHALL
 COMPLY WITH 2017 FBC-ACCESS. SEC.603.3
 6) SHOW THE CLEAR FLOOR SPACE FOR THE WATER CLOSET IN
 TOILET ROOM #515. COMPLY WITH 2017 FBC-ACCESS.
 SEC.604.3.1.
 7) THE TOILET PAPER DISPENSER SHALL COMPLY WITH 2017
 FBC-ACCESS. SEC.604.7.
 8) TOILET ROOM #515 SHOWS THE DOOR OF THE CLOSET
 SWINGING INTO THE CLEAR FLOOR SPACE FOR THE LAVATORY.
 COMPLY WITH 2017 FBC-ACCESS. SEC.603.2.3.
 9) THE DISHWASHER SHALL BE EQUIPPED WITH A BACKFLOW
 PREVENTER ON THE WATER LINE PER 2017 FBC-PLUMBING
 SEC.608.2.
 10) SUBMIT MANUFACTURER'S SPECIFICATIONS ON THE
 BLODGETT OVEN.WPB AMEND. TO FBC SE. 107.1.
 11) A HOT WATER RECIRCULATION LINE IS REQUIRED PER 2017
 FBC-PLUMBING SEC.607.2.
 12) SHOW THE RECIRCULATION LINE ON THE WATER RISER. WPB
 AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-02-11 Cont ID  
Sent By llouie Date 2020-02-11 Time   Rev Time 0.00
Received By llouie Date 2020-02-11 Time   Sent To  
Notes
2020-02-11 15:16:41* DOES NOT TRIGGER 50% THRESHOLD FOR LANDSCAPE
 IMPROVEMENTS.
  
 *INTERIOR MODIFICATIONS FOR AN OFFICE USE ONLY.
  
  
 REFERENCE: ORDINANCE NO. 2209-88 (SERVICO CENTRE
 CONDOMINUM CPD)
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-01-17 Cont ID  
Sent By llouie Date 2020-01-17 Time   Rev Time  
Received By llouie Date 2020-01-17 Time   Sent To  
Notes
2020-01-17 13:44:54* DOES NOT TRIGGER 50% THRESHOLD FOR LANDSCAPE
 IMPROVEMENTS.
  
 REFERENCE: ORDINANCE NO. 2209-88 (SERVICO CENTRE
 CONDOMINUM CPD)