| Plan Review Stops For Permit 20010152 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2020-03-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-03-20 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-03-19 |
Time |
18:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-01-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-30 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-30 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2020-01-30 08:27:31 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE ADDRESS, PERMIT NUMBER AND ASBESTOS IN THE SUBJECT | | | LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-03-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-03-20 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-03-19 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2020-03-20 17:20:36 | PROVISO: | | | 1-SEPARATE FIRE SPRINKLERS AND FIRE ALARM PERMITS | | | REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-29 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-29 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2020-01-29 18:58:56 | RESIDENTIAL (R2) ALTERATION BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 1- THIS IS TYPE I CONSTRUCTION FIRE SPRINKLERED | | | BUILDING. THE SCOPE OF WORK INCLUDES THE REMOVAL OF | | | WALLS AND CEILINGS. NEW DROPPED CEILINGS ARE PROPOSED. | | | PLANS DON'T PROVIDE ANY INFORMATION HOW THE PROPOSED | | | WORK WILL AFFECT THE EXISTING FIRE SPRINKLER SYSTEM. | | | PROVIDE SCHEMATIC LAYOUT SHOWING HOW THE FIRE SPRINKLER | | | SYSTEM WILL BE AFFECTED. SEC. 801.3 FBC-EXISTING | | | BUILDING. SEC. 107.3.5.1.1 CITY AMENDMENTS. | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR FIRE SPRINKLERS | | | AND FIRE ALARMS. | | | | | | 2- PLANS SUBMITTED SEEM TO HAVE A COPY OF THE | | | ARCHITECT'S SIGNATURE. ALL PLANS NEED TO BE PERSONALLY | | | SIGNED BY THE ARCHITECT OF RECORD (NO COPIES) AS | | | REQUIRED BY 61G1-16.003 FLORIDA ADMINISTRATIVE CODE | | | WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. | | | ARCHITECT TO PROVIDE SIGNATURE AND DATE ON ALL | | | DRAWINGS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY.(NOTE: SUBMIT OLD DRAWINGS FOR REFERENCE) A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-26 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-26 |
Time |
14:02 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-01-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-29 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-29 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2020-01-29 15:18:33 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC EX 607.1.1 | | | OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 2. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | | KITCHEN REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. | | | NEC 210.8 | | | 3. ALL RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS | | | SHALL HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9) | | | 4. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION OR NOTE | | | FOR COMPLIANCE. NEC 410.10(D) | | | 5. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | | CORRECTION OR NOTE FOR COMPLIANCE. NEC 410.16 | | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12 | | | 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC 210.8(D) | | | 8. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. LOAD CALCULATION PROVIDED DOES NOT | | | USE 208 AS THE VOLTAGE FOR AMPERAGE DEMAND. NEC 215.2, | | | 220, 408.30 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-03-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-03-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-03-06 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-01-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-01-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-01-15 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2020-01-15 14:42:02 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEETS A 001 & 002 - THERE IS NO INDICATIONS OF | | | COMPLAINCE WITH THE FLORIDA FIRE PREVENTION CODE. | | | | | | THE PROPOSED SHALL COMPLY WITH THE APPLICABLE CODES OF | | | THE 6THE EDITION OF THE FLORIDA FIRE PREVENTION CODE | | | WHICH INCLUDER THE 2015 EDITIONA OF NFPA 1 & 101. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A | | | APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 2) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED | | | CONTRACTORS FOR CODE COVERAGE COMPLIANCE. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS | | | AND SHOP DRAWINGS. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A | | | APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR | | | FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE | | | THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AND PROVIDE A | | | APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-03-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-03-03 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-01-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-07 |
Time |
13:02 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2020-01-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-29 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-29 |
Time |
18:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-04-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-03-23 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-03-23 |
Time |
11:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-16 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-16 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2020-01-16 08:32:19 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #20010152 | | | 1/16/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED. PLEASE | | | CLARIFY IF ANY ALTERATIONS TO THE EXISTING HVAC SYSTEMS | | | ARE PROPOSED SUCH AS KITCHEN AND BATH EXHAUST SYSTEMS, | | | AC SYSTEM REPLACEMENTS, OR DUCT ALTERATIONS- SECTION | | | 107.2.1 WPB. PLEASE NOTE THAT MECHANICAL EXHAUST IS | | | REQUIRED FOR THE BATHS AT AN INTERMITTENT RATE OF 50 | | | CFMS, AND FOR THE KITCHENS AT AN INTERMITTENT RATE OF | | | 100 CFMS- TABLE 403.3.1.1 FBC M. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL NEW | | | COOKING APPLIANCES AND KITCHEN HOODS- SECTIONS 505 AND | | | 917.2 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-03-19 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2020-03-19 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2020-03-19 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-01-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-01-14 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-01-14 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2020-01-14 09:50:24 | 1) THE VALVES TO THE STACKED WASHER AND DRYER SHALL BE | | | ACCESSIBLE. 2017 FBC- PLUMBING SEC. 606. | | | 2) SHT. A3.01 - DETAIL # 7 - THE SHOWER FLOOR SHALL BE | | | PITCHED A MINIMUM OF 1/4 INCH PER FOOT TO THE DRAIN. | | | 2017 FBC-PLUMBING SEC. | | | | | | REVIEW NOT COMPLETE. | | | | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|