| 2020-01-16 14:43:39 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | NFPA 54 = NATIONAL FUEL GAS CODE |
| | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE |
| | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE |
| | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 |
| | NFPA 99 = HEALTH CARE FACILITIES CODE |
| | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | |
| | 20010149 REVISION TO MASTER 18090722 |
| | |
| | 1ST REVIEW |
| | GAS COMMENTS: DENIED |
| | |
| | 1.REFER TO GAS RISER DIAGRAM SUBMITTED BY APPLICANT; |
| | A.THE GAS SYSTEM WAS INITIALLY SUBMITTED IN 18090722 |
| | PERMIT DOCUMENT PLAN SHEET S-9 WITH THE LONGEST RUN |
| | BEING 46 FEET. THE LONGEST RUN IS NOW STATED TO BE 80 |
| | FEET. AS SUCH THE CSST EHD 19 TUBING BETWEEN THE |
| | TANKLESS WATER HEATER AND THE DRYER IS NOW UNDERSIZED. |
| | RESIZE BASED ON THE 80 FEET. |
| | B.THE RISER DIAGRAM IS UNCLEAR AS TO THE ROUTING OF THE |
| | HORIZONTAL DISTRIBUTION IN SIDE THE RESIDENCE. PLEASE |
| | CONFIRM ON THE DRAWING THAT IT IS ROUTED IN THE CRAWL |
| | SPACE AS IS INDICATED ON THE 18090722 PERMIT DOCUMENTS |
| | AND SHOW THE CORRECT LENGTH OF THE VERTICAL PORTION OF |
| | THE DRYER BRANCH AS THE DRYER ITSELF IS LOCATED ON THE |
| | SECOND FLOOR. |
| | C.CONCERNING THE ADDED RUN TO THE ADDED POOL HEATER, |
| | PROVIDE CUT LENGTHS OF GALVANIZED PIPING AT THE POOL |
| | HEATER, FROM THE METER TO THE TEE AT THE BRANCH TO THE |
| | POOL HEATER AND FROM THE TEE TO THE PE PIPING. PLEASE |
| | NOTE THAT YOU HAVE INDICATED 80 FEET OF UNDERGROUND PE |
| | TO THE POOL HEATER. IF THE 80 FEET STILL STANDS THEN |
| | YOU HAVE EXCEEDED THE 80 FEET LONGEST RUN AND SHALL |
| | CALCULATE BASED ON THE CORRECT MAXIMUM LENGTH. THIS |
| | APPLIES TO THE HOUSE INTERIOR PIPING AS WELL. |
| | D.TOTAL BTU IS STATED AS 729,000. I CALCULATE 729,200. |
| | PER WPB FBC 107.2.1, CLARIFY. |
| | E.PROVIDE PROJECT ADDRESS ON RISER DIAGRAM |
| | |
| | 2.PER WPB FBC 107.2.1, PROVIDE ACCURATE TECHNICAL |
| | DATA/SPECIFICATION FOR POOL HEATER INDICATING ACTUAL |
| | MODEL NUMBER, BTUS, TYPE OF GAS APPLICATION, DIMENSIONS |
| | AQND MANUFACTURER?S INSTALLATION RECOMMENDATIONS. ALL |
| | INFORMATION SHALL BE CLEARLY LEGIBLE. |
| | |
| | 3. REGARDING THE RESUBMITTAL, PROVIDE RISER DIAGRAM AND |
| | CALCULATIONS ON A LARGE ENOUGH SHEET OF PAPER TO |
| | ACCOMMODATE THE FOLLOWING PROVISOS |
| | A.REFER TO PERMIT 18090722 DOCUMENTS PLAN SHEET S-1. |
| | RECORD DRAWING SHALL BE PROVIDED DEPICTING ACTUAL |
| | MATERIAL, ROUTING AND SIZING OF GAS PIPE BENEATH THE |
| | CRAWL SPACES AND SHALL INCLUDE BRANCH TO DRYER ON |
| | SECOND FLOOR. DRAWING SHALL BE SUBMITTED, APPROVED AND |
| | ON SITE PRIOR TO FINAL INSPECTION. |
| | B.REFER TO PERMIT 18090722 DOCUMENTS PLAN SHEET S-9. |
| | RECORD DRAWING SHALL BE PROVIDED WITH VREVISED GAS |
| | RISER DIAGRAM TO INCLUDE GAS PIPING TO THE ADDED POOL |
| | HEATER AND ACCURATELY REFLECT THE BRANCH TO DRYER ON |
| | SECOND FLOOR WITH CORRECT VERTICAL LENGTH. DRAWING |
| | SHALL BE SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL |
| | INSPECTION. |
| | C.WPB FBC 107.2.1, RECORD SITE DRAWING SHALL BE |
| | PROVIDED DEPICTING ACTUAL MATERIAL, ROUTING AND SIZING |
| | OF GAS PIPE FROM REGULATOR/METER TO POOL HEATER. SHOW |
| | LOCATIONS OF METER AND POOL HEATER. DRAWING SHALL BE |
| | SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL |
| | INSPECTION. |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |
| | 20010149 REV TO MASTER 18090722 |
| | |
| | 134 GREYNOR DR |
| | |
| | |
| | |
| | |