Plan Review Details - Permit 20010046
Plan Review Stops For Permit 20010046
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2020-02-22 Cont ID  
Sent By pvalenti Date 2020-02-22 Time 12:21 Rev Time 0.00
Received By pvalenti Date 2020-02-22 Time 12:20 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-02-11 Cont ID  
Sent By jwitmer Date 2020-02-11 Time 11:40 Rev Time 0.00
Received By jwitmer Date 2020-02-11 Time 11:31 Sent To  
Notes
2020-02-11 11:40:35ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
 19120504
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-03-16 Cont ID  
Sent By jwitmer Date 2020-03-16 Time 10:36 Rev Time 0.00
Received By jwitmer Date 2020-03-16 Time 10:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-02-11 Cont ID  
Sent By jwitmer Date 2020-02-11 Time 13:08 Rev Time 0.00
Received By jwitmer Date 2020-02-11 Time 11:31 Sent To  
Notes
2020-02-11 13:09:162017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20010046
 ADD: 1880 PALM BEACH LAKES BLVD.
 CONT: TBD/ TO BE DETERMINED
 TEL: ???????
 E-MAIL: [email protected] CONTACT: ASHLEY ROSADO
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. FEB. 11/2020
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET LS1 DID NOT PROVIDE TO WHICH
 RACK STORAGE UNITS WERE TO BE EXTENDED, IT IS NOT CLEAR
 IF CERTAIN RACKS ARE TO BE EXTENDED, OR ALL RACKS ARE
 TO BE EXTENDED. 107.2.1.2 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 2) THE COVERSHEET/ INDEX NOR THE LIFE SAFETY SHEET
 PROVIDE ANY HELP IN DETERMINING IF THERE IS TO BE
 ADDITIONAL FIRE SPRINKLER WORK TO BE COMPLETED SINCE
 SHEET F-4 FIXTURE EXTENSION PLAN SHOWS THE RACK STORAGE
 UNITS EXTENDING TO THE BOTTOM CHORD OF THE BAR JOIST.
 THE FLORIDA FIRE PREVENTION CODE ADDRESSES HIGH PILED
 STORAGE FOR IN MERCANTILE OCCUPANCIES. 2017 FBC-B
 SECTION 903.2.7.1.
  
 3) SHEET F-4 FIXTURE EXTENSION PLAN NOTE # 3 INDICATES
 ALL FIXTURE EXTENSIONS TO BE SUSPENDED FROM THE CEILING
 USING UNISTRUCT PER FIXTURE EXTENSION ATTACHMENT
 DETAILS OR INDICATED OTHERWISE BY THE STRUCTURAL
 ENGINEER. THIS STATEMENT STATES THE FIXTURE EXTENSION
 IS TO BE HUNG FROM THE CEILING. THE DETAIL ON THE
 FIXTURE PLAN SHOWS UNISTRUCT BEING HUNG FROM THE BOTTOM
 CHORD OF THE BAR JOIST. IS THE INTENT FOR THE FUTURE
 EXTENSION TO BE SUSPENDED FROM THE BAR JOIST? HAS A
 STRUCTURAL ENGINEER BEEN BROUGHT IN FOR THE ADDITIONAL
 LOADING TO THE BAR JOIST. IF THE EXTENSIONS ARE TRULY
 BEING HUNG FROM THE BAR JOIST WHAT ADDITIONAL LOADING
 DEAD LOADS AND LIVE LOADS ARE BEING ADDED? OR ARE THE
 FIXTURE EXTENSIONS TRANSFERRING THE LOADS DOWN THE LEGS
 TO THE FLOOR? AGAIN HAS THE ADDITIONAL LOADING ON THE
 RACK STORAGE UNITS DEAD & LIVE LOADS BEEN CALCULATED
 FOR THE RACK STORAGE UNITS? OR ARE THE VERTICAL FIXTURE
 EXTENSIONS USING THE UNISTRUCT BEING BOLTED TO THE BAR
 JOIST JUST FOR STABILIZING? 107. 2.1.2 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-02-12 Cont ID  
Sent By jleahy Date 2020-02-12 Time 15:46 Rev Time 0.00
Received By jleahy Date 2020-02-12 Time 15:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-03-10 Cont ID  
Sent By sathomas Date 2020-03-10 Time 00:00 Rev Time 0.00
Received By sathomas Date 2020-03-10 Time 00:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-01-29 Cont ID  
Sent By sathomas Date 2020-01-29 Time 00:00 Rev Time 0.00
Received By sathomas Date 2020-01-29 Time 00:00 Sent To E
Notes
2020-01-29 11:08:32A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED
 AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON
 THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED DURING PLAN RESUBMISSION.
  
 SCOPE OF WORK COULD NOT BE DETERMINED. COVER PAGE
 REFERS SCOPE OF WORK TO PAGE A03. INFERRED PAGE IS NOT
 INCLUDED IN SUBMITTAL PACKET.
  
 PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND
 DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF
 NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
  
 S. THOMAS
 561-804-4728

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-03-16 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-28 Time 14:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-02-12 Cont ID  
Sent By jleahy Date 2020-02-12 Time 15:46 Rev Time 0.00
Received By jleahy Date 2020-01-09 Time 10:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-03-16 Cont ID  
Sent By jwitmer Date 2020-03-16 Time 10:38 Rev Time 0.00
Received By jwitmer Date 2020-03-16 Time   Sent To  
Notes
2020-03-16 10:37:502ND REVIEW A SHEETS AND CS SHEETS CHECKED FOR
 ELECTRONIC SIGNATURE (ARCHITECT). OK. JW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-02-12 Cont ID  
Sent By jleahy Date 2020-02-12 Time 15:46 Rev Time 0.00
Received By jleahy Date 2020-02-12 Time 15:46 Sent To  
Notes
***NONE***