| Plan Review Stops For Permit 20010044 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-03-16 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-03-16 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2021-03-16 11:28:02 | RES IRRIGATION NO LONGER NEEDS PLAN REVIEW PER SH/TKL | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-25 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-25 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-28 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-23 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-01-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-10 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-03 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-25 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-25 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2020-02-25 10:25:24 | PLUMBING COMMENTS: SYSTEMS APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-28 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-28 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-01-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-10 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-09 |
Time |
19:39 |
Sent To |
|
|
| Notes |
| 2020-01-10 09:03:19 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHTS. CL4-CL5 HAVE NOTES AT THE BOTTOM OF THE SHEETS | | | DRAWINGS ARE FOR COMMUNICATION PURPOSES ONLY IS THIS A | | | TYPE SHOULD READ FOR CONSTRUCTION PURPOSES ONLY PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 2. AN REDUCED PRESSURE PRINCIPLE ASSEMBLY OR RP IS | | | REQUIRED AT THE METER. PER WPB UTILITIES DEPARTMENT AND | | | WPB CROSS CONNECTION CONTROL MANUAL | | | | | | 3. PLACE NOTE ON PLAN SEPARATE PERMIT REQUIRED FOR RP | | | BACK FLOW DEVICE. PER WPB UTILITIES DEPARTMENT | | | | | | 4. IRRIGATION/SPRINKLER SYSTEMS AND RISERS FOR SPRAY | | | HEADS SHALL NOT BE INSTALLED WITHIN 1 FOOT OF THE | | | BUILDING SIDEWALL. PER FBC PL 318.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-25 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-02-25 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2021-03-11 14:16:07 | APPROVED BY T.LARGE | | 2020-02-25 10:29:42 | CODES IN EFFECT: | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | COMMENTS: DENIED | | | DIGITAL SIGNATURES ON SHEETS CL4 - CL5 ARE NOT | | | ACCEPTABLE. PER FS 471 AND FAC 61G15-23.003, A DIGITAL | | | PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD | | | PARTY VERIFICATION. SELF-CERTIFICATION IS NOT | | | ACCEPTABLE FOR ENGINEERS. PROVIDE CORRECTION PER WPB | | | FBC 107.1. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 20010044 245 GREYMON DR | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-28 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-28 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2020-01-28 17:17:02 | DIGITAL SIGNATURES ON SHEETS CL4 - CL5 IS MISSSINGR PER | | | A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE | | | PROPER THIRD PARTY VERIFICATION. SELF-CERTIFICATION IS | | | NOT ACCEPTABLE FOR ENGINEERS. ADDITIONALLY, THE DIGITAL | | | SIGNATURE MUST INCLUDE THE STATEMENT "SIGNED AND | | | SEALED" AS PER FAC 61G15-23.004. PROVIDE CORRECTION. | | | WPB FBC 107.1; FS 471/481 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-01-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2020-01-10 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2020-01-10 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2020-01-10 09:08:02 | DIGITAL SIGNATURES ON SHEETS CL4 - CL5 ARE SELF | | | CERTIFIED BY ENGINEER PER STATE STATUTE THEY SHALL BE | | | THIRD PARTY CERTIFIED. |
|
|