| Plan Review Stops For Permit 19121111 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-29 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-29 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-09-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-05 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-05 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-07-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-09 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-07 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2020-07-09 14:07:01 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC B 107, PLEASE PROVIDE THE WIND LOAD INFORMATION ON | | | PLAN PER THE FLORIDA BUILDING CODE CHAPTER 16. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-10 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-10 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2020-06-10 10:54:14 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107, PLEASE PROVIDE ENGINEER'S SIGNED AND SEALED | | | DETAILS FOR FOUNDATION AND WIND LOAD CALCULATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-29 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-29 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-24 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2020-07-24 10:40:28 | STILL NEEDS ZONING APPROVAL JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-01-03 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-01-03 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2020-01-03 10:52:11 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) VLAUE FOR THE WORK SHOWN IS TOO LOW, PLEASE SUBMIT A | | | SIGNED CONTRACT WITH THE OWNER. | | | | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2) SHOWS TWO (2) CIRCUITS MAINS CANNOT BE SMALLER THEN | | | 30A. 230.79(B) (B) TWO-CIRCUIT INSTALLATIONS. FOR | | | INSTALLATIONS CONSISTING OF NOT MORE THAN TWO 2-WIRE | | | BRANCH CIRCUITS, THE SERVICE DISCONNECTING MEANS SHALL | | | HAVE A RATING OF NOT LESS THAN 30 AMPERES. | | | | | | 3) NEED THE AVAILABLE FAULT CURRENT RATING FOR THE | | | SERVICE. 110.10 , 110.24 AVAILABLE FAULT CURRENT ( A) | | | FIELD MARKING. SERVICE EQUIPMENT IN OTHER THAN DWELLING | | | UNITS SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE | | | MAXIMUM AVAILABLE FAULT CURRENT. THE FIELD MARKING(S) | | | SHALL INCLUDE THE DATE THE FAULT-CURRENT CALCULATION | | | WAS PERFORMED AND BE OF SUFFICIENT DURABILITY TO | | | WITHSTAND THE ENVIRONMENT INVOLVED. | | | | | | 4) PANEL BOARD NEEDS TO BE LISTED 110.3, 230.66 MARKING | | | SERVICE EQUIPMENT RATED AT 1000 VOLTS OR LESS SHALL BE | | | MARKED TO IDENTIFY IT AS BEING SUITABLE FOR USE AS | | | SERVICE EQUIPMENT. ALL SERVICE EQUIPMENT SHALL BE L | | | ISTED. INDIVIDUAL METER SOCKET ENCLOSURES SHALL NOT BE | | | CONSIDERED SERVICE EQUIPMENT. | | | | | | 5) CUT SHEETS FOR SURGE ARRESTOR 110.3 | | | | | | 6) 250.94 BONDING FOR OTHER SYSTEMS AN INTERSYSTEM | | | BONDING TERMINATION FOR CONNECTING INTERSYSTEM BONDING | | | CONDUCTORS REQUIRED FOR OTHER SYSTEMS SHALL BE PROVIDED | | | EXTERNAL TO ENCLOSURES AT THE SERVICE EQUIPMENT OR | | | METERING EQUIPMENT ENCLOSURE AND AT THE DISCONNECTING | | | MEANS FOR ANY ADDITIONAL BUILDINGS OR STRUCTURES. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-29 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-22 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-09-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-05 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-13 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-24 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-07 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-07-07 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-06-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-01-03 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-12-31 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2020-01-02 16:18:39 | ELEC <5K |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-09-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-29 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-29 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-05 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-05 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-07-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-07 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-07 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-06-10 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-06-10 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-06-10 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2020-06-10 10:54:53 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FBC B 107.2.1, FS 471, FS 481; PLEASE PROVIDE: | | | 1) VERIFIED DIGITAL SIGNATURES IN PROJECT DOX, | | | 2) VERIFIED DIGITALLY SIGNED DOCUMENTS EMAILED IN PDF?S | | | OR | | | 3) PAPER PLANS WITH ORIGINAL SIGNATURES AND SEALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-09-25 |
Time |
13:55 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-09-25 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-08-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-08-20 |
Time |
15:23 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-08-20 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2020-08-20 15:33:24 | FAILED | | | | | | 1) UPDATE PLANS TO REFLECT THE STEALTH POLE - EX RISER | | | DETAIL SHOWS EXTERIOR MOUNTED EQUIPMENT FOR THE OLD | | | POLE. | | | | | | 2) POLE DESIGN PASSES. | | | | | | 3) THE SURVEY UPLOADED WITH THIS PERMIT IS FOR YOUR | | | LOCATION IN THE 2500 BLOCK OF NORTH AUSTRALIAN AVENUE | | | (PERMIT 20030480). PLEASE UPLOAD THE SURVEY FOR THIS | | | LOCATION. | | | | | | 4) WHILE NO SURVEY WAN SUBMITTED, STAFF PERFORMED A | | | SITE VISIT AND THE PREVIOUSLY INSTALLED CONCRETE POLE | | | LOOKED LIKE IT WAS ON PRIVATE PROPERTY (THE PROPERTY | | | APPRAISOR MAPS INDICATED THIS AS WELL) EVEN THOUGH THE | | | ENGINEERING PLAN SUBMITTED WITH THE RIGHT-OF-WAY PERMIT | | | SHOWS THE RIGHT-OF-WAY LINE NOT AT THE BACK OF | | | SIDEWALK. YOU SHOULD HAVE THE SURVEYOR STAKE THE EDGE | | | OF THE RIGHT-OF-WAY LINE PRIOR TO INSTALLATION TO AVOID | | | AN INCORRECT PLACEMENT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-24 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2020-07-24 |
Time |
13:37 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-07-24 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2020-07-24 13:42:45 | FAILED | | | | | | 1) PROVIDE A PROVIDE A SURVEY, PREPARED BY A FLORIDA | | | LICENSED SURVEYOR, WHICH SHOWS THE POLE LOCATION AND | | | THE RIGHT-OF-WAY LINE SO THAT STAFF CAN VERIFY THAT THE | | | WIRELESS COMMUNICATION FACILITY IS WITHIN THE | | | RIGHT-OF-WAY AND NOT ON PRIVATE PROPERTY. STAFF HAS | | | VISITED THIS SITE AND THE POLE APPEARS TO BE INSTALLED | | | ON PRIVATE PROPERTY. | | | | | | 2) PROVIDE A COPY OF THE FDOT APPROVAL IF THE SURVEY | | | SHOWS THE PROPOSED WIRELESS COMMUNICATION FACILITY IN | | | THE RIGHT-OF-WAY. | | | | | | 3) THE PROPOSED WIRELESS FACILITY (POLE) DOES NOT MEET | | | THE CITY OF WEST PALM BEACH CONCEALMENT (STEALTH), | | | STYLE OR HEIGHT REQUIREMENTS LISTED IN SECTIONS | | | 78-411(E), 78-411(F) AND 78-411(G) OF THE CITY CODE. | | | PROVIDE A POLE THAT MEETS THE CITY CODE REQUIREMENTS. | | | NOTE: AT&T HAS SHOWN POLES ON OTHER APPLICATIONS THAT | | | MEET THE CITY CODE REQUIREMENTS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|