Plan Review Details - Permit 19121054
| Plan Review Stops For Permit 19121054 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-01-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-01-03 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-12-30 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-12-30 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2019-12-30 08:56:49 | | | | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | THE SUBMITTED FLAME SPREAD TEST REPORT (ASTM E?84) WAS | | | TESTED AND APPROVED FOR WOOD FLOORING. | | | | | | PLEASE PROVIDE THE APPROVED (ASTM E?84) TEST REPORT AND | | | RESULTS FOR USING ECO?ULTIMATE SILENCER UNDERLAYMENT | | | WITH LAMINATE FLOORING OR SUBMIT A DIFFERENT PRODUCT | | | THAT HAS BEEN TESTED AND APPROVED WITH LAMINATE | | | FLOORING SUCH AS PROFLEX LV200. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-01-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-01-02 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2020-01-03 11:20:14 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-12-30 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-12-27 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2019-12-27 16:09:42 | BLDG <5K |
|
|
|