Plan Review Details - Permit 19120988
Plan Review Stops For Permit 19120988
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2020-04-24 Cont ID  
Sent By CTHROOP Date 2020-04-24 Time 16:52 Rev Time 0.00
Received By cthroop Date 2020-04-24 Time 16:52 Sent To  
Notes
2020-04-24 16:53:00SEE NFIP REVIEW. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2020-03-17 Cont ID  
Sent By cthroop Date 2020-03-17 Time 08:04 Rev Time 0.00
Received By cthroop Date 2020-03-16 Time 16:27 Sent To  
Notes
2020-03-17 08:05:34CHANGE BUILDING REVIEW TO NFIP REVIEW. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-03 Cont ID  
Sent By cthroop Date 2020-03-03 Time 11:10 Rev Time 0.00
Received By cthroop Date 2020-03-03 Time 10:06 Sent To  
Notes
2020-03-17 08:06:18SEE NFIP REVIEW. CT
2020-03-03 11:17:45PLAN REVIEW - NFIP ELEVATION CERTIFICATE
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS FROM 1ST REVIEW HAVE NOT BEEN
 ADDRESSED:
  
  
 ELEVATION CERTIFICATE REVIEW:
  
 1) A7 VERIFY THAT THIS IS 1A AS ENTERED BECAUSE THE
 PLANS SHOW STEM WALL CONSTRUCTION AND THAT FITS BETTER
 WITH DIAGRAM 1B.
  
 2) A9(B) PLEASE ENTER NUMBER OF FLOOD OPENINGS IN
 ATTACHED GARAGE. (PLANS SHOW 4)
  
 3) A9(C) ENTER NET AREA OF OPENINGS.PLANS SAY MODEL
 1540-520. PRODUCT APPROVAL FL58822-R3 SHOWS MODEL
 1540-520 AT .53 SQ. FT. PER VENT.
  
 4) A9(D) THESE ARE ENGINEERED OPENINGS USING ENGINEERED
 PRODUCT UNDER PRODUCT APPROVAL FL58822-R3
  
 5) PLEASE STATE IN COMMENTS WHAT VERTICAL DATUM WAS
 UTILIZED FOR A5.
  
 NEW COMMENT:
  
 UPON SUBMITTAL OF FINISHED CONSTRUCTION ELEVATION
 CERTIFICATE, PROVIDE THE FOLLOWING INFORMATION:
  
 6) C2 (E) LOWEST ELEVATION OF MACHINERY OR EQUIPMENT
 SERVICING THE BUILDING SHALL BE AT OR ABOVE DFE OF 9.0
 FEET NAVD
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-24 Cont ID  
Sent By dbattles Date 2019-12-24 Time 10:09 Rev Time 0.00
Received By dbattles Date 2019-12-24 Time 10:09 Sent To  
Notes
2019-12-24 10:09:49BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19120988
 REVIEWED: DECEMBER 24, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[R] = FBC RESIDENTIAL
  
 ELEVATION CERTIFICATE REVIEW:
  
 1) A7 VERIFY THAT THIS IS 1A AS ENTERED BECAUSE THE
 PLANS SHOW STEM WALL CONSTRUCTION AND THAT FITS BETTER
 WITH DIAGRAM 1B.
  
 2) A9(B) PLEASE ENTER NUMBER OF FLOOD OPENINGS IN
 ATTACHED GARAGE. (PLANS SHOW 4)
  
 3) A9(C) ENTER NET AREA OF OPENINGS.PLANS SAY MODEL
 1540-520. PRODUCT APPROVAL FL58822-R3 SHOWS MODEL
 1540-520 AT .53 SQ. FT. PER VENT.
  
 4) A9(D) THESE ARE ENGINEERED OPENINGS USING ENGINEERED
 PRODUCT UNDER PRODUCT APPROVAL FL58822-R3
  
 5) PLEASE STATE IN COMMENTS WHAT VERTICAL DATUM WAS
 UTILIZED FOR A5.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2020-05-04 Cont ID  
Sent By cthroop Date 2020-05-04 Time 14:05 Rev Time 0.00
Received By cthroop Date 2020-05-04 Time 13:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-05-01 Cont ID  
Sent By cthroop Date 2020-05-01 Time 11:54 Rev Time 0.00
Received By cthroop Date 2020-05-01 Time 10:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-04-27 Cont ID  
Sent By cthroop Date 2020-04-27 Time 15:00 Rev Time 0.00
Received By cthroop Date 2020-04-24 Time 11:44 Sent To  
Notes
2020-04-24 11:45:15PER SAMANTHA. CONVERTED TO DIGITAL TO HAVE RECORD OF
 NFIP REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-17 Cont ID  
Sent By cthroop Date 2020-03-17 Time 10:12 Rev Time 0.00
Received By cthroop Date 2020-03-06 Time 14:08 Sent To I
Notes
2020-03-09 14:09:08RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-03 Cont ID  
Sent By cthroop Date 2020-03-03 Time 11:17 Rev Time 0.00
Received By cthroop Date 2020-02-21 Time 10:33 Sent To  
Notes
2020-02-26 17:15:52TO CT DESK
  
2020-02-25 10:34:13RESUB ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-24 Cont ID  
Sent By dbattles Date 2019-12-24 Time 10:09 Rev Time 0.00
Received By dbattles Date 2019-12-24 Time 08:13 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status P Date 2020-05-04 Cont ID  
Sent By cthroop Date 2020-05-04 Time 14:05 Rev Time 0.00
Received By cthroop Date 2020-05-04 Time 13:58 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2020-05-01 Cont ID  
Sent By cthroop Date 2020-05-01 Time 11:49 Rev Time 0.00
Received By cthroop Date 2020-05-01 Time 08:29 Sent To  
Notes
2020-05-01 11:54:06PLAN REVIEW - NFIP FINISHED CONSTRUCTION ELEVATION
 CERTIFICATE
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER ? BUILDING - PX3169
 PLANS EXAMINER ? 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW - FINISHED CONSTRUCTION EC
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES.
 ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
  
  
 1. LINE A5 - LONGITUDE IS EXPRESSED AS EAST OR WEST NOT
 NORTH OR SOUTH. PLEASE CORRECT. CORRECTED
  
 2. SECTION C - C2 E) LOWEST ELEVATION OF MACHINERY OR
 EQUIPMENT SERVICING THE BUILDING IS SHOWN AS 8.4 FEET.
 THE LOWEST ELEVATION OF THIS EQUIPMENT SHALL BE AT OR
 ABOVE THE DESIGN FLOOD ELEVATION (DFE) OF 9.0 FEET
 NAVD. CORRECTED
  
 3. SECTION D - (PER FEMA ELEVATION CERTIFICATE
 INSTRUCTIONS, SECTION A - PROPERTY INFORMATION, ITEM A5
 THE FOLLOWING INFORMATION IS REQUIRED -PART 1 - WHEN
 THE LATITUDE AND LONGITUDE ARE PROVIDED BY A SURVEYOR,
 CHECK THE "YES" BOX IN SECTION D AND INDICATE THE
 METHOD USED TO DETERMINE THE LATITUDE AND LONGITUDE IN
 THE COMMENTS AREA OF SECTION D. (EXAMPLES: LATITUDE AND
 LONGITUDE OBTAINED BY MAGELLEN GPS BLAZER 12 / LATITUDE
 AND LONGITUDE DETERMINED BY GOOGLEEARTH.COM / ETC.),
 PART 2 - SELECT HORIZONTAL DATUM USED - NAD 1983 WAS
 SELECTED )
 (PROVIDE TYPE OF EQUIPMENT AND LOCATION PER C2 (E) SEE
 INSTRUCTIONS SECTION D)
  
 4. BUILDING PHOTOGRAPHS - PER INSTRUCTIONS IN SECTION
 A6 ? PROVIDE 2 PHOTOGRAPHS OF THE FOUNDATION SHOWING A
 REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS OR VENTS.
 CORRECTED
  
 5. SECTION D - COPY OF EC WITH SURVEYORS ORIGINAL
 SIGNATURE AND SEAL REQUIRED. (HARD COPY SHALL BE
 SUBMITTED)
  
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2020-04-27 Cont ID  
Sent By CThroop Date 2020-04-27 Time 14:56 Rev Time 0.00
Received By cthroop Date 2020-04-24 Time 16:53 Sent To  
Notes
2020-04-27 15:00:12PLAN REVIEW - NFIP FINISHED CONSTRUCTION ELEVATION
 CERTIFICATE
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER ? BUILDING - PX3169
 PLANS EXAMINER ? 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW - FINISHED CONSTRUCTION EC
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. LINE A5 - LONGITUDE IS EXPRESSED AS EAST OR WEST NOT
 NORTH OR SOUTH. PLEASE CORRECT.
 2. SECTION C - C2 E) LOWEST ELEVATION OF MACHINERY OR
 EQUIPMENT SERVICING THE BUILDING IS SHOWN AS 8.4 FEET.
 THE LOWEST ELEVATION OF THIS EQUIPMENT SHALL BE AT OR
 ABOVE THE DESIGN FLOOD ELEVATION (DFE) OF 9.0 FEET
 NAVD.
 3. SECTION D - (PER FEMA ELEVATION CERTIFICATE
 INSTRUCTIONS, SECTION A - PROPERTY INFORMATION, ITEM A5
 THE FOLLOWING INFORMATION IS REQUIRED -PART 1 - WHEN
 THE LATITUDE AND LONGITUDE ARE PROVIDED BY A SURVEYOR,
 CHECK THE "YES" BOX IN SECTION D AND INDICATE THE
 METHOD USED TO DETERMINE THE LATITUDE AND LONGITUDE IN
 THE COMMENTS AREA OF SECTION D. (EXAMPLES: LATITUDE AND
 LONGITUDE OBTAINED BY MAGELLEN GPS BLAZER 12 / LATITUDE
 AND LONGITUDE DETERMINED BY GOOGLEEARTH.COM / ETC.),
 PART 2 - SELECT HORIZONTAL DATUM USED - NAD 1983 WAS
 SELECTED )
 4. BUILDING PHOTOGRAPHS - PER INSTRUCTIONS IN SECTION
 A6 ? PROVIDE 2 PHOTOGRAPHS OF THE FOUNDATION SHOWING A
 REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS OR VENTS.
 5. SECTION D - COPY OF EC WITH SURVEYORS ORIGINAL
 SIGNATURE AND SEAL REQUIRED.
  
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-03-17 Cont ID  
Sent By cthroop Date 2020-03-17 Time 10:11 Rev Time 0.00
Received By cthroop Date 2020-03-17 Time 08:05 Sent To  
Notes
2020-03-17 10:11:52PLAN REVIEW - NFIP ELEVATION CERTIFICATE - BUILDING
 UNDER CONSTRUCTION
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER - BUILDING - PX3169
 PLANS EXAMINER - 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES.
 ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
  
 1) CORRECTED
 (DIAGRAM NUMBER CHANGED TO 1B)
  
 2) CORRECTED
  
 3) A9(C) ENTER NET AREA OF OPENINGS. PRODUCT APPROVAL
 FL58822-R3 SHOWS MODEL 1540-520 AT .53 SQ. FT. PER
 VENT. (NOT CORRECTED)
 (4 VENTS INSTALLED @ .53 SQ. FT PER VENT = 2.12 SQ. FT.
 X 144 SQ. INCHES/SQ.FT. = 305.28 SQ. INCHES)
 (CHANGE A9 (C) FROM 2.11 SQ. IN. TO 305.28 SQ. IN.)
  
 4) CORRECTED
 (ENGINEERED FLOOD OPENINGS SELECTED)
  
 5) PLEASE STATE IN COMMENTS WHAT VERTICAL DATUM WAS
 UTILIZED FOR A5. (NOT CORRECTED) (CORRECTION TO
 ORIGINAL REVIEW COMMENT REQUIRED)
 (PER FEMA ELEVATION CERTIFICATE INSTRUCTIONS, SECTION A
 - PROPERTY INFORMATION, ITEM A5 THE FOLLOWING
 INFORMATION IS REQUIRED -PART 1 - WHEN THE LATITUDE AND
 LONGITUDE ARE PROVIDED BY A SURVEYOR, CHECK THE "YES"
 BOX IN SECTION D AND INDICATE THE METHOD USED TO
 DETERMINE THE LATITUDE AND LONGITUDE IN THE COMMENTS
 AREA OF SECTION D. (EXAMPLES: LATITUDE AND LONGITUDE
 OBTAINED BY MAGELLEN GPS BLAZER 12 / LATITUDE AND
 LONGITUDE DETERMINED BY GOOGLEEARTH.COM / ETC.),
 PART 2 - SELECT HORIZONTAL DATUM USED - NAD 1983 WAS
 SELECTED )
  
 NEW COMMENT:
  
 UPON SUBMITTAL OF FINISHED CONSTRUCTION ELEVATION
 CERTIFICATE, PROVIDE THE FOLLOWING INFORMATION:
  
 6) C2 (E) LOWEST ELEVATION OF MACHINERY OR EQUIPMENT
 SERVICING THE BUILDING SHALL BE AT OR ABOVE DFE OF 9.0
 FEET NAVD
  
 7) FEMA ELEVATION CERTIFICATES ARE LEGAL DOCUMENTS,
 BUILDING OWNER'S NAME IN SECTION A1 MUST BE PERMAMENT
 AND CANNOT BE ALTERED.
  
 8) PHOTOGRAPHS PROVIDED WITH ELEVATION CERTIFICATE
 INDICATE 1ST FLOOR HAS NOT BEEN CAST. AN UNDER
 CONSTRUCTION ELEVATION CERTIFICATE REQUIRES THE FIRST
 FLOOR TO BE IN PLACE - SEE SECTION C2 (A), PG. 2 OF 6
 OF ELEVATION CERTIFICATE AND FEMA ELVATION CERTIFICATE
 INSTRUCTIONS ITEMS C2. A-D, PG. 4 OF 9.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-05-12 Cont ID  
Sent By skennedy Date 2020-05-07 Time 14:25 Rev Time 0.00
Received By skennedy Date 2020-05-07 Time 14:25 Sent To  
Notes
2020-05-12 14:25:46ON CTHROOPS DESK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-05-04 Cont ID  
Sent By cthroop Date 2020-05-04 Time 14:03 Rev Time 0.00
Received By cthroop Date 2020-05-04 Time 14:03 Sent To  
Notes
2020-05-04 14:05:07APPLICANT WILL DROP OFF HARD COPY OF ELEVATION
 CERTIFICATE WITH ORIGINAL SIGNATURE AND SEAL OF
 SURVETOR. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-04-24 Cont ID  
Sent By jgomez Date 2020-04-24 Time 14:50 Rev Time 0.00
Received By jgomez Date 2020-04-24 Time 14:40 Sent To  
Notes
2020-04-24 14:51:00CONVERTED TO DIGITAL.
 ELEVATION CERTIFICATE WITH SURVEYOR'S ORIGINAL
 SEAL/SIGNATURE ON CITY'S FILE. JG