| Plan Review Stops For Permit 19120885 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-06 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-06 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2020-05-06 10:00:09 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) EXTERIOR WALL CANNOT BE BUILT CODE PRESCRIPTIVE PER | | | FBC R301.2.1.1 | | | 2) PLEASE PROVIDE DIGITALLY SIGNED AND SEALED EXTERIOR | | | WALL DRAWINGS FROM AN ARCHITECT OR ENGINEER TO COMPLY | | | WITH WIND LOADS PER FBC 1609.1.1 | | | 3) PLEASE SHOW THE WIND DESIGN DATA USED PER FBC | | | 1603.1.4 | | | 4) WALL DETAILS SHOWN ON THE DRAWING (2 OF 4) IS | | | MISSING - BEAM SIZE, STRAPPING TYPE NAME - NUMBER OF | | | NAILS - SIZE OF NAILS, - IS THE ROOF EXISTING? - IF SO | | | PLEASE STATE AS SUCH ON THE DRAWING. | | | 5) PLEASE PROVIDE MIAMI DADE OR FLORIDA STATE PRODUCT | | | APPROVALS FOR THE ROOFING - SHOWN ON THE DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-07 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-07 |
Time |
11:36 |
Sent To |
HIST |
|
| Notes |
| 2020-01-07 18:09:17 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 1- PLANS SUBMITTED SHOW A DINING ROOM AND BEDROOM #2 ON | | | THE REAR OF THE MAIN HOUSE. ACCORDING TO CITY RECORDS | | | AND PROPERTY APPRAISER THIS AREA WAS A PORCH NOT | | | LIVABLE SPACE. | | | THERE ARE NO CITY RECORDS SHOWING PERMITS FOR THE | | | CONVERSION OF THE PORCH TO LIVABLE SPACE. IT LOOKS LIKE | | | THE WORK WAS DONE WITHOUT PERMITS AND INSPECTIONS. NEED | | | TO REVISE PLANS TO SHOW THE ENCLOSURE OF THE PORCH TO | | | INCREASE THE LIVABLE SPACE. PROVIDE COMPLETE | | | INFORMATION, INCLUDING DIMENSIONS FOR THE ROOMS AND | | | FRAMING DETAILS FOR THE DOORS AND WINDOWS. SPECIFY ALL | | | FRAMING MEMBERS AND CONNECTORS. SEC. 801.3 FBC-EXISTING | | | BUILDING AND SEC. R301.2.1 FBC-RESIDENTIAL. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 2- WINDOW SIZE FOR NEW BEDROOM #2 DOESN'T COMPLY WITH | | | THE EGRESS REQUIREMENTS. REVISE AS REQUIRED SHOWING | | | COMPLIANCE. SEC. 801.3 FBC-EXISTING BUILDING AND SEC. | | | R310.2.1 FBC-RESIDENTIAL. | | | | | | 3- WINDOW REPLACEMENT ON THE REST OF THE HOUSE: CLEARLY | | | SPECIFY TYPE AND SIZE OF EXISTING WINDOWS AND TYPE AND | | | SIZE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE WITH THE | | | EGRESS REQUIREMENTS OF SEC. 702.5 FBC-EXISTING | | | BUILDING. | | | | | | NOTE: NEED TO VERIFY MANUFACTURER'S LARGEST STANDARD | | | SIZE WINDOW THAT WILL FIT WITHIN THE EXISTING FRAME OR | | | EXISTING ROUGH OPENING AND THAT WILL NOT REDUCE THE | | | EGRESS SIZE OPENING OF EXISTING WINDOW AS REQUIRED BY | | | SEC. 702.5 FBC-EXISTING BUILDING. | | | | | | 4- SHUTTERS FLORIDA PRODUCT APPROVAL FL11398-R4 | | | SUBMITTED: PROVIDE COMPLETE INSTALLATION SCHEDULE AS | | | REQUIRED BY CITY IMPLEMENTATION STANDARD FOR WIND-BORNE | | | DEBRIS IMPACT PROTECTION FOR THE FLORIDA BUILDING CODE. | | | SEE CITY SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED. | | | ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION | | | SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE | | | REQUIRED INFORMATION IS PROVIDED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 5- IMPACT FEES: BECAUSE OF THE LIVABLE AREA ADDITION | | | THE PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. | | | CALL (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-04-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-04-22 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-04-22 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2020-04-22 08:13:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. LOAD CALCULATION PROVIDED EXCEEDS THE CAPACITY OF | | | THE SERVICE AND THE NEW PANEL SPECIFIED ON RISER | | | DIAGRAM. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THIS LOAD CALCULATION SHOULD BE IN | | | THE FORMAT SPECIFIED IN THE FBC RESIDENTIAL. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 (NOT PROVIDED OR | | | CORRECTED.) | | | 2. PROVIDE CORRECTIONS TO ANY SERVICE EQUIPMENT THAT IS | | | UNDERSIZED. NEC 110.3, 215.2, 240.4, 408.30 (NOT | | | CORRECTED. MAIN BREAKER IN RISER STILL SHOWS AS 100 | | | AMP.) | | | 3. IF SERVICE IS TO BE UPGRADED, PROVIDE AVAILABLE | | | SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING | | | INFORMATION FROM THE POWER COMPANY STATING WHAT THE | | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | | CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT | | | IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 (NOT | | | PROVIDED OR ADDRESSED.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-30 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-30 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2019-12-30 08:47:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. LOAD CALCULATION PROVIDED EXCEEDS THE CAPACITY OF | | | THE SERVICE AND THE NEW PANEL SPECIFIED ON RISER | | | DIAGRAM. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THIS LOAD CALCULATION SHOULD BE IN | | | THE FORMAT SPECIFIED IN THE FBC RESIDENTIAL. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 | | | 2. PROVIDE CORRECTIONS TO ANY SERVICE EQUIPMENT THAT IS | | | UNDERSIZED. NEC 110.3, 215.2, 240.4, 408.30 | | | 3. IF SERVICE IS TO BE UPGRADED, PROVIDE AVAILABLE | | | SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING | | | INFORMATION FROM THE POWER COMPANY STATING WHAT THE | | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | | CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT | | | IS ADEQUATE. NEC 110.9, 110.10; FBC RE E3606.3 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-04-27 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2020-04-27 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-04-27 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2020-04-27 12:47:59 | EXTERNAL DIMENSIONAL MUNTINS WITH A LOW FLAT PROFILE OR | | | PYRAMID. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-01-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-07 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2020-01-08 |
Time |
15:13 |
Sent To |
PC |
|
| Notes |
| 2020-01-08 15:15:14 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PLEASE FOLLOW THE WPB-HP WINDOW PERMIT APPLICATION | | | EXAMPLE.PDF EXAMPLE FOR BOTH THE WINDOWS AND DOORS. | | | THIS DOCUMENT CAN BE OBTAINED BY EMAILING | | | [email protected]. I HAVE ALSO INCLUDED A COPY WITH | | | THE PERMIT. YOUR RESUBMITTAL SHOULD INCLUDE PHOTOS | | | IDENTIFYING THE EXISTING WINDOWS, AND PROPOSED WINDOWS. | | | | | | A. SINGLE-HUNG WINDOWS SHOULD MATCH THE AWNING WINDOW | | | CONFIGURATION WITH EXTERNAL DIMENSIONAL MUNTINS IN | | | EITHER A PYRAMID OR LOW FLAT PROFILE. | | | B. ALL FRONT ELEVATION WINDOWS (AND DOORS) NEED TO HAVE | | | CLEAR GLASS. | | | C. ALL REMAINING ELEVATIONS CAN HAVE CLEAR GLASS OR | | | CLEAR GLASS WITH LOW-E COATING. | | | D. ALL WINDOWS AND THE SLIDING GLASS DOOR SHOULD HAVE | | | AN ANODIZED FINISH. | | | | | | 2. PROVIDE A PHOTO OF THE EXISTING DOORS AND PROVIDE A | | | GRAPHIC OF WHAT THE PROPOSED DOORS WILL LOOK LIKE. | | | | | | | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | | | 2020-01-07 15:50:56 | ***NOTE: | | | THIS BUILDINGS WERE NOT FLAGGED AS HISTORIC AND ARE | | | CONTRIBUTING HISTORIC BUILDINGS. ADDED HISTORIC HOLD. | | | UNFORTUNATELY ROOF TILE WAS REPLACED IN 1998 AND 2004 | | | WITH SHINGLES WITHOUT HISTORICAL REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-06 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-04-14 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-01-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-01-08 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-12-19 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-05-06 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-05-06 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2020-05-06 10:21:32 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-07 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-07 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2020-01-07 16:39:10 | IMPACT FEES - | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-05-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-05-05 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-04-29 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2020-05-05 12:20:17 | | | | 3RD REVIEW FBC-2017 PLUMBING | | | PERMIT #19120885 | | | 5/5/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A PRODUCT DATA SHEET HAS BEEN SUBMITTED FOR A NEW | | | 28-GALLON ELECTRIC WATER HEATER HOWEVER THE PLANS SHOW | | | ALL EXISTING WATER HEATERS. PLEASE SHOW THE LOCATION OF | | | THE NEW WATER HEATER AND ADD IT TO THE THE PLUMBING | | | SCOPE OF WORK ON SHEET 1- SECTION 107.2.1 WPB. PLEASE | | | NOTE THAT A THERMAL EXPANSION DEVICE IS REQUIRED TO BE | | | INSTALLED AT THE SUPPLY LINE TO THE WATER HEATER PER | | | SECTION P2903.4 FBC RES. | | | | | | 2) TWO DWELLING UNITS ARE SHOWN TO BE OR THE SAME LOT | | | WHICH REQJUIRES INSTALLATION OF AN RPZ-TYPE BACKFLOW | | | PREVENTER TO BE INSTALLED AT THE WATER METER ACCORDING | | | TO THE CITY OF WPB CROSS-CONNECTION MANUAL. A SEPARATE | | | PERMIT IS REQUIRED FOR THE INSTALLATION. PLEASE CONTACT | | | THE THE CITY OF WPB UTILITIES DEPT. AT 561-822-2240 FOR | | | MORE INFORMATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | 2020-04-30 15:33:07 | 04/30/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-701-6437 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-01-02 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-01-02 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2020-01-02 06:56:28 | 01/02/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-701-6437 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-04-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-04-17 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-04-17 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2020-04-17 15:09:50 | NO LICENSED ARCHITECT/ENGINEER PLANS. JG. |
|
|