Plan Review Details - Permit 19120803
Plan Review Stops For Permit 19120803
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-04-21 Cont ID  
Sent By pvalenti Date 2020-04-21 Time 13:41 Rev Time 0.00
Received By pvalenti Date 2020-04-21 Time 12:41 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-03-10 Cont ID  
Sent By pvalenti Date 2020-03-10 Time 15:52 Rev Time 0.00
Received By pvalenti Date 2020-03-10 Time 10:33 Sent To  
Notes
2020-03-10 15:53:19ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-01-21 Cont ID  
Sent By jwitmer Date 2020-01-21 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2020-01-21 Time 07:48 Sent To  
Notes
2020-01-21 15:17:32ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2020-05-05 Cont ID  
Sent By pvalenti Date 2020-05-05 Time 08:37 Rev Time 0.00
Received By pvalenti Date 2020-05-05 Time 08:37 Sent To  
Notes
2020-05-05 08:49:53PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 AT TIME OF INSPECTION, THE VERTICAL CHANGE IN LEVEL
 (MAX. 1/4") AT THE NEW DOOR OPENING SHALL COMPLY WITH
 SECTION FBC A 303.
  
 THE DOORS 105A AND 105B WILL NEED TO HAVE 48"
 SEPARATION IF THIS BATHROOM IS NOT DESIGNATED FOR ONLY
 ONE PERSON AT A TIME (PRIVATE). AT TIME OF INSPECTION,
 PER FBC A 404.2.6, REMOVAL OF THE BATHROOM DOOR # 105B
 MAY BE REQUIRED.
  
 FOR ANY WELDING ON THIS PROJECT:
 AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-04-21 Cont ID  
Sent By pvalenti Date 2020-04-21 Time 15:28 Rev Time 0.00
Received By pvalenti Date 2020-04-21 Time 12:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-11 Cont ID  
Sent By pvalenti Date 2020-03-11 Time 09:07 Rev Time 0.00
Received By pvalenti Date 2020-03-10 Time 10:33 Sent To  
Notes
2020-03-11 10:52:04***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 2ND BUILDING REVIEW DENIED:
  
 1. APPROVED
 2. APPROVED
 3. APPROVED
 4. APPROVED
 5. APPROVED
 6. APPROVED
 7. APPROVED WITH PROVISO, AT TIME OF INSPECTION, THE
 VERTICAL CHANGE IN LEVEL (MAXIMUM 1/4") AT THE NEW DOOR
 OPENING SHALL COMPLY WITH SECTION FBC A 303.
 8. APPROVED
 9. APPROVED WITH PROVISO, PLEASE SUBMIT A CLARIFICATION
 TO TABLE ITEMS MARKED E5 AND E6 ON PAGE A5.0. THESE
 ITEMS ARE LABELED AS PRE-ENGINEERED, SHOULD HAVE BEEN
 LABELED AS PRE-FINISHED.
 10. APPROVED
 11. APPROVED
 12. APPROVED
 13. APPROVED
 14. APPROVED WITH PROVISO, THE DOORS 105A & 105B WILL
 NEED TO HAVE 48" SEPARATION IF THIS BATHROOM IS NOT
 DESIGNATED FOR ONLY ONE PERSON AT A TIME (PRIVATE). AT
 TIME OF INSPECTION PER FBC A 404.2.6. REMOVAL OF
 INTERIOR BATHROOM DOOR # 105B MAY BE REQUIRED.
 15. APPROVED
 16. APPROVED
 17. APPROVED WITH PROVISO, WHEN THERE
 IS EITHER WELDING OR BOLTING OF STRUCTURAL MEMBERS THEN
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION. IN ACCORDANCE WITH THE
 AMERICAN WELDING SOCIETY.
 2017 FBC?B 2204.1 WELDING
 2017 FBC?B 2204.2 BOLTING.
 18. APPROVED
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-21 Cont ID  
Sent By jwitmer Date 2020-01-21 Time 15:20 Rev Time 0.00
Received By jwitmer Date 2020-01-21 Time 07:48 Sent To  
Notes
2020-01-21 15:18:182017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19120803
 ADD: 2715 PINEWOOD AVE. BUILDING A
 CONT: WALKER DESIGN & CONSTRUCTION
 TEL: 561-998-0001
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 21/2020
 ACTION: DENIED
  
 1) THE VALUE OF THE PERMIT VALUE IS EXTREMELY,
 EMBRACING LOW FOR THE SCOPE OF WORK ($15,000.00).
 BEFORE THE NEXT SUBMITTAL PLEASE UPDATE THE VALUE TO AN
 APPROPRIATE VALUE FOR THE SCOPE OF WORK. OTHERWISE WE
 WILL DO A CALCULATED VALUE USING THE CURRENT ICC COST
 TABLES.
  
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION 108.3*
 BUILDING PERMIT VALUATION. IF, IN THE OPINION OF THE
 BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL, OR
 PLUMBING SYSTEMS APPEARS TO BE UNDER ESTIMATED ON THE
 APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL
 TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED
 SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE,
 LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR
 FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE
 REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
 2A) THIS MAYBE A TYPO, THE OCCUPANCY TYPES LISTED ON
 SHEET A1.0 THE TITLE INDEX- CODE BUILDING SHEET LIST
 THE OCCUPANCY TYPES AS BUSINESS & F1. WHEREAS ON SHEET
 A1.1 CODE AND SPECS FIRE RESISTANCE RATINGS FOR
 EXTERIOR WALLS PER TABLE 602 THE OCCUPANCY TYPES LISTED
 ARE BUSINESS AND S-1 STORAGE NOT THE F1? 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2B) SHEET A1.1 THE HEADING FOR FIRE RESISTANCE RATINGS
 FOR EXTERIOR WALLS PER TABLE 602 10 X <30 FEET LIST A 1
 HOUR FIRE RATING FOR THE EXTERIOR WALLS FOR BUSINESS
 AND S-1 STORAGE OR THE F-1 FACTORY INDUSTRIAL USE.
 PLEASE REFER TO TABLE 602, THE EXTERIOR WALLS DO NOT
 REQUIRE ANY FIRE RATING FOR THE EXTERIOR WALLS.
  
 2C) SHEET A-1.0 UNDER THE HEADING OCCUPANCY
 CLASSIFICATION FFPC SECTION 6.1.14.1.3 REFERS TO THE
 F-2 OCCUPANCY AGAIN. IS THE FACTORY/ INDUSTRIAL USE F1
 OR F2? DISCREPANCY IN PLANS.
  
 3) SHEET A-1.1 UNDER THE HEADING OF 130 CODES (B) THE
 OCCUPANCY TYPES ARE LISTED AS BUSINESS & F2 NOT THE F1
 LISTED ON SHEET A1.0. DISCREPANCY IN CODES. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 4) SHEET A-1.1 UNDER THE HEADING INTERIOR WALL FINISHES
 TABLE803.9 INDICATES FOR FACTORY OCCUPANCY/
 NON-SPRINKLERED UPDATE THE CORRIDOR FINISH TO C
 FINISHES NOT B PER TABLE 803.1.1 OF THE 2017 FBC-B.
  
 5A) SHEET A-1.1 INDICATES A CODE SECTION 1406.2.2 THAT
 DEALS WITH EXTERIOR WALL COVERINGS, BUT THERE IS NO
 MENTION OF THE REQUIREMENTS FOR NON-COMBUSTIBLE
 CONSTRUCTION FOR TYPE II CONSTRUCTION. SHEET S3.0 SHOWS
 THE USE OF 19/32ND INCH CDX PLYWOOD AS SUB-SHEATHING IN
 THE NEW PARAPET WALLS. THE NEW SLOPED EXTERIOR STEEL
 WALLS ALSO SHOWS 19/32ND CDX SUB-SHEATHING BEING
 INSTALLED TO THE STRUCTURAL STEEL STUDS.
 PLEASE REFER TO THE 2017 FBC-B SECTION 603.1.1
 FIRE-RETARDANT- TREATED WOOD, 1.2 NONBEARING EXTERIOR
 WALLS AND 1.3ROOF CONSTRUCTION INCLUDING FRAMING AND
 DECKING. PLEASE UPDATE THIS SHEET TO FIRE RETARDANT
 TREATED PLYWOOD.
  
 5B) SHEET S3.0 DETAIL # 1 SHOWS NEW STRUCTURAL STEEL
 STUDS 6 INCH@ 24 INCHES ON CENTER AND THE NEW SLOPED
 STEEL STUD WALL AND BRACING. IT APPEARS THERE IS NO
 SUB-SHEATHING BETWEEN THE VERTICAL FRAMING MEMBERS. IS
 THERE TO BE ANY CONNECTION BETWEEN THE 2 STRUCTURAL
 MEMBERS, ARE THEY TO ALIGN TO BE ANCHORED TOGETHER?
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. DETAIL 2
 ON THE SAME SHEET SHOWS THE NEW STEEL FRAMING MEMBERS
 BEING ANCHORED INTO THE STRUCTURAL CONCRETE BEAM BUT
 THERE IS NO INFORMATION ON THE ANCHORS. DETAIL 4 THE
 SAME PAGE INDICATES THE NEW METAL ROOF FRAMING AND
 METAL ROOFING SYSTEM ARE TO BE DESIGNED BY THE
 SPECIALTY ENGINEER, IS THE SAME TO BE SAID ABOUT THE
 NEW EXTERIOR WALL SYSTEMS? 107.2.1.2 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 6) THE LIFE SAFETY SHEET A4.1 SHOWS THE COMMON PATH OF
 TRAVEL IS EXCEEDED REQUIRING 2 EXITS. THE LIFE SAFETY
 PLAN DOES SHOW 2 EXITS BUT THE BACK EXIT DOES NOT SHOW
 FROM THE EXIT DISCHARGE OF THE BUILDING, THE EGRESS
 PATH TO THE PUBLIC WAY. THERE WAS NO SITE PLAN
 SUBMITTED SHOWING THE EGRESS PATH TO THE PUBLIC WAY OR
 COMPLIANCE WITH THE 2017 FBC-B 1028.5 ACCESS TO A
 PUBLIC WAY.
  
 7) NEITHER SHEET A4.0 NOR A4.1 SHOW THE GRADE
 DIFFERENCE AT EITHER EXIT DOORWAY. GOOGLE EARTH DOES
 SHOW A DROP AT THE NEW PROPOSED EXIT FROM THE BUSINESS
 OCCUPANCY.
 2017 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF
 EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE
 INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001
 SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL
 BUILDING CODE (2003 EDITION).
 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS
 IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY
 ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE
 SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS.
 2017 ACCESSIBILITY CODE CHANGES IN LEVEL303.2.
 VERTICAL. CHANGES IN LEVEL ARE PERMITTED IN FLOOR OR
 GROUND SURFACES, THEY SHALL COMPLY WITH 303.
  
 8) SHEET S-4.0 WIND PRESSURES, THE NEGATIVE PRESSURES
 FOR WALL ZONES 4 & 5 ARE APPROXIMATELY 3 PSF LOW FOR A
 MEAN ROOF HEIGHT OF 15 FEET, FOR EXPOSURE C AND BASED
 ON KD=0.85 USING ASCE FIGURE 30.5-1 OF ASCE 7-10. NOTE
 ROOF PRESSURES FOUND ON S-5.0 FOR ROOF ZONES 1,2 & 3
 ARE GOOD.
  
 9) SHEET A-5.0 INDICATES WITH MARKS E5, & E6 THAT THESE
 WALLS ARE PRE-ENGINEERED. IS THIS MEANT THE STRUCTURAL
 STEEL WALL FRAMING MEMBERS WERE ASSEMBLED AT A FACTORY
 LIKE ROOF TRUSSES? THERE IS ALSO HC-16 AND HR-16
 PANELS, IS THIS A PRE-MANUFACTURED WALL SYSTEM
 INCLUDING THE EXTERIOR WALL PANELS? IF SO WHO, OR WHAT
 AGENCY IS DOING THE INSPECTIONS AT THE MANUFACTURING
 SITE? 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 10) COMPONENTS & CLADDING. 2017 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS ,MULLIONS
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS, ACM PANELS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 11A) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 11B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 11C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 12) THE PLANS ALSO INDICATE THE USE OF ACM PANELS
 PLEASE SHOW COMPLIANCE WITH 2017 FBC-B SECTIONS:
 1407.4 STRUCTURAL DESIGN,
  
 12A) MCM SYSTEMS SHALL BE DESIGNED AND CONSTRUCTED TO
 RESIST WIND LOADS AS REQUIRED BY CHAPTER 16 FOR
 COMPONENTS AND CLADDING.
  
 12B) 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR AN
 ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE BUILDING
 OFFICIAL TO VERIFY COMPLIANCE WITH THE REQUIREMENTS OF
 CHAPTER 16 FOR WIND LOADS.
  
 12C) 1407.6 WEATHER RESISTANCE. MCM SYSTEMS SHALL
 COMPLY WITH SECTION 1403 AND SHALL BE DESIGNED AND
 CONSTRUCTED TO RESIST WIND AND RAIN IN ACCORDANCE WITH
 THIS SECTION AND THE MANUFACTURER?S INSTALLATION
 INSTRUCTIONS.
  
 12D) 1407.7 DURABILITY. MCM SYSTEMS SHALL BE
 CONSTRUCTED OF APPROVED MATERIALS THAT MAINTAIN THE
 PERFORMANCE CHARACTERISTICS REQUIRED IN SECTION 1407
 FOR THE DURATION OF USE.
  
 12E) 1407.8 FIRE-RESISTANCE RATING. WHERE MCM SYSTEMS
 ARE USED ON EXTERIOR WALLS REQUIRED TO HAVE A
 FIRE-RESISTANCE RATING IN ACCORDANCE WITH SECTION 705,
 EVIDENCE SHALL BE SUBMITTED TO THE BUILDING OFFICIAL
 THAT THE REQUIRED FIRE-RESISTANCE RATING IS MAINTAINED.
 EXCEPTION: MCM SYSTEMS NOT CONTAINING FOAM PLASTIC
 INSULATION, WHICH ARE INSTALLED ON THE OUTER SURFACE OF
 A FIRE-RESISTANCE-RATED EXTERIOR WALL IN A MANNER SUCH
 THAT THE ATTACHMENTS DO NOT PENETRATE THROUGH THE
 ENTIRE EXTERIOR WALL ASSEMBLY, SHALL NOT BE REQUIRED TO
 COMPLY WITH THIS SECTION.
  
 12F) 1407.9 SURFACE-BURNING CHARACTERISTICS. UNLESS
 OTHERWISE SPECIFIED, MCM SHALL HAVE A FLAME SPREAD
 INDEX OF 75 OR LESS AND A SMOKE-DEVELOPED INDEX OF 450
 OR LESS WHEN TESTED IN THE MAXIMUM THICKNESS INTENDED
 FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
 12G) 1407.10 TYPE I, II, III AND IV CONSTRUCTION. WHERE
 INSTALLED ON BUILDINGS OF TYPE I, II, III AND IV
 CONSTRUCTION, MCM SYSTEMS SHALL COMPLY WITH SECTIONS
 1407.10.1 THROUGH 1407.10.4, OR SECTION 1407.11.
  
 13) PLEASE NOTE ON SHEET A-4.3 THE PLAN MAKES REFERENCE
 TO THE GOVERNING CODE ADAAG. THE DEPARTMENT OF JUSTICE
 HAS BLESSED THE 2017 FBC-ACCESSIBILITY CODE. THE INTENT
 AS ESTABLISHED BY S.553.502, FLORIDA STATUTES, IS TO
 MAINTAIN THE US DEPARTMENT OF JUSTICE CERTIFICATION OF
 THE CODE AS SUBSTANTIALLY EQUIVALENT TO THE ADA
 STANDARDS SO COMPLIANCE WITH THE CODE PROVIDES
 PRESUMPTION OF COMPLIANCE WITH THE ADA STANDARDS.
  
 13A) DETAIL # 2 GRAB BARS ARE TO COMPLY WITH: 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 13B) DETAIL # 2, THE TOILET PAPER HOLDER TO COMPLY
 WITH: 2017 FBC-ACCESS. CODE 604.7 DISPENSERS. TOILET
 PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE 7
 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE
 WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 13C)(1) THE LIFE SAFETY PLAN NOR A-4.0 SHOW DRINKING
 FOUNTAINS. PLEASE SHOW COMPLIANCE WITH THE . 2017
 FBC-ACCESSIBILITY CODE SECTION 211.2 MINIMUM NUMBER. NO
 FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 13C)(2) DEPENDING ON THE LOCATION OF THE DRINKING
 FOUNTAINS THE NEED TO SHOW COMPLIANCE WITH THE 2017
 FBC-ACCESSIBILITY CODE SECTION 602.1 DRINKING FOUNTAINS
 SHALL COMPLY WITH 307. PROTRUDING OBJECTS.
  
 13D) DETAIL # 5 MAKES REFERENCES TO FACBC 11.4 THIS
 REFERENCE IS NOT TO THE CURRENT CODE SECTIONS. UNDER
 THE 2017 FBC-ACCESSIBILITY CODE THERE IS NO CHAPTER 11.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 14) SHEET A4.4 AND FIGURE 404.2.6 IS A FIGURE FOR DOORS
 IN SERIES A MINIMUM OF 4 FEET CLEAR FROM ONE DOOR LEAF
 TO ANOTHER. SHEET A-4.0 DOES NOT SHOW COMPLIANCE WITH
 THIS SECTION.
  
 15) THE SHOWER SHOWN ON SHEET A-4.0 SHOWS AN ACCESSIBLE
 SHOWER 3X3 FEET. THE SHOWER SEAT DOES NOT CONTINUE TO
 THE OUTER WALL OF THE SHOWER OR WITHIN 3 INCHES OF THIS
 WALL NOR COMPLIANCE WITH 610.3 ALSO REVIEW FIGURE
 610.3.
  
 16) SHEET A4.0 THE FLOOR PLAN SHOWS A BREAK ROOM SINK,
 THERE IS NO DETAIL FOR THIS AREA. SHEET A-6.0 DETAIL 3
 SECTION THROUGH THE BUILDING SHOWS THE ELEVATION VIEW
 OF THE SAME BREAK ROOM COUNTER AND SINK BUT THERE IS NO
 DIMENSION FOR THE SINK OR COMPLIANCE WITH: 2017
 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. LAVATORIES
 AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE
 HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
  
 17) SHEETS A-6.0 AND S-3.0 BOTH SHOW THE INSTALLATION
 OF STRUCTURAL STEEL FRAMING MEMBERS AND ANCHORING OF
 ROOF FRAMING INTO THE TWIN TEE ROOF FRAMING. WHEN THERE
 IS EITHER WELDING OR BOLTING OF STRUCTURAL MEMBERS THEN
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION. IN ACCORDANCE WITH THE
 AMERICAN WELDING SOCIETY.
 2017 FBC-B 2204.1 WELDING
 2017 FBC-B 2204.2 BOLTING.
 THE CONTRACTOR WOULD NEED TO GET A 3RD PARTY ENGINEER
 TO PROVIDE INSPECTIONS. CURRENTLY THERE ARE NO SHOP
 DRAWING SUBMITTED, CONNECTION TYPE ARE UNKNOWN.
 IF THERE IS ANY QUESTIONS ABOUT THE CODE REQUIREMENTS
 FOR THIS SECTION, PLEASE CONTACT THE CHIEF BUILDING
 INSPECTOR KEN CONRAD AT 561-805-6666. THANK YOU.
  
 18) THE MECHANICAL SHEETS SHOW NEW A/C IN THE BUSINESS
 OCCUPANCY PLEASE SHOW HOW COMPLIANCE WILL BE ACHIEVED
 WITH THE 2017 ENERGY CODE SECTION C401.2 APPLICATION.
 COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE
 FOLLOWING:
 1.THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, EXCLUDING
 SECTION 9.4.1.1(G) OF THE STANDARD.
 2.THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN
 ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH
 SECTION C406 AND TENANT SPACES SHALL COMPLY WITH
 SECTION C406.1.1.
 3.THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404,
 C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING
 ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT
 OF THE STANDARD REFERENCE DESIGN BUILDING.
  
 19) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2020-05-05 Cont ID  
Sent By jpearson Date 2020-05-05 Time 08:17 Rev Time 0.00
Received By jpearson Date 2020-05-05 Time 08:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-04-22 Cont ID  
Sent By jpearson Date 2020-04-22 Time 09:28 Rev Time 0.00
Received By jpearson Date 2020-04-22 Time 09:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-03-10 Cont ID  
Sent By jpearson Date 2020-03-10 Time 07:01 Rev Time 0.00
Received By jpearson Date 2020-03-10 Time 07:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-01-29 Cont ID  
Sent By jpearson Date 2020-01-29 Time 07:55 Rev Time 0.00
Received By jpearson Date 2020-01-29 Time 06:37 Sent To  
Notes
2020-01-29 07:55:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF
 SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND
 AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24
 2. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2
 3. PROVIDE GFCI PROTECTION FOR RECEPTACLES OUTLETS
 SUSPENDED BY CORD IN SHOP AREA, NOTED BY KEYNOTE NUMBER
 2. NEC 210.8(B)(8)
 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94
 5. PROVIDE NOTES FOR REQUIRED MARKING OF HIGH LEG. NEC
 110.15, 230.56, 408.3(E)
 6. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING
 PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK
 IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY
 OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2020-05-01 Cont ID  
Sent By pleduc Date 2020-05-01 Time   Rev Time 0.00
Received By pleduc Date 2020-05-01 Time 12:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-04-21 Cont ID  
Sent By pleduc Date 2020-04-21 Time   Rev Time 0.00
Received By pleduc Date 2020-04-21 Time 12:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-03-12 Cont ID  
Sent By pleduc Date 2020-03-12 Time   Rev Time 0.00
Received By pleduc Date 2020-03-12 Time 16:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-01-15 Cont ID  
Sent By pleduc Date 2020-01-15 Time   Rev Time 0.00
Received By pleduc Date 2020-01-15 Time 10:57 Sent To  
Notes
2020-01-15 11:20:57THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 1.0 - THERE ARE INDICATION OF INDUSTRIAL
 OCCUPANCY; HOWEVER, THERE ARE NO INDICATIONS OF THE
 TYPE OF WORK BEING PERFORMED.
  
 PLEASE PROVIDE A DETAILED NARRATIVE OF WHAT IS BEING
 MANUFACTURED, HOW IT IS RECEIVED, WHAT HAPPENS TO THE
 WASTE PRODUCTS, WHERE THE COMPLETED PRODUCT IS STORED,
 ETC?
  
  
  
 2) SHEET A 1.0 - WHAT IS THE HAZARD OF CONTENTS &
 CLASSIFICATION OF HAZARD PER NFPA 101, CH 6 OCCUPANCY
 CLASSIFICATION.
  
 PER NFPA 101, CH 6
  
 6.2 HAZARD OF CONTENTS.
 6.2.1 GENERAL.
 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF
 CONTENTS SHALL
 BE THE RELATIVE DANGER OF THE START AND SPREAD OF FIRE,
 THE DANGER OF
 SMOKE OR GASES GENERATED, AND THE DANGER OF EXPLOSION
 OR OTHER
 OCCURRENCE POTENTIALLY ENDANGERING THE LIVES AND SAFETY
 OF THE
 OCCUPANTS OF THE BUILDING OR STRUCTURE.
 6.2.1.2 HAZARD OF CONTENTS SHALL BE CLASSIFIED BY THE
 REGISTERED
 DESIGN PROFESSIONAL (RDP) OR OWNER AND SUBMITTED TO THE
 AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL
 ON THE BASIS
 OF THE CHARACTER OF THE CONTENTS AND THE PROCESSES OR
 OPERATIONS
 CONDUCTED IN THE BUILDING OR STRUCTURE.
 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT
 DEGREES OF
 HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS OF A
 BUILDING OR STRUCTURE,
 THE MOST HAZARDOUS SHALL GOVERN THE CLASSIFICATION,
 UNLESS
 HAZARDOUS AREAS ARE SEPARATED OR PROTECTED AS SPECIFIED
 IN SECTION
 8.7 AND THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH
 43.
  
 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS.
 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY
 BUILDING OR
 STRUCTURE SHALL BE CLASSIFIED AS LOW, ORDINARY, OR HIGH
 IN
 ACCORDANCE WITH 6.2.2.2, 6.2.2.3, AND 6.2.2.4.
 6.2.2.2* LOW HAZARD CONTENTS. LOW HAZARD CONTENTS SHALL
 BE
 CLASSIFIED AS THOSE OF SUCH LOW COMBUSTIBILITY THAT NO
 SELFPROPAGATING
 FIRE THEREIN CAN OCCUR.
 6.2.2.3* ORDINARY HAZARD CONTENTS. ORDINARY HAZARD
 CONTENTS SHALL
 BE CLASSIFIED AS THOSE THAT ARE LIKELY TO BURN WITH
 MODERATE RAPIDITY OR
 TO GIVE OFF A CONSIDERABLE VOLUME OF SMOKE.
 6.2.2.4* HIGH HAZARD CONTENTS. HIGH HAZARD CONTENTS
 SHALL BE
 CLASSIFIED AS THOSE THAT ARE LIKELY TO BURN WITH
 EXTREME RAPIDITY OR FROM
 WHICH EXPLOSIONS ARE LIKELY. (FOR MEANS OF EGRESS
 REQUIREMENTS, SEE
 SECTION 7. 11.)
  
  
 3) SHEET A 4.0 - THERE ARE INDICATION OF RACKS;
 HOWEVER, THERE ARE NO RACK DETAILS.
  
 PLEASE PROVIDE ALL APPLICABLE DETAILS RELATED TO RACKS,
 INCLUDING PALLET TYPES, COMMODITY TYPE, WRAPPING TYPES,
 SHELLVING TYPES, HEIGHTS, WEIGHT LIMITS, ETC, FOR
 REVIEW PURPOSES.
  
 RACKS SHALL BE INSTALLED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
  
 4) SHEET 4.0 - THERE ARE INDICATION OF STORAGE,
 HOWEVER, THERE ARE NO STORAGE DETAILS.
  
 PLEASE PROVIDE ALL APPLICABLE DETAILS RELATED TO
 STORAGE INCULDING AISLE/FLOOR LAYOUT, RACKS, INCLUDING
 PALLET TYPES, COMMODITY TYPE, WRAPPING TYPES, SHELLVING
 TYPES, HEIGHTS, WEIGHT LIMITS, ETC, FOR REVIEW
 PURPOSES.
  
 ANY PROPOSED RACKS IN THE STORAGE AREA SHALL BE
 INSTALLED UNDER SEPARATE PERMIT AND SHOP DRAWINGS.
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-05-05 Cont ID  
Sent By pvalenti Date 2020-05-05 Time 08:50 Rev Time 0.00
Received By pvalenti Date 2020-04-30 Time 14:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-04-22 Time   Rev Time 0.00
Received By lmarchan Date 2020-04-21 Time 07:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-16 Cont ID  
Sent By shill Date 2020-03-16 Time 06:29 Rev Time 0.00
Received By shill Date 2020-03-09 Time 10:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-01-29 Time   Rev Time 0.00
Received By lmarchan Date 2020-01-13 Time 09:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2020-01-21 Cont ID  
Sent By jwitmer Date 2020-01-21 Time 15:20 Rev Time 0.00
Received By jwitmer Date 2020-01-21 Time 07:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-05-01 Cont ID  
Sent By ccole Date 2020-05-01 Time 14:11 Rev Time 0.00
Received By ccole Date 2020-05-01 Time 07:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-04-21 Cont ID  
Sent By ccole Date 2020-04-21 Time 16:08 Rev Time 0.00
Received By ccole Date 2020-04-21 Time 09:37 Sent To  
Notes
2020-04-21 16:12:203RD REVIEW FBC-2017 MECHANICAL
 PERMIT #19120803
 4/21/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS #1, 2, & 3 FROM THE 1ST AND 2ND REVIEW LISTED
 BELOW HAVE NOT BEEN COMPLETELY ADDRESSED. PLEASE PAY
 ATTENTION TO THE REMARKS BELOW THE COMMENTS IN
 CAPITALIZED LETTERS.
  
 1) SHEET M2.1: THE PLANS APPEAR TO INDICATE A NEW SHOP
 HOWEVER IT IS NOT CLEAR AS TO WHAT TYPE OF SHOP AND
 PROCESSES WILL OCCUR, WHAT PRODUCTS WILL BE FABRICATED.
 PLEASE PROVIDE A BRIEF NARRATIVE TO CLARIFY AND REFER
 TO SECTION 511 FBC M- COMPLETE PLANS AND DETAILS FOR A
 DUST COLLECTION SYSTEM ARE REQUIRED FOR WOODWORKING
 SHOPS.
 IN RESPONSE TO THE ABOVE COMMENT, THE LETTER FROM
 SCHMIDT NICHOLS TO PLANNING AND ZONING WAS SUBMITTED.
 IN PARAGRAPH 2 OF THE LETTER THE STATED USE OF THE
 SPACE IS FOR "ROOF BUILDER CONTRACTOR OPERATIONS". THIS
 STATEMENT DOES NOT CLARIFY WHAT PROCESSES WILL OCCUR IN
 THE SHOP AND WHAT MATERIALS- WOOD, METAL-PLASTICS,
 FIBERGLASS ETC.- WILL BE USED IN THOSE PROCESSES. AS
 STATED ABOVE A DUST COLLECTION SYSTEM MAY BE REQUIRED.
 THE LETTER ALSO INDICATES VEHICLE STORAGE INSIDE THE
 BUILDING.
  
 2) M6.1: CONCERNING THE EXHAUST VENTILATION SYSTEM,
 EF-4 AND IT'S SEQUENCING SHALL COMPLY WITH SECTIONS
 503.1 & 503.2 FBC M. PLEASE COMPLY AND PROVIDE
 MANUFACTURER'S SPECIFICATIONS FOR THE FAN.
  
 503.1: MOTORS AND FANS SHALL BE SIZED TO PROVIDE THE
 REQUIRED AIR MOVEMENT. MOTORS IN AREAS THAT CONTAIN
 FLAMMABLE VAPORS OR DUSTS SHALL BE OF A TYPE APPROVED
 FOR SUCH ENVIRONMENTS. A MANUALLY OPERATED REMOTE
 CONTROL INSTALLED AT AN APPROVED LOCATION SHALL BE
 PROVIDED TO SHUT OFF FANS OR BLOWERS IN FLAMMABLE VAPOR
 OR DUST SYSTEMS. ELECTRICAL EQUIPMENT AND APPLIANCES
 USED IN OPERATIONS THAT GENERATE EXPLOSIVE OR FLAMMABLE
 VAPORS, FUMES OR DUSTS SHALL BE INTERLOCKED WITH THE
 VENTILATION SYSTEM SO THAT THE EQUIPMENT AND APPLIANCES
 CANNOT BE OPERATED UNLESS THE VENTILATION FANS ARE IN
 OPERATION. MOTORS FOR FANS USED TO CONVEY FLAMMABLE
 VAPORS OR DUSTS SHALL BE LOCATED OUTSIDE THE DUCT OR
 SHALL BE PROTECTED WITH APPROVED SHIELDS AND
 DUSTPROOFING. MOTORS AND FANS SHALL BE PROVIDED WITH A
 MEANS OF ACCESS FOR SERVICING AND MAINTENANCE.
 503.2: PARTS OF FANS IN CONTACT WITH EXPLOSIVE OR
 FLAMMABLE VAPORS, FUMES OR DUSTS SHALL BE OF NONFERROUS
 OR NONSPARKING MATERIALS, OR THEIR CASING SHALL BE
 LINED OR CONSTRUCTED OF SUCH MATERIAL. WHERE THE SIZE
 AND HARDNESS OF MATERIALS PASSING THROUGH A FAN ARE
 CAPABLE OF PRODUCING A SPARK, BOTH THE FAN AND THE
 CASING SHALL BE OF NONSPARKING MATERIALS. WHERE FANS
 ARE REQUIRED TO BE SPARK RESISTANT, THEIR BEARINGS
 SHALL NOT BE WITHIN THE AIRSTREAM, AND ALL PARTS OF THE
 FAN SHALL BE GROUNDED. FANS IN SYSTEMS-HANDLING
 MATERIALS THAT ARE CAPABLE OF CLOGGING THE BLADES, AND
 FANS IN BUFFING OR WOODWORKING EXHAUST SYSTEMS, SHALL
 BE OF THE RADIAL-BLADE OR TUBE-AXIAL TYPE.
 SHEET M6.1: THE NOTES UNDER THE EF-4 SCHEDULE STATE
 THAT THE FAN AND MOTOR SHALL COMPLY WITH SECTIONS 503.1
 AND 503.2 PLEASE SHOW THE LOCATION OF THE MANUALLY
 OPERATED REMOTE CONTROL SWITCH AND PROVIDE THE SEQUENCE
 OF OPERATION FOR THE FAN.
  
 3) M2.1: THE PLANS SHOW A GARAGE DOOR POSSIBLY FOR
 LOADING AND UNLOADING OF MATERIALS, PRODUCTS, ETC.
 PLEASE INDICATE IF MOTOR VEHICLES WILL ENTER INTO, OR
 BE STORED IN THE BUILDING, AND REFER TO TABLE 403.3.1.1
 AND SECTION 404.1 FOR EXHAUST VENTILATION SYSTEM
 REQUIREMENTS.
 ACCORDING TO THE LETTER FROM SCHMIDT NICHOLS, THERE
 WILL BE VEHICLE STORAGE IN THE BUILDING. PLEASE PROVIDE
 AN EXHAUST VENTILATION SYSTEM IN THE AREAS OF VEHICLE
 STORAGE PER SECTION 404.1 AS NOTED ABOVE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-03-11 Cont ID  
Sent By ccole Date 2020-03-11 Time 12:20 Rev Time 0.00
Received By ccole Date 2020-03-11 Time 11:18 Sent To  
Notes
2020-03-11 12:39:502ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19120803
 3/11/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS FROM THE 1ST REVIEW LISTED BELOW HAVE NOT BEEN
 COMPLETELY ADDRESSED.
  
 1) SHEET M2.1: THE PLANS APPEAR TO INDICATE A NEW SHOP
 HOWEVER IT IS NOT CLEAR AS TO WHAT TYPE OF SHOP AND
 PROCESSES WILL OCCUR, WHAT PRODUCTS WILL BE FABRICATED.
 PLEASE PROVIDE A BRIEF NARRATIVE TO CLARIFY AND REFER
 TO SECTION 511 FBC M- COMPLETE PLANS AND DETAILS FOR A
 DUST COLLECTION SYSTEM ARE REQUIRED FOR WOODWORKING
 SHOPS.
 2ND REQUEST TO PROVIDE A BRIEF NARRATIVE ON THE PLANS.
 THE ARCHITECT'S RESPONSE NARRATIVE TO THIS COMMENT
 INDICATES THERE IS AN APPROVAL LETTER SUBMITTED FROM
 SCHMIDT NICHOLS? THE LETTER WAS NOT SUBMITTED. AND IS
 NOT CLEAR WHO SCHMIDT NICHOLS IS.
  
 2) M6.1: CONCERNING THE EXHAUST VENTILATION SYSTEM,
 EF-4 AND IT'S SEQUENCING SHALL COMPLY WITH SECTIONS
 503.1 & 503.2 FBC M. PLEASE COMPLY AND PROVIDE
 MANUFACTURER'S SPECIFICATIONS FOR THE FAN.
  
 503.1: MOTORS AND FANS SHALL BE SIZED TO PROVIDE THE
 REQUIRED AIR MOVEMENT. MOTORS IN AREAS THAT CONTAIN
 FLAMMABLE VAPORS OR DUSTS SHALL BE OF A TYPE APPROVED
 FOR SUCH ENVIRONMENTS. A MANUALLY OPERATED REMOTE
 CONTROL INSTALLED AT AN APPROVED LOCATION SHALL BE
 PROVIDED TO SHUT OFF FANS OR BLOWERS IN FLAMMABLE VAPOR
 OR DUST SYSTEMS. ELECTRICAL EQUIPMENT AND APPLIANCES
 USED IN OPERATIONS THAT GENERATE EXPLOSIVE OR FLAMMABLE
 VAPORS, FUMES OR DUSTS SHALL BE INTERLOCKED WITH THE
 VENTILATION SYSTEM SO THAT THE EQUIPMENT AND APPLIANCES
 CANNOT BE OPERATED UNLESS THE VENTILATION FANS ARE IN
 OPERATION. MOTORS FOR FANS USED TO CONVEY FLAMMABLE
 VAPORS OR DUSTS SHALL BE LOCATED OUTSIDE THE DUCT OR
 SHALL BE PROTECTED WITH APPROVED SHIELDS AND
 DUSTPROOFING. MOTORS AND FANS SHALL BE PROVIDED WITH A
 MEANS OF ACCESS FOR SERVICING AND MAINTENANCE.
  
 503.2: PARTS OF FANS IN CONTACT WITH EXPLOSIVE OR
 FLAMMABLE VAPORS, FUMES OR DUSTS SHALL BE OF NONFERROUS
 OR NONSPARKING MATERIALS, OR THEIR CASING SHALL BE
 LINED OR CONSTRUCTED OF SUCH MATERIAL. WHERE THE SIZE
 AND HARDNESS OF MATERIALS PASSING THROUGH A FAN ARE
 CAPABLE OF PRODUCING A SPARK, BOTH THE FAN AND THE
 CASING SHALL BE OF NONSPARKING MATERIALS. WHERE FANS
 ARE REQUIRED TO BE SPARK RESISTANT, THEIR BEARINGS
 SHALL NOT BE WITHIN THE AIRSTREAM, AND ALL PARTS OF THE
 FAN SHALL BE GROUNDED. FANS IN SYSTEMS-HANDLING
 MATERIALS THAT ARE CAPABLE OF CLOGGING THE BLADES, AND
 FANS IN BUFFING OR WOODWORKING EXHAUST SYSTEMS, SHALL
 BE OF THE RADIAL-BLADE OR TUBE-AXIAL TYPE.
 SHEET M6.1: THE NOTES UNDER THE EF-4 SCHEDULE STATE
 THAT THE FAN AND MOTOR SHALL COMPLY WITH SECTIONS 503.1
 AND 503.2 PLEASE SHOW THE LOCATION OF THE MANUALLY
 OPERATED REMOTE CONTROL SWITCH, AND PROVIDE THE
 SEQUENCE OF OPERATION FOR THE FAN.
  
 3) M2.1: THE PLANS SHOW A GARAGE DOOR POSSIBLY FOR
 LOADING AND UNLOADING OF MATERIALS, PRODUCTS, ETC.
 PLEASE INDICATE IF MOTOR VEHICLES WILL ENTER INTO, OR
 BE STORED IN THE BUILDING, AND REFER TO TABLE 403.3.1.1
 AND SECTION 404.1 FOR EXHAUST VENTILATION SYSTEM
 REQUIERMENTS.
 M2.1: PLEASE PROVIDE A NOTE ON THE PLAN TO INDICATE NO
 VEHICLE STORAGE PERMITTED.
  
 4) THE $15,000 JOB VALUE IS VERY LOW FOR THE SCOPE OF
 THE PROJECT. TOTAL VALUE SHALL INCLUDE THE COSTS OF
 LABOR, MATERIALS, EQUIPMENT, APPLIACES, FIXTURES ETC.
 FOR ALL TRADES INCLUDING STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, AND SHALL ALSO INCLUDE ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, AND OVERHEAD AND PROFIT.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS- SECTION 109.3 WPB.
 COMMENT WAS NOT ADDRESSED.
  
 5) PROVIDE THE CORRECT ADDRESS ON PAGE 2 OF THE
 ENERGYGAUGE COMPLIANCE REPORT. PLEASE NOTE THAT THE
 ADDRESS ON THE APPLICATION, THE PLANS, AND THE ENERGY
 FORM DO NOT MATCH- SECTION 105.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-29 Cont ID  
Sent By ccole Date 2020-01-29 Time 12:25 Rev Time 0.00
Received By ccole Date 2020-01-29 Time 09:24 Sent To  
Notes
2020-01-29 13:35:591ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120803
 1/29/20.
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M2.1: THE PLANS APPEAR TO INDICATE A NEW SHOP
 HOWEVER IT IS NOT CLEAR AS TO WHAT TYPE OF SHOP AND
 PROCESSES WILL OCCUR, WHAT PRODUCTS WILL BE FABRICATED.
 PLEASE PROVIDE A BRIEF NARRATIVE TO CLARIFY AND REFER
 TO SECTION 511 FBC M- COMPLETE PLANS AND DETAILS FOR A
 DUST COLLECTION SYSTEM ARE REQUIRED FOR WOODWORKING
 SHOPS.
  
 2) M6.1: CONCERNING THE EXHAUST VENTILATION SYSTEM,
 EF-4 AND IT'S SEQUENCING SHALL COMPLY WITH SECTIONS
 503.1 & 503.2 FBC M. PLEASE COMPLY AND PROVIDE
 MANUFACTURER'S SPECIFICATIONS FOR THE FAN.
  
 503.1: MOTORS AND FANS SHALL BE SIZED TO PROVIDE THE
 REQUIRED AIR MOVEMENT. MOTORS IN AREAS THAT CONTAIN
 FLAMMABLE VAPORS OR DUSTS SHALL BE OF A TYPE APPROVED
 FOR SUCH ENVIRONMENTS. A MANUALLY OPERATED REMOTE
 CONTROL INSTALLED AT AN APPROVED LOCATION SHALL BE
 PROVIDED TO SHUT OFF FANS OR BLOWERS IN FLAMMABLE VAPOR
 OR DUST SYSTEMS. ELECTRICAL EQUIPMENT AND APPLIANCES
 USED IN OPERATIONS THAT GENERATE EXPLOSIVE OR FLAMMABLE
 VAPORS, FUMES OR DUSTS SHALL BE INTERLOCKED WITH THE
 VENTILATION SYSTEM SO THAT THE EQUIPMENT AND APPLIANCES
 CANNOT BE OPERATED UNLESS THE VENTILATION FANS ARE IN
 OPERATION. MOTORS FOR FANS USED TO CONVEY FLAMMABLE
 VAPORS OR DUSTS SHALL BE LOCATED OUTSIDE THE DUCT OR
 SHALL BE PROTECTED WITH APPROVED SHIELDS AND
 DUSTPROOFING. MOTORS AND FANS SHALL BE PROVIDED WITH A
 MEANS OF ACCESS FOR SERVICING AND MAINTENANCE.
  
 503.2: PARTS OF FANS IN CONTACT WITH EXPLOSIVE OR
 FLAMMABLE VAPORS, FUMES OR DUSTS SHALL BE OF NONFERROUS
 OR NONSPARKING MATERIALS, OR THEIR CASING SHALL BE
 LINED OR CONSTRUCTED OF SUCH MATERIAL. WHERE THE SIZE
 AND HARDNESS OF MATERIALS PASSING THROUGH A FAN ARE
 CAPABLE OF PRODUCING A SPARK, BOTH THE FAN AND THE
 CASING SHALL BE OF NONSPARKING MATERIALS. WHERE FANS
 ARE REQUIRED TO BE SPARK RESISTANT, THEIR BEARINGS
 SHALL NOT BE WITHIN THE AIRSTREAM, AND ALL PARTS OF THE
 FAN SHALL BE GROUNDED. FANS IN SYSTEMS-HANDLING
 MATERIALS THAT ARE CAPABLE OF CLOGGING THE BLADES, AND
 FANS IN BUFFING OR WOODWORKING EXHAUST SYSTEMS, SHALL
 BE OF THE RADIAL-BLADE OR TUBE-AXIAL TYPE.
  
 3) M2.1: THE PLANS SHOW A GARAGE DOOR POSSIBLY FOR
 LOADING AND UNLOADING OF MATERIALS, PRODUCTS, ETC.
 PLEASE INDICATE IF MOTOR VEHICLES WILL ENTER INTO, OR
 BE STORED IN THE BUILDING, AND REFER TO TABLE 403.3.1.1
 AND SECTION 404.1 FOR EXHAUST VENTILATION SYSTEM
 REQUIERMENTS.
  
 4) THE $15,000 JOB VALUE IS VERY LOW FOR THE SCOPE OF
 THE PROJECT. TOTAL VALUE SHALL INCLUDE THE COSTS OF
 LABOR, MATERIALS, EQUIPMENT, APPLIACES, FIXTURES ETC.
 FOR ALL TRADES INCLUDING STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, AND SHALL ALSO INCLUDE ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, AND OVERHEAD AND PROFIT.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS- SECTION 109.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2020-05-01 Cont ID  
Sent By ccole Date 2020-05-01 Time 09:56 Rev Time 0.00
Received By ccole Date 2020-05-01 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2020-04-22 Cont ID  
Sent By ccole Date 2020-04-22 Time 08:57 Rev Time 0.00
Received By ccole Date 2020-04-21 Time 16:14 Sent To  
Notes
2020-04-22 08:57:293RD REVIEW FBC-2017 PLUMBING
 PERMIT #19120803
 4/21/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A4.0: THE DOOR FOR THE MEN'S TOILET ROOM
 CANNOT BE REMOVED UNLESS AN ACCESSIBLE TOILET
 COMPARTMENT IS INSTALLED IN THE ROOM- SEE SECTION
 405.3.4 EXCEPTION 1 FBC P. PLEASE NOTE THAT THE
 OUTSWING DOOR THAT WAS REMOVED CAN INSWING INTO THE
 ROOM PROVIDING THE ARC OF THE DOOR COMPLIANT WITH
 SECTION 602.3.2 (2) FBC ACC.
  
 2) A4.6, DETAIL 8: THE KNEE CLEARANCE MUST EXTEND
 MINIMUM OF 8" DEEP AT 27" ABOVE THE FINISH FLOOR-
 SECTION 306.3.3 FBC ACC.
  
 3) A4.6, DETAIL 2: PROVIDE THE SHOWER GRAB LENGTHS-
 SECTION 608.3.1 AND THEIR HEIGHTS- 609.4 FBC ACC.
  
 4) A4.6, DETAIL 2: PROVIDE L-SHAPE SEAT EXTENT AND
 REQUIRED CLEARANCES PER FIGURES 610.3 AND 610.3.1 FBC
 ACC.
  
 5) P0.1 & P3.1: REFER TO COMMENT #9 FROM THE 2ND REVIEW
 AND SHOW THE CORRECT LOCATION OF THE SHUT OFF VALVE AT
 THE TOP OF THE DOWN FEED WATER PIPE TO THE WATER
 HEATER- SECTION 606.1 (5)- FBC P.
  
 6) P0.1 & P3.1: VERIFY THE RECIRCULATION PUMP IS
 EQUIPPED WITH CONTROLS THAT WILL TURN OFF THE PUMP WHEN
 THE WATER IN THE CIRCULATION LOOP HAS REACHED THE
 DESIRED TEMPERATURE, AND WHEN THERE IS NO DEMAND FOR
 HOT WATER- SECTION C404.6.1 FBC EC.
  
 7) P0.1 & P3.1: TEMPERED WATER SHALL BE DELIVERED FROM
 THE LAVATORIES THOUGH AN APPROVED TEMPERATURE LIMITING
 DEVICE THAT CONFORMS TO ASSE 1070 OR CSA B125- SECTION
 416.5 FBC P. THE MAXIMUM TEMPERATURE SHALL BE 110
 DEGREES F- SECTION 607.1.2. PLEASE SHOW THE LOCATIONS
 OF THE DEVICES ON THE DRAWINGS.
  
 8) P0.1 & P3.1: PROVIDE PIPE INSULATION SPECIFICATIONS-
 TABLE C403.2.10 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM..
  
 CHRISTOPHER L. COLE
 MECHANICAL/ PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-03-16 Cont ID  
Sent By shill Date 2020-03-16 Time 06:28 Rev Time 0.00
Received By shill Date 2020-03-09 Time 17:59 Sent To  
Notes
2020-03-16 06:28:52PLUMBING 2ND REVIEW**DENIED**BUILDING A**19120803
  
  
 1) WHERE PLUMBING FIXTURES ARE REQUIRED, SEPARATE
 FACILITIES SHALL BE PROVIDED FOR EACH SEX. FBC-PLB
 403.2. SHT. P2.1 AND P3.1 CALL OUT BOTH TOILET ROOMS
 ARE MEN.
 2) THE SHOWER CLEAR FLOOR SPACE SHALL NOT HAVE A DOOR
 THAT SWINGS INTO IT. FBC-ACC 603.2.3
 3) SHOWER IS MISSING ON THE SANITARY ISOMETRIC DRAWING
 SHT. P2.1
 4) SHT. A4.3 SHOW TOILET CLEAR FLOOR SPACE AS 56? AND
 THAT WOULD BE CORRECT IF THE TOILET WAS WALL MOUNT.
 SHT. P.01UNDER PLUMBING FIXTURE SCHEDULE CALLS OUT
 FLOOR MOUNTED TOILET WHICH WOULD REQUIRED 59? CLEAR
 FLOOR SPACE COMPLYING WITH FBC-ACC 604.8.1.1. PLEASE
 CLARIFY FBC 107.2.1
 5) SHT. A 4.3 PLEASE SHOW THE MOUNTING OF THE MIRROR AS
 40? MAX TO THE REFLECTIVE SURFACE. FBC-ACC 603.3
 6) I WAS UNABLE TO LOCATE THE REQUIRED SERVICE SINK.
 FBC-PLB 403.1
 7) PROVIDE THE SHOWER VALVE AND HANDHELD DETAIL SHOWING
 MAX 48? TO THE GRIPPING SURFACE OF BOTH. FBC -ACC
 608.5.1
 8) SHT. A4.6 SHOW THE SHOWER AS 36? ABSOLUTE AND NOT A
 MAX. FBC-ACC 608.2.1\
 9) PROVIDE THE REQUIRED SHUT OFF VALVE ON THE WATER
 HEATER DETAIL AND WATER ISOMETRIC. ALL DOWN FEED LINES
 SHALL HAVE A SHUT OFF VALVE AND BEFORE THE EXPANSION
 TANK. FBC-PLB 606.1
  
 TIM HUNT
 PLUMBING PLAN REVIEW
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 561-248-2703
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-27 Cont ID  
Sent By gjohnson Date 2020-01-27 Time 17:16 Rev Time 0.00
Received By gjohnson Date 2020-01-27 Time 12:10 Sent To  
Notes
2020-01-27 17:17:101ST REVIEW:19120803
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. DRINKING FOUNTAIN IS REQUIRED . FBC PL TABLE 403.1
 2017 FBC-ACCESSIBILITY CODE SECTION 211.2 MINIMUM
 NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE
 PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1
 THROUGH 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY
 WITH 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 2. 2017 FBC-ACCESSIBILITY CODE SECTION 602.1 DRINKING
 FOUNTAINS SHALL COMPLY WITH 307. PROTRUDING OBJECTS.
  
 3. PLEASE NOTE ON SHEET A-4.3 THE PLAN MAKES REFERENCE
 TO THE GOVERNING CODE ADAAG. THE DEPARTMENT OF JUSTICE
 HAS BLESSED THE 2017 FBC-ACCESSIBILITY CODE. THE INTENT
 AS ESTABLISHED BY S.553.502, FLORIDA STATUTES, IS TO
 MAINTAIN THE US DEPARTMENT OF JUSTICE CERTIFICATION OF
 THE CODE AS SUBSTANTIALLY EQUIVALENT TO THE ADA
 STANDARDS SO COMPLIANCE WITH THE CODE PROVIDES
 PRESUMPTION OF COMPLIANCE WITH THE ADA STANDARDS.
  
 4. DETAIL # 2 GRAB BARS ARE TO COMPLY WITH: 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 5. DETAIL # 2, THE TOILET PAPER HOLDER TO COMPLY WITH:
 2017 FBC-ACCESS. CODE 604.7 DISPENSERS. TOILET PAPER
 DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE 7
 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE
 WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 6. PROVIDE DETAIL FOR THE TRANSFER SHOWER SHOW THE
 FOLLOWING PER FBC ACC
 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS. TRANSFER
 TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES BY 36
 INCHES CLEAR INSIDE DIMENSIONS MEASURED AT THE CENTER
 POINTS OF OPPOSING SIDES AND SHALL HAVE A 36 INCH WIDE
 MINIMUM ENTRY ON THE FACE OF THE SHOWER COMPARTMENT.
 CLEARANCE OF 36 INCHES WIDE MINIMUM BY 48 INCHES LONG
 MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE
 PROVIDED.
 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN TRANSFER
 TYPE COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ACROSS
 THE CONTROL WALL AND BACK WALL TO A POINT 18 INCHES
 FROM THE CONTROL WALL.
 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. IN TRANSFER
 TYPE SHOWER COMPARTMENTS, THE CONTROLS, FAUCETS, AND
 SHOWER SPRAY UNIT SHALL BE INSTALLED ON THE SIDE WALL
 OPPOSITE THE SEAT 38 INCHES MINIMUM AND 48 INCHES
 MAXIMUM ABOVE THE SHOWER FLOOR AND SHALL BE LOCATED ON
 THE CONTROL WALL 15 INCHES MAXIMUM FROM THE CENTERLINE
 OF THE SEAT TOWARD THE SHOWER OPENING.
 608.4 SEATS. A FOLDING OR NON-FOLDING SEAT SHALL BE
 PROVIDED IN TRANSFER TYPE SHOWER COMPARTMENTS. A
 FOLDING SEAT SHALL BE PROVIDED IN ROLL-IN TYPE SHOWERS
 REQUIRED IN TRANSIENT LODGING GUEST ROOMS WITH MOBILITY
 FEATURES COMPLYING WITH 806.2. SEATS SHALL COMPLY WITH
 610.
 608.6 SHOWER SPRAY UNIT AND WATER.A SHOWER SPRAY UNIT
 WITH A HOSE 59 INCHES (1500 MM) LONG MINIMUM THAT CAN
 BE USED BOTH AS A FIXED-POSITION SHOWER HEAD AND AS A
 HAND-HELD SHOWER SHALL BE PROVIDED. THE SHOWER SPRAY
 UNIT SHALL HAVE AN ON/OFF CONTROL WITH A NON-POSITIVE
 SHUT-OFF. IF AN ADJUSTABLE-HEIGHT SHOWER HEAD ON A
 VERTICAL BAR IS USED, THE BAR SHALL BE INSTALLED SO AS
 NOT TO OBSTRUCT THE USE OF GRAB BARS. SHOWER SPRAY
 UNITS SHALL DELIVER WATER THAT IS 120?F (49?C) MAXIMUM.
 EXCEPTION: A FIXED SHOWER HEAD LOCATED AT 48 INCHES
 (1220 MM) MAXIMUM ABOVE THE SHOWER FINISH FLOOR SHALL
 BE PERMITTED INSTEAD OF A HAND-HELD SPRAY UNIT IN
 FACILITIES THAT ARE NOT MEDICAL CARE FACILITIES,
 LONG-TERM CARE FACILITIES, TRANSIENT LODGING GUEST
 ROOMS, OR RESIDENTIAL DWELLING UNITS.
 608.7 THRESHOLDS. THRESHOLDS IN ROLL-IN TYPE SHOWER
 COMPARTMENTS SHALL BE 1/2 INCH (13 MM) HIGH MAXIMUM IN
 ACCORDANCE WITH 303. IN TRANSFER TYPE SHOWER
 COMPARTMENTS, THRESHOLDS 1/2 INCH (13 MM) HIGH MAXIMUM
 SHALL BE BEVELED, ROUNDED, OR VERTICAL.
 EXCEPTION: A THRESHOLD 2 INCHES (51 MM) HIGH MAXIMUM
 SHALL BE PERMITTED IN TRANSFER TYPE SHOWER COMPARTMENTS
 IN EXISTING FACILITIES WHERE PROVISION OF A 1/2 INCH
 (13 MM) HIGH THRESHOLD WOULD DISTURB THE STRUCTURAL
 REINFORCEMENT OF THE FLOOR SLAB.
  
 7. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC 212.2
 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
 606.3 HEIGHT.LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
 606.4 FAUCETS. CONTROLS FOR FAUCETS SHALL COMPLY WITH
 309. HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN
 FOR 10 SECONDS MINIMUM
  
 8. PLEASE PROVIDE SIZING CALCULATIONS FOR THE ROOF
 DRAINAGE PER FBC PL 1106
  
 9. OVERFLOW OR EMERGENCY ROOF DRAINS MAYBE REQUIRED IF
 PONDING WILL OCCUR ON THE ROOF IF THE MAIN ROOF
 DRAINAGE SYSTEM BECOMES CLOGGED. PER FBC PL 1106
  
 10. P3-1 THE NOTE ON THE WATER ISOMETRIC REFERS TO THE
 CIVIL PLAN I COULD NOT LOCATE ANY CIVIL PLANS PLEASE
 CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 11. SHT A4-3 DETAIL #4 THE CLEAR FLOOR SPACE FOR THE
 WATER FOUNTAIN SHALL BE FOR A FORWARD APPROACH. PER FBC
 ACC 602.2
  
 12. THE ENERGY CALCULATIONS PAGE 7 OF 20 SHOWS THE
 WATER HEATER WITH THE EFF RATING OF .92 IT SHALL BE .98
 PER FBC ENG TABLE C404.2
  
 13.THE DOORS ENTERING THE SHOWER ROOM ARE NOT PERMITTED
 TO SWING INTO THE SPACE. PER FBC ACC 603.2.3 DOOR
 SWING.DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE
 OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
 EXCEPTIONS:
 2.WHERE THE TOILET ROOM OR BATHING ROOM IS FOR
 INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
 FIXTURE.
  
 14. SHT P2-1 THE BRANCH OF THE BUILDING DRAIN WITH THE
 BATHROOM GROUP , EYE WASH AND MOP SINK SHALL CONNECT TO
 MAIN BUILDING DRAIN DOWN STREAM OF THE OTHER BATHROOM
 GROUP. PER FBC PL 912.1
  
 15.SHT P3-1 LABEL THE HOT AND COLD LINES ON THE
 ISOMETRIC DRAWING. PER WPB AMEND TO FBC 107.2.1
 ADDITIONAL INFORMATION REQUIRED.
  
 16. PLACE NOT ON PLAN BACKFLOW REQUIRED ON ICE
 MACHINES, COFFEE MAKER OR ANY OTHER APPLIANCES
 CONNECTED TO THE POTABLE WATER SYSTEMS WITH NO AIR GAP.
 PER FBC PL 608.3
  
 17. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5
  
 END OF COMMENTS
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-05-04 Cont ID  
Sent By medwards Date 2020-05-04 Time 08:09 Rev Time 0.00
Received By medwards Date 2020-05-04 Time 14:59 Sent To  
Notes
2020-05-04 15:01:13APPROVED BASED ON PATRICK GRAHAM WILL SUBMIT THE 2
 SHEETS THAT DO NOT HAVE THE SIGNATURE OR SEAL AFTER
 THIS CYCLE CLOSES.
2020-05-04 08:09:47SHEET A5.0 V3, SHEET M6.1 ARE MISSING DIGITAL
 SIGNATURES AND SEALS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
2020-05-01 14:13:02MECHANICAL AND PLUMBING SHEETS OK- CCOLE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-04-21 Cont ID  
Sent By pvalenti Date 2020-04-21 Time 15:29 Rev Time 0.00
Received By pvalenti Date 2020-04-21 Time 15:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-03-09 Cont ID  
Sent By shill Date 2020-03-09 Time 18:14 Rev Time 0.00
Received By shill Date 2020-03-09 Time 18:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-01-28 Cont ID  
Sent By shill Date 2020-01-28 Time 19:11 Rev Time 0.00
Received By shill Date 2020-01-28 Time 19:11 Sent To  
Notes
2020-01-21 15:21:271/21/2020. ARCHITECTURAL AND STRUCTURAL SHEETS CHECKED
 FOR ELECTRONIC SIGNATURE, OK. JW

Review Stop Z ZONING
Rev No 4 Status P Date 2020-05-04 Cont ID  
Sent By awooten Date 2020-05-04 Time   Rev Time 0.00
Received By awooten Date 2020-05-04 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2020-04-21 Cont ID  
Sent By awooten Date 2020-04-21 Time   Rev Time 0.00
Received By awooten Date 2020-04-21 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-11 Cont ID  
Sent By awooten Date 2020-03-11 Time   Rev Time 0.00
Received By awooten Date 2020-03-11 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-01-21 Cont ID  
Sent By awooten Date 2020-01-21 Time   Rev Time  
Received By awooten Date 2020-01-21 Time   Sent To  
Notes
2020-01-21 14:15:57****************************************ZONING REVIEW
 FAILED*******************************
  
 PROVIDE A COPY OF THE SURVEY.
  
 FURTHER COMMENTS MAY FOLLOW ADDITIONAL REVIEW.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]