Plan Review Details - Permit 19120788
Plan Review Stops For Permit 19120788
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-02-14 Cont ID  
Sent By skennedy Date 2020-02-14 Time 11:10 Rev Time 0.00
Received By skennedy Date 2020-02-14 Time 11:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-02-10 Cont ID  
Sent By rmcphers Date 2020-02-10 Time 14:21 Rev Time 0.00
Received By rmcphers Date 2020-02-10 Time 12:31 Sent To  
Notes
2020-02-10 14:21:01SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE WIND DESIGN CRITERIA (WIND SPEED)
 USED FOR THE DESIGN PER FBC R301.2.1
 2) ENERGY FORM R402 NEEDS TO BE SIGNED BY THE OWNER IN
 THE SPACE PROVIDED ON THE FORM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By dbattles Date 2020-01-16 Time 10:13 Rev Time 0.00
Received By dbattles Date 2020-01-15 Time 15:23 Sent To  
Notes
2020-01-16 10:13:25BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19120788
 REVIEWED: JANUARY 16, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) PLEASE ADD EXISTING SQ FOOTAGE OF STRUCTURE, SQ.
 FOOTAGE PROPOSED AND TOTAL NEW SQ. FOOTAGE.
 - THIS DATA IS NEEDED FOR IMPACT REVIEW. EXISTING SQ.
 FOOTAGE CAN BE OBTAINED FROM PROPERTY APPRAISER
 WEBSITE.
  
 2) 401.2 FBC[RE] PROVIDE ENERGY CALCULATIONS TO MEET
 REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. CHOOSE
 METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
 - IF USING PRESCRIPTIVE FOR ENERGY CODES PLEASE STATE
 THAT ON PLANS AND STATE THE SHGC FOR THE WINDOWS AND
 SLIDER. (SEE TABLE R402.1.2). CLIMATE ZONE = 1
  
 3) ADD NOTE THAT ROOF IS EXISTING AND WILL REMAIN.
 - I CAN REMOVE ROOFING REVIEW IF ROOF IS REMAINING.
  
 4) 318 FBC[R] INDICATE THE MEANS OF TERMITE PROTECTION
 PROPOSED AND REFERENCE SECTION R308 FOR STANDARDS.
 - ADD NOTE AS TO HOW TERMITE PROTECTION WILL BE
 PROVIDED.
  
 5) 403.4 FBC[R] EXTERIOR FOOTINGS SHALL BE PLACED NOT
 LESS THAN 12 INCHES BELOW THE UNDISTURBED GROUND
 SURFACE. WHERE APPLICABLE, THE DEPTH OF FOOTINGS SHALL
 ALSO CONFORM TO SECTIONS R403.1.4.1 THROUGH R403.1.4.2.
 - I CANNOT TELL WHAT SUPPORTS THE NEW IN-FILL WALLS
 WINDOWS AND SLIDERS OTHER THAN EXISTING SLAB.. WITH
 INCREASE IN LOAD AND LOADS BEING APPLIED TO CORNER,
 FURTHER DETAILS WOULD BE NEEDED TO SHOW HOW IT IS
 STRUCTURALLY ABLE TO HANDLE THE INCREASES.
  
 6) ASCE 7-10 26.7.1 WIND EXPOSURE CATEGORY.
 - PLEASE PROVIDE WIND EXPOSURE CATEGORY. THIS WOULD BE
 CATEGORY C.
  
 7) 317.19(5) FBC[R] WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING HAVING A
 CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE
 GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED
 VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO
 SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE
 WEATHER.
 - CHECK SHEATHING DISTANCE FROM GRADE TO SEE IF IT
 SHOULD BE TREATED.
  
 8) R403.1.6 FOUNDATION ANCHORAGE. WOOD SILL PLATES AND
 WOOD WALLS SUPPORTED DIRECTLY ON CONTINUOUS FOUNDATIONS
 SHALL BE ANCHORED TO THE FOUNDATION IN ACCORDANCE WITH
 THIS SECTION.
 - WOOD SOLE PLATES AT ALL EXTERIOR WALLS ON MONOLITHIC
 SLABS, WOOD SOLE PLATES OF BRACED WALL PANELS AT
 BUILDING INTERIORS ON MONOLITHIC SLABS AND ALL WOOD
 SILL PLATES SHALL BE ANCHORED TO THE FOUNDATION WITH
 MINIMUM 1/2-INCHDIAMETER (12.7 MM) ANCHOR BOLTS SPACED
 A MAXIMUM OF 6 FEET (1829 MM) ON CENTER OR APPROVED
 ANCHORS OR ANCHOR STRAPS SPACED AS REQUIRED TO PROVIDE
 EQUIVALENT ANCHORAGE TO 1/2-INCH-DIAMETER (12.7 MM)
 ANCHOR BOLTS. BOLTS SHALL EXTEND A MINIMUM OF 7 INCHES
 (178 MM) INTO CONCRETE OR GROUTED CELLS OF CONCRETE
 MASONRY UNITS. THE BOLTS SHALL BE LOCATED IN THE MIDDLE
 THIRD OF THE WIDTH OF THE PLATE. A NUT AND WASHER SHALL
 BE TIGHTENED ON EACH ANCHOR BOLT. THERE SHALL BE A
 MINIMUM OF TWO BOLTS PER PLATE SECTION WITH ONE BOLT
 LOCATED NOT MORE THAN 12 INCHES (305 MM) OR LESS THAN
 SEVEN BOLT DIAMETERS FROM EACH END OF THE PLATE
 SECTION. INTERIOR BEARING WALL SOLE PLATES ON
 MONOLITHIC SLAB FOUNDATION THAT ARE NOT PART OF A
 BRACED WALL PANEL SHALL BE POSITIVELY ANCHORED WITH
 APPROVED FASTENERS. SILL PLATES AND SOLE PLATES SHALL
 BE PROTECTED AGAINST DECAY AND TERMITES WHERE REQUIRED
 BY SECTIONS R317 AND R318.
  
 8A) TYPICAL WALL SECTION STATES ATTACH TOP AND BOTTOM
 WITH SIMPSON SSP. SSP WONT CONNECT TRIPLE SILL PLATE TO
 THE STUD. PLEASE USE STRAP THAT WILL CONNECT ALL WOOD
 MEMBERS AND REVIEW USING ANCHOR BOLTS AT SILL.
 - SINCE YOU MAY NEED MORE CONCRETE BELOW THE SILL, WHY
 HAVE TRIPLE SILL PLATE INSTEAD OF CONCRETE?
  
 8B) PLEASE SHOW CONNECTION OF IN-FILL WALLS TO EXISTING
 WALLS AND COLUMNS.
 - ALSO, PROVIDE NAILING TYPE AND SPACING FOR SHEATHING
 AND LATHE.
  
 9) 703.7.3 FBC[R]WATER-RESISTIVE BARRIERS.
 WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED
 IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED
 SHEATHING, SHALL INCLUDE A WATER-RESISTIVE
 VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST
 EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE
 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH
 THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE
 AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION
 R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE
 BARRIER IS DIRECTED BETWEEN THE LAYERS.
 - 15# FELT WILL ACT AS WATER BARRIER AND PAPER BACKED
 LATHE CAN SERVE AS TYPE D LAYER OVER TOP TO ALLOW
 MOISTURE TO ESCAPE FROM BETWEEN THE 2 LAYERS.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-02-14 Cont ID  
Sent By skennedy Date 2020-02-14 Time 11:11 Rev Time 0.00
Received By skennedy Date 2020-02-14 Time 11:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-01-03 Cont ID  
Sent By jpearson Date 2020-01-03 Time 14:21 Rev Time 0.00
Received By jpearson Date 2020-01-03 Time 09:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-14 Cont ID  
Sent By skennedy Date 2020-02-14 Time 11:18 Rev Time 0.00
Received By skennedy Date 2020-02-03 Time 13:16 Sent To  
Notes
2020-02-04 13:16:34R29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-01-16 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-18 Time 14:56 Sent To  
Notes
2019-12-19 14:56:33R07

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-02-19 Cont ID  
Sent By skennedy Date 2020-02-19 Time 11:59 Rev Time 0.00
Received By skennedy Date 2020-02-14 Time 11:10 Sent To  
Notes
2020-02-14 11:11:03CHECKED OUT A SET OF PLANS TO APPLICANT TO TAKE TO PBCI
 FEE OFFICE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By dbattles Date 2020-01-16 Time 08:20 Rev Time 0.00
Received By dbattles Date 2020-01-15 Time 15:23 Sent To  
Notes
2020-01-16 08:20:41109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-02-12 Cont ID  
Sent By ccole Date 2020-02-12 Time 12:20 Rev Time 0.00
Received By ccole Date 2020-02-12 Time 12:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By ccole Date 2020-01-16 Time 15:25 Rev Time 0.00
Received By ccole Date 2020-01-16 Time 15:25 Sent To I
Notes
2020-01-16 15:36:581ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120788
 1/16/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW SUNROOM IS DEFINED AS AN ADDITON PER SECTION
 R202 FBC EC- ADDITION. AN EXTENSION OR INCREASE IN THE
 CONDITIONED SPACE FLOOR AREA OR HEIGHT OF A BUILDING OR
 STRUCTURE. PROVIDE AN ENERGY COMPLIANCE REPORT IN
 ACCORDANCE WITH SECTIONS R101.5 FBC EC.
  
 2) HEAT IS REQUIRED IN THE NEW SUNROOM PER SECTION
 R303.10 FBC RES. CLARIFY IF A DUCT EXTENSION AND DROP
 WILL BE PROVIDED INTO THE ROOM, OR IF A NEW AC SYSTEM
 WILL BE INSTALLED FOR HEATING AND COOLING- SECTION
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-02-10 Cont ID  
Sent By rmcphers Date 2020-02-10 Time 15:34 Rev Time 0.00
Received By rmcphers Date 2020-02-10 Time 15:34 Sent To  
Notes
2020-02-10 15:35:24THERE IS NO ROOFING FOR THIS PROJECT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By dbattles Date 2020-01-16 Time 10:14 Rev Time 0.00
Received By dbattles Date 2020-01-15 Time 15:23 Sent To  
Notes
2020-01-16 10:14:48SEE BUILDING COMMENT #3.

Review Stop Z ZONING
Rev No 1 Status P Date 2020-01-10 Cont ID  
Sent By llouie Date 2020-01-10 Time   Rev Time  
Received By llouie Date 2020-01-10 Time   Sent To  
Notes
***NONE***