Plan Review Details - Permit 19120656
Plan Review Stops For Permit 19120656
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-09-04 Cont ID  
Sent By cthroop Date 2020-09-04 Time 10:10 Rev Time 0.00
Received By cthroop Date 2020-09-04 Time 09:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-02-28 Cont ID  
Sent By rmcphers Date 2020-02-28 Time 09:06 Rev Time 0.00
Received By rmcphers Date 2020-02-28 Time 08:54 Sent To  
Notes
2020-02-28 09:08:59SFR REMODEL -
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
 CORRECTIONS NEEDED -
 1) JOB COST "VALUE" SHOWN ON THE BUILDING PERMIT
 APPLICATION APPEARS TO BE LOW. PLEASE PROVIDE A COPY OF
 THE CONTRACT SIGNED BY ALL PARTIES TO SHOW THE JOB
 VALUE. JOB "VALUE" SHOWN SHOULD BE ALL LABOR AND ALL
 MATERIALS TO COMPLETE THE JOB.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-09 Cont ID  
Sent By dbattles Date 2020-01-09 Time 14:24 Rev Time 0.00
Received By dbattles Date 2020-01-09 Time 10:06 Sent To  
Notes
2020-01-09 14:30:10109.3 FBC[AMENDED] PROVIDE COPY OF PROPOSAL WITH
 CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN
 ON PERMIT APPLICATION, OR ADJUST VALUE TO MATCH ACTUAL
 COST OF WORK.
 NOTE:
 THIS IS A MASTER PERMIT AND THE VALUE SHOULD INCLUDE
 MECHANICAL, ELECTRICAL, PLUMBING AND BUILDING.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-09-04 Cont ID  
Sent By cthroop Date 2020-09-04 Time 10:10 Rev Time 0.00
Received By cthroop Date 2020-09-04 Time 09:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-02-21 Cont ID  
Sent By jpearson Date 2020-02-21 Time 11:19 Rev Time 0.00
Received By jpearson Date 2020-02-21 Time 11:19 Sent To  
Notes
2020-02-21 11:19:04CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3 (NOT PROVIDED,)
 2. CORRECTED.
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
 6. METER MAIN PANEL SCHEDULE SHOWS A WIRE SIZE OF #0/0
 ON A 200 AMP BREAKER. THIS WIRE SIZE DOES NOT EXIST.
 PLEASE CLARIFY THE WIRE SIZE IS SUFFICIENT FOR THE 200
 AMP BREAKER. ADDITIONALLY, THIS IS SHOWN FEEDING A 150
 AMP PANEL. A 200 AMP FEED CANNOT FEED A PANEL THAT IS
 RATED FOR ONLY 150 AMPS. PROVIDE CLARIFICATIONS AND/OR
 CORRECTIONS AS NEEDED. WPB FBC 107.2.1; NEC
 310.15(B)(16), 408.30 (PANEL SCHEDULE FOR METER MAIN
 STILL SHOWS A 200 AMP BREAKER FEEDING THE INTERIOR
 PANEL. IF THIS IS A 200 AMP BREAKER, THE WIRE WOULD
 NEED TO BE AT LEAST RATED FOR 200 AMPS, AND THE PANEL
 WOULD NEED TO BE RATED FOR AT LEAST 200 AMPS. PROVIDE
 CLARIFIATIONS AND/OR CORRECTIONS AS NEEDED.)
 7. CORRECTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-26 Cont ID  
Sent By jpearson Date 2019-12-26 Time 10:09 Rev Time 0.00
Received By jpearson Date 2019-12-26 Time 10:09 Sent To  
Notes
2019-12-26 10:09:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
 2. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. THE
 RECEPTACLE OUTLET SHALL BE LOCATED ON A WALL OR
 PARTITION THAT IS ADJACENT TO THE BASIN OR BASIN
 COUNTERTOP, LOCATED ON THE COUNTERTOP, OR INSTALLED ON
 THE SIDE OR FACE OF THE BASIN CABINET. PROVIDE
 CORRECTION FOR NEW BATH. NEC 210.11(C)(3), 210.52(D);
 FBC RE E3901.6
 3. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 4. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 5. SYMBOL USED FOR LIGHTING IN CLOSETS IS NOT DEFINED.
 PER CODE, LIGHTING WITH OPEN OR PARTIALLY ENCLOSED
 LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT
 BE PERMITTED IN CLOTHES CLOSETS. PROVIDE CORRECTION OR
 NOTE FOR COMPLIANCE. NEC 410.16; FBC RE E4003.12
 6. METER MAIN PANEL SCHEDULE SHOWS A WIRE SIZE OF #0/0
 ON A 200 AMP BREAKER. THIS WIRE SIZE DOES NOT EXIST.
 PLEASE CLARIFY THE WIRE SIZE IS SUFFICIENT FOR THE 200
 AMP BREAKER. ADDITIONALLY, THIS IS SHOWN FEEDING A 150
 AMP PANEL. A 200 AMP FEED CANNOT FEED A PANEL THAT IS
 RATED FOR ONLY 150 AMPS. PROVIDE CLARIFICATIONS AND/OR
 CORRECTIONS AS NEEDED. WPB FBC 107.2.1; NEC
 310.15(B)(16), 408.30
 7. PROVIDE SMOKE ALARM ON EACH STORY OF THE DWELLING.
 FBC RE R314.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-04 Cont ID  
Sent By cthroop Date 2020-09-04 Time 10:10 Rev Time 0.00
Received By cthroop Date 2020-09-03 Time 17:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-28 Cont ID  
Sent By rmcphers Date 2020-02-28 Time 09:15 Rev Time 0.00
Received By rmcphers Date 2020-02-01 Time 14:18 Sent To  
Notes
2020-02-28 09:16:24PLANS TAKEN TO PERMIT LIBRARY
2020-02-13 14:18:19R14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-01-16 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-16 Time 15:27 Sent To  
Notes
2019-12-17 15:27:19R27

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-09-04 Cont ID  
Sent By medwards Date 2020-09-04 Time 08:36 Rev Time 0.00
Received By medwards Date 2020-09-04 Time 08:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-02-14 Cont ID  
Sent By ccole Date 2020-02-14 Time 12:33 Rev Time 0.00
Received By ccole Date 2020-02-14 Time 12:33 Sent To  
Notes
2020-02-14 12:46:062ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19120656
 2/14/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-1: SHOW THE SUPPLY CFMS AT EACH NEW DIFFUSER
 LOCATION.
  
 2) M-1: SHOW RETURN AIR SYSTEM FROM THE MASTER BEDROOM
 SUITE. PLEASE NOTE ALL AIR SUPPLIED TO THE SUITE
 INCLUDING THE BATHROOM AND CLOSET SHALL BE RETURNED-
 SECTION M1602.3 EXCEPTION 3 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-16 Cont ID  
Sent By ccole Date 2020-01-16 Time 12:41 Rev Time 0.00
Received By ccole Date 2020-01-16 Time 12:40 Sent To I
Notes
2020-01-16 12:44:161ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120656
 1/16/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED. PLEASE
 CLARIFY IF ANY ALTERATIONS TO THE EXISTING HVAC SYSTEMS
 ARE PROPOSED INCLUDING KITCHEN AND BATH EXHAUST
 SYSTEMS, AC SYSTEM REPLACEMENTS, OR DUCT ALTERATIONS-
 SECTION 107.2.1 WPB. PLEASE NOTE THAT MECHANICAL
 EXHAUST IS REQUIRED FOR THE BATHS AT AN INTERMITTENT
 RATE OF 50 CFMS, AND FOR THE KITCHENS AT AN
 INTERMITTENT RATE OF 100 CFMS- TABLE 403.3.1.1 FBC M.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL NEW
 COOKING APPLIANCES AND KITCHEN HOODS- SECTIONS 505 AND
 917.2 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-09-04 Cont ID  
Sent By cthroop Date 2020-09-04 Time 10:10 Rev Time 0.00
Received By cthroop Date 2020-09-04 Time 09:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-02-18 Cont ID  
Sent By gjohnson Date 2020-02-18 Time 16:21 Rev Time 0.00
Received By gjohnson Date 2020-02-18 Time 11:31 Sent To  
Notes
2020-02-18 16:29:461ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE PLUMBING SHEETS ARE MISSING FROM PLAN SETS
 PLEASE PROVIDE 2 SETS OF COMPLETE PLAN SETS INCLUDING
 THE PLUMBING SHEET. PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-12-31 Cont ID  
Sent By lcrespo Date 2019-12-31 Time 06:15 Rev Time 0.00
Received By lcrespo Date 2019-12-31 Time 06:15 Sent To  
Notes
2019-12-31 07:37:4512/31/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-04 Cont ID  
Sent By medwards Date 2020-09-04 Time 08:40 Rev Time 0.00
Received By medwards Date 2020-09-04 Time 08:40 Sent To  
Notes
***NONE***