Plan Review Details - Permit 19120571
Plan Review Stops For Permit 19120571
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2020-08-05 Cont ID  
Sent By pvalenti Date 2020-08-05 Time 16:16 Rev Time 0.00
Received By pvalenti Date 2020-08-05 Time 16:16 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2020-07-14 Cont ID  
Sent By pvalenti Date 2020-07-14 Time 10:32 Rev Time 0.00
Received By pvalenti Date 2020-07-14 Time 08:36 Sent To  
Notes
2020-07-14 10:33:48PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 ASBESTOS REQUIREMENTS:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2020-02-18 Cont ID  
Sent By jwitmer Date 2020-02-18 Time 13:55 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2020-02-18 13:55:53ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-01-07 Cont ID  
Sent By jwitmer Date 2020-01-07 Time 08:32 Rev Time 0.00
Received By jwitmer Date 2020-01-07 Time 07:41 Sent To  
Notes
2020-01-07 08:32:31BUILT IN 1984. ASBESTOS COMMERCIAL. PLEASE PROVIDE A
 SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON
 LETTERHEAD, STATING THAT THE INSTRUCTIONS ON THE
 WEBSITE OF ASBESTOS PROGRAM COORDINATOR, FLORIDA
 DEPARTMENT OF HEALTH PALM BEACH COUNTY WILL BE FOLLOWED
 AND THAT NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-18 Cont ID  
Sent By jwitmer Date 2020-02-18 Time 14:52 Rev Time 0.00
Received By jwitmer Date 2020-02-18 Time 14:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-07 Cont ID  
Sent By jwitmer Date 2020-01-07 Time 11:08 Rev Time 0.00
Received By jwitmer Date 2020-01-07 Time 07:41 Sent To  
Notes
2020-01-07 11:08:522017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19120571
 ADD: 7610 GEORGIA AVE. SUITE # 11
 CONT: JEFFERY GOMERSALL BLDG.
 TEL: 561-718-1866
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 07/ 2020
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION INDICATES THE LOCATION OF THE
 PROJECT IS 7310 GEORGIA AVE., SUITE # 11. THE PLANS
 STATE THE JOBSITE LOCATION AS 7310 GEORGIA AVE. THE
 SUITE NUMBER IS NOT GIVEN. PALM BEACH COUNTY GEO NAV &
 GOOGLE MAPS INDICATE THERE IS ONLY (4) SUITES WITHIN
 THIS BUILDING. PLEASE IDENTIFY WHICH SUITE THE WORK TO
 BE COVERED UNDER THIS PERMIT IS LOCATED.
 2017 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND
 EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED
 ADDRESS IDENTIFICATION.
 61G1-16.004 TITLE BLOCK. ARCHITECT. (3) NAME OR
 IDENTIFICATION OF PROJECT.
  
 2) THE COVERSHEET C1:
  
 2A) UNDER THE HEADING OF OCCUPANCY TYPE THE OCCUPANCY
 LISTED IS A-2 FOR RESTAURANTS, BANQUET HALLS,
 CAFETERIAS AND OR TAVERNS AND BARS OR SIMILAR INTENDED
 USES FOR THE CONSUMPTION OF FOOD OR DRINK. THIS
 ESTABLISHMENT DOES NOT FIT THOSE DESCRIPTIONS. THE
 COVERSHEET LIST THE SQUARE FEET OF THIS TENANT SPACE AS
 1,295 SQUARE FEET. WITH THE USE AND SQUARE FOOTAGE THE
 MAIN OCCUPANCY IS BUSINESS. FOOD PROCESSING
 ESTABLISHMENTS AND COMMERCIAL KITCHENS NOT ASSOCIATED
 WITH RESTAURANTS, CAFETERIAS AND SIMILAR DINING
 FACILITIES NOT MORE THAN 2,500 SQUARE FEET IN AREA.
 PLEASE REVIEW THE 2017 FBC-B SECTION 304.1.
 THERE IS ALSO AN ENCLOSED PARKING SPACE OF 230 SQUARE
 FEET OVER 10% OF THE TENANT SPACE WHICH APPEARS THIS
 OCCUPANCY TO BE S-2 A MIXED OCCUPANCY BETWEEN BUSINESS
 AND ENCLOSED PARKING (S-2 OCCUPANCY).
  
 2B) UNTIL THE TENANT SPACE IS KNOWN, THE LAST KNOWN USE
 (BUSINESS TAX/ OCCUPATIONAL LICENSE) WE CANNOT
 DETERMINE IF THIS IS A LEVEL II ALTERATION OR A CHANGE
 OF OCCUPANCY WHICH WOULD HAVE TO COMPLY WITH THE 2017
 EXISTING BUILDING CODE SECTION 1001.2.2.1 PARTIAL
 CHANGE OF OCCUPANCY. WHERE THE OCCUPANCY CLASSIFICATION
 OR GROUP OF A PORTION OF AN EXISTING BUILDING IS
 CHANGED, SECTION 1012 SHALL APPLY.
  
 2C) THE COVERSHEET INDICATE THE BUILDING TYPE TO BE
 III-B. SHEET 1.0A INDICATES A WINDOW IS TO BE FILED IN
 ON THE EAST SIDE OF THE BUILDING, THE PROPERTY LINE
 WHICH IS LESS THAN 5 FEET AWAY REQUIRES THIS WALL TO BE
 1HOUR RATED BY TABLE 602 FOR BUSINESS AND S-2
 OCCUPANCIES 2017 FBC-B. PLEASE ALSO REFER TO SECTION
 602.3 & 2302 FIRE RETARDANT TREATED WOOD CAN BE USED
 WITHIN EXTERIOR WALL ASSEMBLIES OF A 2 HOUR RATING OR
 LESS. PLANS CALL OUT FOR 5/8 CDX PLYWOOD IN THE INFILL,
 PLEASE CORRECT THE PLANS.
  
 2D) THE LOCATION OF THIS TENANT SPACE IS UNKNOWN AT
 THIS TIME IN REGARDS TO THE OTHER TENANT OCCUPANCIES,
 BUT ALSO ON BOTH SIDES OF THIS BUILDING THE NEIGHBORING
 BUILDINGS HAVE ZERO LOT LINES BETWEEN BUILDINGS. THE
 COVERSHEET NOR SHEET 1.1A THE LIFE SAFETY SHEET
 INDICATE OCCUPANCY SEPARATION WITHIN THE TENANT SPACE
 OR THE NEIGHBORING TENANTS ON EACH SIDE OF THIS TENANT
 SPACE. SHOW COMPLIANCE WITH TABLE 508.4 REQUIRED
 SEPARATION OF OCCUPANCIES, SEE FOOTNOTE B FOR THE S-2
 OCCUPANCY.
  
 3) SHEET 1.1A:
 3A) PLEASE REVIEW THE LIFE SAFETY PLAN FOR EGRESS
 PURPOSES, THERE IS ONLY ONE MEANS OF EGRESS FROM THE
 KITCHEN WHICH TAKES YOU THROUGH A STORAGE ROOM AND A
 MORE DANGEROUS OCCUPANCY S2 ENCLOSED GARAGE BEFORE
 ENTERING THE BUSINESS OCCUPANCY. PLEASE REVIEW SECTION
 1016.2.5 OF THE 2017 FBC-B. EGRESS SHALL NOT PASS
 THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED
 FOR SIMILAR PURPOSES. SINCE YOU START IN THE KITCHEN IN
 THIS CASE A BUSINESS OCCUPANCY AND HAVE TO GO THROUGH A
 STORAGE ROOM, WHICH IS NOT PERMITTED, THEN INTO AN S-2
 OCCUPANCY REQUIRING 2 HOUR SEPARATION FOR
 NON-SPRINKLERED BUILDINGS, A MORE DANGEROUS OCCUPANCY.
  
 3B) THE LIFE SAFETY PLAN DOES NOT SHOW THE VAN IN THE
 PARKING GARAGE NOR DOES THE PLAN SHOW THAT DEPENDING ON
 THE TYPE OF VEHICLE AND LOCATION OF THE VEHICLE NEITHER
 THE DOUBLE SWING DOORS FROM THE KITCHEN NOR THE OFFICE
 DOOR CAN BE FULLY OPENED FOR EGRESS PURPOSE. PLEASE SEE
 SECTION 1010.1.1.1 PROJECTIONS INTO CLEAR WIDTH. OF THE
 2017 FBC-B. 1001.2 MINIMUM REQUIREMENTS. 2017 FBC-B IT
 SHALL BE UNLAWFUL TO ALTER A BUILDING OR STRUCTURE IN A
 MANNER THAT WILL REDUCE THE NUMBER OF EXITS OR THE
 MINIMUM WIDTH OR REQUIRED CAPACITY OF THE MEANS OF
 EGRESS TO LESS THAN REQUIRED BY THIS CODE.
  
 3C) PLEASE REVISE THE PLANS FOR A CONTINUOUS MEANS OF
 EGRESS AND IF THERE ARE STILL WALLS THAT ARE RATED THEN
 THE DOORS WILL NEED TO MEET THE REQUIREMENT OF OPENING
 PROTECTIVES IN 716.5 OF THE 2017 FBC-B.
  
 4) IT WOULD APPEAR FROM THE MECHANICAL SHEET THERE IS
 AN EXISTING AIR HANDLER AND ROOF TOP CONDENSER. THERE
 WILL BE THE REQUIREMENTS TO CUT THROUGH THE ROOF DECK
 AND FRAME OUT AROUND THE NEW OPENING AS WELL AS ROOF
 TOP CURBS FOR THE INTAKE & EXHAUST FOR THE NEW HOOD
 SYSTEM. THESE ITEMS ARE NOT SHOWN NOR IS THE WIND
 DESIGN CRITERIA FOR THE NEW COMPONENTS AND CLADDING FOR
 THE ROOF. IT IS ALSO NOT KNOWN IF THE NEW COOLER/
 FREEZER ARE GOING TO HAVE THEIR COMPRESSOR ON THE ROOF
 AS WELL. THESE ELEMENTS, HOOD & COOLER REQUIRE SEPARATE
 PERMITS AND REVIEW AND ASSOCIATED FEES. PLEASE SUPPLY
 ADDITIONAL INFORMATION IF THE ROOF TOP PENETRATIONS AND
 CURBS ARE GOING TO BE PART OF THIS PERMIT. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED TO DETERMINE CODE
 COMPLIANCE.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-03-01 Cont ID  
Sent By jpearson Date 2020-03-01 Time 10:48 Rev Time 0.00
Received By jpearson Date 2020-03-01 Time 10:48 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-30 Cont ID  
Sent By jpearson Date 2019-12-30 Time 14:21 Rev Time 0.00
Received By jpearson Date 2019-12-30 Time 11:11 Sent To  
Notes
2019-12-30 14:21:33CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLE OUTLETS
 IN KITCHEN AREA. NEC 210.8(B)
 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30
 3. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING
 PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK
 IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY
 OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-02-14 Cont ID  
Sent By pleduc Date 2020-02-14 Time   Rev Time 0.00
Received By pleduc Date 2020-02-14 Time 14:02 Sent To  
Notes
2020-02-14 14:04:09THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE KITCHEN HOOD AND FIRE SUPPRESSION SYTEMS SHALL
 BE SUBMITTED UNDER SEPARATE PERMITS AND SHOP DRAWINGS.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-12-31 Cont ID  
Sent By pleduc Date 2019-12-31 Time   Rev Time 0.00
Received By pleduc Date 2019-12-31 Time 11:40 Sent To  
Notes
2019-12-31 12:21:39THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET C 1 - THERE IS AN INDICATION OF AN ASSEMBLY
 OCUPANCY; HOWEVER, THE ARE SEPARATE OCCUPANCIES SHOWN,
 OFFICE (BUSINESS), GARAGE, STORAGE ROOM (STORAGE),
 KITCHEN (ASSEMBLY/MERCANTILE PER FFPC).
  
 PER NFPA 101, CHAPTER 6, OCCUPANCY CLASSIFICATION IS
 THIS A MIXED OR SEPARATED OCCUPANCY.
  
 6.1.14.2 DEFINITIONS.
 6.1.14.2.1 MULTIPLE OCCUPANCY. A BUILDING OR STRUCTURE
 IN WHICH TWO
 OR MORE CLASSES OF OCCUPANCY EXIST.
 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE
 THE
 OCCUPANCIES ARE INTERMINGLED.
 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY
 WHERE THE
 OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE?RATED
 ASSEMBLIES.
 6.1.14.3 MIXED OCCUPANCIES.
 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE
 CLASSIFIED AS TO ITS USE IN
 ACCORDANCE WITH SECTION 6.1.
 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST
 RESTRICTIVE
 REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS
 SEPARATE SAFEGUARDS
 ARE APPROVED.
 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.)
 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED,
 EACH PART OF THE
 BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED
 IN THIS CHAPTER,
 SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY
 FIRE-RESISTIVE
 ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3,
 TABLE 6.1.14.4.1(A),
 AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED
 BY APPROVED
 EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY
 6.1.14.4.6.
  
 PLEASE REVIEW AND PROVIDE APPLICABLE DETAILS
  
  
  
  
 2) SHEET 1.0 A - WITHIN THE DOOR SCHEDULE MARK 5 IS
 INDICATED A 10 X 10 GARAGE DOOR. THE FLOOR PLAN MARK IS
 INDICATED AS A DOUBLE SWINGING EXIT DOOR.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 3) SHEET 1.0 A - THERE IS ONLY ONE EXIT DOOR INDICATED.
 PER # 1 ABOVE AND A 2ND EXIT DOOR MAY BE REQUIRED.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY 1 EXIT WITH
 SPECIFIC CODE REFERENCES ALLOWING JUST 1.
  
  
  
 4) SHEET 1.0 A - DOOR MARK 5 IS SHOWN AS AN ONLY EXIT
 DOOR FROM THE KITCHEN THROUGH THE GARAGE (STORAGE) AREA
 INTO THE OFFICE AND THEN TO THE FRONT EXIT DOOR LEADING
 TO A PUBLICE WAY.
  
 EXITING THROUGH THE GARAGE WOULD NOT BE ALLOWED DUE TO
 THE OBSTRUCTION OF A VEHICLE
  
 PER NFPA 101, CH 7 MEANS OF EGRESS,
  
 7.1.10 MEANS OF EGRESS RELIABILITY.
 7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE
 CONTINUOUSLY
 MAINTAINED FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO
 FULL INSTANT
 USE IN THE CASE OF FIRE OR OTHER EMERGENCY.
 7.1.10.2 FURNISHINGS AND DECORATIONS IN MEANS OF
 EGRESS.
 7.1.10.2.1 NO FURNISHINGS, DECORATIONS, OR OTHER
 OBJECTS SHALL
 OBSTRUCT EXITS OR THEIR ACCESS THERETO, EGRESS THERE
 FROM, OR
 VISIBILITY THEREOF.
  
 PLEASE REVIEW AND CORRECT.
  
  
 4A) SHEET 1.0 A - DOOR MARK 5 IS SHOWN AS AN ONLY EXIT
 DOOR FROM THE KITCHEN THROUGH THE GARAGE (STORAGE) AREA
 INTO THE OFFICE AND THEN TO THE FRONT EXIT DOOR LEADING
 TO A PUBLICE WAY.
  
 EXITING THROUGH THE GARAGE WOULD NOT BE ALLOWED DUE
 ENTERING A HIGHER HAZARD AREA TO EXIT.
  
 PER NFPA 101, CH 7 MEANS OF EGRESS,
  
 7.5.2 IMPEDIMENTS TO EGRESS. SEE ALSO 7.1.9 AND
 7.2.1.5.
 7.5.2.1* ACCESS TO AN EXIT SHALL NOT BE THROUGH
 KITCHENS,
 STOREROOMS OTHER THAN AS PROVIDED IN CHAPTERS 36 AND
 37,
 RESTROOMS, CLOSETS, BEDROOMS OR SIMILAR SPACES, OR
 OTHER ROOMS OR
 SPACES SUBJECT TO LOCKING, UNLESS PASSAGE THROUGH SUCH
 ROOMS OR
 SPACES IS PERMITTED FOR THE OCCUPANCY BY CHAPTER 18,
 19, 22, OR 23.
  
 12.2.5.2 ACCESS THROUGH HAZARDOUS AREAS. MEANS OF
 EGRESS
 FROM A ROOM OR SPACE FOR ASSEMBLY PURPOSES SHALL NOT BE
 PERMITTED THROUGH KITCHENS, STOREROOMS, RESTROOMS,
 CLOSETS,
 PLATFORMS, STAGES, PROJECTION ROOMS, OR HAZARDOUS AREAS
 AS
 DESCRIBED IN 12.3.2.
  
 THE KITCHEN CAN EXIT THROUGH THE GARAGE.
  
 PLEASE REVIEW AND CORRECT.
  
  
 5) SHEET 1.0 A - THE DOOR MARK 5 IS SHOWN AS A DOUBLE
 SWING DOOR
  
 SHOULD A VEHICLE BE PARKED THE DOOR COULD NOT SWING-IN.
 HOW WOULD A PERSON KNOW NOT TO PUSH THE DOOR OPEN AND
 POSSIBLY BECOME INJURED WHILE TRYINBG TO EXIT IN AN
 EMERGENCY?
  
 PLEASE REVIEW AND CORRECT.
  
  
 6) SHEET 1.0 A - THE GARAGE IS CONSIDERED A PARKING
 STRUCTURE AND SHOULD COMPLY WITH NFPA 88A AND BE
 PROVIDED WITH VENTILATION.
  
 3.3.272.7* PARKING STRUCTURE. A BUILDING, STRUCTURE, OR
 PORTION
 THEREOF USED FOR THE PARKING, STORAGE, OR BOTH, OF
 MOTOR VEHICLES.
 [88A, 2015]
  
 PER NFPA 42 STORAGE OCCUPANCIES
  
 42.8 SPECIAL PROVISIONS FOR PARKING STRUCTURES.
 42.8.1 GENERAL REQUIREMENTS.
 42.8.1.1* APPLICATION. THE PROVISIONS OF 42.8.1 THROUGH
 42.8.5.4
 SHALL APPLY TO PARKING STRUCTURES OF THE CLOSED OR OPEN
 TYPE, ABOVE
 OR BELOW GRADE PLANE, BUT SHALL NOT APPLY TO ASSISTED
 MECHANICALTYPE
 OR AUTOMATED-TYPE PARKING FACILITIES THAT ARE NOT
 OCCUPIED BY
 CUSTOMERS. THE REQUIREMENTS OF SECTIONS 42.1 THROUGH
 42.7 SHALL
 NOT APPLY.
 42.8.1.4 CLASSIFICATION OF OCCUPANCY. INCIDENTAL
 VEHICLE PARKING
 IN ANOTHER OCCUPANCY SHALL NOT BE THE BASIS FOR OVERALL
 OCCUPANCY
 CLASSIFICATION.
 42.8.1.5 CLASSIFICATION OF HAZARD OF CONTENTS. PARKING
 STRUCTURES USED ONLY FOR THE STORAGE OF VEHICLES SHALL
 BE CLASSIFIED
 AS ORDINARY HAZARD IN ACCORDANCE WITH SECTION 6.2.
  
 NFPA 88A
  
 6.3 VENTILATION.
 6.3.1* ALL ENCLOSED PARKING STRUCTURES SHALL BE
 VENTILATED BY
 A MECHANICAL SYSTEM CAPABLE OF PROVIDING A MINIMUM OF
 300 L/MIN PER M2 OF FLOOR AREA (1 FT3/MIN PER FT2 OF
 FLOOR
 AREA) DURING HOURS OF NORMAL OPERATION.
  
 6.4 FIRE SPRINKLER SYSTEMS.
 6.4.1 AUTOMATIC SPRINKLER SYSTEMS SHALL CONFORM TO NFPA
 13.
 6.4.2 AUTOMATIC SPRINKLER SYSTEMS SHALL BE INSTALLED IN
 PORTIONS
 OF ENCLOSED PARKING STRUCTURES, THE CEILINGS OF WHICH
 ARE
 LESS THAN 600 MM (24 IN.) ABOVE GRADE, REGARDLESS OF
 TYPE OF
 CONSTRUCTION, AND IN ENCLOSED PARKING STRUCTURES OF
 TYPE III OR
 TYPE IV CONSTRUCTION OVER 15 M (50 FT) IN HEIGHT.
 6.4.3 AUTOMATIC SPRINKLER SYSTEMS SHALL BE INSTALLED IN
 ENCLOSED
 PARKING STRUCTURES LOCATED AT OR ABOVE GRADE, OR WITHIN
 OR IMMEDIATELY BELOW A BUILDING USED FOR ANOTHER
 OCCUPANCY.
  
  
 PLEASE REVIEW AND COMPLY.
  
  
  
 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-02-24 Cont ID  
Sent By jesmith Date 2020-02-24 Time 16:09 Rev Time 0.00
Received By jesmith Date 2020-02-24 Time 16:08 Sent To  
Notes
2020-02-24 16:09:35GAS COMMENTS: APPROVED
 CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR
 MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL
 GAS INSPECTION.
 CALL 561-805-6692 FOR FURTHER INFORMATION.
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 19120571 7310 GEORGIA AVE # 1
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-01-06 Cont ID  
Sent By jesmith Date 2020-01-06 Time 15:18 Rev Time 0.00
Received By jesmith Date 2020-01-06 Time 15:17 Sent To  
Notes
2020-01-06 15:18:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 GAS COMMENTS: DENIED
 1. PLAN SHEET 1.1A KITCHEN EQUIPMENT SCHEDULE; BLANK
 SPACE BETWEEN ITEM 1 AND ITEM 2 INDICATES ACTUAL
 SERVICES REQUIRED IDENTICAL TO ITEM 1. ITEM 1 INDICATES
 ONE (1) CONVECTION OVEN AT 90,000 BTUS. PLAN SHEET 3.0
 SHOWS TWO (2). PER WPB FBC 107.2.1 PLEASE CLARIFY.
 2. PER WPB FBC 107.2.1, SPECIFY THE TANKLESS WATER
 HEATER AT THE LAVATORY AND PROVIDE MANUFACTURER?S
 SPECIFICATION THE GAS TANKLESS WATER HEATER.
 3. PLAN PAGE 3.0P; GAS INSTA-HOT WATER HEATER DETAIL
 INDICATES ONE VENT. THE UNIT SPECIFIED IS SEALED
 COMBUSTION AND REQUIRES AN AIR INTAKE VENT AS WELL AS
 AN EXHAUST VENT. PER WPB FBC 107.2.1, PROVIDE CORRECT
 VENTING DETAILS, SUBMITTING A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE THE
 ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) COMPLYING
 WITH FBC FG SECS. 502 THROUGH 505.
 4. PLAN PAGE 3.0P; PER WPB FBC 107.2.1, CORRECTLY
 IDENTIFY THE EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE.
 VALVE SHALL BE LOCATED BELOW THE CEILING. THE MANUAL
 SHUTOFF VALVE SHALL BE UPSTREAM. UNION TO BE DOWN
 STREAM OF MANUAL VALVE AHEAD OF EMERGENCY SHUT OFF
 VALVE. SECS. 10.4, 10.5 OF NFPA 96-08. SHOW LOCATION ON
 THE PLAN VIEW
 5. PER WPB FBC 107.2.1, INDICATE PIPE MATERIAL AS NOTED
 IN FBC FG TABLE 402.4(2).
 6. PER WPB FBC 107.2.1, SUBMIT CALCULATIONS FOR
 COMBUSTION AIR PER FBC FG 304.1.
 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND FBC FG
 402.2 AND 301.3. GAS APPLIANCES SHALL BE LISTED AND
 LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FBC FG 305.1.
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19120571 7310 GEORGIA AVE # 1
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-07-14 Cont ID  
Sent By pvalenti Date 2020-07-14 Time 13:49 Rev Time 0.00
Received By pvalenti Date 2020-07-13 Time 12:54 Sent To  
Notes
2020-07-13 14:20:55TO PV DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-03-01 Time   Rev Time 0.00
Received By lmarchan Date 2020-02-12 Time 14:20 Sent To  
Notes
2020-02-13 14:20:37B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-01-07 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-13 Time 13:03 Sent To  
Notes
2019-12-16 13:03:59B16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2020-08-05 Cont ID  
Sent By pvalenti Date 2020-08-05 Time 16:19 Rev Time 0.00
Received By pvalenti Date 2020-08-05 Time 16:19 Sent To  
Notes
2020-08-05 16:24:33PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 IMPACT FEE REVIEW APPROVED:
  
 PALM BEACH COUNTY REVIEWED FOR IMPACT FEES.
 PLANS STAMPED ON 7/23/2020 BY K. DWYER STATING NO FEES
 DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2020-07-14 Cont ID  
Sent By pvalenti Date 2020-07-14 Time 10:35 Rev Time 0.00
Received By pvalenti Date 2020-07-14 Time 08:36 Sent To  
Notes
2020-07-14 10:36:21PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 IMPACT FEES? PAPER SUBMITTALS. PLANS REQUIRE REVIEW BY
 THE PBC IMPACT FEE OFFICE. CALL (561) 233?5025. UPON
 APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO
 THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND
 WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE
 PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT:
 HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPAC
 TFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-01-07 Cont ID  
Sent By jwitmer Date 2020-01-07 Time 11:09 Rev Time 0.00
Received By jwitmer Date 2020-01-07 Time 07:41 Sent To  
Notes
2020-01-07 11:09:29IMPACT FEES- PAPER SUBMITTALS. PLANS REQUIRE REVIEW BY
 THE PBC IMPACT FEE OFFICE. CALL (561) 233-5025. UPON
 APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO
 THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND
 WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE
 PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT:
 HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPAC
 TFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2020-07-20 Cont ID  
Sent By pvalenti Date 2020-07-20 Time 15:40 Rev Time 0.00
Received By pvalenti Date 2020-07-20 Time 15:39 Sent To  
Notes
2020-07-20 15:42:04PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW APPROVED WITH PROVISOS:
  
 1) IF THE WELDING OPTION IS SELECTED FOR THE RTU STAND
 CONNECTIONS THE FOLLOWING ARE REQUIRED TO BE APPROVED
 BY THE DESIGNER OF RECORD:
 AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
 2) AS PER SECTION FBC M 508.1.1, THE TEMPERATURE
 DIFFERENTIAL BETWEEN THE MAKE?UP AIR AND THE
 CONDITIONED SPACE MUST NOT EXCEED 10 DEGREES F.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2020-07-14 Cont ID  
Sent By pvalenti Date 2020-07-14 Time 13:29 Rev Time 0.00
Received By pvalenti Date 2020-07-14 Time 08:50 Sent To  
Notes
2020-07-14 13:44:33PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 4TH MECHANICAL REVIEW DENIED:
  
 FBC M 602.1 - 602.2, PLEASE PROVIDE THE DOOR DETAILS
 FOR THE AIR HANDLER CLOSET AS THIS CLOSET APPEARS TO BE
 A PLENUM.
  
  
 PROVISOS:
  
 1) IF THE WELDING OPTION IS SELECTED FOR THE RTU STAND
 CONNECTIONS THE FOLLOWING ARE REQUIRED TO BE APPROVED
 BY THE DESIGNER OF RECORD:
 AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S.
 SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING:
 BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO
 BE USED.
 AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  
 2) AS PER SECTION FBC M 508.1.1, THE TEMPERATURE
 DIFFERENTIAL BETWEEN THE MAKE-UP AIR AND THE
 CONDITIONED SPACE MUST NOT EXCEED 10 DEGREES F.
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-02-24 Cont ID  
Sent By ccole Date 2020-02-24 Time 10:05 Rev Time 0.00
Received By ccole Date 2020-02-24 Time 09:28 Sent To  
Notes
2020-02-24 10:06:443RD REVIEW FBC-2017 MECHANICAL
 PERMIT #19120571
 2/19/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ENERGY COMPLIANCE REPORT REQUIRED.
  
 A) THE PROPOSED BUSINESS OCCUPANCY IS A CHANGE OF
 OCCUPANCY AND USE FROM THE PREVIOUS STORAGE WAREHOUSE
 OCCUPANCY- SEE SECTION C505.1 FBC EC.
  
 B) SECTION C503.2 FBC EC CHANGE IN SPACE CONDITIONING.
 ANY NONCONDITIONED OR LOW-ENERGY SPACE THAT IS ALTERED
 TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE
 BROUGHT INTO FULL COMPLIANCE WITH THIS CODE.
  
 REFER TO SECTION C101.5 AND C401.2 AND SUBMIT A
 COMPLIANCE REPORT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-02-19 Cont ID  
Sent By ccole Date 2020-02-19 Time 10:52 Rev Time 0.00
Received By ccole Date 2020-02-19 Time 10:34 Sent To  
Notes
2020-02-19 11:09:412ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19120571
 2/19/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ENERGY COMPLIANCE REPORT REQUIRED.
  
 A) THE PROPOSED BUSINESS OCCUPANCY IS A CHANGE OF
 OCCUPANCY AND USE FROM THE PREVIOUS STORAGE WAREHOUSE
 OCCUPANCY- SEE SECTION C505.1 FBC EC.
  
 B) SECTION C503.2 FBC EC CHANGE IN SPACE CONDITIONING.
 ANY NONCONDITIONED OR LOW-ENERGY SPACE THAT IS ALTERED
 TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE
 BROUGHT INTO FULL COMPLIANCE WITH THIS CODE.
  
 REFER TO SECTION C101.5 AND C401.2 AND SUBMIT A
 COMPLIANCE REPORT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-12-31 Cont ID  
Sent By ccole Date 2019-12-31 Time 16:52 Rev Time 0.00
Received By ccole Date 2019-12-31 Time 15:30 Sent To  
Notes
2019-12-31 17:08:311ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120571
 12/31/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REFER TO SECTION 301.1 FBC EX AND INDICATE WHAT
 COMPLIANCE METHOD WILL BE CHOSEN FOR THE PROPOSED
 OCCUPANCY. PLEASE NOTE THAT THE NEW COMMERCIAL KITCHEN
 APPEARS TO BE A CHANGE OF OCCUPANCY AS DEFINED IN
 SECTION 202, AND MAY REQUIRE SUBMITTAL OF ENERGY
 CALCULATIONS- SECTION C505.1 FBC EC.
  
 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW 5-TON SYSTEM IN ACCORDANCE WITH SECTION C403.2.1
 FBC EC.
  
 3) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN
 EXHAUST HOODS, FIRE SUPPRESSION SYSTEMS, AND THE WALK
 IN COOLER- SECTION 107.2.1 WPB. PLEASE PLACE A BOLD
 NOTE ON THE PLAN FOR CLARIFICATION.
  
 4) SHEET 4.0M: PROVIDE MINIMUM VENTILATION CALCULATIONS
 FOR ALL ROOMS AND SPACES PER TABLE 403.3.1.1 FBC M.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR.
  
 5) SHEET 4.0M: PROVIDE AN AIR BALANCE CALCULATION-
 SECTION 508.1.2 FBC M.
  
 6) SHEET 4.0M: A DUCT SMOKE DETECTOR IS REQUIRED IN THE
 SUPPLY AIR SYSTEM OF THE 5-TON AC SYSTEM PER SECTION
 606.2.1. PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED
 IF THE MANUFACTURER'S PERFORMANCE DATA INDICATES THE
 AIR HANDLER IS NOT CAPABLE OF PRODUCING OVER 2000 CFMS
 OF SUPPLY AIR.
  
 7) SHEET 4.0M: PROVIDE AN AUTOMATICALLY CONTROLLED
 SHUTOFF DAMPER- GRAVITY OR MOTORIZED- FOR THE O/A
 INTAKE DUCTS- SECTION C403.2.4.3 FBC EC.
  
 8) SHEET 4.0M: A NON-COMBUSTIBLE DOOR FOR THE AC CLOSET
 WILL BE REQUIRED IF THE RETURN IS NOT DUCTED DIRECTLY
 TO THE AIR HANDLER- SEE SECTION 602.2.1 FBC M.
  
 9) ADVISORY CONCERNING THE KITCHEN HOOD PERMIT: VERIFY
 THAT THE TEMPERATURE DIFFERENTIAL BETWEEN THE EXHAUST
 HOOD MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE
 DOES NOT EXCEED 10 DEGREES F- SECTION 508.1.1
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-02-24 Cont ID  
Sent By jesmith Date 2020-02-24 Time 16:07 Rev Time 0.00
Received By jesmith Date 2020-02-24 Time 16:07 Sent To  
Notes
2020-02-24 16:07:41PLUMBING COMMENTS: APPROVED
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 19120571 7310 GEORGIA AVE # 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-01-06 Cont ID  
Sent By jesmith Date 2020-01-06 Time 14:16 Rev Time 0.00
Received By jesmith Date 2020-01-06 Time 14:08 Sent To  
Notes
2020-01-06 14:15:50CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 1. PER WPB FBC 107.2.1, PROVIDE SIZING PROCEDURE AND
 CALCULATIONS AS CALLED OUT IN STD. PDI-G101 USED IN
 DETERMINING THE GB-75 INTERCEPTOR.
 2. THE SPECIFIED FL1170 DOES NOT COMPLY WITH ASSE 1070
 AS REQUIRED BY FBC PL 416.5. PER WPB FBC 107.2.1,
 REVISE AND RESUBMIT.
 3. SPECIFY THAT A WATER TEMPERING DEVICE SHALL BE
 FURNISHED FOR THE LAVATORY IN ACCORDANCE WITH FBC PL
 416.5.
 4. PER WPB FBC 107.2.1, SPECIFY THE TANKLESS WATER
 HEATER AT THE LAVATORY AND PROVIDE MANUFACTURER?S
 SPECIFICATION FOR THE SAME.
 5. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S
 SPECIFICATION FOR THE GAS TANKLESS WATER HEATER.
 6. WATER RISER MISTAKENLY IDENTIFIES SECTIONS OF COLD
 WATER DISTRIBUTION AS HOT WATER WHICH IS FEEDING THE
 TANKLESS WATER HEATER AS WELL AS THE HAND SINK AND MOP
 SINK. EFFECTIVELY THERE IS NO HOT WATER TO THE HAND
 SINK OR MOP SINK. PER WPB FBC 107.2.1, CORRECT AND
 RESUBMIT. ADDITIONALLY, SHOW THE EXISTING COLD WATER
 SUPPLY TO THE EXISTING BATHROOM.
 7. PLAN PAGE 3.0P GAS INSTA-HOT WATER HEATER DETAIL HAS
 TWO NOTES: 1)WATER HEATER SET TO 140 DEGREES FOR
 WAREWASH ONLY; 1)WATER HEATER SET TO 110 DEGREES FOR
 HAND AND PREP SINKS ONLY. PER WPB FBC 107.2.1, PLEASE
 CLARIFY.
 8. PER WPB FBC 107.2.1, SPECIFY FAUCET FOR MOP SINK
 WHICH COMPLIES WITH FBC PL 608.2 BACKFLOW PROTECTION.
 9. PER WPB FBC 107.2.1, PROVIDE BACKFLOW PROTECTION IN
 COLD WATER SUPPLY TO THE ICEMAKER TO COMPLY WITH FBC PL
 608.3.
 10. PLAN SHEET 1.1A KITCHEN EQUIPMENT SCHEDULE; ITEM
 16, WAREWASHER (DISHWASHER) CALLS FOR A 2 INCH INDIRECT
 WASTE. PER WPB FBC 107.2.1, INDICATE ON THE SANITARY
 ISOMETRIC THAT INDIRECT WASTE AND WHERE IT DISCHARGES
 TO. COMPLY WITH FBC PL 802.1.7. ADDITIONALLY, INSURE
 THAT THE QUANTITY AND THE LOCATIONS OF FLOOR SINKS ARE
 THE SAME ON BOTH RISER AND FLOOR PLAN.
 11. A VENTED TRAP HAS BEEN PROVIDED AND IDENTIFIED AS A
 FLOOR SINK/ DR (DISHTABLE?). THE EQUIPMENT SCHEDULE
 CALL FOR A 1-1/2 INCH DIRECT CONNECTION TO THE
 SANITARY. PER WPB FBC 107.2.1, CLARIFY THAT THE VENTED
 TRAP IS PROVIDING THA AND IS NOT THE FLOOR SINK FOR THE
 DISHWASHER.
 12. PER WPB FBC 107.2.1, PROVIDE INDIVIDUAL INDIRECT
 WASTE FROM EACH WELL OF THE THREE-COMPARTMENT SINK
 DISCHARGING INDEPENDENTLY TO THE FLOOR SINK TO COMPLY
 FBC FL 802.1.
 13. PER WPB FBC 107.2.1, CLEARLY INDICATE HOW THE
 DISPOSAL OF COOLER AND FREEZER EVAPORATOR CONDENSATE
 WILL BE HANDLED.
 14. IF OCCUPANCY A-2 AND OCCUPANT LOAD CALCULATION IS
 NOT DISPUTED BY THE BUILDING PLANS EXAMINER, THEN THE
 FIXTURE REQUIREMENTS PER FBC PL SECTION 403 ARE
 COMPLIED WITH.
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19120571 7310 GEORGIA AVE # 1
  