Plan Review Details - Permit 19120571
| Plan Review Stops For Permit 19120571 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-05 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-05 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-14 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-14 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2020-07-14 10:33:48 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | ASBESTOS REQUIREMENTS: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2020-02-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-02-18 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-18 13:55:53 | ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED | | | ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD, | | | STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF | | | ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF | | | HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT | | | NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL | | | INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE | | | FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-01-07 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-01-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2020-01-07 08:32:31 | BUILT IN 1984. ASBESTOS COMMERCIAL. PLEASE PROVIDE A | | | SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON | | | LETTERHEAD, STATING THAT THE INSTRUCTIONS ON THE | | | WEBSITE OF ASBESTOS PROGRAM COORDINATOR, FLORIDA | | | DEPARTMENT OF HEALTH PALM BEACH COUNTY WILL BE FOLLOWED | | | AND THAT NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL | | | INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE | | | FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-02-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-02-18 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-02-18 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-01-07 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-01-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2020-01-07 11:08:52 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19120571 | | | ADD: 7610 GEORGIA AVE. SUITE # 11 | | | CONT: JEFFERY GOMERSALL BLDG. | | | TEL: 561-718-1866 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JAN. 07/ 2020 | | | ACTION: DENIED | | | | | | 1) THE PERMIT APPLICATION INDICATES THE LOCATION OF THE | | | PROJECT IS 7310 GEORGIA AVE., SUITE # 11. THE PLANS | | | STATE THE JOBSITE LOCATION AS 7310 GEORGIA AVE. THE | | | SUITE NUMBER IS NOT GIVEN. PALM BEACH COUNTY GEO NAV & | | | GOOGLE MAPS INDICATE THERE IS ONLY (4) SUITES WITHIN | | | THIS BUILDING. PLEASE IDENTIFY WHICH SUITE THE WORK TO | | | BE COVERED UNDER THIS PERMIT IS LOCATED. | | | 2017 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND | | | EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED | | | ADDRESS IDENTIFICATION. | | | 61G1-16.004 TITLE BLOCK. ARCHITECT. (3) NAME OR | | | IDENTIFICATION OF PROJECT. | | | | | | 2) THE COVERSHEET C1: | | | | | | 2A) UNDER THE HEADING OF OCCUPANCY TYPE THE OCCUPANCY | | | LISTED IS A-2 FOR RESTAURANTS, BANQUET HALLS, | | | CAFETERIAS AND OR TAVERNS AND BARS OR SIMILAR INTENDED | | | USES FOR THE CONSUMPTION OF FOOD OR DRINK. THIS | | | ESTABLISHMENT DOES NOT FIT THOSE DESCRIPTIONS. THE | | | COVERSHEET LIST THE SQUARE FEET OF THIS TENANT SPACE AS | | | 1,295 SQUARE FEET. WITH THE USE AND SQUARE FOOTAGE THE | | | MAIN OCCUPANCY IS BUSINESS. FOOD PROCESSING | | | ESTABLISHMENTS AND COMMERCIAL KITCHENS NOT ASSOCIATED | | | WITH RESTAURANTS, CAFETERIAS AND SIMILAR DINING | | | FACILITIES NOT MORE THAN 2,500 SQUARE FEET IN AREA. | | | PLEASE REVIEW THE 2017 FBC-B SECTION 304.1. | | | THERE IS ALSO AN ENCLOSED PARKING SPACE OF 230 SQUARE | | | FEET OVER 10% OF THE TENANT SPACE WHICH APPEARS THIS | | | OCCUPANCY TO BE S-2 A MIXED OCCUPANCY BETWEEN BUSINESS | | | AND ENCLOSED PARKING (S-2 OCCUPANCY). | | | | | | 2B) UNTIL THE TENANT SPACE IS KNOWN, THE LAST KNOWN USE | | | (BUSINESS TAX/ OCCUPATIONAL LICENSE) WE CANNOT | | | DETERMINE IF THIS IS A LEVEL II ALTERATION OR A CHANGE | | | OF OCCUPANCY WHICH WOULD HAVE TO COMPLY WITH THE 2017 | | | EXISTING BUILDING CODE SECTION 1001.2.2.1 PARTIAL | | | CHANGE OF OCCUPANCY. WHERE THE OCCUPANCY CLASSIFICATION | | | OR GROUP OF A PORTION OF AN EXISTING BUILDING IS | | | CHANGED, SECTION 1012 SHALL APPLY. | | | | | | 2C) THE COVERSHEET INDICATE THE BUILDING TYPE TO BE | | | III-B. SHEET 1.0A INDICATES A WINDOW IS TO BE FILED IN | | | ON THE EAST SIDE OF THE BUILDING, THE PROPERTY LINE | | | WHICH IS LESS THAN 5 FEET AWAY REQUIRES THIS WALL TO BE | | | 1HOUR RATED BY TABLE 602 FOR BUSINESS AND S-2 | | | OCCUPANCIES 2017 FBC-B. PLEASE ALSO REFER TO SECTION | | | 602.3 & 2302 FIRE RETARDANT TREATED WOOD CAN BE USED | | | WITHIN EXTERIOR WALL ASSEMBLIES OF A 2 HOUR RATING OR | | | LESS. PLANS CALL OUT FOR 5/8 CDX PLYWOOD IN THE INFILL, | | | PLEASE CORRECT THE PLANS. | | | | | | 2D) THE LOCATION OF THIS TENANT SPACE IS UNKNOWN AT | | | THIS TIME IN REGARDS TO THE OTHER TENANT OCCUPANCIES, | | | BUT ALSO ON BOTH SIDES OF THIS BUILDING THE NEIGHBORING | | | BUILDINGS HAVE ZERO LOT LINES BETWEEN BUILDINGS. THE | | | COVERSHEET NOR SHEET 1.1A THE LIFE SAFETY SHEET | | | INDICATE OCCUPANCY SEPARATION WITHIN THE TENANT SPACE | | | OR THE NEIGHBORING TENANTS ON EACH SIDE OF THIS TENANT | | | SPACE. SHOW COMPLIANCE WITH TABLE 508.4 REQUIRED | | | SEPARATION OF OCCUPANCIES, SEE FOOTNOTE B FOR THE S-2 | | | OCCUPANCY. | | | | | | 3) SHEET 1.1A: | | | 3A) PLEASE REVIEW THE LIFE SAFETY PLAN FOR EGRESS | | | PURPOSES, THERE IS ONLY ONE MEANS OF EGRESS FROM THE | | | KITCHEN WHICH TAKES YOU THROUGH A STORAGE ROOM AND A | | | MORE DANGEROUS OCCUPANCY S2 ENCLOSED GARAGE BEFORE | | | ENTERING THE BUSINESS OCCUPANCY. PLEASE REVIEW SECTION | | | 1016.2.5 OF THE 2017 FBC-B. EGRESS SHALL NOT PASS | | | THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED | | | FOR SIMILAR PURPOSES. SINCE YOU START IN THE KITCHEN IN | | | THIS CASE A BUSINESS OCCUPANCY AND HAVE TO GO THROUGH A | | | STORAGE ROOM, WHICH IS NOT PERMITTED, THEN INTO AN S-2 | | | OCCUPANCY REQUIRING 2 HOUR SEPARATION FOR | | | NON-SPRINKLERED BUILDINGS, A MORE DANGEROUS OCCUPANCY. | | | | | | 3B) THE LIFE SAFETY PLAN DOES NOT SHOW THE VAN IN THE | | | PARKING GARAGE NOR DOES THE PLAN SHOW THAT DEPENDING ON | | | THE TYPE OF VEHICLE AND LOCATION OF THE VEHICLE NEITHER | | | THE DOUBLE SWING DOORS FROM THE KITCHEN NOR THE OFFICE | | | DOOR CAN BE FULLY OPENED FOR EGRESS PURPOSE. PLEASE SEE | | | SECTION 1010.1.1.1 PROJECTIONS INTO CLEAR WIDTH. OF THE | | | 2017 FBC-B. 1001.2 MINIMUM REQUIREMENTS. 2017 FBC-B IT | | | SHALL BE UNLAWFUL TO ALTER A BUILDING OR STRUCTURE IN A | | | MANNER THAT WILL REDUCE THE NUMBER OF EXITS OR THE | | | MINIMUM WIDTH OR REQUIRED CAPACITY OF THE MEANS OF | | | EGRESS TO LESS THAN REQUIRED BY THIS CODE. | | | | | | 3C) PLEASE REVISE THE PLANS FOR A CONTINUOUS MEANS OF | | | EGRESS AND IF THERE ARE STILL WALLS THAT ARE RATED THEN | | | THE DOORS WILL NEED TO MEET THE REQUIREMENT OF OPENING | | | PROTECTIVES IN 716.5 OF THE 2017 FBC-B. | | | | | | 4) IT WOULD APPEAR FROM THE MECHANICAL SHEET THERE IS | | | AN EXISTING AIR HANDLER AND ROOF TOP CONDENSER. THERE | | | WILL BE THE REQUIREMENTS TO CUT THROUGH THE ROOF DECK | | | AND FRAME OUT AROUND THE NEW OPENING AS WELL AS ROOF | | | TOP CURBS FOR THE INTAKE & EXHAUST FOR THE NEW HOOD | | | SYSTEM. THESE ITEMS ARE NOT SHOWN NOR IS THE WIND | | | DESIGN CRITERIA FOR THE NEW COMPONENTS AND CLADDING FOR | | | THE ROOF. IT IS ALSO NOT KNOWN IF THE NEW COOLER/ | | | FREEZER ARE GOING TO HAVE THEIR COMPRESSOR ON THE ROOF | | | AS WELL. THESE ELEMENTS, HOOD & COOLER REQUIRE SEPARATE | | | PERMITS AND REVIEW AND ASSOCIATED FEES. PLEASE SUPPLY | | | ADDITIONAL INFORMATION IF THE ROOF TOP PENETRATIONS AND | | | CURBS ARE GOING TO BE PART OF THIS PERMIT. 107.2.1.2 | | | ADDITIONAL INFORMATION IS REQUIRED TO DETERMINE CODE | | | COMPLIANCE. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-03-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-03-01 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-03-01 |
Time |
10:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-30 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-30 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2019-12-30 14:21:33 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLE OUTLETS | | | IN KITCHEN AREA. NEC 210.8(B) | | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR MAIN SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30 | | | 3. FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, LIGHTNING | | | PROTECTION, GENERATORS, COMMERCIAL HOOD SYSTEMS, WALK | | | IN COOLERS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND PLAN SUBMITTALS FOR ANY | | | OF THESE SYSTEMS PRESENT. WPB FBC 105.1, 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-02-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-02-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-02-14 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2020-02-14 14:04:09 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE KITCHEN HOOD AND FIRE SUPPRESSION SYTEMS SHALL | | | BE SUBMITTED UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-12-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-12-31 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-12-31 12:21:39 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET C 1 - THERE IS AN INDICATION OF AN ASSEMBLY | | | OCUPANCY; HOWEVER, THE ARE SEPARATE OCCUPANCIES SHOWN, | | | OFFICE (BUSINESS), GARAGE, STORAGE ROOM (STORAGE), | | | KITCHEN (ASSEMBLY/MERCANTILE PER FFPC). | | | | | | PER NFPA 101, CHAPTER 6, OCCUPANCY CLASSIFICATION IS | | | THIS A MIXED OR SEPARATED OCCUPANCY. | | | | | | 6.1.14.2 DEFINITIONS. | | | 6.1.14.2.1 MULTIPLE OCCUPANCY. A BUILDING OR STRUCTURE | | | IN WHICH TWO | | | OR MORE CLASSES OF OCCUPANCY EXIST. | | | 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE | | | THE | | | OCCUPANCIES ARE INTERMINGLED. | | | 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY | | | WHERE THE | | | OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE?RATED | | | ASSEMBLIES. | | | 6.1.14.3 MIXED OCCUPANCIES. | | | 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE | | | CLASSIFIED AS TO ITS USE IN | | | ACCORDANCE WITH SECTION 6.1. | | | 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST | | | RESTRICTIVE | | | REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS | | | SEPARATE SAFEGUARDS | | | ARE APPROVED. | | | 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.) | | | 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED, | | | EACH PART OF THE | | | BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED | | | IN THIS CHAPTER, | | | SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY | | | FIRE-RESISTIVE | | | ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3, | | | TABLE 6.1.14.4.1(A), | | | AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED | | | BY APPROVED | | | EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY | | | 6.1.14.4.6. | | | | | | PLEASE REVIEW AND PROVIDE APPLICABLE DETAILS | | | | | | | | | | | | | | | 2) SHEET 1.0 A - WITHIN THE DOOR SCHEDULE MARK 5 IS | | | INDICATED A 10 X 10 GARAGE DOOR. THE FLOOR PLAN MARK IS | | | INDICATED AS A DOUBLE SWINGING EXIT DOOR. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 3) SHEET 1.0 A - THERE IS ONLY ONE EXIT DOOR INDICATED. | | | PER # 1 ABOVE AND A 2ND EXIT DOOR MAY BE REQUIRED. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY 1 EXIT WITH | | | SPECIFIC CODE REFERENCES ALLOWING JUST 1. | | | | | | | | | | | | 4) SHEET 1.0 A - DOOR MARK 5 IS SHOWN AS AN ONLY EXIT | | | DOOR FROM THE KITCHEN THROUGH THE GARAGE (STORAGE) AREA | | | INTO THE OFFICE AND THEN TO THE FRONT EXIT DOOR LEADING | | | TO A PUBLICE WAY. | | | | | | EXITING THROUGH THE GARAGE WOULD NOT BE ALLOWED DUE TO | | | THE OBSTRUCTION OF A VEHICLE | | | | | | PER NFPA 101, CH 7 MEANS OF EGRESS, | | | | | | 7.1.10 MEANS OF EGRESS RELIABILITY. | | | 7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE | | | CONTINUOUSLY | | | MAINTAINED FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO | | | FULL INSTANT | | | USE IN THE CASE OF FIRE OR OTHER EMERGENCY. | | | 7.1.10.2 FURNISHINGS AND DECORATIONS IN MEANS OF | | | EGRESS. | | | 7.1.10.2.1 NO FURNISHINGS, DECORATIONS, OR OTHER | | | OBJECTS SHALL | | | OBSTRUCT EXITS OR THEIR ACCESS THERETO, EGRESS THERE | | | FROM, OR | | | VISIBILITY THEREOF. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 4A) SHEET 1.0 A - DOOR MARK 5 IS SHOWN AS AN ONLY EXIT | | | DOOR FROM THE KITCHEN THROUGH THE GARAGE (STORAGE) AREA | | | INTO THE OFFICE AND THEN TO THE FRONT EXIT DOOR LEADING | | | TO A PUBLICE WAY. | | | | | | EXITING THROUGH THE GARAGE WOULD NOT BE ALLOWED DUE | | | ENTERING A HIGHER HAZARD AREA TO EXIT. | | | | | | PER NFPA 101, CH 7 MEANS OF EGRESS, | | | | | | 7.5.2 IMPEDIMENTS TO EGRESS. SEE ALSO 7.1.9 AND | | | 7.2.1.5. | | | 7.5.2.1* ACCESS TO AN EXIT SHALL NOT BE THROUGH | | | KITCHENS, | | | STOREROOMS OTHER THAN AS PROVIDED IN CHAPTERS 36 AND | | | 37, | | | RESTROOMS, CLOSETS, BEDROOMS OR SIMILAR SPACES, OR | | | OTHER ROOMS OR | | | SPACES SUBJECT TO LOCKING, UNLESS PASSAGE THROUGH SUCH | | | ROOMS OR | | | SPACES IS PERMITTED FOR THE OCCUPANCY BY CHAPTER 18, | | | 19, 22, OR 23. | | | | | | 12.2.5.2 ACCESS THROUGH HAZARDOUS AREAS. MEANS OF | | | EGRESS | | | FROM A ROOM OR SPACE FOR ASSEMBLY PURPOSES SHALL NOT BE | | | PERMITTED THROUGH KITCHENS, STOREROOMS, RESTROOMS, | | | CLOSETS, | | | PLATFORMS, STAGES, PROJECTION ROOMS, OR HAZARDOUS AREAS | | | AS | | | DESCRIBED IN 12.3.2. | | | | | | THE KITCHEN CAN EXIT THROUGH THE GARAGE. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 5) SHEET 1.0 A - THE DOOR MARK 5 IS SHOWN AS A DOUBLE | | | SWING DOOR | | | | | | SHOULD A VEHICLE BE PARKED THE DOOR COULD NOT SWING-IN. | | | HOW WOULD A PERSON KNOW NOT TO PUSH THE DOOR OPEN AND | | | POSSIBLY BECOME INJURED WHILE TRYINBG TO EXIT IN AN | | | EMERGENCY? | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 6) SHEET 1.0 A - THE GARAGE IS CONSIDERED A PARKING | | | STRUCTURE AND SHOULD COMPLY WITH NFPA 88A AND BE | | | PROVIDED WITH VENTILATION. | | | | | | 3.3.272.7* PARKING STRUCTURE. A BUILDING, STRUCTURE, OR | | | PORTION | | | THEREOF USED FOR THE PARKING, STORAGE, OR BOTH, OF | | | MOTOR VEHICLES. | | | [88A, 2015] | | | | | | PER NFPA 42 STORAGE OCCUPANCIES | | | | | | 42.8 SPECIAL PROVISIONS FOR PARKING STRUCTURES. | | | 42.8.1 GENERAL REQUIREMENTS. | | | 42.8.1.1* APPLICATION. THE PROVISIONS OF 42.8.1 THROUGH | | | 42.8.5.4 | | | SHALL APPLY TO PARKING STRUCTURES OF THE CLOSED OR OPEN | | | TYPE, ABOVE | | | OR BELOW GRADE PLANE, BUT SHALL NOT APPLY TO ASSISTED | | | MECHANICALTYPE | | | OR AUTOMATED-TYPE PARKING FACILITIES THAT ARE NOT | | | OCCUPIED BY | | | CUSTOMERS. THE REQUIREMENTS OF SECTIONS 42.1 THROUGH | | | 42.7 SHALL | | | NOT APPLY. | | | 42.8.1.4 CLASSIFICATION OF OCCUPANCY. INCIDENTAL | | | VEHICLE PARKING | | | IN ANOTHER OCCUPANCY SHALL NOT BE THE BASIS FOR OVERALL | | | OCCUPANCY | | | CLASSIFICATION. | | | 42.8.1.5 CLASSIFICATION OF HAZARD OF CONTENTS. PARKING | | | STRUCTURES USED ONLY FOR THE STORAGE OF VEHICLES SHALL | | | BE CLASSIFIED | | | AS ORDINARY HAZARD IN ACCORDANCE WITH SECTION 6.2. | | | | | | NFPA 88A | | | | | | 6.3 VENTILATION. | | | 6.3.1* ALL ENCLOSED PARKING STRUCTURES SHALL BE | | | VENTILATED BY | | | A MECHANICAL SYSTEM CAPABLE OF PROVIDING A MINIMUM OF | | | 300 L/MIN PER M2 OF FLOOR AREA (1 FT3/MIN PER FT2 OF | | | FLOOR | | | AREA) DURING HOURS OF NORMAL OPERATION. | | | | | | 6.4 FIRE SPRINKLER SYSTEMS. | | | 6.4.1 AUTOMATIC SPRINKLER SYSTEMS SHALL CONFORM TO NFPA | | | 13. | | | 6.4.2 AUTOMATIC SPRINKLER SYSTEMS SHALL BE INSTALLED IN | | | PORTIONS | | | OF ENCLOSED PARKING STRUCTURES, THE CEILINGS OF WHICH | | | ARE | | | LESS THAN 600 MM (24 IN.) ABOVE GRADE, REGARDLESS OF | | | TYPE OF | | | CONSTRUCTION, AND IN ENCLOSED PARKING STRUCTURES OF | | | TYPE III OR | | | TYPE IV CONSTRUCTION OVER 15 M (50 FT) IN HEIGHT. | | | 6.4.3 AUTOMATIC SPRINKLER SYSTEMS SHALL BE INSTALLED IN | | | ENCLOSED | | | PARKING STRUCTURES LOCATED AT OR ABOVE GRADE, OR WITHIN | | | OR IMMEDIATELY BELOW A BUILDING USED FOR ANOTHER | | | OCCUPANCY. | | | | | | | | | PLEASE REVIEW AND COMPLY. | | | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-24 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-24 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2020-02-24 16:09:35 | GAS COMMENTS: APPROVED | | | CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR | | | MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL | | | GAS INSPECTION. | | | CALL 561-805-6692 FOR FURTHER INFORMATION. | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | 19120571 7310 GEORGIA AVE # 1 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-01-06 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-01-06 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2020-01-06 15:18:09 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | GAS COMMENTS: DENIED | | | 1. PLAN SHEET 1.1A KITCHEN EQUIPMENT SCHEDULE; BLANK | | | SPACE BETWEEN ITEM 1 AND ITEM 2 INDICATES ACTUAL | | | SERVICES REQUIRED IDENTICAL TO ITEM 1. ITEM 1 INDICATES | | | ONE (1) CONVECTION OVEN AT 90,000 BTUS. PLAN SHEET 3.0 | | | SHOWS TWO (2). PER WPB FBC 107.2.1 PLEASE CLARIFY. | | | 2. PER WPB FBC 107.2.1, SPECIFY THE TANKLESS WATER | | | HEATER AT THE LAVATORY AND PROVIDE MANUFACTURER?S | | | SPECIFICATION THE GAS TANKLESS WATER HEATER. | | | 3. PLAN PAGE 3.0P; GAS INSTA-HOT WATER HEATER DETAIL | | | INDICATES ONE VENT. THE UNIT SPECIFIED IS SEALED | | | COMBUSTION AND REQUIRES AN AIR INTAKE VENT AS WELL AS | | | AN EXHAUST VENT. PER WPB FBC 107.2.1, PROVIDE CORRECT | | | VENTING DETAILS, SUBMITTING A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE, TERMINATION POINT, HEIGHT ABOVE THE | | | ROOF AND ANCHORING DETAILS OF THE GAS VENT(S) COMPLYING | | | WITH FBC FG SECS. 502 THROUGH 505. | | | 4. PLAN PAGE 3.0P; PER WPB FBC 107.2.1, CORRECTLY | | | IDENTIFY THE EMERGENCY HOOD SHUT DOWN SHUT OFF VALVE. | | | VALVE SHALL BE LOCATED BELOW THE CEILING. THE MANUAL | | | SHUTOFF VALVE SHALL BE UPSTREAM. UNION TO BE DOWN | | | STREAM OF MANUAL VALVE AHEAD OF EMERGENCY SHUT OFF | | | VALVE. SECS. 10.4, 10.5 OF NFPA 96-08. SHOW LOCATION ON | | | THE PLAN VIEW | | | 5. PER WPB FBC 107.2.1, INDICATE PIPE MATERIAL AS NOTED | | | IN FBC FG TABLE 402.4(2). | | | 6. PER WPB FBC 107.2.1, SUBMIT CALCULATIONS FOR | | | COMBUSTION AIR PER FBC FG 304.1. | | | 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND FBC FG | | | 402.2 AND 301.3. GAS APPLIANCES SHALL BE LISTED AND | | | LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FBC FG 305.1. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19120571 7310 GEORGIA AVE # 1 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-14 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-13 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2020-07-13 14:20:55 | TO PV DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-03-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-02-12 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-12-13 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-05 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-05 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2020-08-05 16:24:33 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | IMPACT FEE REVIEW APPROVED: | | | | | | PALM BEACH COUNTY REVIEWED FOR IMPACT FEES. | | | PLANS STAMPED ON 7/23/2020 BY K. DWYER STATING NO FEES | | | DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-14 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-14 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2020-07-14 10:36:21 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | IMPACT FEES? PAPER SUBMITTALS. PLANS REQUIRE REVIEW BY | | | THE PBC IMPACT FEE OFFICE. CALL (561) 233?5025. UPON | | | APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO | | | THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND | | | WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE | | | PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT: | | | HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPAC | | | TFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-01-07 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-01-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2020-01-07 11:09:29 | IMPACT FEES- PAPER SUBMITTALS. PLANS REQUIRE REVIEW BY | | | THE PBC IMPACT FEE OFFICE. CALL (561) 233-5025. UPON | | | APPROVAL, YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO | | | THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED AND | | | WITH A COPY OF THE RECEIPT AS APPLICABLE. PLEASE | | | PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | THE PBC IMPACT FEE OFFICE. THE FORM CAN BE FOUND AT: | | | HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPAC | | | TFEES/FORMS/QUESTIONNAIRE.PDF | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2020-07-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-20 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-20 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2020-07-20 15:42:04 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | MECHANICAL REVIEW APPROVED WITH PROVISOS: | | | | | | 1) IF THE WELDING OPTION IS SELECTED FOR THE RTU STAND | | | CONNECTIONS THE FOLLOWING ARE REQUIRED TO BE APPROVED | | | BY THE DESIGNER OF RECORD: | | | AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | | BE USED. | | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | 2) AS PER SECTION FBC M 508.1.1, THE TEMPERATURE | | | DIFFERENTIAL BETWEEN THE MAKE?UP AIR AND THE | | | CONDITIONED SPACE MUST NOT EXCEED 10 DEGREES F. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-14 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-14 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2020-07-14 13:44:33 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | 4TH MECHANICAL REVIEW DENIED: | | | | | | FBC M 602.1 - 602.2, PLEASE PROVIDE THE DOOR DETAILS | | | FOR THE AIR HANDLER CLOSET AS THIS CLOSET APPEARS TO BE | | | A PLENUM. | | | | | | | | | PROVISOS: | | | | | | 1) IF THE WELDING OPTION IS SELECTED FOR THE RTU STAND | | | CONNECTIONS THE FOLLOWING ARE REQUIRED TO BE APPROVED | | | BY THE DESIGNER OF RECORD: | | | AWS D1.1 CLAUSE 3.1: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELD PROCEDURE SPECIFICATION; THE W.P.S. | | | SPECIFIES THE REQUIRED ESSENTIAL VARIABLES INCLUDING: | | | BASE MATERIALS, JOINTS, PROCESS, AND FILLER METALS TO | | | BE USED. | | | AWS D1.1 CLAUSE 4.15: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | | | | 2) AS PER SECTION FBC M 508.1.1, THE TEMPERATURE | | | DIFFERENTIAL BETWEEN THE MAKE-UP AIR AND THE | | | CONDITIONED SPACE MUST NOT EXCEED 10 DEGREES F. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-24 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-24 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2020-02-24 10:06:44 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #19120571 | | | 2/19/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ENERGY COMPLIANCE REPORT REQUIRED. | | | | | | A) THE PROPOSED BUSINESS OCCUPANCY IS A CHANGE OF | | | OCCUPANCY AND USE FROM THE PREVIOUS STORAGE WAREHOUSE | | | OCCUPANCY- SEE SECTION C505.1 FBC EC. | | | | | | B) SECTION C503.2 FBC EC CHANGE IN SPACE CONDITIONING. | | | ANY NONCONDITIONED OR LOW-ENERGY SPACE THAT IS ALTERED | | | TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE | | | BROUGHT INTO FULL COMPLIANCE WITH THIS CODE. | | | | | | REFER TO SECTION C101.5 AND C401.2 AND SUBMIT A | | | COMPLIANCE REPORT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-02-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-19 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-19 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2020-02-19 11:09:41 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19120571 | | | 2/19/20 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ENERGY COMPLIANCE REPORT REQUIRED. | | | | | | A) THE PROPOSED BUSINESS OCCUPANCY IS A CHANGE OF | | | OCCUPANCY AND USE FROM THE PREVIOUS STORAGE WAREHOUSE | | | OCCUPANCY- SEE SECTION C505.1 FBC EC. | | | | | | B) SECTION C503.2 FBC EC CHANGE IN SPACE CONDITIONING. | | | ANY NONCONDITIONED OR LOW-ENERGY SPACE THAT IS ALTERED | | | TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE | | | BROUGHT INTO FULL COMPLIANCE WITH THIS CODE. | | | | | | REFER TO SECTION C101.5 AND C401.2 AND SUBMIT A | | | COMPLIANCE REPORT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-12-31 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-12-31 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2019-12-31 17:08:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19120571 | | | 12/31/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO SECTION 301.1 FBC EX AND INDICATE WHAT | | | COMPLIANCE METHOD WILL BE CHOSEN FOR THE PROPOSED | | | OCCUPANCY. PLEASE NOTE THAT THE NEW COMMERCIAL KITCHEN | | | APPEARS TO BE A CHANGE OF OCCUPANCY AS DEFINED IN | | | SECTION 202, AND MAY REQUIRE SUBMITTAL OF ENERGY | | | CALCULATIONS- SECTION C505.1 FBC EC. | | | | | | 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW 5-TON SYSTEM IN ACCORDANCE WITH SECTION C403.2.1 | | | FBC EC. | | | | | | 3) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN | | | EXHAUST HOODS, FIRE SUPPRESSION SYSTEMS, AND THE WALK | | | IN COOLER- SECTION 107.2.1 WPB. PLEASE PLACE A BOLD | | | NOTE ON THE PLAN FOR CLARIFICATION. | | | | | | 4) SHEET 4.0M: PROVIDE MINIMUM VENTILATION CALCULATIONS | | | FOR ALL ROOMS AND SPACES PER TABLE 403.3.1.1 FBC M. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 5) SHEET 4.0M: PROVIDE AN AIR BALANCE CALCULATION- | | | SECTION 508.1.2 FBC M. | | | | | | 6) SHEET 4.0M: A DUCT SMOKE DETECTOR IS REQUIRED IN THE | | | SUPPLY AIR SYSTEM OF THE 5-TON AC SYSTEM PER SECTION | | | 606.2.1. PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED | | | IF THE MANUFACTURER'S PERFORMANCE DATA INDICATES THE | | | AIR HANDLER IS NOT CAPABLE OF PRODUCING OVER 2000 CFMS | | | OF SUPPLY AIR. | | | | | | 7) SHEET 4.0M: PROVIDE AN AUTOMATICALLY CONTROLLED | | | SHUTOFF DAMPER- GRAVITY OR MOTORIZED- FOR THE O/A | | | INTAKE DUCTS- SECTION C403.2.4.3 FBC EC. | | | | | | 8) SHEET 4.0M: A NON-COMBUSTIBLE DOOR FOR THE AC CLOSET | | | WILL BE REQUIRED IF THE RETURN IS NOT DUCTED DIRECTLY | | | TO THE AIR HANDLER- SEE SECTION 602.2.1 FBC M. | | | | | | 9) ADVISORY CONCERNING THE KITCHEN HOOD PERMIT: VERIFY | | | THAT THE TEMPERATURE DIFFERENTIAL BETWEEN THE EXHAUST | | | HOOD MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE | | | DOES NOT EXCEED 10 DEGREES F- SECTION 508.1.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-02-24 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-02-24 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2020-02-24 16:07:41 | PLUMBING COMMENTS: APPROVED | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | 19120571 7310 GEORGIA AVE # 1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-01-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2020-01-06 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2020-01-06 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2020-01-06 14:15:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. PER WPB FBC 107.2.1, PROVIDE SIZING PROCEDURE AND | | | CALCULATIONS AS CALLED OUT IN STD. PDI-G101 USED IN | | | DETERMINING THE GB-75 INTERCEPTOR. | | | 2. THE SPECIFIED FL1170 DOES NOT COMPLY WITH ASSE 1070 | | | AS REQUIRED BY FBC PL 416.5. PER WPB FBC 107.2.1, | | | REVISE AND RESUBMIT. | | | 3. SPECIFY THAT A WATER TEMPERING DEVICE SHALL BE | | | FURNISHED FOR THE LAVATORY IN ACCORDANCE WITH FBC PL | | | 416.5. | | | 4. PER WPB FBC 107.2.1, SPECIFY THE TANKLESS WATER | | | HEATER AT THE LAVATORY AND PROVIDE MANUFACTURER?S | | | SPECIFICATION FOR THE SAME. | | | 5. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S | | | SPECIFICATION FOR THE GAS TANKLESS WATER HEATER. | | | 6. WATER RISER MISTAKENLY IDENTIFIES SECTIONS OF COLD | | | WATER DISTRIBUTION AS HOT WATER WHICH IS FEEDING THE | | | TANKLESS WATER HEATER AS WELL AS THE HAND SINK AND MOP | | | SINK. EFFECTIVELY THERE IS NO HOT WATER TO THE HAND | | | SINK OR MOP SINK. PER WPB FBC 107.2.1, CORRECT AND | | | RESUBMIT. ADDITIONALLY, SHOW THE EXISTING COLD WATER | | | SUPPLY TO THE EXISTING BATHROOM. | | | 7. PLAN PAGE 3.0P GAS INSTA-HOT WATER HEATER DETAIL HAS | | | TWO NOTES: 1)WATER HEATER SET TO 140 DEGREES FOR | | | WAREWASH ONLY; 1)WATER HEATER SET TO 110 DEGREES FOR | | | HAND AND PREP SINKS ONLY. PER WPB FBC 107.2.1, PLEASE | | | CLARIFY. | | | 8. PER WPB FBC 107.2.1, SPECIFY FAUCET FOR MOP SINK | | | WHICH COMPLIES WITH FBC PL 608.2 BACKFLOW PROTECTION. | | | 9. PER WPB FBC 107.2.1, PROVIDE BACKFLOW PROTECTION IN | | | COLD WATER SUPPLY TO THE ICEMAKER TO COMPLY WITH FBC PL | | | 608.3. | | | 10. PLAN SHEET 1.1A KITCHEN EQUIPMENT SCHEDULE; ITEM | | | 16, WAREWASHER (DISHWASHER) CALLS FOR A 2 INCH INDIRECT | | | WASTE. PER WPB FBC 107.2.1, INDICATE ON THE SANITARY | | | ISOMETRIC THAT INDIRECT WASTE AND WHERE IT DISCHARGES | | | TO. COMPLY WITH FBC PL 802.1.7. ADDITIONALLY, INSURE | | | THAT THE QUANTITY AND THE LOCATIONS OF FLOOR SINKS ARE | | | THE SAME ON BOTH RISER AND FLOOR PLAN. | | | 11. A VENTED TRAP HAS BEEN PROVIDED AND IDENTIFIED AS A | | | FLOOR SINK/ DR (DISHTABLE?). THE EQUIPMENT SCHEDULE | | | CALL FOR A 1-1/2 INCH DIRECT CONNECTION TO THE | | | SANITARY. PER WPB FBC 107.2.1, CLARIFY THAT THE VENTED | | | TRAP IS PROVIDING THA AND IS NOT THE FLOOR SINK FOR THE | | | DISHWASHER. | | | 12. PER WPB FBC 107.2.1, PROVIDE INDIVIDUAL INDIRECT | | | WASTE FROM EACH WELL OF THE THREE-COMPARTMENT SINK | | | DISCHARGING INDEPENDENTLY TO THE FLOOR SINK TO COMPLY | | | FBC FL 802.1. | | | 13. PER WPB FBC 107.2.1, CLEARLY INDICATE HOW THE | | | DISPOSAL OF COOLER AND FREEZER EVAPORATOR CONDENSATE | | | WILL BE HANDLED. | | | 14. IF OCCUPANCY A-2 AND OCCUPANT LOAD CALCULATION IS | | | NOT DISPUTED BY THE BUILDING PLANS EXAMINER, THEN THE | | | FIXTURE REQUIREMENTS PER FBC PL SECTION 403 ARE | | | COMPLIED WITH. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19120571 7310 GEORGIA AVE # 1 | | | |
|
|
|