Plan Review Details - Permit 19120549
| Plan Review Stops For Permit 19120549 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-30 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-30 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2019-12-30 15:46:19 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19120549 | | | REVIEWED: DECEMBER 30, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[R] = FBC RESIDENTIAL | | | | | | 107.3.5 FBC[AMENDED]THERE IS A SHEET ON GRAPH PAPER | | | PROVIDED. PLEASE HAVE THE PERSON WHO DREW IT PUT THEIR | | | NAME ON IT. | | | ALSO, SHOW THE OUTLINE OF CONCRETE PAD THAT THE POST | | | WILL BE CONNECTED TO. | | | STATE THE DEPTH OF THE CONCRETE PAD AND THE DISTANCE | | | FROM EDGE THAT THE POST WILL BE PLACED, | | | | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-30 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-13 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2019-12-16 12:59:52 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-12-17 |
|
|
Cont ID |
|
| Sent By |
rfalcone |
Date |
2019-12-17 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rfalcone |
Date |
2019-12-17 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
| 2019-12-17 10:22:50 | 12/17/19 FAILED. | | | | | | THE PROPOSED METAL ROOF IS ENCROACHING WITHIN THE 25 | | | FOOT FRONT SETBACK. PLEASE REVISE TO COMPLY WITH ZONING | | | REGULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | | DEVELOPMENT SERVICES DEPARTMENT | | | E-MAIL: [email protected] | | | TEL: (561) 822-1442 |
|
|
|