| 2019-12-31 12:06:42 | PLEASE SUBMIT PLANS THAT WERE APPROVED BY RESOLUTION |
| | 351-19 FOR THE ARTIFICIAL TURF AS LISTED IN THE |
| | RESOLUTION |
| | SUBMITTED PLANS DO NOT MATCH AND DO NOT INCLUDE |
| | INFORMATION NEEDED FOR ARTIFICIAL TURF (IMPERVIOUS AREA |
| | CALCULATION) |
| | |
| | NEED FOLLOWING INFORMATION PER SECTION 94-451 - |
| | ARTIFICIAL TURF: |
| | |
| | - PROVIDE PERMEABILITY CALCULATIONS - MIN. PERMEABILITY |
| | IS 30 INCHES PER HOUR PER SQUARE YARD (INCLUDE EXACT |
| | MEASUREMENT FOR THIS REQUIREMENT) |
| | - REQUIRED TO HAVE MINIMUM EIGHT YEAR MANUFACTURER'S |
| | WARRANTY THAT PROTECTS AGAINST COLOR FADING AND |
| | DECREASE IN PILE HEIGHT (PROVIDE WARRANTY INFORMATION |
| | MEETING REQUIREMENT) |
| | - MUST BE COMPLETELY LEAD FREE (PROVIDE SPECIFIC |
| | STANDARD THAT SAYS SO) |
| | - ALL MATERIALS MUST INCLUDE TEST DOCUMENTATION WHICH |
| | DECLARES THAT THE ARTIFICIAL TURF YARN AND BACKING |
| | MATERIALS ARE DISPOSABLE UNDER NORMAL CONDITIONS, AT |
| | ANY US LANDFILL STATION (TOTAL CONTENT LEACH PROTOCOL |
| | (TCLP) TEST). |
| | - DOCUMENTATION MUST BE PROVIDED THAT IDENTIFIES ALL |
| | COMPONENTS THAT ARE RECYCLABLE AND ALL COMPONENTS THAT |
| | CONSIST OF RECYCLED MATERIAL. |
| | - AN APPROPRIATE SOLID BARRIER DEVICE (E.G., CONCRETE |
| | MOW STRIP, BENDER BOARD) IS REQUIRED TO SEPARATE |
| | ARTIFICIAL TURF FROM SOIL AND LIVE VEGETATION - PLEASE |
| | ILLUSTRATE MATERIAL TYPE AND LOCATION |
| | |
| | |
| | |
| | PLEASE NOTE REQURIED MAINTENACE AND REPAIR: |
| | |
| | (1)ALL ARTIFICIAL TURF SHALL, AT A MINIMUM, BE |
| | INSTALLED ACCORDING TO THE MANUFACTURER'S |
| | SPECIFICATIONS. |
| | (2)ALL ARTIFICIAL TURF INSTALLATIONS SHALL BE ANCHORED |
| | TO ENSURE THAT THE TURF WILL WITHSTAND THE EFFECTS OF |
| | WIND. |
| | (3)ALL SEAMS SHALL BE SECURED AND EDGES SHALL BE |
| | TRIMMED TO FIT AGAINST ALL REGULAR AND IRREGULAR EDGES |
| | TO RESEMBLE A NATURAL LOOK. |
| | (4)IF ARTIFICIAL TURF IS PLANNED TO BE INSTALLED |
| | IMMEDIATELY ADJACENT TO A SEAWALL, THE ARTIFICIAL TURF |
| | SHALL BE PINNED OR STAKED BEHIND THE SEAWALL. NO |
| | ARTIFICIAL TURF OR INSTALLATION MECHANISM SHALL BE |
| | ATTACHED DIRECTLY TO OR PLACED ON A SEAWALL OR SEAWALL |
| | CAP. (NOT APPLICABLE) |
| | (5)PROPER DRAINAGE SHALL BE PROVIDED FOR ALL ARTIFICIAL |
| | TURF INSTALLATIONS TO PREVENT EXCESS RUNOFF OR POOLING |
| | OF WATER. |
| | (6)ARTIFICIAL TURF SHALL BE VISUALLY LEVEL, WITH THE |
| | GRAIN POINTING IN A SINGLE DIRECTION. |
| | (7)AN APPROPRIATE SOLID BARRIER DEVICE (E.G., CONCRETE |
| | MOW STRIP, BENDER BOARD) IS REQUIRED TO SEPARATE |
| | ARTIFICIAL TURF FROM SOIL AND LIVE VEGETATION. |
| | (8)PRECAUTIONS FOR INSTALLATION AROUND EXISTING TREES |
| | SHALL BE MONITORED AND MAY BE RESTRICTED TO ENSURE TREE |
| | ROOTS ARE NOT DAMAGED WITH THE INSTALLATION OF THE BASE |
| | MATERIAL AND THAT THE OVERALL HEALTH OF THE TREE WILL |
| | NOT BE COMPROMISED |
| | (9)ALL ARTIFICIAL TURF SHALL BE MAINTAINED IN A GREEN |
| | FADELESS CONDITION AND SHALL BE MAINTAINED FREE OF |
| | DIRT, MUD, STAINS, WEEDS, DEBRIS, TEARS, HOLES, AND |
| | IMPRESSIONS. MAINTENANCE SHALL INCLUDE, BUT NOT BE |
| | LIMITED TO CLEANING, BRUSHING, DEBRIS REMOVAL; |
| | REPAIRING OF DEPRESSIONS AND RUTS TO MAINTAIN A |
| | VISUALLY-LEVEL SURFACE; ELIMINATION OF ANY ODORS, FLAT |
| | OR MATTED AREAS, WEEDS, AND INVASIVE ROOTS; AND ALL |
| | EDGES OF THE ARTIFICIAL TURF SHALL NOT BE LOOSE AND |
| | MUST BE MAINTAINED WITH APPROPRIATE EDGING OR STAKES. |
| | (10)ALL ARTIFICIAL TURF MUST BE REPLACED IF IT FALLS |
| | INTO DISREPAIR WITH FADING OR HOLES OR LOOSE AREAS. |
| | REPLACEMENT AND/OR REPAIRS SHALL BE DONE WITH LIKE FOR |
| | LIKE MATERIALS FROM THE SAME MANUFACTURER AND DONE SO |
| | IN A MANNER THAT RESULTS IN A REPAIR THAT BLENDS IN |
| | WITH THE EXISTING ARTIFICIAL TURF. |
| | |
| | |
| | LIZ LEVESQUE, URBAN DESIGN PLANNER |
| | [email protected] |
| | 561 822 1426 |