Plan Review Details - Permit 19120386
Plan Review Stops For Permit 19120386
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-03-09 Cont ID  
Sent By cpuell Date 2020-03-09 Time 16:48 Rev Time 0.00
Received By cpuell Date 2020-03-09 Time 16:48 Sent To  
Notes
2020-03-09 16:53:40REMODEL/ADDITION APPEARS TO BE CHANGING THE MAIN
 ENTRANCE TO THE PROPERTY, IT LOOKS LIKE THE ENTRANCE
 WILL BE FACING DOCK STREET, IF CORRECT A NEW ADDRESS
 WILL BE REQUIRED. PLEASE PROVIDE A SITE PLAN, SHOWING
 THE MAIN ENTRANCE. PLEASE CONTACT [email protected] OR
 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-27 Cont ID  
Sent By jgomez Date 2020-01-27 Time 15:25 Rev Time 0.00
Received By jgomez Date 2020-01-27 Time 09:57 Sent To  
Notes
2020-01-24 19:00:4001/30/2020 AS OF TODAY PLAN REVIEW FEES ARE NO PAID.
 TOLD SAMANTHA. BUILDING REVIEW WILL BE DONE WHEN PLAN
 REVIEW FEES ARE PAID. JG.
  
  
 PLAN REVIEW FEES ARE NO PAID. E-MAILED CONTRACTOR
 TWICE. JANUARY 23RD AND JANUARY 27TH.
 BUILDING REVIEW WILL BE DONE WHEN PLAN REVIEW FEES ARE
 PAID.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-01-08 Cont ID  
Sent By jleahy Date 2020-01-08 Time 08:07 Rev Time 0.00
Received By jleahy Date 2020-01-08 Time 08:07 Sent To  
Notes
2020-01-08 08:40:32FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E1.0
  
 1) GFCI REQUIRED FOR OUTLETS INSTALLED WITHIN 6' OF
 SINKS. 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER
 PROTECTION FOR PERSONNEL (B) OTHER THAN DWELLING UNITS.
 (5) SINKS ? WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8
 M (6 FT) OF THE OUTSIDE EDGE OF THE SINK.
  
 PAGE E2.0
  
 2) C405.2LIGHTING CONTROLS (MANDATORY). LIGHTING
 SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS SPECIFIED IN
 SECTIONS C405.2.1, C405.2.2, C405.2.3, C405.2.4 AND
 C405.2.5.
  
 3) ALL SYMBOLS NOT SHOWN ON PLANS SM?
  
 PAGE E3.0
  
 4) RISER DIAGRAM SHOWS 300 AMPERE SERVICE WITH 2/0
 CONDUCTORS.
  
 5) FAULT CURRENT RATING FOR SERVICE, HOW DID YOU
 CALCULATE THE AIC RATING?
  
 6) LOAD CALCULATION LIGHTING LOAD NOT PER 220.12.
 CHURCH 1VA SCHOOL 3VA PER SQFT
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2020-01-30 Cont ID  
Sent By jgomez Date 2020-01-30 Time 14:11 Rev Time 0.00
Received By jgomez Date 2020-01-30 Time 14:11 Sent To  
Notes
2020-01-30 14:12:12CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-12-18 Cont ID  
Sent By pleduc Date 2019-12-18 Time   Rev Time 0.00
Received By pleduc Date 2019-12-18 Time 12:05 Sent To  
Notes
2019-12-18 12:46:02THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET TS 1 - UNDER PROJECT INFORMATION THERE IS AN
 INDICATION OF CITY OF DELRAY BEACH.
  
 PLEASE REVIEW AND CORRECT.
  
  
 2) SHEET TS 1 - UNDER PROJECT INFORMATION/OCCUPANCY
 CLASSIFICATION THERE IS AN INDICATION OF ASSEMBY -
 RESTURAUNT.
  
 PLEASE REVIEW AND CORRECT.
  
  
 3) SHEET A 1.3 - THERE ARE INDICATIONS OF CLASSROOMS
 WHICH IS EDUCATIONAL PER THE FLORIDA FIRE PREVENTION
 CODE.
  
 IS THIS A MIXED OR SEPARATED OCCUPANCY?
  
 ARE THE CLASSROOMS JUST FOR SUNDAY ATTENDANCE?
  
 PER NFPA 101, CH 6 OCCUPANCY CLASSIFICATION
  
 6.1.14.2 DEFINITIONS.
 6.1.14.2.1 MULTIPLE OCCUPANCY. A BUILDING OR STRUCTURE
 IN WHICH TWO
 OR MORE CLASSES OF OCCUPANCY EXIST.
 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE
 THE
 OCCUPANCIES ARE INTERMINGLED.
 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY
 WHERE THE
 OCCUPANCIES ARE SEPARATED BY FIRE RESISTANCE?RATED
 ASSEMBLIES.
 6.1.14.3 MIXED OCCUPANCIES.
 6.1.14.3.1 EACH PORTION OF THE BUILDING SHALL BE
 CLASSIFIED AS TO ITS USE IN
 ACCORDANCE WITH SECTION 6.1.
 6.1.14.3.2* THE BUILDING SHALL COMPLY WITH THE MOST
 RESTRICTIVE
 REQUIREMENTS OF THE OCCUPANCIES INVOLVED, UNLESS
 SEPARATE SAFEGUARDS
 ARE APPROVED.
 6.1.14.4 SEPARATED OCCUPANCIES. (SEE ALSO 6.1.14.1.2.)
 6.1.14.4.1 WHERE SEPARATED OCCUPANCIES ARE PROVIDED,
 EACH PART OF THE
 BUILDING COMPRISING A DISTINCT OCCUPANCY, AS DESCRIBED
 IN THIS CHAPTER,
 SHALL BE COMPLETELY SEPARATED FROM OTHER OCCUPANCIES BY
 FIRE-RESISTIVE
 ASSEMBLIES, AS SPECIFIED IN 6.1.14.4.2, 6.1.14.4.3,
 TABLE 6.1.14.4.1(A),
 AND TABLE 6.1.14.4.1(B), UNLESS SEPARATION IS PROVIDED
 BY APPROVED
 EXISTING SEPARATIONS OR AS OTHERWISE PERMITTED BY
 6.1.14.4.6.
  
 PLEASE REVIEW AND CLARIFY AND PROVIDE APPLICABLE
 CONSTRUCTION SEPARATION DETAILS. OR JUSTIFY WITH
 SEPECIFIC CODE REFERENCES AND DETAILED NARRATIVE.
  
  
 3A) ARE THE CLASSROOMS JUST FOR SUNDAY ATTENDANCE?
  
 PER NFPA 101, CH 6 OCCUPANCY CLASSIFICATION
  
 6.1.3 EDUCATIONAL. FOR REQUIREMENTS, SEE CHAPTERS 14
 AND 15.
 6.1.3.1* DEFINITION ? EDUCATIONAL OCCUPANCY. AN
 OCCUPANCY USED
 FOR EDUCATIONAL PURPOSES THROUGH THE TWELFTH GRADE BY
 SIX OR MORE
 PERSONS FOR 4 OR MORE HOURS PER DAY OR MORE THAN 12
 HOURS PER WEEK.
 6.1.3.2 OTHER OCCUPANCIES. OTHER OCCUPANCIES ASSOCIATED
 WITH
 EDUCATIONAL INSTITUTIONS SHALL BE IN ACCORDANCE WITH
 THE APPROPRIATE PARTS
 OF THIS CODE.
 6.1.3.3 INCIDENTAL INSTRUCTION. IN CASES WHERE
 INSTRUCTION IS INCIDENTAL
 TO SOME OTHER OCCUPANCY, THE SECTION OF THIS CODE
 GOVERNING SUCH OTHER
 OCCUPANCY SHALL APPLY.
  
 PLEASE A DETAILED NARRATIVE OF CLASSROMM FUNCTION.
  
  
 4) SHEET A 2.1 - TWO DOORS, 105 & 106 OPEN INTO THE
 EXIT CORRIDOR.
  
 PER NFPA 101, CH 7, MEANS OF EGRESS.
  
 PER NFPA 101 CHAPTER 7, MEANS OF EGRESS
 7.2.1.4.3 DOOR LEAF ENCROACHMENT
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE
 REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY,
 OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT
 MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A
 CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN,
 UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS
 PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED
 WIDTH OF THE STAIR LANDING WHEN THE DOOR
 LEAF IS FULLY OPEN.
  
 PLEASE REVIEW AND CORRECT.
  
  
 5) SHEET A 2.1 & S 2.0 - THE SMALL CORRIDOR SHOWS
 DIFFERENT MEASURMENTS, 3'11" AND 4'1" RESPECTIVELY AND
 5'11" & 6'1".
  
 WHICH SET OF MEASURMENTS IS CORRECT?
  
 PLEASE CORRECT OR JUSTIFY.
  
  
 6) SHEET A 2.1 - THE DOOR SCHEDULE DOES NOT INDICATE
 HARDWARE, EXIT HARDWARE(PANIC), LOCKS/LATCHES, ETC.
  
 PER NFPA 101, CH 12 & 7
  
 12.2.2 MEANS OF EGRESS COMPONENTS.
 12.2.2.1 COMPONENTS PERMITTED. COMPONENTS OF MEANS OF
 EGRESS
 SHALL BE LIMITED TO THE TYPES DESCRIBED IN 12.2.2.2
 THROUGH 12.2.2.12.
 12.2.2.2 DOORS.
 12.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
 12.2.2.2.2 ASSEMBLY OCCUPANCIES WITH OCCUPANT LOADS OF
 300 OR LESS IN
 MALLS (SEE 36.4.4.4.2(4) SHALL BE PERMITTED TO HAVE
 HORIZONTAL OR VERTICAL
 SECURITY GRILLES OR DOORS COMPLYING WITH 7.2.1.4.1(3)
 ON THE MAIN
 ENTRANCE/EXITS.
 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM
 AN AREA HAVING
 AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE
 PERMITTED TO BE
 PROVIDED WITH A LATCH OR LOCK ONLY IF THE LATCH OR LOCK
 IS PANIC
 HARDWARE OR FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7,
 UNLESS
 OTHERWISE PERMITTED BY ONE OF THE FOLLOWING:
 (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS
 LOCKS AS
 PERMITTED IN 12.2.2.2.5.
 (2) THIS REQUIREMENT SHALL NOT APPLY TO
 ACCESS-CONTROLLED EGRESS DOORS
 AS PERMITTED IN 12.2.2.2.6.
 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5
 SHALL BE PERMITTED
 TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS
 IF BOTH OF THE
 FOLLOWING CONDITIONS APPLY:
 (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT
 AND THE ASSEMBLY
 OCCUPANCY HAS AN OCCUPANT LOAD NOT GREATER THAN 500.
 (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN
 ASSEMBLY
 OCCUPANCY HAVING AN OCCUPANT LOAD OF 100 OR MORE ARE
 RELEASED
 BY PANIC HARDWARE OR FIRE EXIT HARDWARE.
  
 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES.
 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED
 READILY FROM
 THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED.
 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY
 TO DOOR
 LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER EXPOSURE TO
 ELEVATED
 TEMPERATURE IN ACCORDANCE WITH THE LISTING, BASED ON
 LABORATORY
 FIRE TEST PROCEDURES.
 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE
 OF A KEY, A
 TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM
 THE EGRESS
 SIDE.
 7.2.1.5.4 THE REQUIREMENTS OF 7.2.1.5.1 AND 7.2.1.5.3
 SHALL NOT
 APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 18 THROUGH
 23.
 7.2.1.5.5 KEY-OPERATED LOCKS.
 7.2.1.5.5.1* EXTERIOR DOOR ASSEMBLIES SHALL BE
 PERMITTED TO HAVE
 KEY-OPERATED LOCKS FROM THE EGRESS SIDE, PROVIDED THAT
 ALL OF THE
 FOLLOWING CRITERIA ARE MET:
 (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11
 THROUGH 43 FOR
 THE SPECIFIC OCCUPANCY.
 (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS
 THAN 1 IN.
 (25 MM) HIGH ON A CONTRASTING BACKGROUND THAT READS AS
 FOLLOWS IS LOCATED ON OR ADJACENT TO THE DOOR LEAF:
 THIS
 DOOR TO REMAIN UNLOCKED WHEN THE
 BUILDING IS OCCUPIED.
 (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY
 DISTINGUISHABLE
 AS LOCKED.
 (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT
 INSIDE THE
 BUILDING WHEN IT IS LOCKED.
  
 PLEASE REVIEW AND CORRECT AND ENSURE COMPLIANCE.
  
  
 7) SHEET S 3.0 - THE ROOF TRUSS DESIGN IS UNCLEAR.
  
 PLEASE CLARIFY AND IF APPLICABLE PROVIDE A LIGHTWEIGHT
 FRAME SIGN PER STATE LAW.
  
 PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR
 STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION.
 ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT
 RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES
 HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE
 CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A
 MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND
 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR.
 THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO
 THE LEFT OF THE MAIN ENTRY DOOR.
 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE
 MARKED WITH THE LETTER "R".
 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS
 SHALL BE MARKED WITH THE LETTER "F".
 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF
 SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F".
  
  
  
 8) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 9) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-30 Cont ID  
Sent By jgomez Date 2020-01-30 Time 14:12 Rev Time 0.00
Received By jgomez Date 2019-12-10 Time 15:02 Sent To I
Notes
2019-12-11 15:02:49C13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-01-24 Cont ID  
Sent By jgomez Date 2020-01-24 Time 18:18 Rev Time 0.00
Received By jgomez Date 2020-01-24 Time 18:17 Sent To  
Notes
2020-01-24 18:18:34IMPACT FEES -
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK
 OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW.
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-08 Cont ID  
Sent By ccole Date 2020-01-08 Time 14:58 Rev Time 0.00
Received By ccole Date 2020-01-08 Time 12:21 Sent To  
Notes
2020-01-08 15:30:091ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120386
 1/8/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW AC SYSTEMS- SECTION C403.2.1 FBC EC.
  
 2) PROVIDE AN ENERGY COMPLIANCE REPORT FOR THE NEW
 ADDITIONS TO THE BUILDING- SECTION C502.1 AND C101.5.1
 FBC EC.
  
 3) REFER TO SECTION 809.2 FBC EX AND PROVIDE MINIMUM
 VENTILATION CALCULATIONS FOR ALL EXSITNG AND NEW ROOMS
 AND SPACES PER TABLE 403.3.1.1 FBC M. PROVIDE A
 SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED CFMS
 OF OUTDOOR AIR.
  
 4) SHEET M-1.0: INDICATE HOW THE REQUIRED OUTSIDE AIR
 IS BEING PROVIDED TO THE EXISTING AND NEW ROOMS AND
 SPACES- SEE SECTION 402 & 403 FBC M. PLEASE NOTE THAT
 PROVIDE AUTOMATICALLY CONTROLLED SHUTOFF DAMPERS ARE
 REQUIRED FOR O/A INTAKE DUCTS- SECTION C403.2.4.3 FBC
 EC.
  
 5) M-1.0: RETURN AIR SYSTEMS NOT SHOWN- SECTION 601.6
 FBC M.
  
 6) M-1.0 & M-2.0: THE AC EQUIPMENT IS INCORRECTLY
 INDICATING THE SYSTEMS ARE FOR 2ND FLOOR BEDROOMS-
 PLEASE CORRECT.
  
 7) M-1.0 & M-2.0: THE 1600 CFM CAPACITIES FOR THE 4-TON
 SYSTEMS SHOWN IN THE SCHEDULE ARE UNDERIZED COMPARED TO
 THE CFMS BEING DISTRIBUTED ON THE AC LAYOUT PLAN. THESE
 APPEAR TO BE MUCH LARGER SYSTEMS WHICH WILL ALSO
 REQUIRE DUCT SMOKE DETECTORS ION THE MAIN SUPPLY DUCTS-
 SECTION 606.2.1 FBC M.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS. PLEASE NOTE THAT REVIEW
 OF RESUBMITTED CORRECTED PLANS MAY RESULT IN ADDITIONAL
 COMMENTS. ADDITIONAL COMMENTS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-31 Cont ID  
Sent By gjohnson Date 2019-12-31 Time 12:11 Rev Time 0.00
Received By gjohnson Date 2019-12-30 Time 12:33 Sent To  
Notes
2019-12-31 12:12:301ST REVIEW: 19120386
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. TS-1 IN THE RESTROOM FIXTURE CALCULATION ARE
 INCORRECT UNDER THE MENS IT SHOULD BE 1 PER 150 NOT 1
 PER 75. PER FBC PL TABLE 403.1 A3
  
 2.GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE. PER FBC ACC 609.4
  
 3. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. PER FBC ACC 603.3
  
 4. SHT.TS-1 THE RESTROOM FIXTURE CALCULATIONS ARE
 LISTING 2 TOILETS , 1 LAVATORY FOR WOMEN 2 TOILETS, 1
 LAVATORY FOR MEN THE FLOOR PLAN SHOWS 3 TOILETS, 3
 LAVATORY'S FOR MEN AND 3 TOILETS, 3 LAVATORY'S FOR
 WOMEN PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 5. SHT-0.1 SHOWS DETAILS FOR SHOWERS NO SHOWERS ARE
 SHOWN ON THE PLAN PLEASE CLARIFY OR REMOVE ANY DETAILS
 THAT ARE NOT BEING USED. PER WPB AMEND TO FBC 107.2.1
  
 6. SHOW COMPLIANCE WITH FBC ACC 604.2 LOCATION. THE
 WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM
 TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR
 PARTITION,
  
 7. SHT. A-2.3 SHOW COMPLIANCE WITH FBC ACC 603.3
 MIRRORS. MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
  
 8. AT LEAST ONE OF THE LAVATORY'S OUTSIDE OF THE
 ACCESSIBLE STALL SHALL COMPLY WITH FBC ACC 213.3.4,
 606.2, 606.3
  
 9. SHT.P-1.0 THE SANITARY ISOMETRIC AND FLOOR PLAN IS
 SHOWING A HORIZONTAL DRY VENT WHICH IS A CODE VIOLATION
 EACH TOILET SHOULD CONNECT TO THE BRANCH DRAIN
 SEPARATELY AND COMPLY WITH FBC PL 905.3, 905.4, 914.1
  
 10. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5
  
 11. A WATER FOUNTAIN IS REQUIRED. PER FBC PL TABLE
 403.1
  
 12. A SERVICE SINK IS REQUIRED. PER FBC PL TABLE 403.1
  
 13. ON THE WATER ISOMETRIC SHUT OFF VALVES ARE REQUIRED
 ON ALL THE HOT AND COLD DROPS. PER FBC PL 606.1(5)
  
 14. A HOT WATER RECIRCULATION SYSTEM IS REQUIRED THE
 DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING, FROM
 THE SOURCE OF HOT WATER TO THE FIXTURES THAT REQUIRE
 HOT OR TEMPERED WATER, SHALL NOT EXCEED 50 FEET (15 240
 MM). RECIRCULATING SYSTEM PIPING AND HEAT-TRACED PIPING
 SHALL BE CONSIDERED TO BE SOURCES OF HOT OR TEMPERED
 WATER. PER FBC PL 607.2
  
 END OF COMMENTS
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-01-27 Cont ID  
Sent By jgomez Date 2020-01-27 Time 15:24 Rev Time 0.00
Received By jgomez Date 2020-01-27 Time 15:24 Sent To  
Notes
2020-01-27 15:25:22PLAN REVIEW FEES ARE NO PAID. E-MAILED CONTRACTOR
 TWICE. JANUARY 23RD AND JANUARY 27TH.
 BUILDING REVIEW WILL BE DONE WHEN PLAN REVIEW FEES ARE
 PAID.

Review Stop Z ZONING
Rev No 1 Status F Date 2019-12-16 Cont ID  
Sent By llouie Date 2019-12-16 Time   Rev Time  
Received By llouie Date 2019-12-16 Time   Sent To  
Notes
2019-12-16 14:59:02** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) EXPANSION/ADDITION OF THE EXISTING USE REQUIRES A
 CLASS B SPECIAL USE PERMIT, TO BE APPROVED BY THE
 ZONING BOARD OF APPEALS.
  
  
 NOTES:
  
 * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * SCOPE OF WORK: INTERIOR REMODEL AND BUILDING ADDITION
 (CLASSROOMS).
  
 * EXISTING RELIGIOUS INSTITUTION: IGLESIA EVANGELICA DE
 SANTIDAD (FEA MINISTRIES).
  
 * ZONE: SF14
  