Plan Review Details - Permit 19120383
Plan Review Stops For Permit 19120383
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-10-13 Cont ID  
Sent By pvalenti Date 2020-10-13 Time 17:44 Rev Time 0.00
Received By pvalenti Date 2020-10-13 Time 17:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-02-21 Cont ID  
Sent By pvalenti Date 2020-02-21 Time 09:17 Rev Time 0.00
Received By pvalenti Date 2020-02-21 Time 09:17 Sent To  
Notes
2020-02-21 09:23:27***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC B/WPB AMENDMENTS, 107.1 AND 107.2.1 PLEASE PROVIDE
 (2) SETS OF ALL SUBMITTED DOCUMENTS AND HAVE ALL
 DOCUMENTS SIGNED AND SEALED BY THE DESIGN PROFESSIONAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-27 Cont ID  
Sent By pvalenti Date 2019-12-27 Time 13:38 Rev Time 0.00
Received By pvalenti Date 2019-12-27 Time 13:38 Sent To  
Notes
2019-12-27 13:52:25***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 BUILDING REVIEW DENIED:
  
 FBC 107.2.1
 1. PROVIDE PARKING SPACE STRIPING DETAILS (WITH
 MEASUREMENTS) INCLUDING WIDTHS OF ALL STALLS AND
 ACCESSIBLE AISLE.
 2. PROVIDE DISABLED PARKING SIGN DETAILS INCLUDING
 LOCATION.
 3. REMOVE CITY OF OAKLAND PARK FROM ITEM # 17 OF
 SPECIFICATIONS ON PAGE CE1

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2020-10-15 Cont ID  
Sent By Mgonzale Date 2020-10-15 Time   Rev Time 1.00
Received By mgonzale Date 2020-10-15 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2020-02-19 Cont ID  
Sent By rrossano Date 2020-02-19 Time   Rev Time 0.00
Received By rrossano Date 2020-02-19 Time   Sent To I
Notes
2020-02-19 07:06:311. SURVEY IS MORE THAN 3 YEARS OLD. THERE HAS BEEN
 CONSTRUCTION ON THE PROPERTY (NEW BUILDING) SINCE THE
 SURVEY WAS COMPLETED.
 2. NOTE 8 ON THE SURVEY NEEDS TO BE UPDATED. REVISED
 FEMA MAPS WERE ISSUED A FEW YEARS AGO.
 3. THE SURVEY AND ENGINEERING PLANS USE NGVD1929. THE
 DRAINAGE CALCULATIONS REFERENCE NAVD1988.
 4. I COULD NOT FIND SECTION A-A OR SECTION B-B ON THE
 PGD PLAN (SHEET CE1).
 5. THE SIDE SLOPES AND BOTTOM WIDTH OF THE SWALE NEED
 TO BE DIMENSIONED ON THE TWO SECTIONS ON PGD PLAN
 (SHEET CE1).
 6. THE DRIVE LANE BETWEEN THE TWO BUILDINGS WILL FLOOD
 BEFORE THE DETENTION PONDS OVER TOP AND DRAIN TO THE
 ROAD.
 7. DRAINAGE CALCULATIONS NEED TO PROVIDE PRE- VS POST-
 DISCHARGE OR RUNOFF CALCULATIONS LEAVING THE SITE.
 8. CONSIDER REDUCING THE DEPTH OF THE PARKING SPACES
 AND PROVIDE TWO FEET OF OVERHANG. WHEEL STOPS WILL NOT
 BE NEEDED IF RAISED CURB IS USED.
  
 NOTE THE NAVD1988/NGVD1929 CONVERSION EQUATION IS NOT
 NEEDED IF NGVD1929 (CITY?S OFFICIAL VERTICAL DATUM) IS
 USED.
  
 WITH REGARDS,
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS ST., 4TH FLOOR
 WEST PALM BEACH, FL 33401
 PHONE: 561-494-1120
 FAX: 561-494-1116
 CELL 561-351-0510
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-12-16 Cont ID  
Sent By rrossano Date 2019-12-16 Time   Rev Time  
Received By rrossano Date 2019-12-16 Time   Sent To B
Notes
2019-12-16 07:10:521) ON PLANS, PLEASE ADD NOTE TO CLEARLY SHOW BOTH
 EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS AREA
 CALCULATIONS.
  
 2) ON PLANS, PLEASE PROVIDE VERTICAL DATUM AND DATUM
 CONVERSION INFORMATION (NAVD 1988 AND NGVD 1929).
  
 3) PLEASE REVISE NOTE 17 REFERRING TO CITY OF OAKLAND
 PARK STANDARDS. CONFIRM ALL OTHER NOTES AND DETAILS
 COMPLY WITH CITY OF WEST PALM BEACH STANDARDS.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR WPB, FL 33401 (MAILING
 ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098
 FAX: (561) 494-1116 MOBILE: (561) 246-9525
 EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-10-16 Cont ID  
Sent By jleahy Date 2020-10-16 Time 10:50 Rev Time 0.00
Received By jleahy Date 2020-10-02 Time 14:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-21 Cont ID  
Sent By pvalenti Date 2020-02-21 Time 09:23 Rev Time 0.00
Received By pvalenti Date 2020-01-14 Time 13:52 Sent To  
Notes
2020-02-19 18:39:40RESUB ROUTED TO PVALENTI
2020-01-25 08:37:02ROUTED TO ENGINEERING
2020-01-15 13:52:47RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-27 Cont ID  
Sent By pvalenti Date 2019-12-27 Time 13:52 Rev Time 0.00
Received By pvalenti Date 2019-12-10 Time 13:27 Sent To  
Notes
2019-12-11 13:28:03ROUTED TO ZONING INBOX

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-05 Cont ID  
Sent By dbattles Date 2020-10-05 Time 09:42 Rev Time 0.00
Received By dbattles Date 2020-10-05 Time 09:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2020-10-09 Cont ID  
Sent By rthermid Date 2020-10-09 Time   Rev Time 0.00
Received By rthermid Date 2020-10-09 Time   Sent To I
Notes
2020-10-09 11:12:32NO CHANGES TO EXISTING PARKING LAYOUT.

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-23 Cont ID  
Sent By rfalcone Date 2020-01-23 Time 09:41 Rev Time 0.00
Received By rfalcone Date 2020-01-23 Time 09:41 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-12-13 Cont ID  
Sent By rfalcone Date 2019-12-13 Time 09:23 Rev Time 0.00
Received By rfalcone Date 2019-12-13 Time 09:23 Sent To ENG
Notes
2019-12-13 09:42:5812/13/19 FAILED.
  
 PLEASE PROVIDE THE DIMENSIONS OF THE PROPOSED PARKING
 SPACES WITH A PARKING DETAIL, THE DRIVEWAY, AND THE
 CROSSING.
  
 THE PROPOSED PARKING LOT WILL NEED TO COMPLY WITH THE
 LANDSCAPING REGULATIONS. PURSUANT ZLDR SEC.
 94-443(C)(1-3), SCREENING AND LANDSCAPING FOR VEHICULAR
 USE AREAS.
 HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C
 ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXIVLA
 LACLTRPRARTU_S94-443NOMUSCBURE
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT HTTPS://WPB.ORG/DEPARTME
 NTS/DEVELOPMENT-SERVICES/OVERVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 E-MAIL: [email protected]
 TEL: (561) 822-1442
  