Plan Review Details - Permit 19120250
| Plan Review Stops For Permit 19120250 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-12-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-12-18 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-12-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-12-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-12-13 |
Time |
11:43 |
Sent To |
P |
|
| Notes |
| 2019-12-13 11:44:06 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) UNDERGROUND PIPING IS INDICATED. | | | | | | PER NFPA 13D | | | | | | 5.3* UNDERGROUND PIPE. ANY TYPE OF PIPE OR TUBE | | | ACCEPTABLE | | | UNDER THE APPLICABLE PLUMBING CODE FOR UNDERGROUND | | | SUPPLY | | | PIPE SHALL BE ACCEPTABLE AS AN UNDERGROUND SUPPLY FOR A | | | FIRE | | | SPRINKLER SYSTEM WHEN INSTALLED BETWEEN THE POINT OF | | | CONNECTION | | | AND THE SYSTEM RISER. | | | | | | PLEASE ENSURE COMPLIANCE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-12-18 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-12-06 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2019-12-09 14:00:44 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-12-18 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-12-17 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2019-12-17 16:13:07 | 12/17/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-701-6437 | | | |
|
|
|