Plan Review Details - Permit 19120250
Plan Review Stops For Permit 19120250
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2019-12-18 Cont ID  
Sent By rrossano Date 2019-12-18 Time   Rev Time 0.00
Received By rrossano Date 2019-12-18 Time   Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-12-13 Cont ID  
Sent By pleduc Date 2019-12-13 Time   Rev Time 0.00
Received By pleduc Date 2019-12-13 Time 11:43 Sent To P
Notes
2019-12-13 11:44:06THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) UNDERGROUND PIPING IS INDICATED.
  
 PER NFPA 13D
  
 5.3* UNDERGROUND PIPE. ANY TYPE OF PIPE OR TUBE
 ACCEPTABLE
 UNDER THE APPLICABLE PLUMBING CODE FOR UNDERGROUND
 SUPPLY
 PIPE SHALL BE ACCEPTABLE AS AN UNDERGROUND SUPPLY FOR A
 FIRE
 SPRINKLER SYSTEM WHEN INSTALLED BETWEEN THE POINT OF
 CONNECTION
 AND THE SYSTEM RISER.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-18 Cont ID  
Sent By lcrespo Date 2019-12-18 Time 13:42 Rev Time 0.00
Received By lcrespo Date 2019-12-06 Time 14:00 Sent To  
Notes
2019-12-09 14:00:44ROUTED TO FIRE INBOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-12-18 Cont ID  
Sent By lcrespo Date 2019-12-18 Time 13:42 Rev Time 0.00
Received By lcrespo Date 2019-12-17 Time 16:12 Sent To  
Notes
2019-12-17 16:13:0712/17/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  