| Plan Review Stops For Permit 19120213 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-19 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-19 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-03 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-31 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2020-01-03 13:36:51 | PLAN REVIEW - BUILDING | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SEE PLAN PAGE A.01 CHANGE LEVEL OF ALTERATION FROM | | | LEVEL 2 TO LEVEL 3 PER FBC R EXISTING SECTION 505. | | | 505.1 SCOPE. LEVEL 3 ALTERATIONS APPLY WHERE THE WORK | | | AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA. | | | | | | 2. DEMENSIONS OF STRUCTURE ON SURVEY AND ARCH. SITE | | | PLAN DON'T MATCH. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. SEE PLAN PAGE A.02 DESCRIBE WHICH WINDOW WILL BE | | | INSTALLED IN WINDOWS W1 AND W2. REFERENCE SPECIFIC NOA | | | FOR EACH WIND TYPE. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PROVIDE FINISHED FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | | | | 5. LANDINGS ARE REQUIRED AT EXTERIOR DOORS. | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS. | | | R311.3.2 FLOOR ELEVATIONS FOR OTHER EXTERIOR DOORS. | | | | | | 6. SEE PLAN PAGES A.02 AND A.05 WINDOW MARK ON WINDOW | | | AND DOOR WIND PRESSURE SCHEDULE DOES NOT MATCH WINDOW | | | NUMBER ON WINDOW SCHEDULE. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 7. PROVIDE ICC ES REPORT FOR ICYNENE SPRAY INSULATION. | | | DESIGNER TO SELECT PRODUCT TO BE USED. PROVIDE | | | INSTALLATION INSTRUCTIONS AT TIME OF INSPECTION. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-19 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-19 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-27 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-27 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2019-12-27 11:23:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ONLY ONE SERVICE PER ADDRESS IS PERMITTED. PROVIDE | | | CORRECTION. WPB FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | 2. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 3. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 5. PLAN SHOWS ONE SMALL APPLIANCE CIRCUIT FOR KITCHEN | | | RECEPTACLE OUTLETS. A MINIMUM OF TWO 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY KITCHEN COUNTERTOP | | | RECEPTACLE OUTLET(S). PROVIDE CORRECTION. NEC | | | 210.11(C)(1) , FBC RE E3703.2 | | | 6. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 8. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; WPB FBC 107.2.1 | | | 9. PROVIDE ACCURATE LOAD CALCULATION FOR EXISTING | | | SERVICE, INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 10. PROVIDE LOCATION OF ELECTRICAL PANEL ON PLAN TO | | | CONFIRM CODE COMPLIANCE. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-13 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-13 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2020-08-13 12:54:13 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | | | | NOTE: THE CITY OF WEST PALM BEACH HAS NO RECORD OF | | | EXISTING GAS. A FULL EVALUATION OF ALL GAS EQUIPMENT | | | WILL BE DONE AT FIELD, IF NOT TO CODE, IT MAY NEED TO | | | BE BOUT UP TO CODE COMPLIANCE. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-11 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-08-27 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-08-27 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2020-08-27 14:44:49 | COMMENTS FROM 1ST REVIEW NOT ADDRESSED |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-12-23 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-12-23 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2019-12-23 11:36:03 | PROPERTY IN HSITORIC DISTRICT, REQUIRES HPB APPROVAL OF | | | COA FOR OPENING MODIFICATIONS AND HARDI BOARD. | | | | | | QUESTIONS, CONTACT: FRIEDERIKE MITTNER, CITY HSITORIC | | | PRESERVATION PLANNER AT 822-1457 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-02-01 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-29 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-12-21 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-12-07 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-09-05 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-08-08 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-03 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-05 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-02-01 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-29 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2021-02-01 14:20:05 | NO FEES DUE PER IMPACT OFFICE. SEE UPLOADED EMAIL. LEM | | 2021-01-29 11:44:55 | 010/29/21 EMAILED IMACT FEE OFFICE, QUESTIONNAIRE | | | UPLOADED I N PD. CC |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-03 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-03 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2020-01-03 13:38:01 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-01 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-01 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2020-08-10 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2020-08-10 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2020-08-10 08:15:06 | PLAN DENIED | | | 1) PROVIDE EQUIPMENT SCHEDULE ON PLANS | | | SECTION 107 FBC 2017 | | | 2) PROVIDE CFM ON ALL SUPPLY DUCTS. SECTION | | | 107 FBC 2017 | | | 3) HEATING AND COOLING LOADS REQUIRED.SECTION | | | 312 FBC (M) 2017 | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-03 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-31 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2020-01-03 14:18:19 | PLAN REVIEW - MECHANICAL | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SERVICE DISCONNECT FOR CU ON PLAN PAGE E.01 SHALL BE | | | 220 VOLT. | | | PANEL SCHEDULE: | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 2. INDICATE THE SIZE OF THE RETURN DUCTS FROM THE RAG'S | | | TO THE AIR HANDLER- SHOW DUCTS ON PLAN. | | | SECTION M1602.2 FBC RES. | | | | | | 3. PROVIDE ENGINEERING FOR INSTALLATION OF THE | | | CONDENSER PAD AND MOUNTING OF THE CONDENSER- SECTIONS | | | M1305.1.4.1 AND M1401.4 FBC RES. | | | | | | 4. PROVIDE LOCKING ACCESS PORT CAPS. | | | M1411.8 LOCKING ACCESS PORT CAPS. | | | | | | 5. PROVIDE ENERGY SUBMITTAL | | | R405.2 EC. | | | | | | 6. PROVIDE MANUAL J WORSHEETS WITH AC SYSTEM SIZING | | | CALCULATIONS. | | | SECTION R403.7.1 FBC EC. | | | | | | 7. PROVIDE EQUIPMENT SCHEDULE ON PLAN. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 8. EXHAUST VENTILATION AT A RATE OF 100 CFMS | | | INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED | | | FOR THE KITCHEN. | | | TABLE M1507.4 FBC RES. PLEASE SEE SECTION M1503.1 FOR | | | RANGE HOOD REQUIREMENTS, AND M1503.4 FOR MAKEUP AIR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-08-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-08-13 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-08-13 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2020-08-13 12:26:50 | 08/13/20 REVIEWED FOR CODE COMPLIANCE | | | (PLUMBING/BACKFLOW) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, | | | CONTRACTORS OR THEIR REPRESENTATIVES FROM THE | | | RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-12-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2019-12-09 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2019-12-09 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2019-12-09 15:21:01 | 12/09/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-701-6437 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-08-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-19 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-19 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-08-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-08-08 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-08-08 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2020-08-08 06:57:44 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | SIGNATURE REVIEW APPROVED BY DIGITAL AND ORIGINAL PAPER | | | PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-11 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-08-27 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-08-27 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2020-08-27 14:45:16 | COMMENTS FORM 1ST REVIEW NOT ADDRESSED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-12-23 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-12-23 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2019-12-23 11:38:43 | NO SECOND UNIT PERMITTED IN REAR STRUCTURE. |
|
|