Plan Review Details - Permit 19120213
Plan Review Stops For Permit 19120213
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-19 Cont ID  
Sent By cthroop Date 2020-08-19 Time 12:27 Rev Time 0.00
Received By cthroop Date 2020-08-19 Time 08:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By cthroop Date 2020-01-03 Time 13:18 Rev Time 0.00
Received By cthroop Date 2019-12-31 Time 15:49 Sent To  
Notes
2020-01-03 13:36:51PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SEE PLAN PAGE A.01 CHANGE LEVEL OF ALTERATION FROM
 LEVEL 2 TO LEVEL 3 PER FBC R EXISTING SECTION 505.
 505.1 SCOPE. LEVEL 3 ALTERATIONS APPLY WHERE THE WORK
 AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA.
  
 2. DEMENSIONS OF STRUCTURE ON SURVEY AND ARCH. SITE
 PLAN DON'T MATCH.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. SEE PLAN PAGE A.02 DESCRIBE WHICH WINDOW WILL BE
 INSTALLED IN WINDOWS W1 AND W2. REFERENCE SPECIFIC NOA
 FOR EACH WIND TYPE.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. PROVIDE FINISHED FLOOR ELEVATION.
 R403.1.7.3 FOUNDATION ELEVATION.
  
 5. LANDINGS ARE REQUIRED AT EXTERIOR DOORS.
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
 R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS.
 R311.3.2 FLOOR ELEVATIONS FOR OTHER EXTERIOR DOORS.
  
 6. SEE PLAN PAGES A.02 AND A.05 WINDOW MARK ON WINDOW
 AND DOOR WIND PRESSURE SCHEDULE DOES NOT MATCH WINDOW
 NUMBER ON WINDOW SCHEDULE.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 7. PROVIDE ICC ES REPORT FOR ICYNENE SPRAY INSULATION.
 DESIGNER TO SELECT PRODUCT TO BE USED. PROVIDE
 INSTALLATION INSTRUCTIONS AT TIME OF INSPECTION.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-08-19 Cont ID  
Sent By cthroop Date 2020-08-19 Time 12:27 Rev Time 0.00
Received By cthroop Date 2020-08-19 Time 08:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-27 Cont ID  
Sent By jpearson Date 2019-12-27 Time 11:24 Rev Time 0.00
Received By jpearson Date 2019-12-27 Time 11:24 Sent To  
Notes
2019-12-27 11:23:50CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ONLY ONE SERVICE PER ADDRESS IS PERMITTED. PROVIDE
 CORRECTION. WPB FBC 107.2.1; NEC 230.2; FBC RE E3601.2
 2. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A
 BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE
 FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC
 225.30
 3. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A
 BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH
 CIRCUIT. NEC 250.32; FBC RE3607.3
 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31,
 225.32
 5. PLAN SHOWS ONE SMALL APPLIANCE CIRCUIT FOR KITCHEN
 RECEPTACLE OUTLETS. A MINIMUM OF TWO 20 AMPERE BRANCH
 CIRCUIT SHALL BE PROVIDED TO SUPPLY KITCHEN COUNTERTOP
 RECEPTACLE OUTLET(S). PROVIDE CORRECTION. NEC
 210.11(C)(1) , FBC RE E3703.2
 6. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 8. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
 9. PROVIDE ACCURATE LOAD CALCULATION FOR EXISTING
 SERVICE, INCLUDE EXISTING AND NEW LOADS TO CONFIRM
 CAPACITY OF SERVICE IS ADEQUATE. NEC 215.2, 220,
 408.30; FBC RE E3602.2
 10. PROVIDE LOCATION OF ELECTRICAL PANEL ON PLAN TO
 CONFIRM CODE COMPLIANCE. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-08-13 Cont ID  
Sent By lcrespo Date 2020-08-13 Time 12:54 Rev Time 0.00
Received By lcrespo Date 2020-08-13 Time 12:46 Sent To  
Notes
2020-08-13 12:54:13GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  
 NOTE: THE CITY OF WEST PALM BEACH HAS NO RECORD OF
 EXISTING GAS. A FULL EVALUATION OF ALL GAS EQUIPMENT
 WILL BE DONE AT FIELD, IF NOT TO CODE, IT MAY NEED TO
 BE BOUT UP TO CODE COMPLIANCE.

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-12-11 Cont ID  
Sent By fmittner Date 2020-12-11 Time 16:26 Rev Time 0.00
Received By fmittner Date 2020-12-11 Time 16:26 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2020-08-27 Cont ID  
Sent By fmittner Date 2020-08-27 Time 14:44 Rev Time 0.00
Received By fmittner Date 2020-08-27 Time 14:44 Sent To  
Notes
2020-08-27 14:44:49COMMENTS FROM 1ST REVIEW NOT ADDRESSED

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-12-23 Cont ID  
Sent By fmittner Date 2019-12-23 Time 11:34 Rev Time 0.00
Received By fmittner Date 2019-12-23 Time 11:34 Sent To  
Notes
2019-12-23 11:36:03PROPERTY IN HSITORIC DISTRICT, REQUIRES HPB APPROVAL OF
 COA FOR OPENING MODIFICATIONS AND HARDI BOARD.
  
 QUESTIONS, CONTACT: FRIEDERIKE MITTNER, CITY HSITORIC
 PRESERVATION PLANNER AT 822-1457

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-02-01 Cont ID  
Sent By lmarchan Date 2021-02-01 Time 14:20 Rev Time 0.00
Received By lmarchan Date 2021-01-29 Time 11:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-12-21 Cont ID  
Sent By shill Date 2020-12-21 Time 18:44 Rev Time 0.00
Received By shill Date 2020-12-07 Time 08:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-05 Cont ID  
Sent By cpuell Date 2020-09-05 Time 10:09 Rev Time 0.00
Received By cpuell Date 2020-08-08 Time 07:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-03 Cont ID  
Sent By cthroop Date 2020-01-03 Time 14:18 Rev Time 0.00
Received By cthroop Date 2019-12-05 Time 15:39 Sent To  
Notes
2019-12-06 15:39:14R06

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-02-01 Cont ID  
Sent By lmarchan Date 2021-02-01 Time 14:19 Rev Time 0.00
Received By lmarchan Date 2021-01-29 Time 11:44 Sent To  
Notes
2021-02-01 14:20:05NO FEES DUE PER IMPACT OFFICE. SEE UPLOADED EMAIL. LEM
2021-01-29 11:44:55010/29/21 EMAILED IMACT FEE OFFICE, QUESTIONNAIRE
 UPLOADED I N PD. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By cthroop Date 2020-01-03 Time 13:36 Rev Time 0.00
Received By cthroop Date 2020-01-03 Time 10:42 Sent To  
Notes
2020-01-03 13:38:01PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-02-01 Cont ID  
Sent By medwards Date 2021-02-01 Time 08:51 Rev Time 0.00
Received By medwards Date 2021-02-01 Time 08:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-08-10 Cont ID  
Sent By hmoser Date 2020-08-10 Time 08:15 Rev Time 0.00
Received By hmoser Date 2020-08-10 Time 07:37 Sent To  
Notes
2020-08-10 08:15:06PLAN DENIED
 1) PROVIDE EQUIPMENT SCHEDULE ON PLANS
 SECTION 107 FBC 2017
 2) PROVIDE CFM ON ALL SUPPLY DUCTS. SECTION
 107 FBC 2017
 3) HEATING AND COOLING LOADS REQUIRED.SECTION
 312 FBC (M) 2017
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By cthroop Date 2020-01-03 Time 13:38 Rev Time 0.00
Received By cthroop Date 2019-12-31 Time 15:49 Sent To  
Notes
2020-01-03 14:18:19PLAN REVIEW - MECHANICAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SERVICE DISCONNECT FOR CU ON PLAN PAGE E.01 SHALL BE
 220 VOLT.
 PANEL SCHEDULE:
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
  
 2. INDICATE THE SIZE OF THE RETURN DUCTS FROM THE RAG'S
 TO THE AIR HANDLER- SHOW DUCTS ON PLAN.
 SECTION M1602.2 FBC RES.
  
 3. PROVIDE ENGINEERING FOR INSTALLATION OF THE
 CONDENSER PAD AND MOUNTING OF THE CONDENSER- SECTIONS
 M1305.1.4.1 AND M1401.4 FBC RES.
  
 4. PROVIDE LOCKING ACCESS PORT CAPS.
 M1411.8 LOCKING ACCESS PORT CAPS.
  
 5. PROVIDE ENERGY SUBMITTAL
 R405.2 EC.
  
 6. PROVIDE MANUAL J WORSHEETS WITH AC SYSTEM SIZING
 CALCULATIONS.
 SECTION R403.7.1 FBC EC.
  
 7. PROVIDE EQUIPMENT SCHEDULE ON PLAN.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 8. EXHAUST VENTILATION AT A RATE OF 100 CFMS
 INTERMITTENT OR 25 CFMS CONTINUOUS SHALL BE PROVIDED
 FOR THE KITCHEN.
 TABLE M1507.4 FBC RES. PLEASE SEE SECTION M1503.1 FOR
 RANGE HOOD REQUIREMENTS, AND M1503.4 FOR MAKEUP AIR.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-08-13 Cont ID  
Sent By lcrespo Date 2020-08-13 Time 12:25 Rev Time 0.00
Received By lcrespo Date 2020-08-13 Time 12:25 Sent To  
Notes
2020-08-13 12:26:5008/13/20 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL,
 CONTRACTORS OR THEIR REPRESENTATIVES FROM THE
 RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-12-09 Cont ID  
Sent By lcrespo Date 2019-12-09 Time 15:20 Rev Time 0.00
Received By lcrespo Date 2019-12-09 Time 07:19 Sent To  
Notes
2019-12-09 15:21:0112/09/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM
 [email protected]
 561-701-6437
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2020-08-19 Cont ID  
Sent By cthroop Date 2020-08-19 Time 12:27 Rev Time 0.00
Received By cthroop Date 2020-08-19 Time 11:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-08-08 Cont ID  
Sent By pvalenti Date 2020-08-08 Time 06:56 Rev Time 0.00
Received By pvalenti Date 2020-08-08 Time 06:56 Sent To  
Notes
2020-08-08 06:57:44PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 SIGNATURE REVIEW APPROVED BY DIGITAL AND ORIGINAL PAPER
 PLANS.

Review Stop Z ZONING
Rev No 3 Status P Date 2020-12-11 Cont ID  
Sent By fmittner Date 2020-12-11 Time 16:26 Rev Time 0.00
Received By fmittner Date 2020-12-11 Time 16:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2020-08-27 Cont ID  
Sent By fmittner Date 2020-08-27 Time 14:44 Rev Time 0.00
Received By fmittner Date 2020-08-27 Time 14:44 Sent To  
Notes
2020-08-27 14:45:16COMMENTS FORM 1ST REVIEW NOT ADDRESSED

Review Stop Z ZONING
Rev No 1 Status F Date 2019-12-23 Cont ID  
Sent By fmittner Date 2019-12-23 Time 11:38 Rev Time 0.00
Received By fmittner Date 2019-12-23 Time 11:38 Sent To  
Notes
2019-12-23 11:38:43NO SECOND UNIT PERMITTED IN REAR STRUCTURE.