Plan Review Details - Permit 19120149
Plan Review Stops For Permit 19120149
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-04-13 Cont ID  
Sent By cthroop Date 2020-04-13 Time 14:42 Rev Time 0.00
Received By cthroop Date 2020-04-13 Time 14:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-03-04 Cont ID  
Sent By cthroop Date 2020-03-04 Time 15:06 Rev Time 0.00
Received By cthroop Date 2020-03-03 Time 16:49 Sent To  
Notes
2020-03-04 15:35:05PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES.
 ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1) CORRECTED
  
 2) 107.5.3 FBC[AMENDED] ADD CODE EDITION TO STATE
 CURRENT BUILDING CODE THAT APPLIES TO NEW WORK. (2017
 FLORIDA BUILDING CODE 6TH EDITION) (PLACE GOVERNING
 CODES ON FLOOR PLAN PAGE)
  
 3) CORRECTED
  
 4) THE DRAWINGS PROVIDED LACK SOME DETAIL AS TO THE
 BUILDING WILL MEET FLORIDA BUILDING CODES. PLEASE SEE
 BELOW FOR SOME ADDITIONAL INFORMATION THAT WILL HELP
 CLARIFY THE PROPOSED CONSTRUCTION.
 A. ADD DIMENSIONS TO THE PLANS THAT WILL AID IN
 BUILDING AND DETERMINING SQ. FOOTAGE. (NOT ADDRESSED)
 B. PROVIDE WINDOW AND DOOR SCHEDULES TO SHOW WINDOW
 LOCATIONS AND SIZES. SCHEDULE CAN CORESPOND WITH MARKS
 ON PLAN VIEW. (NOT ADDRESSED) (YOU MAY PLACE ROUGH
 OPENINGS AND DESIGN PRESSURES NEXT TO EACH OPENING ON
 PLAN)
 C. CORRECTED
 D. PLANS SAY STRAP AT VARIOUS POINTS IN THE ASSEMBLY.
 PLEASE STATE THE TYPE OF STRAP THAT WILL BE USED AT
 THESE LOCATIONS. (CANNOT READ CONNECTOR "A" ON
 SCHEDULE)
 E. CORRECTED
  
 5) ASCE 7-10 26.7.1 PLEASE ADD PROJECT DATA TO PLANS.
 (NOT CORRECTED) (PLACE THE FOLLOWING INFORMATION ON
 FLOOR PLAN PAGE)
  
 BUILDING TYPE - ACCESSORY
 OCCUPANCY = R3
 TYPE OF WALL CONSTRUCTION = WOOD FRAMED
 RISK CATEGORY = I
 EXPOSURE CATEGORY = B
 BUILDING CLASSIFICATION = ENCLOSED
 MEAN BLDG. HGT. = 0?-0? THIS WILL BE THE HEIGHT
 MEASURED FROM THE GROUND TO IN BETWEEN EAVE AND ROOF
 PEAK. (NOT CORRECTED)
 WIND SPEED V ULT = 155
 WIND SPEED V ASD = 112
 UNCONDITIONED SPACE = 672 SQ. FT.
  
 6) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 WINDOWS AND DOORS. (DESIGNER TO SELECT MODEL TO BE
 INSTALLED WITH INSTALLATION INSTRUCTIONS) (FLOOR PLAN
 INDICATES DOUBLE HUNG WINDOWS - PROVIDE PRODUCT
 APPROVALS FOR DOUBLE HUNG WINDOWS. DESIGNER SHALL
 SELECT MODEL AND PROVIDE INSTALLATION INSTRUCTIONS)
 301.2.1 FBC[R] PROVIDE DESIGN PRESSURES NEEDED FOR
 WINDOWS, DOORS, GARAGE DOOR, CLADDING AND COMPONENTS.
 (NOT CORRECTED)
 NOTE: R301.2.1.2 STORAGE SHEDS THAT ARE NOT DESIGNED
 FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720
 SQUARE FEET (67 M2) OR LESS ARE NOT REQUIRED TO COMPLY
 WITH THE MANDATORY WIND-BORNE DEBRIS IMPACT STANDARD OF
 THIS CODE.
 * THIS MEANS THEY DO NOT HAVE TO HAVE HURRICANE
 PROTECTION, BUT THEY STILL NEED TO MEET PRESSURES. THE
 PRODUCT APPROVALS WILL STATE THE PRESSURES THEY ARE
 DESIGNED FOR.
  
 7) CORRECTED
  
 8) R318 FBC[R]ADD NOTE FOR TERMITE TREATMENT TO BE
 COMPLETED AS REQUIRED IN R318. (NOT CORRECTED)
  
 NEW COMMENTS
  
 9) CITY OF WPB CHPT. 1 ? VALUE
 109.3 BUILDING PERMIT VALUATIONS.
  
 THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF
 WORK.
  
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By dbattles Date 2020-01-03 Time 15:47 Rev Time 0.00
Received By dbattles Date 2020-01-03 Time 11:12 Sent To  
Notes
2020-01-03 15:49:24BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19120149
 REVIEWED: JANUARY 3, 2020
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) 107.5.3 FBC[AMENDED] 107.2.1FBC[AMENDED] ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
 - PLEASE ADD SIGNATURE OF RESPONSIBLE PARTY TO ALL
 PLANS. ALSO, PROVIDE A SECOND SET OF PLANS.
  
 2) 107.5.3 FBC[AMENDED] ADD CODE EDITION TO STATE
 CURRENT BUILDING CODE THAT APPLIES TO NEW WORK. (2017
 FLORIDA BUILDING CODE 6TH EDITION)
  
 3) WILL THIS STRUCTURE BE COOLED? IS SO PLEASE PROVIDE
 INSULATION THAT WILL BE USED IN CEILING AND WALLS AND
 PROVIDE MECHANICAL PLANS.
 IF COOLING OR VENTILATION PROVIDED PROVIDE PLANS AND A
 MECHANICAL REVIEW WILL BE ADDED.
  
 4) THE DRAWINGS PROVIDED LACK SOME DETAIL AS TO THE
 BUILDING WILL MEET FLORIDA BUILDING CODES. PLEASE SEE
 BELOW FOR SOME ADDITIONAL INFORMATION THAT WILL HELP
 CLARIFY THE PROPOSED CONSTRUCTION.
 A. ADD DIMENSIONS TO THE PLANS THAT WILL AID IN
 BUILDING AND DETERMINING SQ. FOOTAGE.
 B. PROVIDE WINDOW AND DOOR SCHEDULES TO SHOW WINDOW
 LOCATIONS AND SIZES. SCHEDULE CAN CORESPOND WITH MARKS
 ON PLAN VIEW.
 C. R802 FBC[R]SHOW A ROOF PLAN THAT RELATES TO THE
 DETAIL PROVIDED. WILL THE ROOF BE ENGINEERED TRUSSES,
 OR ARE THEY SITE BUILT. IF SITE BUILT PLEASE SHOW HOW
 THEY WILL BE CONNECTED AT AL POINTS AND HOW THEY RESIST
 LATERAL FORCES (BRACING AND GABLE END BRACING)
 D. PLANS SAY STRAP AT VARIOUS POINTS IN THE ASSEMBLY.
 PLEASE STATE THE TYPE OF STRAP THAT WILL BE USED AT
 THESE LOCATIONS.
 E. ARE THERE VENTS AT THE OVERHANGS? PROVIDE DETIAL OF
 OVERHANG AND HOW/WHERE VENTS ARE INSTALLED.
  
 5) ASCE 7-10 26.7.1 PLEASE ADD PROJECT DATA TO PLANS.
 STATE ON PLAN THAT THIS WILL BE ACCESSORY STRUCTURE.
 OCCUPANCY = R3
 TYPE OF WALL CONSTRUCTION = ARE THE WALLS MASONRY,
 CONCRETE OR WOOD FRAMED?
 RISK CATEGORY = I
 EXPOSURE CATEGORY = B
 BUILDING CLASSIFICATION = ENCLOSED
 MEAN BLDG. HGT. = 0?-0? THIS WILL BE THE HEIGHT
 MEASURED FROM THE GROUND TO IN BETWEEN EAVE AND ROOF
 PEAK.
 WIND SPEED V ULT = 155
 WIND SPEED V ASD = 112
 ALSO, STATE SQ. FOOTAGE CONDITIONED AND NON
 CONDITIONED.
  
 6) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 WINDOWS AND DOORS.
 301.2.1 FBC[R] PROVIDE DESIGN PRESSURES NEEDED FOR
 WINDOWS, DOORS, GARAGE DOOR, CLADDING AND COMPONENTS.
 NOTE: R301.2.1.2 STORAGE SHEDS THAT ARE NOT DESIGNED
 FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720
 SQUARE FEET (67 M2) OR LESS ARE NOT REQUIRED TO COMPLY
 WITH THE MANDATORY WIND-BORNE DEBRIS IMPACT STANDARD OF
 THIS CODE.
 * THIS MEANS THEY DO NOT HAVE TO HAVE HURRICANE
 PROTECTION, BUT THEY STILL NEED TO MEET PRESSURES. THE
 PRODUCT APPROVALS WILL STATE THE PRESSURES THEY ARE
 DESIGNED FOR.
  
 7) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVAL FOR
 ROOF SHINGLES.
  
 8) R308 FBC[R]ADD NOTE FOR TERMITE TREATMENT TO BE
 COMPLETED AS REQUIRED IN R308.
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2020-02-20 Cont ID  
Sent By jleahy Date 2020-02-20 Time 15:20 Rev Time 0.00
Received By jleahy Date 2020-02-20 Time 15:20 Sent To  
Notes
2020-02-20 15:20:43ELECTRICAL NOT REQUIRE NONE SHOWN JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-24 Cont ID  
Sent By jleahy Date 2019-12-24 Time 11:48 Rev Time 0.00
Received By jleahy Date 2019-12-24 Time 11:44 Sent To  
Notes
2019-12-24 11:48:48FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 1) OUTLETS REQUIRED
  
 E3901.9 BASEMENTS, GARAGES AND ACCESSORY BUILDINGS.
 NOT LESS THAN ONE RECEPTACLE OUTLET, IN ADDITION TO ANY
 PROVIDED FOR SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN
 EACH SEPARATE UNFINISHED PORTION OF A BASEMENT, IN EACH
 ATTACHED GARAGE, AND IN EACH DETACHED GARAGE OR
 ACCESSORY BUILDING THAT IS PROVIDED WITH ELECTRICAL
 POWER. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S)
 IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE
 GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE
 INSTALLED FOR EACH MOTOR VEHICLE SPACE. [210.52(G)(1),
 (2), AND (3)]
  
 E3902.2 GARAGE AND ACCESSORY BUILDING RECEPTACLES.
 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE RECEPTACLES
 INSTALLED IN GARAGES AND GRADE-LEVEL PORTIONS OF
 UNFINISHED ACCESSORY BUILDINGS USED FOR STORAGE OR WORK
 AREAS SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER
 PROTECTION FOR PERSONNEL. [210.8(A)(2)]
  
 2) LIGHTING REQUIRED.
  
 E3903.3 ADDITIONAL LOCATIONS.
 AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET
 SHALL BE INSTALLED IN HALLWAYS, STAIRWAYS, ATTACHED
 GARAGES, AND DETACHED GARAGES WITH ELECTRIC POWER. AT
 LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING OUTLET SHALL
 BE INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR
 SIDE OF EACH OUTDOOR EGRESS DOOR HAVING GRADE LEVEL
 ACCESS, INCLUDING OUTDOOR EGRESS DOORS FOR ATTACHED
 GARAGES AND DETACHED GARAGES WITH ELECTRIC POWER. A
 VEHICLE DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS AN
 OUTDOOR EGRESS DOOR. WHERE ONE OR MORE LIGHTING OUTLETS
 ARE INSTALLED FOR INTERIOR STAIRWAYS, THERE SHALL BE A
 WALL SWITCH AT EACH FLOOR LEVEL AND LANDING LEVEL THAT
 INCLUDES AN ENTRYWAY TO CONTROL THE LIGHTING OUTLETS
 WHERE THE STAIRWAY BETWEEN FLOOR LEVELS HAS SIX OR MORE
 RISERS. [210.70(A)(2)]
  
 3) LOAD CALCULATION REQUIRED FOR THE SERVICE.
  
 E3704.1CONDUCTOR SIZE.
 FEEDER CONDUCTORS THAT DO NOT SERVE 100 PERCENT OF THE
 DWELLING UNIT LOAD AND BRANCH-CIRCUIT CONDUCTORS SHALL
 BE OF A SIZE SUFFICIENT TO CARRY THE LOAD AS DETERMINED
 BY THIS CHAPTER. FEEDER CONDUCTORS SHALL NOT BE
 REQUIRED TO BE LARGER THAN THE SERVICE-ENTRANCE
 CONDUCTORS THAT SUPPLY THE DWELLING UNIT. THE LOAD FOR
 FEEDER CONDUCTORS THAT SERVE AS THE MAIN POWER FEEDER
 TO A DWELLING UNIT SHALL BE DETERMINED AS SPECIFIED IN
 CHAPTER 36 FOR SERVICES. [310.15(B)(7)(2) AND (3)]
  
 E3602.2SERVICE LOAD.
 THE MINIMUM LOAD FOR UNGROUNDED SERVICE CONDUCTORS AND
 SERVICE DEVICES THAT SERVE 100 PERCENT OF THE DWELLING
 UNIT LOAD SHALL BE COMPUTED IN ACCORDANCE WITH TABLE
 E3602.2. UNGROUNDED SERVICE CONDUCTORS AND SERVICE
 DEVICES THAT SERVE LESS THAN 100 PERCENT OF THE
 DWELLING UNIT LOAD SHALL BE COMPUTED AS REQUIRED FOR
 FEEDERS IN ACCORDANCE WITH CHAPTER 37. [220.82(A)]
  
 4) NO ELECTRIC SHOWN
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER
 561-805-6713
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-04 Cont ID  
Sent By cthroop Date 2020-03-04 Time 15:35 Rev Time 0.00
Received By cthroop Date 2020-02-18 Time 13:35 Sent To I
Notes
2020-02-26 17:30:03TO JG DESK
  
2020-02-19 13:35:54RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-01-03 Cont ID  
Sent By dbattles Date 2020-01-03 Time 16:06 Rev Time 0.00
Received By dbattles Date 2019-12-04 Time 14:31 Sent To  
Notes
2019-12-05 14:31:36R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-04-11 Cont ID  
Sent By shill Date 2020-04-11 Time 09:17 Rev Time 0.00
Received By shill Date 2020-04-11 Time 09:17 Sent To  
Notes
2020-04-11 09:18:01STAMPED PLAN PROVIDED ($0 DUE)
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By dbattles Date 2020-01-03 Time 16:02 Rev Time 0.00
Received By dbattles Date 2020-01-03 Time 11:12 Sent To  
Notes
2020-01-03 16:06:31109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-01-03 Cont ID  
Sent By dbattles Date 2020-01-03 Time 15:57 Rev Time 0.00
Received By dbattles Date 2020-01-03 Time 15:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2019-12-11 Cont ID  
Sent By lcrespo Date 2019-12-11 Time 06:58 Rev Time 0.00
Received By lcrespo Date 2019-12-11 Time 06:58 Sent To  
Notes
2019-12-11 06:59:45NO PLUMBING IN BUILDING

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-03-04 Cont ID  
Sent By cthroop Date 2020-03-04 Time 15:06 Rev Time 0.00
Received By cthroop Date 2020-03-03 Time 16:49 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-01-03 Cont ID  
Sent By dbattles Date 2020-01-03 Time 15:49 Rev Time 0.00
Received By dbattles Date 2020-01-03 Time 15:49 Sent To  
Notes
2020-01-03 15:57:12SEE BUILDING COMMENT #7

Review Stop Z ZONING
Rev No 1 Status P Date 2019-12-19 Cont ID  
Sent By rfalcone Date 2019-12-19 Time 09:44 Rev Time 0.00
Received By rfalcone Date 2019-12-19 Time 09:44 Sent To I
Notes
***NONE***