Plan Review Details - Permit 19120063
Plan Review Stops For Permit 19120063
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-02-05 Cont ID  
Sent By jwitmer Date 2020-02-05 Time 11:46 Rev Time 0.00
Received By rmcphers Date 2020-02-05 Time 11:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-12-17 Cont ID  
Sent By jwitmer Date 2019-12-17 Time 13:33 Rev Time 0.00
Received By jwitmer Date 2019-12-17 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-21 Cont ID  
Sent By jpearson Date 2020-01-21 Time 09:55 Rev Time 0.00
Received By jpearson Date 2020-01-21 Time 09:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-25 Cont ID  
Sent By jleahy Date 2019-12-25 Time 13:51 Rev Time 0.00
Received By jpearson Date 2019-12-25 Time 13:51 Sent To  
Notes
2019-12-25 13:37:02 
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A
 BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE
 FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC
 225.30
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-01-30 Cont ID  
Sent By pleduc Date 2020-01-30 Time   Rev Time 0.00
Received By pleduc Date 2020-01-30 Time 12:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-12-13 Cont ID  
Sent By pleduc Date 2019-12-13 Time   Rev Time 0.00
Received By pleduc Date 2019-12-12 Time 16:40 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2020-02-17 Cont ID  
Sent By thunt Date 2020-02-17 Time 16:47 Rev Time 0.00
Received By shill Date 2020-02-16 Time 07:28 Sent To  
Notes
2020-02-17 16:57:31REVIEWED REMOTELY BY TIM HUNT

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-12-30 Cont ID  
Sent By shill Date 2019-12-30 Time 07:38 Rev Time 0.00
Received By shill Date 2019-12-30 Time 07:38 Sent To  
Notes
2019-12-30 07:38:55GAS 1ST REVIEW**DENIED**19120063
 ****PLEASE SUBMIT A NARRATIVE OF THE CHANGES FOR THIS
 REVISION****
 1-GAS INFORMATION IS LISTED DIFFERENTLY ON SHT. CS1
 THEN ON P1.1 AND P2. PIPE SIZE, DISTANCE AND GAS
 PRESSURE DOES NOT MATCH. PLEASE CORRECT. FBC 107.3.5
 2- SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE
 CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR
 EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1.
  
 3- SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1
  
 4-. SUBMIT TWO COPIES OF A SIDE VIEW SHOWING THE
 MOUNTING OF THE TANKLESS WATER HEATER AND THE LOCATION
 AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN
 RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER
 HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. WPB AMEND. TO FBC SEC.
 107.2.1
  
 5- SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL
 GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1)
 THRU 402.4 (37)
 6- IF 2 POUND GAS SYSTEM SUBMIT MANUFACTURER?S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION. 2017 FGC SEC.410.1
 7) IF 2 POUND SYSTEM SHOW THE DISTANCE FROM THE 2 PSI
 REGULATOR TO THE APPLIANCE. COMPLY WITH 2017 FBC-FUEL
 GAS SEC. 402.4.1
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 [email protected]
 561-248-2703
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-17 Cont ID  
Sent By shill Date 2020-02-17 Time 16:56 Rev Time 0.00
Received By shill Date 2020-01-28 Time 09:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-12-30 Time   Rev Time 0.00
Received By lmarchan Date 2019-12-05 Time 08:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-02-12 Cont ID  
Sent By ccole Date 2020-02-12 Time 15:38 Rev Time 0.00
Received By ccole Date 2020-02-12 Time 15:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-12-30 Cont ID  
Sent By cmontell Date 2019-12-30 Time 09:28 Rev Time 0.00
Received By ccole Date 2019-12-30 Time 09:28 Sent To  
Notes
2019-12-30 09:42:081ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19120063
 12/20/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ACCORDING TO THE INSTALLATION MANUAL FOR THE BAKER'S
 PRIDE ELECTRIC OVEN MODEL BCO E2, A TYPE II HEAT HOOD
 IS THE STANDARD VENTILATION METHOD. THE SPECS DO NOT
 CALL OUT INSTALLATION OF A DOUBLE WALL B VENT WHICH IS
 TYPICALLY USED FOR GAS-VENTED APPLIANCES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-02-17 Cont ID  
Sent By thunt Date 2020-02-17 Time 16:47 Rev Time 0.00
Received By shill Date 2020-02-16 Time 07:28 Sent To  
Notes
2020-02-17 16:57:50REVIEWED REMOTELY BY TIM HUNT

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-30 Cont ID  
Sent By gjohnson Date 2019-12-30 Time 07:39 Rev Time 0.00
Received By shill Date 2019-12-27 Time 15:23 Sent To  
Notes
2019-12-30 07:39:46PLUMBING 1ST REVIEW**DENIED**19120063
 1-PROVIDE A NARRATIVE OF WHAT THIS REVISION ENTAILS.
 FBC 107.2.1
 2-GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION
 ONLY. PLEASE REMOVE THE VERTICAL GRAB BAR IN THE TOILET
 ROOMS. 609.4POSITION OF GRAB BARS. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION.
 3- WITH THE TOILET PAPER DISPENSER BEING OWNER SUPPLIED
 PLEASE ADD NOTE THAT MOUNTING TO BE 7?-9? TO THE CENTER
 OF THE WHERE IT DISPENSER PAPERS 1ST ROLL. FBC-ACC
 604.7
 4-SHOW REAR GRAB BAR MOUNTING AS 12? FROM THE CENTER
 LINE OF THE TOILET AND NOT JUST 6? OFF SIDE WALL.
 FBC-ACC 604.5.2
 5- PROVIDE A SANITARY AND WATER RISER ISOMETRIC
 DRAWING. YOU ARE ONLY SHOWING A FLAT DRAWING. FBC
 107.3.5
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH (CGA SOLUTIONS)
 [email protected]
 561-248-2703
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-02-17 Cont ID  
Sent By shill Date 2020-02-17 Time 16:56 Rev Time 0.00
Received By shill Date 2020-02-17 Time 16:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-12-30 Cont ID  
Sent By shill Date 2019-12-30 Time 07:46 Rev Time 0.00
Received By shill Date 2019-12-30 Time 07:46 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved