Plan Review Details - Permit 19111270
| Plan Review Stops For Permit 19111270 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-30 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-12-30 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-02 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-12-02 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2019-12-02 12:41:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.250.32-B-1 FEEDER TO PANEL | | | 2. 230.72 GROUP MAINS, FEEDER TO METER NOT DISCONECT | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-12-30 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-30 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-12-16 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2019-12-17 15:16:27 | RESUB ROUTED TO PPETTY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-12-02 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-11-25 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2019-11-26 13:33:57 | REVISION ROUTED TO PPETTY |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |