Plan Review Details - Permit 19111267
| Plan Review Stops For Permit 19111267 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-12-01 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-12-01 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-03-13 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-03-13 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-12-01 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-12-01 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2019-12-01 13:07:42 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1 PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. ON THE SURVEY (WHICH IS USED AS A FLOOR PLAN), | | | PLEASE INDICATE WHERE THE BEDROOMS ARE. | | | 2. ON THE SURVEY/FLOOR PLAN INDICATE LOCATIONS OF | | | SIDING REPLACEMENT. | | | | | | | | | NOTE: IF MULLIONS ARE TO BE USED PROVIDE PRODUCT | | | APPROVAL AND LOCATIONS ON FLOOR PLAN. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-03-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-03-12 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-03-12 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2020-03-12 10:28:08 | HOUSE ORIGINALLY HAD ASBESTOS, SMOOTH HARDI BOARD OK |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-11-26 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-11-26 |
Time |
16:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-03-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-03-13 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-03-06 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2020-03-12 15:15:32 | 3/12 ROUTED TO PVALENTI | | 2020-03-09 13:49:31 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-12-01 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-11-25 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2019-11-26 13:03:14 | ROUTED TO HISTORIC INBOX |
|
|
|