Plan Review Details - Permit 19111230
Plan Review Stops For Permit 19111230
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-01-25 Cont ID  
Sent By cthroop Date 2020-01-25 Time 07:16 Rev Time 0.00
Received By cthroop Date 2020-01-16 Time 07:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:34 Rev Time 0.00
Received By cthroop Date 2020-01-08 Time 10:30 Sent To  
Notes
2020-01-11 10:52:49PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. VALUE HAS BEEN ADJUSTED FROM $85,000 TO $180,405
 BASED ON THE ICC BUILDING VALUATION TABLES. 1488 SQ FT
 X $121.24/SQ FT = $180,405.
  
 CITY OF WPB CHPT. 1 VALUE 109.3 BUILDING PERMIT
 VALUATIONS.
  
 2. DESIGNER OF RECORD (DOR) STATES VALUE IS OVER
 ESTIMATED FOR THIS NEIBORHOOD. ADJUSTMENTS TO VALUE ARE
 OUT OF PLANS EXAMINERS PERVIEW.
  
 3. DOR MAY SUBMIT ADJUSTMENT REQUEST ON COMPANY
 LETTERHEAD TO MR. ROBERT BROWN, BUILDING OFFICIAL, CITY
 OF WEST PALM BEACH, FL 33401. LETTER MUST BE ORIGINAL
 SIGNED AND SEALED BY DOR.
  
 4. SUBMIT PRODUCT APPROVALS FOR PROPOSED WINDOWS, DOORS
 AND ROOFING SYSTEM COMPONENTS. INCLUDE PRODUCT APPROVAL
 COVER LETTER AND INSTALLATION INSTRUCTIONS FOR SPECIFIC
 MODEL/PRODUCTS SELECTED.
  
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 DEFERAL OF PRODUCT APPROVALS MAY BE SELECTED. SEE
 BELOW.
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 IF DEFERAL OPTION IS SELECTED, PROVIDE LIST OF PRODUCTS
 TO BE DEFERRED ON PLANS. I.E. WINDOWS, DOORS, ROOFING
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-30 Cont ID  
Sent By cthroop Date 2019-11-30 Time 08:20 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:01 Sent To  
Notes
2019-11-30 08:35:37PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. VALUE HAS BEEN ADJUSTED FRO 85000 TO 180405 BASED ON
 THE ICC BUILDING VALUATION TABLES.
  
 2. PROVIDE SURVEY AND DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
  
 PROVIDE SITE PLAN.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
  
 3. PROVIDE WINDOW AND DOOR SCHEDULE. INCLUDE ROUGH
 OPENINGS AND DESIGN PRESSURES.
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 4. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND
 EXTERIOR DOORS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
 5. DESIGNER SHALL STATE INSULATION R VALUES ON PLAN.
 CEILINGS R-30 AND WALLS R-3.0.
 R402.2 SPECIFIC INSULATION REQUIREMENTS (PRESCRIPTIVE).
 IN ADDITION TO THE REQUIREMENTS OF SECTION R402.1,
 INSULATION SHALL MEET THE SPECIFIC REQUIREMENTS OF
 SECTIONS R402.2.1 THROUGH R402.2.13.
  
 6. INSULATION ABOVE ATTIC SCUTTLE SHALL EQUAL
 SURRONDING R VALUE.
 R402.2.4 ACCESS HATCHES AND DOORS.
  
 7. ATTIC SCUTTLE SHALL HAVE WEATHER STRIPPING.
 R402.2.4 ACCESS HATCHES AND DOORS.
  
 8. LANSCAPE PLAN PAGE L INDICATES A THREE FOOT OVERHANG
 FOR ROOFING. NO STRUCTURAL DETAILS ARE PROVIDED. PLEASE
 CLARIFY.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 9. SHOW LOCATION OF ATTIC ACCESS ON PLANS. ACCESS SHALL
 COMPLY WITH M1305.1.3. SWITCHED LUMINARE AND SERVICE
 OUTLET ARE REQUIRED FOR MECH. EQUIPT. IN ATTICS.
 M1305.1.3.1 ELECTRICAL REQUIREMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG
 WITH THE CITY RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY,
 INSERT CORRECTED PAGES INTO
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS
 DETACHED.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:10 Rev Time 0.00
Received By cthroop Date 2020-01-08 Time 10:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-03 Cont ID  
Sent By cthroop Date 2019-12-03 Time 10:12 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:00 Sent To  
Notes
2019-12-03 10:39:02PLAN REVIEW - ELECTRICAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. AIC:
  
 PROVIDE ACTUAL TRANSFORMER SECONDARY FAULT CURRENT FROM
 UTILITY.
 E3404.2INTERRUPTING RATING.
 EQUIPMENT INTENDED TO INTERRUPT CURRENT AT FAULT LEVELS
 SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000
 AMPERES. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT
 LEVELS OTHER THAN FAULT LEVELS SHALL HAVE AN
 INTERRUPTING RATING AT NOMINAL CIRCUIT VOLTAGE OF NOT
 LESS THAN THE CURRENT THAT MUST BE INTERRUPTED. (110.9)
  
 2. PANEL SCHEDULE STATES PANELS A&B. PLEASE CLARIFY.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. CIRCUTS 15 AND 17 FOR SMALL APPLIANCE SHALL BE A
 MINIMUM OF 20 AMP PER E3703.2 & E3902.3.
 E3703.2 KITCHEN AND DINING AREA RECEPTACLES.
 A MINIMUM OF TWO 20-AMPERE-RATED BRANCH CIRCUITS SHALL
 BE PROVIDED TO SERVE ALL WALL AND FLOOR RECEPTACLE
 OUTLETS LOCATED IN THE KITCHEN, PANTRY, BREAKFAST AREA,
 DINING AREA OR SIMILAR AREA OF A DWELLING.
 E3901.3 SMALL APPLIANCE RECEPTACLES.
 IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR
 SIMILAR AREA OF A DWELLING UNIT, THE TWO OR MORE
 20-AMPERE SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
 SECTION E3703.2, SHALL SERVE ALL WALL AND FLOOR
 RECEPTACLE OUTLETS COVERED BY SECTIONS E3901.2 AND
 E3901.4 AND THOSE RECEPTACLE OUTLETS PROVIDED FOR
 REFRIGERATION APPLIANCES. [210.52(B)(1)].
  
 4. CIRCUT 23 FOR LAUNDRY SHALL BE A MINIMUM OF 20 AMPS
 PER E3703.3.
 E3703.3 LAUNDRY CIRCUIT.
 A MINIMUM OF ONE 20-AMPERE-RATED BRANCH CIRCUIT SHALL
 BE PROVIDED FOR RECEPTACLES LOCATED IN THE LAUNDRY AREA
 AND SHALL SERVE ONLY RECEPTACLE OUTLETS LOCATED IN THE
 LAUNDRY AREA. [210.11(C)(2)].
  
 5. CONDUCTOR SIZING FOR THE WATER HEATER (2/40AMP) AND
 STOVE (2/60AMP) IS UNDERSIZED PER TABLE E3705.1.
  
 6. ARC FAULT NOTE ON PAGE E-1 SHALL INCLUDE KITCHENS.
 AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL BRANCH
 CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND
 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS,
 DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING, POWER
 OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH AFCI
 AND GFCI PROTECTION. PROVIDE CORRECTION. NEC 210.8,
 210.12; FBC RE E3902.16; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
  
 7. PROVIDE SERVICE OUTLET AT CONDENSING UNIT PER
 E3901.12.
 E3901.12 HVAC OUTLET.
  
 8. EXTERIOR OUTLET REQUIRED AT FRONT OF STRUCTURE PER
 E3901.7.
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
 BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM
 INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE
 BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE
 LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE
 THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)]
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-01-26 Cont ID  
Sent By cpuell Date 2020-01-26 Time 07:56 Rev Time 0.00
Received By cpuell Date 2020-01-13 Time 11:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:54 Rev Time 0.00
Received By cthroop Date 2020-01-06 Time 07:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-09 Cont ID  
Sent By shill Date 2019-12-04 Time 17:39 Rev Time 0.00
Received By shill Date 2019-11-25 Time 11:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2020-01-27 Cont ID  
Sent By lmarchan Date 2020-01-27 Time 11:05 Rev Time 0.00
Received By lmarchan Date 2020-01-13 Time 11:54 Sent To  
Notes
2020-01-27 08:08:57RECEIPT 2020-0117-293 - $9401.07 - PAID
2020-01-13 11:55:071/13/20 SENT EMAIL TO IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:22 Rev Time 0.00
Received By cthroop Date 2020-01-11 Time 08:48 Sent To  
Notes
2020-01-11 10:23:15PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-11-30 Cont ID  
Sent By cthroop Date 2019-11-30 Time 08:13 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:00 Sent To  
Notes
2019-11-30 08:14:31PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:18 Rev Time 0.00
Received By cthroop Date 2020-01-08 Time 10:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-11-30 Cont ID  
Sent By cthroop Date 2019-11-30 Time 10:33 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:00 Sent To  
Notes
2019-11-30 10:46:26PLAN REVIEW - MECHANICAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SERVICE OUTLET AT CONDENSING UNIT PER
 E3901.12
 E3901.12 HVAC OUTLET.
  
 2. SHOW FLEX DUCT TO BATHROOM. SHOW SIZE AND CFM.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. RETURN AIR SHALL COMPLY WITH M1602.2.
 PROVIDE CFM'S AT EACH SUPPLY. BALANCED RETURN AIR SHALL
 COMPLY WITH 1602.3. 50 SQ. INCHES FOR EACH 100 CFM OF
 SUPPLY.
  
 4. SHOW LOCATION OF EXHAUST FANS ON PLANS.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 5. PROVIDE LOCATION OF DRYER EXHAUST ON PLANS. EXHAUST
 TERMINATION SHALL COMPLY WITH M1502.3.
  
 6. SHOW LOCATION OF ATTIC ACCESS ON PLANS. ACCESS SHALL
 COMPLY WITH M1305.1.3. SWITCHED LUMINARE AND SERVICE
 OUTLET ARE REQUIRED FOR MECH. EQUIPT. IN ATTICS.
 M1305.1.3.1 ELECTRICAL REQUIREMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG
 WITH THE CITY RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY,
 INSERT CORRECTED PAGES INTO
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS
 DETACHED.
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-12-03 Cont ID  
Sent By cthroop Date 2019-12-03 Time 14:44 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:01 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2020-01-25 Cont ID  
Sent By cthroop Date 2020-01-25 Time 07:09 Rev Time 0.00
Received By cthroop Date 2020-01-16 Time 07:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:28 Rev Time 0.00
Received By cthroop Date 2020-01-08 Time 10:30 Sent To  
Notes
2020-01-11 10:34:27PLAN REVIEW - ROOFING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
  
 1. ROOFING PERMIT REQUIRED. (ACKNOWLEDGED)
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS OF NEW ROOFING SYSTEM
 COMPONENETS. (NOT ADDRESSED) (YOU MAY SELECT TO DEFER
 PRODUCT APPROVALS - SEE BELOW)
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-11-30 Cont ID  
Sent By cthroop Date 2019-11-30 Time 08:17 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:01 Sent To  
Notes
2019-11-30 08:20:20PLAN REVIEW - ROOFING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS OF NEW ROOFING SUSTEM
 COMPONENETS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG
 WITH THE CITY RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY,
 INSERT CORRECTED PAGES INTO
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS
 DETACHED.
  
  
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-01-25 Cont ID  
Sent By cthroop Date 2020-01-25 Time 07:09 Rev Time 0.00
Received By cthroop Date 2020-01-16 Time 07:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-01-11 Cont ID  
Sent By cthroop Date 2020-01-11 Time 10:21 Rev Time 0.00
Received By cthroop Date 2020-01-08 Time 10:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-11-30 Cont ID  
Sent By cthroop Date 2019-11-30 Time 08:14 Rev Time 0.00
Received By cthroop Date 2019-11-27 Time 08:00 Sent To  
Notes
2019-11-30 08:17:07PLAN REVIEW - DIGITAL SIGNATURES AND SEALS
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 DIGITAL REVIEW
  
 1. DIGITAL SIGNATURES/SEALS ARE IN ACCORDANCE WITH FS
 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE NEXT
 REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-12-11 Cont ID  
Sent By rfalcone Date 2019-12-11 Time 09:37 Rev Time 0.00
Received By rfalcone Date 2019-12-11 Time 09:37 Sent To I
Notes
2019-12-11 09:38:2112/11/19
  
 SEPERATE LANDSCAPE PERMIT MUST BE SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 RACHEL FALCONE, ASSOCIATE PLANNER
 DEVELOPMENT SERVICES DEPARTMENT
 E-MAIL: [email protected]
 TEL: (561) 822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-12-04 Cont ID  
Sent By cdglass Date 2019-12-04 Time 09:14 Rev Time 0.00
Received By cdglass Date 2019-12-04 Time 09:14 Sent To  
Notes
2019-12-04 09:16:06ZBA APPROVAL REQUIRED FOR PASSING OF THIS PERMIT.
  
 CAROLINE GLASS
 [email protected]