| Plan Review Stops For Permit 19110703 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-03-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-03-09 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-03-09 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2020-03-09 16:59:44 | SINCE ACCESSORY UNIT NOT ALLOWED, NO ADDRESS TO BE | | | GIVEMN AT THIS TIME. SHOULD THIS CHANGE PLEASE CONTACT | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2020-05-06 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2020-05-06 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-03-26 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-03-26 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2020-03-26 11:49:41 | ALTERATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE LABEL EACH ROOM SHOWN ON THE FLOOR PLAN. FBC | | | WPB AMENDMENTS 107 | | | 2) PLEASE SHOW THE WALL AND CEILING INSULATION TYPE AND | | | "R" VALUE TO COMPLY WITH FBC ENERGY R402 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-04 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-04 13:52:19 | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE LABEL EACH ROOM SHOWN ON THE FLOOR PLAN. FBC | | | WPB AMENDMENTS 107 | | | 2) PLEASE SHOW THE REQUIRED EMERGENCY EGRESS FROM | | | SLEEPING ROOMS. PER FBC R310 | | | 3) PLEASE PROVIDE STRUCTURAL DETAILS FOR THE CLOSING UP | | | OF THE OVERHEAD GARAGE DOOR. FBC WPB AMENDMENTS 107 | | | 4) PLEASE PROVIDE WIND LOAD CALCULATIONS OR SIGNED AND | | | SEALED DETAILS FROM AN ARCHITECT OR ENGINEER. FBC | | | R301.1.3 | | | 5) PLEASE SHOW ON THE DRAWINGS THE WIND DESIGN | | | PARAMETERS USED (CODE VERSION, WIND SPEED, ETC.) PER | | | FBC R301.2.1.1 - FBC 1609.1.1 | | | 6) PLEASE SHOW NEW WINDOW SIZES. FBC WPB AMENDMENTS107 | | | 7) PLEASE SHOW THE WALL AND CEILING INSULATION TYPE AND | | | "R" VALUE TO COMPLY WITH FBC ENERGY R402 | | | 8) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND | | | INSTALLATION INSTRUCTIONS) PRODUCT APPROVALS FOR THE | | | NEW EXTERIOR WINDOWS. FBC R301.2.1.2 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-16 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-16 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2019-12-16 11:21:28 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 19110703 | | | REVIEWED: DECEMBER 16, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1) 107.5.3 FBC[AMENDED] 107.2.1FBC[AMENDED] ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | -PLEASE ADD NAME OF PERSON ON EACH PAGE PROVIDED. I SEE | | | SIGNATURE ON ONE SHEET ONLY, BUT NAME AND SIGNATURE | | | SHOULD BE ON ALL PAGES. | | | | | | 2) PROVIDE A DESCRIPTION AND NOTES OF WORK BEING | | | PERFORMED ON THE PLAN. IT IS HARD TO TELL THE EXTENT OF | | | WORK WITH THE DRAWING PROVIDED. FOR EXAMPLE, ARE THE | | | EXTERIOR WALLS BEING DRYWALLED, INSULATION | | | CEILING/WALLS AND WHAT ARE NEW PARTITIONS MADE FROM? | | | | | | 3) ADD SOME PROJECT DATA TO THE PLANS: | | | SQ. FOOTAGE OF AREA OF WORK | | | DIMENSIONS OF NEW ELEMENTS | | | WIND DESIGN CRITERIA | | | OCCUPANCY (R3) | | | | | | 4) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: | | | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN | | | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF | | | SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED | | | PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY | | | SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. | | | -HOW ARE ENERGY CODE REQUIRMENTS BEING IMPLEMENTED IN | | | THIS PROJECT? | | | | | | 5) 107.2.5 FBC[AMENDED] DEMOLITION PLAN. | | | - PROVIDE DEMOLITION PLAN TO SHOW EXISTING | | | CONFIGURATION, OPENINGS BEING FILLED AND NOTES ON WHAT | | | IS BEING DEMOED. | | | - PROVIDE DETAILS TO SHOW HOW OPENINGS ARE BEING FILLED | | | IN. | | | | | | 6) PROVIDE PRODUCT APPROVALS FOR ANY NEW DOORS OR | | | WINDOWS. SHOW ON PLANS WHERE NEW DOORS OR WINDOWS ARE | | | BEING INSTALLED AND THE SIZES OF OPENINGS. | | | | | | 7)IS ANTHING HAPPENING WITH THE ROOF? IF SO PROVIDE | | | PRODUCT APPROVALS FOR ROOFING, OR INDICATE THAT THEY | | | WILL BE SUBMITTED WITH ROOFING SUB-PERMIT | | | | | | A FULL REVIEW WILL BE PROVIDED UPON RECEIPT OF MORE | | | COMPLETE DRAWINGS, NOTES AND DESCRIPTIONS. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-03-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-03-27 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-03-27 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-02-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-02-21 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-02-21 |
Time |
11:23 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-12-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-10 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-10 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2019-12-10 15:39:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM OF EXISTING SERVICE, SHOWING | | | ALL DETAILS OF SERVICE EQUIPMENT, UNDERGROUND OR | | | OVERHEAD SERVICE, WIRE AND BREAKER SIZES FOR SERVICE | | | AND FEED TO ANY SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, | | | SHOW INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, | | | 230, 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 2. PLAN SHOWS SEVERAL CIRCUITS GOING TO APARTMENT. A | | | BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A BRANCH | | | CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 3. PANEL SCHEDULE SHOWS A 125 AMP MAIN ON A 100 AMP | | | PANEL. THIS PANEL IS NOT RATED FOR 125 AMPS. PROVIDE | | | CORRECTION. NEC 110.3, 408.30 | | | 4. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | | 801.2, OR 901.2 AS APPLICABLE. | | | 5. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY THE PERSON RESPONSIBLE | | | FOR THE DESIGN. EACH SHEET SHOULD ALSO SHOW THE ADDRESS | | | OF THE PROJECT. PROVIDE CORRECTION. WPB FBC 107.1; FS | | | 471/481 | | | 6. PROVIDE ACCURATE LOAD CALCULATION FOR EXISTING | | | SERVICE, INCLUDE EXISTING AND NEW LOADS TO CONFIRM | | | CAPACITY OF SERVICE IS ADEQUATE. LOAD CALCULATION | | | SHOULD BE IN COMPLIANCE WITH FBC RE 3602.2. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2020-05-06 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2020-05-06 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-04-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-04-03 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-03-19 |
Time |
08:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-02-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-01-28 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2020-02-04 14:52:50 | TAKEN TO ELEC. | | 2020-01-29 14:52:08 | R15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-12-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-14 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-06-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-06-12 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-06-12 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2020-06-12 14:21:05 | 06/12/2020 | | | NO FEES DUE. MU-2020-016470. JG. | | 2020-05-06 16:32:49 | GAVE SHELIA ONE SET FOR IMPACT FEE REVIEW. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-16 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-16 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2019-12-16 11:22:35 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2020-05-06 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2020-05-06 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2020-05-06 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2020-03-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-03-24 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-03-24 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2020-03-24 13:52:57 | | | | | | | PLEASE ADDRESS THE PREVIOUS REVIEWERS COMMENTS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | | | | | | | | | | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19110703 | | | 2/10/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1ST REVIEW COMMENTS PRINTED BELOW STILL EXIST- PLEASE | | | COMPLY. | | | | | | 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED FOR REVIEW- | | | SECTION 107.2.1 WPB. | | | | | | 2) PLEASE IDENTIFY THE LARGE ROOM ON THE SUBMITTED | | | OWNER/BUILDER PLAN- SECTION 107.2.1 WPB. | | | | | | 3) INDICATE HOW THE LARGE ROOM WILL BE VENTILATED- | | | NATURALLY OR MECHANICALLY. IF USING NATURAL SHOW | | | COMPLIANCE WITH SECTION R303.1 FBC RES AND VERIFY THE | | | OPENABLE AREA (WINDOWS, DOORS) TO THE OUTDOORS IS NOT | | | LESS THAN 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. | | | | | | 4) REFER TO SECTION R303.10 FBC RES AND INDICATE HOW | | | HEATING WILL BE PROVIDED TO THE NEW ADDITION. PLEASE | | | NOTE THAT PORTABLE SPACE HEATERS SHALL NOT BE USED TO | | | ACHIEVE COMPLIANCE. | | | | | | 5) REFER TO SECTION R303.3 AND INDICATE HOW THE | | | BATHROOM WILL BE VENTILATED- NATURALLY THROUGH AN | | | OPERABLE WINDOW OR MECHANICALLY PER SECTION M1507 FBC | | | RES. | | | | | | 6) THE CONVERSION OF THE GARAGE INTO HABITAL, | | | CONDITIONED SPACE IS CLASSIFED AS BOTH AN ADDITION AND | | | A CHANGE OF OCCUPANCY PER SECTIONS R202, R503.2, AND | | | R505.2 FBC EC. PLEASE PROVIDE AN ENERGY COMPLAINCE | | | REPORT IN ACCORDANCE WITH SECTION R101.5.1.1 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-02-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-02-10 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-02-10 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2020-02-10 12:43:46 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19110703 | | | 2/10/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1ST REVIEW COMMENTS PRINTED BELOW STILL EXIST- PLEASE | | | COMPLY. | | | | | | 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED FOR REVIEW- | | | SECTION 107.2.1 WPB. | | | | | | 2) PLEASE IDENTIFY THE LARGE ROOM ON THE SUBMITTED | | | OWNER/BUILDER PLAN- SECTION 107.2.1 WPB. | | | | | | 3) INDICATE HOW THE LARGE ROOM WILL BE VENTILATED- | | | NATURALLY OR MECHANICALLY. IF USING NATURAL SHOW | | | COMPLIANCE WITH SECTION R303.1 FBC RES AND VERIFY THE | | | OPENABLE AREA (WINDOWS, DOORS) TO THE OUTDOORS IS NOT | | | LESS THAN 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. | | | | | | 4) REFER TO SECTION R303.10 FBC RES AND INDICATE HOW | | | HEATING WILL BE PROVIDED TO THE NEW ADDITION. PLEASE | | | NOTE THAT PORTABLE SPACE HEATERS SHALL NOT BE USED TO | | | ACHIEVE COMPLIANCE. | | | | | | 5) REFER TO SECTION R303.3 AND INDICATE HOW THE | | | BATHROOM WILL BE VENTILATED- NATURALLY THROUGH AN | | | OPERABLE WINDOW OR MECHANICALLY PER SECTION M1507 FBC | | | RES. | | | | | | 6) THE CONVERSION OF THE GARAGE INTO HABITAL, | | | CONDITIONED SPACE IS CLASSIFED AS BOTH AN ADDITION AND | | | A CHANGE OF OCCUPANCY PER SECTIONS R202, R503.2, AND | | | R505.2 FBC EC. PLEASE PROVIDE AN ENERGY COMPLAINCE | | | REPORT IN ACCORDANCE WITH SECTION R101.5.1.1 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-12-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-12-19 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-12-19 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2019-12-19 14:56:34 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19110703 | | | 12/19/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS HAVE BEEN SUBMITTED FOR REVIEW- | | | SECTION 107.2.1 WPB. | | | | | | 2) PLEASE IDENTIFY THE LARGE ROOM ON THE SUBMITTED | | | OWNER/BUILDER PLAN- SECTION 107.2.1 WPB. | | | | | | 3) INDICATE HOW THE LARGE ROOM WILL BE VENTILATED- | | | NATURALLY OR MECHANICALLY. IF USING NATURAL SHOW | | | COMPLIANCE WITH SECTION R303.1 FBC RES AND VERIFY THE | | | OPENABLE AREA (WINDOWS, DOORS) TO THE OUTDOORS IS NOT | | | LESS THAN 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. | | | | | | 4) REFER TO SECTION R303.10 FBC RES AND INDICATE HOW | | | HEATING WILL BE PROVIDED TO THE NEW ADDITION. PLEASE | | | NOTE THAT PORTABLE SPACE HEATERS SHALL NOT BE USED TO | | | ACHIEVE COMPLIANCE. | | | | | | 5) REFER TO SECTION R303.3 AND INDICATE HOW THE | | | BATHROOM WILL BE VENTILATED- NATURALLY THROUGH AN | | | OPERABLE WINDOW OR MECHANICALLY PER SECTION M1507 FBC | | | RES. | | | | | | 6) THE CONVERSION OF THE GARAGE INTO HABITAL, | | | CONDITIONED SPACE IS CLASSIFED AS BOTH AN ADDITION AND | | | A CHANGE OF OCCUPANCY PER SECTIONS R202, R503.2, AND | | | R505.2 FBC EC. PLEASE PROVIDE AN ENERGY COMPLAINCE | | | REPORT IN ACCORDANCE WITH SECTION R101.5.1.1 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-01-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-01-30 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-01-30 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2020-01-30 07:27:12 | 01/30/20 REVIEWED FOR CODE COMPLIANCE | | | (PLUMBING/BACKFLOW) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 6:30 AM 7:30 / 2:00 PM TO 5:00 PM | | | [email protected] | | | 561-701-6437 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-12-03 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-12-03 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2019-12-03 10:14:46 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 54 = NATIONAL FUEL GAS CODE | | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | | NFPA 99 = HEALTH CARE FACILITIES CODE | | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 19110703 4101 GARDEN AVE | | | | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | RE: PLUMBING RISER | | | 1. PER WPB FBC 107.2.1, A CODE COMPLIANT PLUMBING RISER | | | DIAGRAM SHALL BE PROVIDED SHOWING ALL FIXTURE DRAINS | | | WITH TRAPS (EXCEPT THAT THE WATER CLOSET AS AN | | | INTEGRALLY TRAPPED FIXTURE SHALL NOT SHOW A TRAP), | | | FIXTURE BRANCHES AND BUILDING DRAIN. ALL COMPONENTS | | | SHALL BE SIZED. DRAWING SHALL COMPLY WITH FBC RES | | | CHAPTERS 30 AND 31. | | | 2. THE KITCHEN SINK SHALL CONNECT DOWNSTREAM OF THE | | | BATHROOM FIXTURES PER FBC RES P3108.1. | | | 3. AT LEAST ONE VENT SHALL BE EXTENDED TO THE BUILDING | | | EXTERIOR IN ACCORDANCE WITH FBC RES P3102.1. | | | 4. THE BUILDING SEWER SHALL CONNECT TO A SEWER LATERAL | | | PROVIDED BY WPB PUBLIC UTILITIES OR TO THE EXISTING | | | BUILDING SEWER SERVICING THE MAIN HOUSE. CONFIRM | | | ELEVATIONS WILL ALLOW GRAVITY DRAIN. | | | 5. PER WPB FBC 107.2.1, SHOW LOCATION, SIZE AND TYPE OF | | | WATER HEATER ON FLOOR PLAN. | | | 6. PER WPB FBC 107.2.1, DRAWINGS SHALL HAVE THE PRINTED | | | NAME AND SIGNATURE OF THE DESIGNER. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19110703 4101 GARDEN AVE | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2020-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-02-04 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-02-04 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2020-02-04 14:50:37 | NEW ROOF NOT SHOWN ON THE DRAWINGS |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-12-16 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-16 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-16 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2019-12-16 11:21:06 | SEE BUILDING COMMENT #7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-04-03 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-04-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-02-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2020-02-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-14 12:31:55 | ******************************ZONING REVIEW | | | FAILED***************************** | | | | | | THE FLOOR PLAN THAT WAS SUBMITTED FOR THE PROPOSED | | | LIVABLE SPACE IN THE ACCESSORY BUILDING AT THE REAR OF | | | THE PROPERTY IS NOT CLEAR. | | | | | | THIS PROPERTY IS ZONED SINGLE FAMILY (SF-7), SO THERE | | | CAN ONLY BE ONE UNIT AND ONE FULL KITCHEN ON THE | | | PROPERTY. | | | | | | THE PROPOSED LIVABLE SPACE IS NOT PERMITTED TO HAVE A | | | FULL KITCHEN. YOU CAN HAVE A SMALL SINK, SMALL | | | REFRIGERATOR, AND MICROWAVE. ALL OTHER APPLIANCES ARE | | | NOT PERMITTED. | | | | | | ALANA WOOTEN | | | PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-11-25 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2019-11-26 09:15:27 | ***************************ZONING REVIEW | | | FAILED*************************************** | | | | | | PROVIDE A FULL DIMENSIONED FLOOR PLAN OF THE PROPOSED | | | LIVABLE SPACE. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|