Plan Review Details - Permit 19110644
| Plan Review Stops For Permit 19110644 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-02-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-07 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-03 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-03 |
Time |
17:40 |
Sent To |
I |
|
| Notes |
| 2020-02-03 18:38:47 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | SUBMITTAL FOR THE EXTERIOR FOAM BAND AND TRIM IS | | | DENIED. | | | | | | 1) COMPLIED. | | | | | | 2) THE DOCUMENTS THAT WERE SUBMITTED DO NOT ADDRESS THE | | | PERFORMANCE REQUIREMENTS OF THE DESIGNER'S | | | SPECIFICATIONS, SPECIFICALLY ASTM E2568, ICC-ES AC239 | | | AND ASTM E84. SUBMIT TEST REPORTS, ICC EVALUATION | | | REPORTS OR OTHER APPROVED DATA FROM AN INDEPENDENT | | | AGENCY TO SHOW COMPLIANCE. THE MANUFACTURER'S BROCHURES | | | ARE NOT ACCEPTABLE. SEE FBC 2603.5 | | | | | | 3) THIS EVALUATION REPORT IS REQUIRED TO BE SUBMITTED | | | FOR THE PAREX SYSTEM. NOTE: SEE ICC-ES EVALUATION | | | REPORT ESR-2562. | | | HTTPS://ICC-ES.ORG/REPORT-LISTING/ESR-2562/ | | | | | | 4) FBC 107.3.4 - THE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER | | | FLORIDA STATUTE 553.842 (5) ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITAL. | | | | | | 5) THE ICC EVALUATION REPORT FOR THE PARAX SYSTEM IS | | | REQUIRED TO BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. FBC 107.3.4.1 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-12-18 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-12-18 |
Time |
16:45 |
Sent To |
I |
|
| Notes |
| 2019-12-18 17:05:38 | SUBMITTAL FOR THE EXTERIOR FOAM BAND AND TRIM IS | | | DENIED. | | | | | | 1) THE PAREX EIFS WALL SYSTEM ON CONCRETE MASONRY, NOA | | | NO. 12-0214.12 EXPIRED ON AUGUST 06,2017. THE DESIGNER | | | OF RECORD HAS NOT REVIEWED AND APPROVED IT IN WRITING | | | AS REQUIRED BY FBC 107.3.4. | | | | | | 2) THE DOCUMENTS THAT WERE SUBMITTED DO NOT ADDRESS THE | | | PERFORMANCE REQUIREMENTS OF THE DESIGNER'S | | | SPECIFICATIONS, SPECIFICALLY ASTM E2568, ICC-ES AC239 | | | AND ASTM E84. SUBMIT TEST REPORTS, ICC EVALUATION | | | REPORTS OR OTHER APPROVED DATA FROM AN INDEPENDENT | | | AGENCY TO SHOW COMPLIANCE. THE MANUFACTURER'S BROCHURES | | | ARE NOT ACCEPTABLE. SEE FBC 2603.5 | | | | | | 3) NOTE: SEE ICC-ES EVALUATION REPORT ESR-2562. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2019-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-11-22 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-11-22 |
Time |
19:02 |
Sent To |
|
|
| Notes |
| 2019-11-22 19:09:27 | RECEIPT OF (4) PAGES FROM THE PROJECT SPECIFICATION | | | BOOK WITH THE DESIGNER'S REQUIREMENTS FOR EXTERIOR FOAM | | | TRIM IS ACKNOWLEDGED. THE ACTUAL MANUFACTURER'S | | | SPECIFICATIONS AND TEST REPORTS FOR THE ACTUAL FOAM | | | PRODUCTS THAT WILL BE USED ARE STILL REQUIRED TO BE | | | APPROVED BY THE DESIGNER OF RECORD AND SUBMITTED TO THE | | | BUILDING OFFICIAL FOR APPROVAL BEFORE INSTALLATION ON | | | THE BUILDING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-02-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-02-06 |
Time |
11:27 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-02-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-02-03 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-01-31 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-12-18 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-12-17 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-11-22 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-11-13 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2019-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-11-22 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-11-22 |
Time |
19:02 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |