Plan Review Details - Permit 19110599
| Plan Review Stops For Permit 19110599 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-12-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-12-23 |
Time |
|
Sent To |
P |
|
| Notes |
| 2019-12-23 09:39:24 | PASSED WITH PROVISO: | | | | | | PLEASE ADDRESS ANY OUTSTANDING PLUMBING COMMENTS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR WPB, FL 33401 (MAILING | | | ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 MOBILE: (561) 246-9525 | | | EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-12-03 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2019-12-03 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-12-03 07:09:17 | PLEASE ADDRESS PLUMBING COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-27 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-19 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2019-12-20 13:47:32 | RESUB ROUTED TO ENGINEERING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-12-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-12-03 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-11-13 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-11-14 13:30:29 | ROUTED TO PLUMBING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-01-10 |
|
|
Cont ID |
|
| Sent By |
rsklarew |
Date |
2020-01-10 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rsklarew |
Date |
2020-01-10 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-27 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-27 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2019-12-27 13:56:01 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. A GENERAL CONTRACTOR CAN NOT INSTALL A GREASE | | | INTERCEPTOR THE PERMIT SHALL ONLY BE ISSUED TO A | | | PLUMBING CONTRACTOR OR . PER FAC 589 105(A)(M) | | | THE PLANS HAVE BEEN APPROVED AND STAMPED BUT THE PERMIT | | | CAN NOT BE ISSUED UBTIL A PERMIT APPLICATION FROM A | | | PLUMBING CONTRACTOR OR SEPTIC TANK COTRACTOR IS | | | RECIEVED. | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-11-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-11-27 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-11-27 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2019-11-27 15:55:41 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. A GENERAL CONTRACTOR CAN NOT INSTALL A GREASE | | | INTERCEPTOR THE PERMIT SHALL ONLY BE ISSUED TO A | | | PLUMBING CONTRACTOR OR . PER FAC 589 105(A)(M) | | | | | | 2. SHOW LOCATION OF GREASE INTERCEPTOR ON SITE PLAN. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. PLACE NOTE ON PLAN SIZING CALCULATIONS WILL BE | | | REQUIRED ON THE BUILDOUT FOR GREASE INTERCEPTOR. PER | | | FBC PL 1003.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
|