Plan Review Details - Permit 19110517
Plan Review Stops For Permit 19110517
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-03-13 Cont ID  
Sent By rmcphers Date 2020-03-13 Time 10:13 Rev Time 0.00
Received By jbaker Date 2020-03-19 Time 13:51 Sent To  
Notes
2020-03-19 13:53:18 
 ENTERED REVIEW IN ERROR ALREADY PASSED BY ROGER
 MCPHERSON

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-01-31 Cont ID  
Sent By dbattles Date 2020-01-31 Time 12:39 Rev Time 0.00
Received By dbattles Date 2020-01-31 Time 12:39 Sent To  
Notes
2020-01-31 12:40:12PROVIDE SECOND SET OF PLANS SO I CAN STAMP AND APPROVE
 BUILDING PORTION.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-12-02 Cont ID  
Sent By dbattles Date 2019-12-02 Time 09:03 Rev Time 0.00
Received By dbattles Date 2019-11-27 Time 14:25 Sent To  
Notes
2019-12-02 09:04:03BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 19110577
 REVIEWED: DECEMBER 2, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 1) 1004.1 DESIGN OCCUPANT LOAD. IN DETERMINING MEANS OF
 EGRESS REQUIREMENTS, THE NUMBER OF OCCUPANTS FOR WHOM
 MEANS OF EGRESS FACILITIES ARE PROVIDED SHALL BE
 DETERMINED IN ACCORDANCE WITH THIS SECTION
 -PLEASE PROVIDE DATA FOR EGREES, SQ. FOOTAGE BREAKDOWN
 OF SPACES AREAS MAY INCLUDE STORAGE AND DAY CARE AREA.
 SHOW SQ. FOOTAGE PER OCCUPANT EACH OCCUPANCY. THIS WILL
 ESTABLISH MAXIMUM OCCUPANT LOAD.
  
 2) 466.2 CLOSET DOORS. EVERY CLOSET DOOR LATCH SHALL BE
 SUCH THAT CLIENTS CAN OPEN THE DOOR FROM INSIDE THE
 CLOSET.
 -SHOW ON PLAN WHICH DOORS THIS APPLIES.
  
 3) 466.3 BATHROOM DOORS. EVERY BATHROOM DOOR LOCK SHALL
 BE DESIGNED TO PERMIT OPENING OF THE LOCKED DOOR FROM
 THE OUTSIDE IN AN EMERGENCY. THE OPENING DEVICE SHALL
 BE READILY ACCESSIBLE TO THE STAFF.
 -SHOW ON PLAN WHICH DOORS THIS APPLIES.
  
 4) 466.6.2 THE FOLLOWING ROOMS OR SPACES SHALL BE
 SEPARATED FROM THE REMAINDER OF THE BUILDING BY FIRE
 BARRIERS HAVING A FIRE-RESISTANCE RATING OF NOT LESS
 THAN 1 HOUR AND SHALL BE PROTECTED BY AN APPROVED
 AUTOMATIC FIRE-EXTINGUISHING SYSTEM. LAUNDRIES
 -SHOW ON PLAN WHICH WALLS WOULD BE 1 HOUR RATED AND HOW
 THIS IS ACHIEVED.
  
 WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  
2019-11-18 14:46:38REVIEWER, PLEASE SEE THE EMAIL CORRESPONDENCE FROM MR.
 BROWN. ADDITIONALLY, PLEASE ASSURE YOU NOTE IN THE
 REVIEW THAT THE OWNER LISTED IN BOX 3 ON THE APPLIATION
 FORM SHOULD BE CHANGED BY THE APPLICANT TO IDENTIFY THE
 THE LEASE HOLDER APPLICANT AND NOT THE FEE SIMPLE TITLE
 HOLDER. THE FEE SIMPLE TITILE HOLDER SHOULD BE LISTEED
 IN BOX 9 ON PAGE TWO OF THE APPLICATION. THE CHILD CARE
 APPLICATION TRAVELING WITH THIS SUBMITAL SHOULD BE
 FORWARDED TO MR. BROWN AT TIME OF ISSUANCE.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2020-09-11 Cont ID  
Sent By jleahy Date 2020-09-08 Time 11:06 Rev Time 0.00
Received By jleahy Date 2020-09-08 Time 11:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2020-03-16 Cont ID  
Sent By jpearson Date 2020-03-16 Time 14:09 Rev Time 0.00
Received By jpearson Date 2020-03-16 Time 14:09 Sent To  
Notes
2020-03-16 14:09:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED (AND
 SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR
 THE DESIGN. IF NO ELECTRICAL WORK IS PROPOSED FOR THIS
 CHANGE OF OCCUPANCY, STATE THAT ON PLAN. WPB FBC
 107.2.1, 107.3.5; FS 471, 481
 2. PROVIDE ACCURATE LEGEND ON EACH COPY OF THE PLAN.
 THE CURRENT LEGEND ON THE COVER SHEET SHOWS SHEETS THAT
 ARE NOT IN THE SET. SOME SHEETS IN LEGEND ARE IN EACH
 SET TWICE. PROVIDE CORRECTION. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
 REVIEWER, PLEASE SEE THE EMAIL CORRESPONDENCE FROM MR.
 BROWN. SEE ME IF YOU HAVE QUESTIONS. SAK

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-02-11 Cont ID  
Sent By jleahy Date 2020-02-11 Time 06:54 Rev Time 0.00
Received By jleahy Date 2020-02-11 Time 06:54 Sent To  
Notes
2020-02-11 06:55:48FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) NO ELECTRICAL PLAN SUBMITTED FOR REVIEW. SUBMIT AN
 ELECTRICAL PLAN FOR REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-12-10 Cont ID  
Sent By jpearson Date 2019-12-10 Time 06:45 Rev Time 0.00
Received By jpearson Date 2019-12-10 Time 06:45 Sent To  
Notes
2019-12-10 06:45:43CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED (AND
 SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR
 THE DESIGN. WPB FBC 107.2.1, 107.3.5; FS 471, 481
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
2019-11-20 08:47:42REVIEWER, PLEASE SEE THE EMAIL CORRESPONDENCE FROM MR.
 BROWN. SEE ME IF YOU HAVE QUESTIONS. SAK

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-02-26 Cont ID  
Sent By pleduc Date 2020-02-26 Time   Rev Time 0.00
Received By pleduc Date 2020-02-26 Time 11:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2020-01-23 Cont ID  
Sent By pleduc Date 2020-01-23 Time   Rev Time 0.00
Received By pleduc Date 2020-01-23 Time 14:03 Sent To  
Notes
2020-01-23 14:17:01THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) THERE IS ONLY ONE SET OF RESUBMITTED PLANS, TWO SETS
 ARE REQUIRED.
  
 PLEASE SUBMIT A COMPLETE 2ND SET.
  
  
  
 2) THE DETAIL OF THE EXISITNG FA SYSTEM DOES NOT APPEAR
 TO MEET THE REQUIREMENT OF NFPA 101, CH 9
  
 I AM NOT CERTAIN THAT THE INSTALLED SYSTEM BY XFINITY
 MEETS THE REQUIRMENT OF NFPA 101, CH 9 AND NFPA 72
  
 9.6.1.3 FIRE ALARM SYSTEMS REQUIRED BY THIS CODE SHALL
 BE INSTALLED,
 TESTED, AND MAINTAINED IN ACCORDANCE WITH THE
 APPLICABLE
 REQUIREMENTS OF NFPA 70, NATIONAL ELECTRICAL CODE, AND
 NFPA
 72, NATIONAL FIRE ALARM AND SIGNALING CODE, UNLESS IT
 IS AN
 APPROVED EXISTING INSTALLATION, WHICH SHALL BE
 PERMITTED TO BE
 CONTINUED IN USE.
  
  
 9.6.2 SIGNAL INITIATION.
 9.6.2.1 WHERE REQUIRED BY OTHER SECTIONS OF THIS CODE,
 ACTUATION
 OF THE FIRE ALARM SYSTEM SHALL OCCUR BY ANY OR ALL OF
 THE FOLLOWING
 MEANS OF INITIATION BUT SHALL NOT BE LIMITED TO SUCH
 MEANS:
 (1) MANUAL FIRE ALARM INITIATION
 (2) AUTOMATIC DETECTION
 (3) EXTINGUISHING SYSTEM OPERATION
 9.6.2.2 MANUAL FIRE ALARM BOXES SHALL BE USED ONLY FOR
 FIREPROTECTIVE
 SIGNALING PURPOSES. COMBINATION FIRE ALARM AND GUARD?S
 TOUR STATIONS SHALL BE PERMITTED.
 9.6.2.3 A MANUAL FIRE ALARM BOX SHALL BE PROVIDED AS
 FOLLOWS,
 UNLESS MODIFIED BY ANOTHER SECTION OF THIS CODE:
 (1) FOR NEW ALARM SYSTEM INSTALLATIONS, THE MANUAL FIRE
 ALARM
 BOX SHALL BE LOCATED WITHIN 60 IN. (1525 MM) OF EXIT
 DOORWAYS.
 (2) FOR EXISTING ALARM SYSTEM INSTALLATIONS, THE MANUAL
 FIRE ALARM
 BOX EITHER SHALL BE PROVIDED IN THE NATURAL EXIT ACCESS
 PATH
 NEAR EACH REQUIRED EXIT OR WITHIN 60 IN. (1525 MM) OF
 EXIT
 DOORWAYS.
  
 9.6.3.5 UNLESS OTHERWISE PROVIDED IN 9.6.3.5.1 THROUGH
 9.6.3.5.8,
 NOTIFICATION SIGNALS FOR OCCUPANTS TO EVACUATE SHALL BE
 AUDIBLE, AND
 VISIBLE SIGNALS IN ACCORDANCE WITH NFPA 72, NATIONAL
 FIRE ALARM
 AND SIGNALING CODE.
  
 9.6.3.7 AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL BE
 OF SUCH
 CHARACTER AND SO DISTRIBUTED AS TO BE EFFECTIVELY HEARD
 ABOVE THE
 AVERAGE AMBIENT SOUND LEVEL THAT EXISTS UNDER NORMAL
 CONDITIONS
 OF OCCUPANCY.
  
 16.3.4.5 DETECTION. A SMOKE DETECTION SYSTEM IN
 ACCORDANCE
 WITH SECTION 9.6 SHALL BE INSTALLED IN DAY-CARE
 OCCUPANCIES, OTHER
 THAN THOSE HOUSED IN ONE ROOM HAVING AT LEAST ONE DOOR
 OPENING
 DIRECTLY TO THE OUTSIDE AT GRADE PLANE OR TO AN
 EXTERIOR EXIT ACCESS
 BALCONY IN ACCORDANCE WITH 7.5.3, AND SUCH SYSTEM SHALL
 COMPLY
 WITH BOTH OF THE FOLLOWING:
 (1) DETECTORS SHALL BE INSTALLED ON EACH STORY IN FRONT
 OF THE DOORS
 TO THE STAIRWAYS AND IN THE CORRIDORS OF ALL FLOORS
 OCCUPIED BY
 THE DAY-CARE OCCUPANCY.
 (2) DETECTORS SHALL BE INSTALLED IN LOUNGES, RECREATION
 AREAS, AND
 SLEEPING ROOMS IN THE DAY-CARE OCCUPANCY.
  
 PLEASE PROVIDE DETAILS AND THE PERMIT NUMBER FOR
 CHANGES.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-11-20 Cont ID  
Sent By pleduc Date 2019-11-20 Time   Rev Time 0.00
Received By pleduc Date 2019-11-20 Time 12:12 Sent To  
Notes
2019-11-20 12:28:29THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS NO INDICATIONS OF A FIRE ALARM AND THAT IT
 IS MONITORED BY CENTRAL MONITORING STATION.
  
 PER NFPA 101, CH 16, NEW DAY CARE OCCUPANCY
  
 16.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 16.3.4.1 GENERAL. DAY-CARE OCCUPANCIES, OTHER THAN
 DAY-CARE
 OCCUPANCIES HOUSED IN ONE ROOM HAVING AT LEAST ONE DOOR
 OPENING DIRECTLY TO THE OUTSIDE AT GRADE PLANE OR TO AN
 EXTERIOR
 EXIT ACCESS BALCONY IN ACCORDANCE WITH 7.5.3, SHALL BE
 PROVIDED
 WITH A FIRE ALARM SYSTEM IN ACCORDANCE WITH SECTION
 9.6.
  
 THERE ARE MULTIPLE ROOMS INDICATED, A FIRE ALARM IS
 REQUIRED.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGE TO
 INSTALL UNDER A SEPARATE PERMIT.
  
  
  
 2) THERE ARE NO INDICATIONS OF THE DOOR HARDWARE
  
 PER NFPA 101
  
 16.2.2.2.4* DOOR LATCHES. EVERY DOOR LATCH TO CLOSETS,
 STORAGE
 AREAS, KITCHENS, AND OTHER SIMILAR SPACES OR AREAS
 SHALL BE SUCH
 THAT CLIENTS CAN OPEN THE DOOR FROM INSIDE THE SPACE OR
 AREA.
 16.2.2.2.5 BATHROOM DOORS. EVERY BATHROOM DOOR LOCK
 SHALL BE
 DESIGNED TO ALLOW OPENING OF THE LOCKED DOOR FROM THE
 OUTSIDE
 BY AN OPENING DEVICE THAT SHALL BE READILY ACCESSIBLE
 TO THE STAFF.
  
 PLEASE REVIEW AND PROVIDE A NOTE OF COMPLIANCE
  
  
  
 3) THERE APPEARS TO BE STAIRS LEADING TO A 2ND FL THAT
 IS ATTACHED TO OR WITHIN ONE OF THE DAY CARE ROOMS.
  
 WILL THIS 2ND FLOOR AREA BE USED?
  
 IF NOT, HOW WILL IT BE SEPARATED/CONTROLED FROM USE?
  
 PLEASE REVIEW AND PROVIDE SPECIFIC DETAILS AND
 NARRATIVE.
  
  
  
 4) THERE IS AN EXIT DOOR LEADING TO A PORCH INDICATED.
  
 THERE IS NO INDICATION OF HOW TO EXIT THE PORCH AREA.
  
 PLEASE PROVIDE DETAILS FOR WHEN YOU EXIT ONTO THE
 PORCH, HOW WILL YOU THEN EXIT THE PORCH?
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-09-08 Cont ID  
Sent By jleahy Date 2020-09-08 Time 11:11 Rev Time 0.00
Received By jleahy Date 2020-08-25 Time 12:50 Sent To  
Notes
2020-08-27 12:51:11CONVERTED TO DIGITAL. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-19 Cont ID  
Sent By lmarchan Date 2020-03-19 Time 14:34 Rev Time 0.00
Received By lmarchan Date 2020-02-21 Time 10:00 Sent To  
Notes
2020-02-25 10:00:27B04

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-11 Cont ID  
Sent By jleahy Date 2020-02-11 Time 06:55 Rev Time 0.00
Received By jleahy Date 2020-01-21 Time 15:47 Sent To  
Notes
2020-01-22 15:48:34B04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-12-10 Time   Rev Time 0.00
Received By skennedy Date 2019-11-12 Time 14:31 Sent To  
Notes
2019-11-26 11:29:01B04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2021-07-06 Cont ID  
Sent By lmarchan Date 2021-07-06 Time 15:08 Rev Time 0.00
Received By lmarchan Date 2020-11-23 Time 16:53 Sent To  
Notes
2021-07-06 15:08:46RECEIPT MU-2020-048559 - $3847.79 - PAID
2020-11-23 16:53:2711/23/20 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2020-01-31 Cont ID  
Sent By dbattles Date 2020-01-31 Time 12:40 Rev Time 0.00
Received By dbattles Date 2020-01-31 Time 12:40 Sent To  
Notes
2020-01-31 12:42:46ONCE ALL TRADES APPROVE CHECK OUT ONE SET AND TAKE TO
 PBC IMPACT REVIEW OFFICE.
 PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE
 FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE
 FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION
 /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT
 AS APPLICABLE.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-12-02 Cont ID  
Sent By dbattles Date 2019-12-02 Time 09:04 Rev Time 0.00
Received By dbattles Date 2019-12-02 Time 09:04 Sent To  
Notes
2019-12-02 09:05:12109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2020-09-08 Cont ID  
Sent By medwards Date 2020-09-08 Time 14:19 Rev Time 0.00
Received By medwards Date 2020-09-08 Time 14:19 Sent To  
Notes
2020-09-08 14:21:25ACCORDING TO THE OWNER THIS IS AN EXISTING RESIDENCE
 THAT SHE LIVES IN AND HAS A DAYCARE. ALL THE COMMENTS
 FROM CYCLE 3 ARE EXISTING AND NOTHING NEEDS TO BE DONE.
  
 MICHAEL EDWARDS

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2020-09-01 Cont ID  
Sent By medwards Date 2020-09-01 Time 09:23 Rev Time 0.00
Received By medwards Date 2020-09-01 Time 09:23 Sent To  
Notes
2020-09-01 09:25:50I DO NOT SEE THE UPDATED DRAWING SHOWING THE BATHROOM
 EXHAUST FAN OR THE DIFFUSERS IN EACH OCCUPIABLE ROOM
 AND THE ACU. PLEASE INCLUDE THE MENTIONED DRAWING IN
 YOUR SUBMITTAL.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2020-03-02 Cont ID  
Sent By ccole Date 2020-03-02 Time 08:37 Rev Time 0.00
Received By ccole Date 2020-03-02 Time 08:37 Sent To  
Notes
2020-03-02 08:39:083RD REVIEW FBC-2017 MECHANICAL
 PERMIT #19110517
 3/2//20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 COMMENTS FROM THE 2ND REVIEW PRINTED BELOW HAVE NOT
 BEEN ADDRESSED- PLEASE COMPLY.
  
 1) M-1: MECHANICAL VENTILATION IS REQUIRED FOR THE
 ENLARGED BATHROOM IN ACCORDANCE WITH SECTION 1203.5.2.1
 FBC B. PLEASE PROVIDE A MINIMUM 50 CFM EXHAUST FAN- SEE
 TABLE 403.3.1.1 FBC M.
  
 2) M-1: VERIFY THAT ALL OCCUPIED ROOMS AND SPACES ARE
 PROVIDED WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS
 CAPABLE OF MAINTAINING AN INDOOR TEMPERATURE OF NOT
 LESS THAN 68 DEGREES F- SECTION 309.1 FBC M.
  
 3) M-1: PLEASE RESUBMIT TWO SETS OF CORRECTED PLANS-
 SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK "VOID" OR "OLD" ON THEM. PLEASE
 RETAIN THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS.
 THIS PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-02-04 Cont ID  
Sent By ccole Date 2020-02-04 Time 15:47 Rev Time 0.00
Received By ccole Date 2020-02-04 Time 15:40 Sent To  
Notes
2020-02-04 15:54:102ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19110517
 2/4/20
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) M-1: MECHANICAL VENTILATION IS REQUIRED FOR THE
 ENLARGED BATHROOM IN ACCORDANCE WITH SECTION 1203.5.2.1
 FBC B. PLEASE PROVIDE A MINIMUM 50 CFM EXHAUST FAN- SEE
 TABLE 403.3.1.1 FBC M.
  
 2) M-1: VERIFY THAT ALL OCCUPIED ROOMS AND SPACES ARE
 PROVIDED WITH ACTIVE OR PASSIVE SPACE-HEATING SYSTEMS
 CAPABLE OF MAINTAINING AN INDOOR TEMPERATURE OF NOT
 LESS THAN 68 DEGREES F- SECTION 309.1 FBC M.
  
 3) M-1: PLEASE RESUBMIT TWO SETS OF CORRECTED PLANS-
 SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK "VOID" OR "OLD" ON THEM. PLEASE
 RETAIN THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS.
 THIS PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-12-05 Cont ID  
Sent By ccole Date 2019-12-05 Time 15:16 Rev Time 0.00
Received By ccole Date 2019-12-05 Time 15:16 Sent To  
Notes
2019-12-05 15:44:081ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19110517
 12/5/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE CHANGE OF OCCUPANCY FROM R-3 TO E-DAY CARE MAY
 RESULT IN AN INCREASE IN REQUIRED VENTILATION FOR ALL
 OCCUPIED ROOMS AND SPACES OF THE OCCUPANCY. PLEASE
 REFER TO SECTION 1009.1 FBC EX AND PROVIDE MINIMUM
 VENITLATION CALCULATIONS USING EITHER THE NATURAL
 VENTILATION METHOD PER SECTION 402 FBC M, OR THE
 MECHANICAL VENTILATION METHOD PER SECTION 403 FBC M.
  
 PLEASE SHOW THE CALCULATIONS ON THE PLAN. IF USING THE
 MECHANICAL METHOD PER TABLE 403.3.1.1, PROVIDE A
 SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED CFMS
 OF OUTDOOR AIR.
  
 2) SUBMIT MECHANICAL PLANS SHOWING ALL PLANNED OR
 REQUIRED ALTERATIONS TO THE EXISTING HVAC AND
 MECHANICAL SYSTEMS- SECTION 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
2019-11-20 08:47:57REVIEWER, PLEASE SEE THE EMAIL CORRESPONDENCE FROM MR.
 BROWN. SEE ME IF YOU HAVE QUESTIONS. SAK

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-03-19 Cont ID  
Sent By jbaker Date 2020-03-19 Time 13:54 Rev Time 0.00
Received By jbaker Date 2020-03-19 Time 13:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-01-30 Cont ID  
Sent By jesmith Date 2020-01-30 Time 15:45 Rev Time 0.00
Received By jesmith Date 2020-01-30 Time 15:28 Sent To  
Notes
2020-01-30 15:29:27FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 CCFH= CHILD CARE FACILITY HANDBOOK
  
  
 2ND REVIEW
  
 PLUMBING COMMENTS: DENIED
 FBC EX 1006.1
 ACCESSIBILITY IN PORTIONS OF BUILDINGS UNDERGOING A
 CHANGE OF OCCUPANCY CLASSIFICATION SHALL COMPLY WITH
 THE PROVISIONS OF THE FLORIDA BUILDING CODE,
 ACCESSIBILITY.
 1. BATHROOM SHALL COMPLY WITH ACCESSIBILITY
 REQUIREMENTS IN ACCORDANCE WITH FBC ACC. PER WPB FBC
 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC CHAPTERS 3 AND
 6 PROVIDE DETAILS INDICATING THE FOLLOWING:
 A. THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2
 B. CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 C. THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL PER FBC ACC 604.5.1
 D. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 E. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
 HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH 309.
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET PER FBC ACC 604.6
 F. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 G. LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE
 FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34
 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 H. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND PER FBC ACC 603.3.
 I. BATHTUB SHALL BE PROVIDED GRAB BARS, REMOVABLE SEAT
 AND CONTROLS/SHOWER SPRAY UNIT IN ACCORDANCE WITH FBC
 ACC 607.4.2, 607.4.2.1, 607.4.2.2, 607.4.2.3, 607.5 AND
 607.6MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
 J. SHOW TURNING SPACE COMPLYING WITH FBC ACC 304.3.1 OR
 304.3.2.
 K. DOORS SHALL NOT BE PERMITTED TO SWING INTO TURNING
 SPACES PER FBC ACC 304.4.
 L. SHOW CLEAR FLOOR SPACES FOR TUB AND LAVATORY. THE
 CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES (760 MM)
 MINIMUM BY 48 INCHES (1220 MM) MINIMUM AND COMPLY WITH
 FBC ACC SECTION 305.
  
 FBC EX 1010.1
 WHERE THE OCCUPANCY OF AN EXISTING BUILDING OR PART OF
 AN EXISTING BUILDING IS CHANGED SUCH THAT THE NEW
 OCCUPANCY IS SUBJECT TO INCREASED OR DIFFERENT PLUMBING
 FIXTURE REQUIREMENTS OR TO INCREASED WATER SUPPLY
 REQUIREMENTS IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, PLUMBING, THE NEW OCCUPANCY SHALL COMPLY WITH THE
 INTENT OF THE RESPECTIVE FLORIDA BUILDING CODE,
 PLUMBING PROVISIONS.
 1. PER WPB FBC 107.2.1, PROVIDE A SANITARY RISER
 DIAGRAM AND PLAN VIEW SHOWING THE REVISED SANITARY
 PIPING AND FIXTURE LAYOUT TO ACCOMMODATE THE LAYOUT OF
 THE ACCESSIBLE BATHROOM. COMPLY WITH FBC PL CHAPTER 7
 AND CHAPTER 9.
 2. PER FBC PL 416.5, PROVIDE TEMPERED WATER FROM THE
 LAVATORY. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3.
 3. PER FBC PL 424.3, PROVIDE INDIVIDUAL SHOWER OR
 TUB-SHOWER COMBINATION VALVES THAT IS
 BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION
 BALANCED-PRESSURE/THERMOSTATIC VALVES AND CONFORM TO
 THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA
 B125.16 OR ASME A112.18.1/CSA B125.1 AND SHALL BE
 INSTALLED AT THE POINT OF USE. SHOWER AND TUB-SHOWER
 COMBINATION VALVES REQUIRED BY THIS SECTION SHALL BE
 EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUM SETTING OF
 THE VALVE TO 120?F (49?C), WHICH SHALL BE FIELD
 ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER?S
 INSTRUCTIONS. IN-LINE THERMOSTATIC VALVES SHALL NOT BE
 UTILIZED FOR COMPLIANCE WITH THIS SECTION.
 4. PER WPB FBC 107.1.2, PROVIDE FOR REVIEW, PROVIDE
 DATA FOR EGRESS, TO INCLUDE BREAKDOWN FOR STORAGE AND
 DAY CARE AREA AS WELL AS OCCUPANCY E TO ESTABLISH
 MAXIMUM OCCUPANT LOAD FOR THE STRUCTURE WHICH SHALL BE
 APPLICABLE TO MINIMUM PLUMBING REQUIREMENTS.IT WILL BE
 IMPORTANT TO SHOW, IF THERE IS ANOTHER BATHROOM ON THE
 SECOND FLOOR, AS THIS MAY BE HELPFUL IN MEETING MINIMUM
 FIXTURE REQUIREMENTS IF NEED BE BASED ON FINAL
 OCCUPANCY DETERMINATION.
  
 AS THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN
 SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 DESIGNER PER WPB FBC 107.2.1.
  
 INFORMATIONAL COMMENTS
 1. PLEASE REFER TO FAC 65C-22.001, REGARDING THE ?CHILD
 CARE FACILITY HANDBOOK? BELOW. THERE IS A KITCHEN IN
 THE STRUCTURE. IF THE FACILITY IS PREPPING/HANDLING
 FOOD FOR THE CLIENTS, THEN PER CCFH SECTION 3.9 (7) A
 SEPARATE HAND WASHING SINK IS REQUIRED. IF THIS IS THE
 CASE, THEN THE SANITARY RISER DIAGRAM AND PLAN VIEW
 SHALL INCLUDE THE HAND SINK.
 2. PLEASE REFER TO FAC 65C-22.001, REGARDING THE ?CHILD
 CARE FACILITY HANDBOOK? BELOW. PER CCFH SECTION 3.7 (1)
 PROVIDE EASY ACCESS FOR CHILDREN USING THE TOILET
 FACILITIES; THIS MAY BE ACCOMPLISHED BY PROVIDING
 STRUCTURES THAT ARE SAFELY CONSTRUCTED AND HAVE AN
 IMPERVIOUS SURFACE THAT CAN BE EASILY CLEANED AND
 SANITIZED. STRUCTURES SHOULD BE IN PLACE FOR STATE
 INSPECTION.
 3. PLEASE REFER TO FAC 65C-22.001, REGARDING THE ?CHILD
 CARE FACILITY HANDBOOK? BELOW. PER CCFH SECTION 3.9.8
 PROVIDE CLEAN, SANITARY DRINKING WATER READILY
 ACCESSIBLE AREAS, THROUGHOUT THE DAY. SINK/WATER
 FOUNTAIN COMBINATIONS ARE PROHIBITED FOR
 HANDWASHING SINKS THAT ARE USED FOR HYGIENE PROCEDURES
 AFTER TOILETING OR DIAPER
 CHANGING.
  
 FS 402.305 LICENSING STANDARDS; CHILD CARE FACILITIES.
 (5) PHYSICAL FACILITIES.--MINIMUM STANDARDS SHALL
 INCLUDE REQUIREMENTS FOR BUILDING CONDITIONS, INDOOR
 PLAY SPACE, OUTDOOR PLAY SPACE, NAPPING SPACE,
 "BATHROOM FACILITIES", "FOOD PREPARATION FACILITIES",
 OUTDOOR EQUIPMENT, AND INDOOR EQUIPMENT. BECAUSE OF THE
 NATURE AND DURATION OF DROP-IN CHILD CARE, OUTDOOR PLAY
 SPACE AND OUTDOOR EQUIPMENT SHALL NOT BE REQUIRED FOR
 LICENSURE; HOWEVER, IF SUCH PLAY SPACE AND EQUIPMENT
 ARE PROVIDED, THEN THE MINIMUM STANDARDS SHALL APPLY TO
 DROP-IN CHILD CARE. WITH RESPECT TO MINIMUM STANDARDS
 FOR PHYSICAL FACILITIES OF A CHILD CARE PROGRAM FOR
 SCHOOL-AGE CHILDREN WHICH IS OPERATED IN A PUBLIC
 SCHOOL FACILITY, THE DEPARTMENT SHALL ADOPT THE STATE
 UNIFORM BUILDING CODE FOR PUBLIC EDUCATIONAL FACILITIES
 CONSTRUCTION AS THE MINIMUM STANDARDS, REGARDLESS OF
 THE OPERATOR OF THE PROGRAM. THE LEGISLATURE INTENDS
 THAT IF A CHILD CARE PROGRAM FOR SCHOOL-AGE CHILDREN IS
 OPERATED IN A PUBLIC SCHOOL, THE PROGRAM NEED NOT
 CONFORM TO STANDARDS FOR PHYSICAL FACILITIES OTHER THAN
 THE STANDARDS ADOPTED BY THE COMMISSIONER OF EDUCATION.
 FAC 65C-22.001
 (6) CHILD CARE STANDARDS. CHILD CARE PROGRAMS MUST
 FOLLOW THE STANDARDS FOUND IN THE ?CHILD CARE FACILITY
 HANDBOOK,? MAY 2019, INCORPORATED HEREIN BY REFERENCE.
 PLEASE SEE EXCERPTS FROM THE ?CHILD CARE FACILITY
 HANDBOOK? ATTACHED TO RETURNED PLAN. THE HANDBOOK MAY
 BE OBTAINED FROM THE DEPARTMENT?S WEBSITE AT
 WWW.MYFLFAMILIES.COM/CHILDCARE OR FROM THE FOLLOWING
 LINK: HTTP://WWW.FLRULES.ORG/GATEWAY/REFERENCE.ASP?NO=R
 EF-11491
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19110517 2017 WILKINS AVE

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-26 Cont ID  
Sent By jesmith Date 2019-11-26 Time 15:01 Rev Time 0.00
Received By jesmith Date 2019-11-26 Time 15:00 Sent To  
Notes
2019-11-26 15:01:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
 IN ORDER TO PROVIDE A PLUMBING REVIEW, A FLOOR PLAN
 SHOWING THE REQUIRED PLUMBING FIXTURES TO COMPLY WITH
 FBC PL CHAPTER 4, INCLUDING TABLE 403.1. PLEASE REFER
 TO WPB FBC 107.3.5.1.3 FOR THE MINIMUM INFORMATION
 REQUIRED IN THE CONSTRUCTION DOCUMENTS.
 ADDITIONALLY, REVIEW THE REQUIREMENTS OF FBC ACC
 CHAPTERS 2, 3 AND 6 AND PROVIDE COMPLIANCE AS REQUIRED
 AS PERTAINS TO THE PLUMBING FIXTURES.
 PLANS SHALL BE PROVIDED AND SUBMITTED IN ACCORDANCE
 WITH WPB FBC 107.2.1 AND 107.3.5.1.3.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 IT MAY BE TO YOUR ADVANTAGE TO HAVE THE CONSTRUCTION
 PLANS DRAWN BY A DESIGN PROFESSIONAL FAMILIAR WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODES AND FLORIDA
 STATUTES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19110517 2017 WILKINS AVE
  
2019-11-20 08:48:09REVIEWER, PLEASE SEE THE EMAIL CORRESPONDENCE FROM MR.
 BROWN. SEE ME IF YOU HAVE QUESTIONS. SAK

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-24 Cont ID  
Sent By llouie Date 2020-01-24 Time 16:32 Rev Time 0.00
Received By llouie Date 2020-01-24 Time 16:32 Sent To  
Notes
2020-01-24 16:31:50- EXISTING HOME DAYCARE FACILITY FOR CHILDREN;
 INCREASING CAPACITY FROM 5 TO 12.
  
 - MUST COMPLY WITH ALL STATE AND COUNTY REGULATIONS
 REGARDING HOME DAYCARE.
  
 - REFERENCE: BTR #0000033099 (MUSTARD SEED LEARNING
 TREE)

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-26 Cont ID  
Sent By llouie Date 2019-11-26 Time   Rev Time  
Received By llouie Date 2019-11-26 Time   Sent To  
Notes
2019-11-26 11:21:45- EXISTING HOME DAYCARE FACILITY FOR CHILDREN;
 INCREASING CAPACITY FROM 5 TO 12.
  
 - MUST COMPLY WITH ALL STATE AND COUNTY REGULATIONS
 REGARDING HOME DAYCARE.
  
 - REFERENCE: BTR #0000033099 (MUSTARD SEED LEARNING
 TREE)