Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-12 Cont ID  
Sent By jbrooks Date 2019-11-12 Time 09:26 Rev Time 0.00
Received By jbrooks Date 2019-11-12 Time 09:25 Sent To HIST
Notes
2019-11-12 09:26:21JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1. FBC B 107.2.1. PROVIDE TWO SETS OF FLOOR
 PLANS/BUILDING FOOT PRINT SHOWING LOCATION OF PROPOSED
 WINDOWS TO BE REPLACED ALONG WITH DIMENSIONS OF EACH
 OPENING; WINDOW TYPE AND ROOM DESIGNATION.
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-11-12 Cont ID  
Sent By aborngra Date 2019-11-12 Time 14:58 Rev Time 0.00
Received By aborngra Date 2019-11-12 Time 14:57 Sent To PC
Notes
2019-11-12 14:58:18THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A FLOOR PLAN.
 2. PROVIDE EXISTING WINDOW SCHEDULE INCLUDING ROUGH
 WINDOW OPENING, WINDOW TYPE, AND LITE PATTERN.
 3. PROVIDE PROPOSED WINDOW SCHEDULE INCLUDING GLASS
 DETAILS, MUNTIN PROFILE, LITE PATTERN, AND SIZE.
 4. FIXED WINDOWS MAY NOT BE AN APPROPRIATE WINDOW
 CONFIGURATION. REPLACEMENT WINDOWS SHOULD MATCH THE
 EXISTING AND/OR ORIGINAL WINDOW TYPE.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL.
 PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED
 WITH.
  
 A. ALL WINDOWS SHALL HAVE CLEAR GLASS OR CLEAR GLASS
 WITH LOW-E COATING. TINTED OR PRIVACY GLASS IS
 PROHIBITED.
 B. ALL WINDOWS SHALL HAVE EXTERNAL OGEE DIMENSIONAL
 MUNTINS.
 C. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING AND THE LOCATION/INSET/DEPTH
 WITHIN THE ORIGINAL FRAME OPENING.
  
 STAFF RECOMMENDS RECYCLING, DONATING, OR STORING ANY
 ORIGINAL WOOD WINDOWS THAT SHALL BE REMOVED AS A PART
 OF THIS PROJECT.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-13 Cont ID  
Sent By jbrooks Date 2019-11-13 Time 10:50 Rev Time  
Received By cpuell Date 2019-11-08 Time 14:24 Sent To  
Notes
2019-11-08 14:24:33SENT TO BLDG<=$5K