Plan Review Details - Permit 19110420
Plan Review Stops For Permit 19110420
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status N Date 2019-12-23 Cont ID  
Sent By jgomez Date 2019-12-23 Time 09:14 Rev Time 0.00
Received By jgomez Date 2019-12-23 Time 09:14 Sent To  
Notes
2019-12-23 09:14:32NEW BUILDING

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2019-11-16 Cont ID  
Sent By jwitmer Date 2019-11-16 Time 05:46 Rev Time 0.00
Received By jwitmer Date 2019-11-15 Time 13:21 Sent To  
Notes
2019-11-16 05:46:31ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-12-30 Cont ID  
Sent By dbattles Date 2019-12-30 Time 12:34 Rev Time 0.00
Received By dbattles Date 2019-12-30 Time 12:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-12-23 Cont ID  
Sent By jgomez Date 2019-12-23 Time 09:30 Rev Time 0.00
Received By jgomez Date 2019-12-23 Time 07:48 Sent To  
Notes
2019-12-23 09:32:47NEED ARCHITECT'S SEAL AND SIGNATURE ON SHEETS A1.1.1
 AND SHEET A2.1.1 AS REQUIRED BY CHAPTER 471 F.S WHEN
 SUBMITTING DOCUMENTS/PLANS FOR PUBLIC RECORDS.
  
 BUILDING REVIEW WILL BE APPROVED WHEN PLANS ARE
 PROPERLY SIGNED AND SEALED.
  
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-16 Cont ID  
Sent By jwitmer Date 2019-11-16 Time 06:42 Rev Time 0.00
Received By jwitmer Date 2019-11-15 Time 13:21 Sent To  
Notes
2019-11-16 06:42:052017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19110420
 ADD: 251 BANYAN BLVD.
 CONT: TYCON MANAGEMENT LLC
 TEL: 561-860-1663
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. NOV. 16/ 2019
 ACTION: DENIED
  
 1) ASBESTOS COMMERCIAL. PLEASE PROVIDE A SIGNED
 ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON LETTERHEAD,
 STATING THAT THE INSTRUCTIONS ON THE WEBSITE OF
 ASBESTOS PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF
 HEALTH PALM BEACH COUNTY WILL BE FOLLOWED AND THAT
 NOTIFICATION WILL BE GIVEN TIMELY. ADDITIONAL
 INFORMATION REGARDING ASBESTOS REQUIREMENTS CAN BE
 FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
 2) SHEET A2.1.1.:
  
 2A) RESTROOM DETAILS 8 & 9 BOTH SHOW THE WATER CLOSET
 GRAB RAILS BEING MEASURED 36 INCHES FROM THE CENTERLINE
 OF THE GRAB BAR ABOVE THE FLOOR LEVEL. PLEASE NOTE IN
 THE 2017 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION
 OF GRAB BARS. GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE, NOT CENTERLINE.
 A 36 INCH MEASUREMENT MEASURED FROM THE CENTERLINE ON A
 1 ? GRAB BAR WOULD PUT THE GRAB BAR 36 ? INCHES ABOVE
 THE FINISH FLOOR BECAUSE OF THE MEASURING FROM CENTER
 LINE AND NOT THE TOP OF THE GRIPPING SURFACE.
  
 2B) DETAIL 9 OF THE SAME PAGE, IT APPEARS EITHER THE
 DETAIL WAS PARTIALLY DELETED OR THE PRINTER RAN OUT OF
 INK IN THE SAME AREA ON BOTH SETS OF PLANS? 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2C) DISCREPANCY IN PLANS. PLEASE REVIEW DETAILS B
 RESTROOM 113 AND DETAIL 8. IN DETAIL B THE WATER CLOSET
 IS DIMENSIONED (BACKWALL) 1 FOOT 6 INCHES AWAY FROM THE
 NEAREST CORNER WHEREAS IN THE DETAIL 8 THE WATER CLOSET
 IS DIMENSIONED AT 1 FOOT 5 INCHES, A DISCREPANCY OF 1
 INCH. THE CODE DOES ALLOW THE ACCESSIBLE WATER CLOSET
 TO BE BETWEEN 16-18 INCHES AWAY FROM THE CORNER WALL
 (2017 ACCESSIBILITY CODE SECTION 604.2 LOCATION).
 PLEASE CORRECT THE DISCREPANCY IN THE PLANS. 107.2.1.2
 ADDITIONAL INFORMATION REQUIRED, DISCREPANCY.
  
 2D) DETAIL A BREAK ROOM CABINETRY. THE FLOOR PLAN DOES
 NOT SHOW WHICH APPROACH WILL BE USED TO GAIN ENTRY TO
 THE BREAK ROOM SINK. THE LOCATION OF THE REQUIRED
 ACCESSIBLE SINK GIVEN ON THIS PLAN APPEARS TO
 CENTERLINE 18 INCHES FROM THE CORNER WALL. SHEET
 A4.1.1. DETAIL 9 A SECTION OF THE SAME CABINETRY SHOWS
 A TOE KICK AND BOTTOM IN THE CABINETRY AND THE PIPES
 NOT COVERED WITH INSULATION. IT APPEARS AS DRAWN
 NEITHER A SIDE APPROACH NOR FRONT APPROACH WILL WORK.
 PLEASE PROVIDE COMPLIANCE WITH THE 2017
 FBC-ACCESSIBILITY CODE SECTIONS:
  
 602.2 CLEAR FLOOR SPACE. UNITS SHALL HAVE A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 POSITIONED FOR A
 FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
  
 2017 FBC-ACCESSIBILITY CODE 606.5 EXPOSED PIPES AND
 SURFACES. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES
 AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO
 PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR
 ABRASIVE SURFACES UNDER LAVATORIES AND SINKS.
  
 MUST ALSO COMPLY WITH 306.2 TOE CLEARANCE AND 306.3
 KNEE CLEARANCE FOR FORWARD APPROACH. 2017
 FBC-ACCESSIBILITY CODE.
  
 IN THE PRESENT LOCATION A SIDE APPROACH WILL NOT WORK,
 THE CENTERLINE OF THE SINK WOULD BE REQUIRED TO BE 2
 FEET FROM THE CORNER WALL FOR THE SIDE APPROACH TO
 WORK.
  
  
 3) SHEET A1.1.1.WINDOW TYPES A & B BOTH QUALIFY AS
 GLAZING IN HAZARDOUS LOCATIONS SEE 2406.4.3 OF THE 2017
 FBC-B. PLEASE IDENTIFY WINDOWS AS SUCH AND THE TYPE OF
 TREATMENT TO BE USED ON THESE WINDOWS.
  
 4) SHEET A1.1.1. PLEASE PROVIDE WHERE THE PROPERTY LINE
 IS LOCATED SINCE THE ENTRY DOORS ARE A OUTSWING DOOR
 AND MAY SWING OUT OVER THE PROPERTY LINE? SHOW
 COMPLIANCE WITH THE 2017 FBC-B SECTION:
  
 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN
 HEIGHT. ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
 ABOVE GRADE AND BELOW 8 FEET (2438 MM) IN HEIGHT SHALL
 BE PROHIBITED EXCEPT AS PROVIDED FOR IN SECTIONS
 3202.2.1 THROUGH 3202.2.3. DOORS AND WINDOWS SHALL NOT
 OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-22 Cont ID  
Sent By jpearson Date 2019-12-22 Time 13:52 Rev Time 0.00
Received By jpearson Date 2019-12-22 Time 13:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-11-21 Cont ID  
Sent By jpearson Date 2019-11-21 Time 08:59 Rev Time 0.00
Received By jpearson Date 2019-11-21 Time 08:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-11-18 Cont ID  
Sent By pleduc Date 2019-11-18 Time   Rev Time 0.00
Received By pleduc Date 2019-11-18 Time 13:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-12-30 Cont ID  
Sent By dbattles Date 2019-12-30 Time 12:35 Rev Time 0.00
Received By dbattles Date 2019-12-30 Time 12:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-23 Cont ID  
Sent By gjohnson Date 2019-12-23 Time 16:52 Rev Time 0.00
Received By gjohnson Date 2019-12-09 Time 15:45 Sent To  
Notes
2019-12-10 15:46:02B12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-27 Cont ID  
Sent By cpuell Date 2019-11-27 Time 13:02 Rev Time 0.00
Received By cpuell Date 2019-11-07 Time 10:16 Sent To  
Notes
2019-11-27 09:42:51TO CAROLINE PUELL.
2019-11-09 10:17:05B17

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-11-16 Cont ID  
Sent By jwitmer Date 2019-11-16 Time 05:47 Rev Time 0.00
Received By jwitmer Date 2019-11-15 Time 13:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-11-15 Cont ID  
Sent By ccole Date 2019-11-15 Time 13:16 Rev Time 0.00
Received By ccole Date 2019-11-15 Time 09:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-12-23 Cont ID  
Sent By gjohnson Date 2019-12-23 Time 16:50 Rev Time 0.00
Received By gjohnson Date 2019-12-23 Time 13:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-19 Cont ID  
Sent By jesmith Date 2019-11-19 Time 14:56 Rev Time 0.00
Received By jesmith Date 2019-11-19 Time 14:55 Sent To  
Notes
2019-11-19 14:56:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 PLEASE NOTE; A REVIEW OF MINIMUM PLUMBING FIXTURE
 REQUIREMENTS AS REQUIRED BY FBC ACC IS PART OF THE
 PLUMBING REVIEW PROCESS BUT IS TYPICALLY ADDRESSED ON
 THE ARCHITECTURAL PLANS. ANY COMMENTS CONCERNING THESE
 REQUIREMENTS MUST BE SATISFACTORILY ADDRESSED PRIOR TO
 A PLUMBING REVIEW APPROVAL.
 1. RE: PLAN SHEET A-2.1.1; DETAIL A. PER WPB FBC
 107.2.1, SHOW CLEAR FLOOR SPACE FOR BREAK ROOM SINK PER
 FBC ACC 305 AND 606.2.
 2. RE: PLAN SHEET A-2.1.1; DETAIL 1. LAVATORIES AND
 SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER
 OF THE RIM OR COUNTER SURFACE 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC ACC
 606.3. PER WPB FBC 107.2.1, CORRECT AS REQUIRED.
 3. RE: PLAN SHEET A-2.1.1; DETAIL 8 AND 9. GRAB BARS
 SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES
 (840 MM) MINIMUM AND 36 INCHES (915 MM) MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE PER FBC ACC 609.4. PER WPB FBC 107.2.1, CORRECT
 AS REQUIRED.
 4. RE: PLAN SHEET A-2.1.1; DETAIL 8. PER FBC ACC 604.2,
 THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM
 TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR
 PARTITION. PER WPB FBC 107.2.1, INDICATE THE SAME.
 5. RE: PLAN SHEET A-2.1.1; DETAIL 8. PER FBC ACC 604.2,
 THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES
 (405 MM) MINIMUM TO 18 INCHES (455 MM) MAXIMUM FROM THE
 SIDE WALL OR PARTITION. PER WPB FBC 107.2.1, INDICATE
 THE SAME.
 6. RE: PLAN SHEET A-2.1.1; DETAIL 8. PER FBC ACC 604.6,
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET. PER WPB FBC 107.2.1, INDICATE THE SAME.
 7. RE: PLAN SHEET A-2.1.1; DETAIL 9. PER FBC ACC 604.2,
 PER FBC ACC 604.7, TOILET PAPER DISPENSERS SHALL COMPLY
 WITH 309.4 AND SHALL BE 7 INCHES (180 MM) MINIMUM AND 9
 INCHES (230 MM) MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET
 OF THE DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM
 AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR
 AND SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS
 SHALL NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT
 DOES NOT ALLOW CONTINUOUS PAPER FLOW. PER WPB FBC
 107.2.1, INDICATE THE SAME.
 8. RE: PLAN SHEET A-2.1.1; DETAIL 9. PER FBC ACC 604.2,
 PER FBC ACC 604.5.1, THE SIDE WALL GRAB BAR SHALL BE 42
 INCHES (1065 MM) LONG MINIMUM, LOCATED 12 INCHES (305
 MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES
 (1370 MM) MINIMUM FROM THE REAR WALL. PER WPB FBC
 107.2.1, INDICATE THE SAME.
 9. RE: PLAN SHEET A-2.1.1; DETAIL 10. PER WPB FBC
 107.2.1, TO COMPLY WITH FBC ACC 306.3.1, PROVIDE
 MINIMUM 27 INCHES ABOVE THE FLOOR FOR KNEE CLEARANCE.
 10. RE: PLAN SHEET P2.01; CHRONOMITE CM-15L/120
 TANKLESS WATER HEATER IS DESIGNED TO DELIVER .5 GPM,
 WHICH IS ADEQUATE FOR THE LAVATORY BUT APPEARS NOT TO
 PROPERLY ACCOMMODATE THE SINK. PER WPB FBC 107.2.1,
 PLEASE REVISIT AND CONFIRM OR MAKE CORRECTIONS AS
 REQUIRED. PROVIDE SPECIFICATIONS FOR EACH WATER HEATER.
 11. RE: PLAN SHEET P2.01; TEMPERED WATER SHALL BE
 DELIVERED FROM LAVATORIES AND GROUP WASH FIXTURES
 LOCATED IN PUBLIC TOILET FACILITIES PROVIDED FOR
 CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER SHALL
 BE DELIVERED THROUGH AN APPROVED WATER-TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA
 B125.3 PER FBC PL 416.5. PER WPB FBC 107.2.1, INDICATE
 THE SAME.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19110420 251 BANYAN BLVD
  

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-27 Cont ID  
Sent By aaponte Date 2019-11-27 Time 09:42 Rev Time 0.00
Received By aaponte Date 2019-11-27 Time 09:42 Sent To  
Notes
***NONE***