Plan Review Details - Permit 19110260
Plan Review Stops For Permit 19110260
Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2019-12-30 Cont ID  
Sent By rrossano Date 2019-12-30 Time   Rev Time  
Received By   Date 2019-12-30 Time   Sent To I
Notes
2019-12-30 07:06:02REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL E19010018.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2020-04-02 Time   Rev Time 0.00
Received By lmarchan Date 2020-03-25 Time 16:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-03-17 Cont ID  
Sent By shill Date 2020-03-17 Time 15:34 Rev Time 0.00
Received By shill Date 2020-03-16 Time 14:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-05 Cont ID  
Sent By lmarchan Date 2020-03-05 Time 11:36 Rev Time 0.00
Received By lmarchan Date 2020-02-26 Time 11:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-02-10 Cont ID  
Sent By gjohnson Date 2020-02-10 Time 14:35 Rev Time 0.00
Received By gjohnson Date 2020-02-04 Time 13:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-30 Cont ID  
Sent By shill Date 2019-12-30 Time 07:17 Rev Time 0.00
Received By shill Date 2019-11-13 Time 09:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2020-04-02 Cont ID  
Sent By jesmith Date 2020-04-02 Time 11:28 Rev Time 0.00
Received By jpearson Date 2020-03-27 Time 09:47 Sent To  
Notes
2020-04-02 11:27:59PASSED BY JERRY SMITH WORKING REMOTE, ENTERED BY JOHN
 PEARSON.

Review Stop P PLUMBING
Rev No 4 Status F Date 2020-03-17 Cont ID  
Sent By shill Date 2020-03-17 Time 15:33 Rev Time 0.00
Received By shill Date 2020-03-17 Time 11:19 Sent To  
Notes
2020-03-17 15:34:06CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 96= STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 19110260 2970 N MILITARY TRAIL
  
 PLUMBING COMMEMTS: DENIED
  
 I.REGARDING MASTER PERMIT 19020380 REVIEW #2 DATED
 7/25/19
 THIS ISSUE HAS NEVER BEEN ADDRESSED. PLUMBING RESPONSE
 NOTE 11 ONLY ADDRESSES THE ROOF HYDRANT AND THE
 SUBMITTED NIDEL #50 BACKFLOW PREVENTER INDICATED ON
 PLAN C8.1 AND C8 DOES NOT PROVIDE PROTECTION OF THE
 POTABLE WATER SUPPLY. THE Y34 YARD HYDRANT HAS A STOP
 AND WASTE VALVE AT THE BASE OF THE RISER WHICH WILL
 ALLOW GROUND WATER AND CONTAMINATES TO ENTER THE
 SYSTEM. PROVIDE A DEDICATED REDUCED PRESSURE BACKFLOW
 PREVENTER IN THE SUPPLY LINE UPSTREAM OF THE YARD
 HYDRANTS. SHOW LOCATION, PROVIDE SPECIFICATION AND A
 DETAIL. REFER TO ALL NOTES LISTED IN 2ND REQUEST NOTED
 BELOW AND COMPLY.
 ***2ND REQUEST***
 1. SEE MARK UPS ON PLAN SHEET C8 AND SD1; THESE ITEMS
 MUST BE SATISFACTORILY ADDRESSED BEFORE A PLUMBING
 PERMIT WILL BE ISSUED.
 A. C8 AND SD1/DETAIL 12: SD1/DETAIL 12 CREATES A
 HAZARDOUS CONDITION. IN ACCORDANCE WITH FBC 608.7,
 608.8.1 AND 608.8.2, PROVIDE A BACKFLOW PREVENTER FOR
 THE DEDICATED SUPPLY, SIGNAGE AT THE HYDRANTS AND
 EXPOSED PIPING SHALL BE COLOR PURPLE AND LABELED.
 1) FBC PL 608.7 VALVES AND OUTLETS PROHIBITED BELOW
 GRADE. FREEZEPROOF YARD HYDRANTS THAT DRAIN THE RISER
 INTO THE GROUND SHALL BE PERMITTED TO BE INSTALLED,
 PROVIDED THAT THE POTABLE WATER SUPPLY TO SUCH HYDRANTS
 IS PROTECTED UPSTREAM OF THE HYDRANTS IN ACCORDANCE
 WITH SECTION 608 AND THE HYDRANTS ARE PERMANENTLY
 IDENTIFIED AS NON-POTABLE OUTLETS BY APPROVED SIGNAGE
 THAT READS AS FOLLOWS: ?CAUTION, NON-POTABLE WATER. DO
 NOT DRINK.?
 A.FBC PL608.8.1 SIGNAGE REQUIRED.
 NONPOTABLE WATER OUTLETS, SUCH AS HOSE CONNECTIONS,
 OPEN ENDED PIPES AND FAUCETS, SHALL BE IDENTIFIED WITH
 SIGNAGE THAT READS AS FOLLOWS: ?NON-POTABLE WATER IS
 UTILIZED FOR [APPLICATION NAME]. CAUTION: NONPOTABLE
 WATER ? DO NOT DRINK.? THE WORDS SHALL BE LEGIBLY AND
 INDELIBLY PRINTED ON A TAG OR SIGN CONSTRUCTED OF
 CORROSION-RESISTANT WATERPROOF MATERIAL OR SHALL BE
 INDELIBLY PRINTED ON THE FIXTURE. THE LETTERS OF THE
 WORDS SHALL BE NOT LESS THAN 0.5 INCH (12.7 MM) IN
 HEIGHT AND IN COLORS IN CONTRAST TO THE BACKGROUND ON
 WHICH THEY ARE APPLIED. IN ADDITION TO THE REQUIRED
 WORDAGE, THE PICTOGRAPH SHOWN IN FBC PL FIGURE 608.8.1
 SHALL APPEAR ON THE REQUIRED SIGNAGE.
 B. FBC PL 608.8.2 DISTRIBUTION PIPE LABELING AND
 MARKING.
 C. NON-POTABLE DISTRIBUTION PIPING SHALL BE PURPLE IN
 COLOR AND SHALL BE EMBOSSED, OR INTEGRALLY STAMPED OR
 MARKED, WITH THE WORDS: ?CAUTION: NONPOTABLE WATER ? DO
 NOT DRINK? OR THE PIPING SHALL BE INSTALLED WITH A
 PURPLE IDENTIFICATION TAPE OR WRAP. PIPE IDENTIFICATION
 SHALL INCLUDE THE CONTENTS OF THE PIPING SYSTEM AND AN
 ARROW INDICATING THE DIRECTION OF FLOW. HAZARDOUS
 PIPING SYSTEMS SHALL ALSO CONTAIN INFORMATION
 ADDRESSING THE NATURE OF THE HAZARD. PIPE
 IDENTIFICATION SHALL BE REPEATED AT INTERVALS NOT
 EXCEEDING 25 FEET (7620 MM) AND AT EACH POINT WHERE THE
 PIPING PASSES THROUGH A WALL, FLOOR OR ROOF. LETTERING
 SHALL BE READILY OBSERVABLE WITHIN THE ROOM OR SPACE
 WHERE THE PIPING IS LOCATED.
 B.ADDITIONAL COMMENT: PER WPB FBC 1097.2.1, ADD SPEC
 AND DETAIL FOR BACKFLOW PREVENTER AND SHOW LOCATION ON
 THE PLAN
 II. REGARDING THE GREASE INTERCEPTOR, THERE IS NO
 EXCEPTION TAKEN. RESUBMIT AS IS WITH NEXT RESUBMITTAL.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
  
  
 19110260 2970 N MILITARY TRAIL
 MASTER PERMIT 19020380 2970 N MILITARY TRAIL
 RACETRAC #1367 JAY BOSWELL
 [email protected] OFFICE: 954-426-5144
 CELL: 954-295-1764
  
 GDP GROUP MARK S. SALOPEK, LLC 330-802-6255
  
  
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2020-03-05 Cont ID  
Sent By tklarge Date 2020-03-05 Time 11:12 Rev Time 0.00
Received By tklarge Date 2020-03-05 Time 05:13 Sent To  
Notes
2020-03-05 11:12:111) THERE ARE TWO DIFFERENT GREAE INTERCEPTOR DETAILS ON
 SHT. C8.6. WHICH ONE IS BEING INSTALLED? CROSS OUT THE
 INTERCEPTOR WHICH WILL NOT BE USED. WPB AMEND. TO FBC
 SEC. 107.2.1.
 2) THERE IS A THIRD DETAIL FOR A GREASE INTERCEPTOR
 THAT HAS BEEN UPLOADED THAT IS FROM US CONCRETE
 PRODUCTS. IF THIS UNIT IS NOT BEING INSTALLED, DELETE
 IT FROM THIS SUBMITTAL PACKAGE.WPB AMEND. TO FBC SEC.
 107.2.1.
 AT THIS POINT, IT IS CONFUSING AS TO WHICH INTERCEPTOR
 IS BEING INSTALLED.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-02-10 Cont ID  
Sent By gjohnson Date 2020-02-10 Time 14:28 Rev Time 0.00
Received By gjohnson Date 2020-02-10 Time 14:35 Sent To  
Notes
2020-02-10 14:34:562ND REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. 2ND REQUEST PLEASE PROVIDE SIZING CALCULATION FOR
 THE GREASE INTERCEPTORS THE RESPONSE LETTER STATED THEY
 WERE ON SHEET P001 THAT SHEET HAS NOT BEEN UPLOADED.
 PER FBC PL 1003.2
  
 2. PROVIDE PIPING DETAIL OF GREASE INTERCEPTORS BEING
 USED SHALL COMPLY WITH FAC 64E-6. PER WPB AMEND TO FBC
 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-27 Cont ID  
Sent By shill Date 2019-12-27 Time 07:35 Rev Time 0.00
Received By shill Date 2019-12-26 Time 09:15 Sent To  
Notes
2019-12-27 07:35:41PLUMBING 1ST REVIEW**DENIED**19110260
  
 1) THE SIZE, TYPE AND LOCATION OF EACH INTERCEPTOR AND
 OF EACH SEPARATOR SHALL BE APPROVED BY THE PLUMBING
 OFFICIAL FBC-PLB 1003.2.PROVIDE THE CALCULATIONS ON HOW
 YOU SIZED THIS INTERCEPTOR PER RULE 64E-6, FLORIDA
 ADMINISTRATIVE CODE OR BY PDI G101. FBC-PLB 1003.3.4
  
 2) ON SHT. C8, C8.1 AND C8.6 YOU REFER TO PALM BEACH
 COUNTY DETAIL FOR THE INTERCEPTOR. IS THE UTILITIES
 PROVIDER PALM BEACH COUNTY OR CITY OF WEST PALM BEACH?
 PLEASE CLARIFY FBC 107.2.1
  
 3) PROVIDE MAKE AND MODEL OF INTERCEPTOR ALONG WITH
 COMPLETE MANUFACTURES INSTALLATION MANUAL. FBC-PLB
 1003.3.4, FBC 107.2.1
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-04-02 Cont ID  
Sent By jpearson Date 2020-04-02 Time 11:29 Rev Time 0.00
Received By jpearson Date 2020-04-02 Time 11:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2020-03-17 Cont ID  
Sent By shill Date 2020-03-17 Time 13:11 Rev Time 0.00
Received By shill Date 2020-03-17 Time 13:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-02-27 Cont ID  
Sent By shill Date 2020-02-27 Time 17:14 Rev Time 0.00
Received By shill Date 2020-02-27 Time 17:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-02-26 Cont ID  
Sent By medwards Date 2020-02-26 Time 15:50 Rev Time 0.00
Received By medwards Date 2020-02-26 Time   Sent To  
Notes
2020-02-26 15:50:022ND CYCLE SIGNATURES APPROVED.
 NEXT CYCLE DIGITAL SIGNATURES WILL NEED TO BE REVIEWED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-12-27 Cont ID  
Sent By shill Date 2019-12-27 Time 07:36 Rev Time 0.00
Received By shill Date 2019-12-27 Time 07:36 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved