Plan Review Details - Permit 19110216
| Plan Review Stops For Permit 19110216 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-15 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-15 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-11-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-07 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-07 |
Time |
12:19 |
Sent To |
HIST |
|
| Notes |
| 2019-11-07 12:20:18 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1.FBC R 301 FAC9N-3 FOR FLORIDA STATE PRODUCT APPROVAL, | | | PROVIDE THE FOLLOWING FOR EACH PRODUCT: COVER SHEET | | | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE | | | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL | | | INFORMATION ABOUT THE PRODUCT) EVALUATION REPORT. THESE | | | ITEMS MISSING FROM SUBMITTED PRODUCT APPROVALS FOR | | | PROPOSED DOORS. PROVIDE TWO SETS. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-11-15 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-11-15 |
Time |
12:13 |
Sent To |
PC |
|
| Notes |
| 2019-11-15 12:13:10 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITIONS: | | | | | | 1. THE CASEMENT WINDOWS (WINDOWS #3, 2, 21, 20, 19, 18, | | | 17) SHALL HAVE A 6 LITE PATTERN WITH TWO HORIZONTAL | | | MUNTINS AND ONE CENTER VERTICAL MUNTIN. | | | 2. THE WOOD BEAM BETWEEN WINDOW #20 AND #19 SHALL BE | | | RETAINED OR REPLACED WITH AN ALUMINUM MULLION OF THE | | | SAME DIMENSIONS AND LOCATION. | | | 3. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME OPENING. ALL WINDOWS SHALL MATCH THE | | | INSET/DEPTH/LOCATION OF THE ORIGINAL WINDOWS WITHIN THE | | | WINDOW OPENING. | | | 4. ALL WINDOWS SHALL USE THE SEMI-CONTOURED (EXTERIOR | | | ONLY) PROFILE MUNTIN. | | | | | | STAFF RECOMMENDS RECYCLING, DONATING, OR STORING ANY | | | WOOD WINDOW SASHES THAT SHALL BE REMOVED AS A PART OF | | | THIS PROJECT TO PRESERVE AN ORIGINAL HISTORIC RESOURCE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-11-08 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-11-08 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-11-08 |
Time |
13:59 |
Sent To |
PC |
|
| Notes |
| 2019-11-08 14:01:01 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITIONS: | | | | | | 1. THE CASEMENT WINDOWS (WINDOWS #3, 2, 21, 20, 19, 18, | | | 17) SHALL HAVE A 6 LITE PATTERN WITH TWO HORIZONTAL | | | MUNTINS AND ONE CENTER VERTICAL MUNTIN. | | | 2. THE WOOD BEAM BETWEEN WINDOW #20 AND #19 SHALL BE | | | RETAINED OR REPLACED WITH AN ALUMINUM MULLION OF THE | | | SAME DIMENSIONS AND LOCATION. | | | 3. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL | | | WINDOW FRAME OPENING. ALL WINDOWS SHALL MATCH THE | | | INSET/DEPTH/LOCATION OF THE ORIGINAL WINDOWS WITHIN THE | | | WINDOW OPENING. | | | 4. ALL WINDOWS SHALL USE THE SEMI-CONTOURED (EXTERIOR | | | ONLY) PROFILE MUNTIN. | | | | | | STAFF RECOMMENDS RECYCLING, DONATING, OR STORING ANY | | | WOOD WINDOW SASHES THAT SHALL BE REMOVED AS A PART OF | | | THIS PROJECT TO PRESERVE AN ORIGINAL HISTORIC RESOURCE. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES | | | PLANNING DIVISION | | | [email protected] | OFFICE: 561.822.1428 | TTY: | | | 800.955.8771 | | | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, | | | FL 33402 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-11-13 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2019-11-14 16:01:57 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-11-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-09 |
Time |
09:30 |
Rev Time |
|
| Received By |
cpuell |
Date |
2019-11-05 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2019-11-05 10:50:21 | SENT TO MISC 1 BLDG |
|
|
|
Account Summary | Usage Policy | Privacy Policy