Plan Review Details - Permit 19110041
Plan Review Stops For Permit 19110041
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2020-03-09 Cont ID  
Sent By shill Date 2020-03-09 Time 18:18 Rev Time 0.00
Received By shill Date 2020-03-09 Time 18:18 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2019-12-13 Cont ID  
Sent By shill Date 2019-12-13 Time 16:09 Rev Time 0.00
Received By shill Date 2019-12-13 Time 16:09 Sent To  
Notes
2019-12-13 16:09:31PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2019-11-12 Cont ID  
Sent By shill Date 2019-11-12 Time 07:34 Rev Time 0.00
Received By shill Date 2019-11-12 Time 07:34 Sent To  
Notes
2019-11-12 07:35:37PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND ?ASBESTOS? IN THE SUBJECT LINE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-07-01 Cont ID  
Sent By rmcdouga Date 2020-07-01 Time 08:47 Rev Time 0.00
Received By rmcdouga Date 2020-07-01 Time 07:36 Sent To  
Notes
2020-07-01 08:47:58APPROVED WITH PROVISO
 FBC 110.3.9 SPECIAL INSPECTOR DOCUMENTS FOR STRUCTURAL
 WORK TO BE PROVIDED UNDER LANDLORD'S PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2020-04-08 Cont ID  
Sent By rmcdouga Date 2020-04-08 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2020-04-07 Time 18:10 Sent To  
Notes
2020-04-08 14:29:57PLAN
 REVIEW COMMENTS
  
 4TH REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
  
 1) FBC 110.3.9 SPECIAL INSPECTOR DOCUMENTS FOR
 STRUCTURAL WORK TO BE PROVIDED UNDER LANDLORD'S PERMIT.
 THERE WERE NO SPECIAL INSPECTOR DOCUMENTS SUBMITTED FOR
 THE STRUCTURAL WORK WITH THE LANDLORD'S PERMIT
 #20030637.
  
 2) THE INDEX SHEET G100 DOES NOT HAVE A DIGITAL
 SIGNATURE. FS 471
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2020-03-18 Cont ID  
Sent By rmcdouga Date 2020-03-18 Time 10:30 Rev Time 0.00
Received By rmcdouga Date 2020-03-16 Time 18:34 Sent To  
Notes
2020-03-18 09:31:08PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
  
 1) THE PLANS FOR THIS PROJECT HAS NOTES INDICATING THAT
 SOME OF THE WORK SHOWN IS THE RESPONSIBILITY OF THE
 OWNER UNDER A SEPARATE PERMIT. THIS RAISES SOME
 CONCERNS THAT WILL NEED TO BE ADDRESSED PRIOR TO
 APPROVAL OF THIS PERMIT.
 A) WILL THE SAME CONTRACTOR BE USED FOR BOTH THE
 LANDLORD'S AND THE TENANT'S PROPOSED SCOPE OF WORK?
 B) IF DIFFERENT CONTRACTORS ARE USED, WILL THE SCOPE OF
 WORK FOR THE LANDLORD'S CONTRACTOR BE COMPLETED AND
 FINAL-ED BEFORE THE TENANT'S CONTRACTOR STARTS THEIR
 BUILDOUT?
 B) IF THE WORK TWO DIFFERENT CONTRACTORS WILL BE
 CONCURRENT, A LETTER OF UNDERSTANDING FROM THE LANDLORD
 WILL BE REQUIRED. THE LETTER NEEDS TO CLEARLY INDICATE
 THE SCOPE OF WORK TO BE PERFORMED BY EACH CONTRACTOR
 AND WHO WILL BE RESPONSIBLE FOR RESOLVING ANY DISPUTES
 THAT MAY ARISE. THE CITY/ BUILDING DEPARTMENT WILL NOT
 BE RESPONSIBLE FOR RESOLVING CONTRACT DISPUTES. THE
 LETTER SHALL BE SIGNED BY THE LANDLORD AND EACH OF THE
 CONTRACTORS.
  
 2) THE PLANS FOR THE PROPOSED WORK TO BE PERFORMED BY
 THE LANDLORD'S CONTRACTOR NEEDS TO BE SUBMITTED FOR
 COMPARISON WITH THE TENANTS PLANS, BEFORE THIS PERMIT
 IS ISSUED. FBC 107.2.1.2
  
 3) FBC 107.3.4.1 DEFERRED SUBMITTAL. FBC 107.3.4 -
 PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER
 FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES FOR THE SKYLIGHT.
  
 4) FBC 107.3.4.1 DEFERRED SUBMITTAL. SUBMIT SHOP
 DRAWINGS FOR THE STAIRS FROM THE DELEGATE ENGINEER THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD. FAC 61G15-30.003 ENGINEERING DOCUMENT
 CLASSIFICATION. FL 61G-15-30.006 (3) THE DELEGATED
 ENGINEER SHALL FORWARD THE DELEGATED ENGINEERING
 DOCUMENTS TO THE ENGINEER OF RECORD FOR REVIEW.
  
 5) FBC 110.3.9 SPECIAL INSPECTOR DOCUMENTS FOR
 STRUCTURAL WORK TO BE PROVIDED UNDER LANDLORD'S PERMIT.
  
 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-12-13 Cont ID  
Sent By rmcdouga Date 2019-12-13 Time 17:06 Rev Time 0.00
Received By rmcdouga Date 2019-12-13 Time 17:00 Sent To  
Notes
2019-12-13 17:06:11PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING - THE COMMENTS FROM THE FIRST REVIEW
 WERE NOT ADDRESSED.
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS ARE REQUIRED TO BE APPROVED BY CITY PLACE
 MANAGEMENT. THE CITY PLACE APPROVAL STAMP IS REQUIRED
 TO BE ON THE DRAWINGS.
  
 2) EXTERIOR SIGNS WILL REQUIRE A SEPARATE PERMIT. FBC
 105.1
  
 3) A SEPARATE ROOFING REPAIR PERMIT WILL BE REQUIRED TO
 PATCH THE ROOF AT THE SKYLIGHT AND RELOCATED EQUIPMENT.
 FBC 105.1
  
 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE SKYLIGHT.
  
 5) PLEASE REVISE THE CODE INFORMATION ON THE
 COVERSHEET. THE 2017 CHAPTER 1 AMENDMENTS SHOULD BE
 REFERENCED AND NOT THE 2010.
  
 6) THE OCCUPANT LOAD FACTOR FOR THE GROUND FLOOR SALES
 AREA OF 30 GROSS IS INCORRECT. THE OCCUPANT LOAD FACTOR
 FOR MERCANTILE IS 60 GROSS PER FBC 2017 TABLE 1004.1.2.
 THIS WAS CHANGED FROM THE 2014 FBC.
  
 7) THE ACCESSIBLE FITTING ROOM BENCH HEIGHT IS
 SPECIFIED AS 1'-6" AFF ON SHEET A450 AND 1'-7" ON SHEET
 A526. PLEASE COORDINATE. FBC 107.2.1
  
 8) ON SHEET A101, THERE IS A ROOM LABELED "VISUAL" WITH
 ONE HOUR FIRE RATED WALLS AND A 60 MINUTE FIRE RATED
 DOOR. PLEASE EXPLAIN THE USE OF THIS ROOM AND IDENTIFY
 THE TYPE AND QUANTITIES OF ANY HAZARDOUS MATERIALS THAT
 MAY BE PRESENT. FBC 107.2.1 AND 107.2.1.2
  
 9) THE LIFE SAFETY PLANS ARE NOT COMPLETE. THE LIFE
 SAFETY PLANS NEED TO SHOW THE FOLLOWING:
 A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1
 B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1
 C) EXIT SEPARATION DISTANCE FBC 1015.2.1
 D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3
 E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3
 F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC
 1008.1.1
 G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND
 MEANS OF EGRESS FACTOR FBC1005.3.2
 H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5
  
 10) WELDED OR BOLTED CONNECTIONS
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2017 FBC-B 2204.1 WELDING
 2017 FBC-B 2204.2 BOLTING.
  
 11) SUBMIT SHOP DRAWINGS FOR THE STAIRS FROM THE
 DELEGATE ENGINEER THAT HAVE BEEN REVIEWED AND APPROVED
 BY THE DESIGNER OF RECORD. FAC 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 12) SUBMIT SHORING PLANS FOR THE OPENING FOR THE NEW
 STAIRS THAT HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD. FAC 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 13) THE STRUCTURAL GENERAL NOTES ON SHEET S000 REQUIRE
 A REGISTERED ENGINEER OR TEST AGENCY WITH EXPERIENCED
 TECHNICIANS UNDER THE DIRECT SUPERVISION OF A
 REGISTERED ENGINEER TO PERFORM THE DUTIES OF THE
 SPECIAL INSPECTOR FOR THE STRUCTURAL INSPECTIONS. 2017
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER
 INSPECTIONS SERVICES. RESIDENT INSPECTOR. THE BUILDING
 OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE
 INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT
 REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION
 SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS
 SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A
 CERTIFICATE CALLED FOR BY ANY PROVISION OF THE
 TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS
 UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A
 RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F ?C) IN EXCESS OF 3000
 POUNDS PER SQUARE INCH
 4. FOR PILE DRIVING
 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE
 FOOT
 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION
 RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES
 NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT. FOR
 THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME'
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME'. PLEASE CONTACT ME WITH AN EMAIL
 ADDRESS AND I WILL BE HAPPY TO SEND YOU A COPY OF THE
 OCTOBER 2018 GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT
 INSPECTORS.
  
 14) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-20 Cont ID  
Sent By rmcdouga Date 2019-11-20 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2019-11-19 Time 07:17 Sent To  
Notes
2019-11-20 11:34:58PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS ARE REQUIRED TO BE APPROVED BY CITY PLACE
 MANAGEMENT. THE CITY PLACE APPROVAL STAMP IS REQUIRED
 TO BE ON THE DRAWINGS.
  
 2) EXTERIOR SIGNS WILL REQUIRE A SEPARATE PERMIT. FBC
 105.1
  
 3) A SEPARATE ROOFING REPAIR PERMIT WILL BE REQUIRED TO
 PATCH THE ROOF AT THE SKYLIGHT AND RELOCATED EQUIPMENT.
 FBC 105.1
  
 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE SKYLIGHT.
  
 5) PLEASE REVISE THE CODE INFORMATION ON THE
 COVERSHEET. THE 2017 CHAPTER 1 AMENDMENTS SHOULD BE
 REFERENCED AND NOT THE 2010.
  
 6) THE OCCUPANT LOAD FACTOR FOR THE GROUND FLOOR SALES
 AREA OF 30 GROSS IS INCORRECT. THE OCCUPANT LOAD FACTOR
 FOR MERCANTILE IS 60 GROSS PER FBC 2017 TABLE 1004.1.2.
 THIS WAS CHANGED FROM THE 2014 FBC.
  
 7) THE ACCESSIBLE FITTING ROOM BENCH HEIGHT IS
 SPECIFIED AS 1'-6" AFF ON SHEET A450 AND 1'-7" ON SHEET
 A526. PLEASE COORDINATE. FBC 107.2.1
  
 8) ON SHEET A101, THERE IS A ROOM LABELED "VISUAL" WITH
 ONE HOUR FIRE RATED WALLS AND A 60 MINUTE FIRE RATED
 DOOR. PLEASE EXPLAIN THE USE OF THIS ROOM AND IDENTIFY
 THE TYPE AND QUANTITIES OF ANY HAZARDOUS MATERIALS THAT
 MAY BE PRESENT. FBC 107.2.1 AND 107.2.1.2
  
 9) THE LIFE SAFETY PLANS ARE NOT COMPLETE. THE LIFE
 SAFETY PLANS NEED TO SHOW THE FOLLOWING:
 A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1
 B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1
 C) EXIT SEPARATION DISTANCE FBC 1015.2.1
 D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3
 E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3
 F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC
 1008.1.1
 G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND
 MEANS OF EGRESS FACTOR FBC1005.3.2
 H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5
  
 10) WELDED OR BOLTED CONNECTIONS
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2017 FBC-B 2204.1 WELDING
 2017 FBC-B 2204.2 BOLTING.
  
 11) SUBMIT SHOP DRAWINGS FOR THE STAIRS FROM THE
 DELEGATE ENGINEER THAT HAVE BEEN REVIEWED AND APPROVED
 BY THE DESIGNER OF RECORD. FAC 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 12) SUBMIT SHORING PLANS FOR THE OPENING FOR THE NEW
 STAIRS THAT HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD. FAC 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 13) THE STRUCTURAL GENERAL NOTES ON SHEET S000 REQUIRE
 A REGISTERED ENGINEER OR TEST AGENCY WITH EXPERIENCED
 TECHNICIANS UNDER THE DIRECT SUPERVISION OF A
 REGISTERED ENGINEER TO PERFORM THE DUTIES OF THE
 SPECIAL INSPECTOR FOR THE STRUCTURAL INSPECTIONS. 2017
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER
 INSPECTIONS SERVICES. RESIDENT INSPECTOR. THE BUILDING
 OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE
 INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT
 REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION
 SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS
 SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A
 CERTIFICATE CALLED FOR BY ANY PROVISION OF THE
 TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS
 UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A
 RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F ?C) IN EXCESS OF 3000
 POUNDS PER SQUARE INCH
 4. FOR PILE DRIVING
 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE
 FOOT
 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION
 RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES
 NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT. FOR
 THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME'
 MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED
 HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL
 REVIEW THE RESUME'. PLEASE CONTACT ME WITH AN EMAIL
 ADDRESS AND I WILL BE HAPPY TO SEND YOU A COPY OF THE
 OCTOBER 2018 GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT
 INSPECTORS.
  
 14) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-06-30 Cont ID  
Sent By jleahy Date 2020-06-30 Time 09:32 Rev Time 0.00
Received By jleahy Date 2020-06-25 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-03-17 Cont ID  
Sent By jleahy Date 2020-03-17 Time 12:48 Rev Time 0.00
Received By jleahy Date 2020-03-09 Time 12:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-11-18 Cont ID  
Sent By jleahy Date 2019-11-18 Time 08:26 Rev Time 0.00
Received By jleahy Date 2019-11-18 Time 08:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2020-06-19 Cont ID  
Sent By pleduc Date 2020-06-19 Time   Rev Time 0.00
Received By pleduc Date 2020-06-19 Time 10:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2020-03-25 Cont ID  
Sent By pleduc Date 2020-03-25 Time   Rev Time 0.00
Received By pleduc Date 2020-03-25 Time 09:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2020-03-10 Cont ID  
Sent By pleduc Date 2020-03-10 Time   Rev Time 0.00
Received By pleduc Date 2020-03-10 Time 12:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-11-27 Cont ID  
Sent By pleduc Date 2019-11-27 Time   Rev Time 0.00
Received By pleduc Date 2019-11-27 Time 10:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-11-20 Cont ID  
Sent By pleduc Date 2019-11-20 Time   Rev Time 0.00
Received By pleduc Date 2019-11-18 Time 10:17 Sent To  
Notes
2019-11-20 11:14:42THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET G 100 - THERE ARE NO INDICATIONS OF REVIEW OR
 COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH
 INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101.
  
 THE BELOW LIST ARE THE MOST COMMON REFERENCED CODES:
  
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2013 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2013 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2013 EDITION.
 FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 10, 2013 EDITION.
 ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION.
  
 PLEASE REVIEW AND ENSURE COMPLIANCE AS THESE ARE WHAT
 THE PROJECT WILL BE INSPECTED WITH.
  
  
  
 2) SHEET FA 100 - THE PROPOSED FIRE ALARM SHALL BE
 INSTALLED UNDER SEPARATE SUBMITTED PERMIT AND SHOP
 DRAWINGS BY CERTIFIED FA CONTRACTOR.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2020-07-06 Cont ID  
Sent By shill Date 2020-07-06 Time 13:41 Rev Time 0.00
Received By shill Date 2020-06-18 Time 10:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-04-15 Cont ID  
Sent By lmarchan Date 2020-04-15 Time 10:14 Rev Time 0.00
Received By lmarchan Date 2020-03-24 Time 13:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-03-23 Cont ID  
Sent By shill Date 2020-03-23 Time 10:27 Rev Time 0.00
Received By shill Date 2020-03-06 Time 08:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-17 Cont ID  
Sent By shill Date 2019-12-17 Time 19:23 Rev Time 0.00
Received By shill Date 2019-11-25 Time 10:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-20 Cont ID  
Sent By rmcdouga Date 2019-11-20 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2019-11-05 Time 13:20 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2020-03-09 Cont ID  
Sent By shill Date 2020-03-09 Time 18:17 Rev Time 0.00
Received By shill Date 2020-03-09 Time 18:17 Sent To  
Notes
2020-03-09 18:17:44SPOKE WITH MICHELLE BONNANI ON ANOTHER PROJECT; CHANGE
 OF OCCUPANCY FROM ASSEMBLY TO MERCANTILE AT CITY PLACE
 DOES NOT REQUIRE IMPACT FEES
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-11-19 Cont ID  
Sent By rmcdouga Date 2019-11-19 Time 10:51 Rev Time 0.00
Received By rmcdouga Date 2019-11-19 Time 07:17 Sent To  
Notes
2019-11-19 11:05:26THE SECOND FLOOR IS A CHANGE OF OCCUPANCY FROM AN
 ASSEMBLY ( BAR/RESTAURANT) TO A MERCANTILE. THE PLANS
 WILL NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEES. PLANS WILL BE REVIEWED BY THE PBC IMPACT
 FEE OFFICE DIGITALLY VIA PROJECTDOX UPON NOTIFICATION
 BY THIS OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE
 NEAREST FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT
 FEE OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE
 MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT
 AND NAME THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2020-06-24 Cont ID  
Sent By pvalenti Date 2020-06-24 Time 14:44 Rev Time 0.00
Received By pvalenti Date 2020-06-24 Time 14:39 Sent To  
Notes
2020-06-24 14:43:59PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
  
 MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 SEPARATE PERMIT BY LANDLORD REQUIRED FOR THE FAN COIL
 UNITS.
 CCOLE? 3/16/20

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-03-16 Cont ID  
Sent By ccole Date 2020-03-16 Time 10:26 Rev Time 0.00
Received By ccole Date 2020-03-16 Time 07:55 Sent To  
Notes
2020-03-16 10:27:54MECHANICAL PROVISO:
  
 SEPARATE PERMIT BY LANDLORD REQUIRED FOR THE FAN COIL
 UNITS.
 CCOLE- 3/16/20
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-12-06 Cont ID  
Sent By ccole Date 2019-12-06 Time 11:20 Rev Time 0.00
Received By ccole Date 2019-12-06 Time 09:16 Sent To  
Notes
2019-12-06 11:24:272ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19110041
 12/6/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 IT APPEARS THAT NO CORRECTIONS OR CHANGES TO THE PLAN
 HAVE BEEN MADE BASED ON THE FIRST REVIEW COMMENTS
 PRINTED BELOW- PLEASE COMPLY.
  
 1) THE PLANS INDICATE THE NEW FCU'S UNDER A SEPARATE
 PERMIT, HOWEVER CURRENTLY THERE IS NO PERMIT APPLIED
 FOR, OR ISSUED FOR THE UNITS. PLEASE PROVIDE MORE
 INFORMATION, AND NOTE THAT SIZING CALCULATIONS MAY BE
 REQUIRED UNDER THIS PERMIT AND AN INCREASE IN VALUE FOR
 THE COST OF THE UNITS- SECTION 107.2.1 & 109.3 WPB.
  
 2) SHEET M101: EXHAUST VENTILATION AT A RATE OF 0.25
 CFMS PER SF. IS REQUIRED FOR THE FITTING ROOMS PER
 TABLE 403.3.1.1 FBC M. PLEASE REVISE THE PLANS
 ACCORDINGLY.
  
 3) M101: THE CORRIDOR (HALLWAY) CANNOT BE USED TO
 RETURN AIR FROM THE ROOMS TO THE MECHANICAL ROOM-
 SECTION 601.2 FBC M.
  
 4) M101: CLARIFY THE NEED FOR THE EXHAUST FANS EF-1 & 2
 IN THE VISUAL AND OFFICE ROOMS. PROVIDE FAN SIZING
 CALCULATIONS AND THE SEQUENCES OF OPERATION- SECTION
 107.2.1 WPB.
  
 5) M300: THE ROOF MOUNTED FAN DETAIL IS INCOMPLETE.
 INDICATE HOW THE CURB WILL BE ATACHED TO THE STRUCTURE,
 AND THE FAN ATTACHED TO THE CURB. WHICH TYPE OF ANCHORS
 AND FASTENERS WILL BE USED- SECTION 301.15 FBC M.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-11-18 Cont ID  
Sent By ccole Date 2019-11-18 Time 16:12 Rev Time 0.00
Received By ccole Date 2019-11-18 Time 13:41 Sent To  
Notes
2019-11-18 16:48:241ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19110041
 11/18/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PLANS INDICATE THE NEW FCU'S UNDER A SEPARATE
 PERMIT, HOWEVER CURRENTLY THERE IS NO PERMIT APPLIED
 FOR, OR ISSUED FOR THE UNITS. PLEASE PROVIDE MORE
 INFORMATION, AND NOTE THAT SIZING CALCULATIONS MAY BE
 REQUIRED UNDER THIS PERMIT AND AN INCREASE IN VALUE FOR
 THE COST OF THE UNITS- SECTION 107.2.1 & 109.3 WPB.
  
 2) SHEET M101: EXHAUST VENTILATION AT A RATE OF 0.25
 CFMS PER SF. IS REQUIRED FOR THE FITTING ROOMS PER
 TABLE 403.3.1.1 FBC M. PLEASE REVISE THE PLANS
 ACCORDINGLY.
  
 3) M101: THE CORRIDOR (HALLWAY) CANNOT BE USED TO
 RETURN AIR FROM THE ROOMS TO THE MECHANICAL ROOM-
 SECTION 601.2 FBC M.
  
 4) M101: CLARIFY THE NEED FOR THE EXHAUST FANS EF-1 & 2
 IN THE VISUAL AND OFFICE ROOMS. PROVIDE FAN SIZING
 CALCULATIONS AND THE SEQUENCES OF OPERATION- SECTION
 107.2.1 WPB.
  
 5) M300: THE ROOF MOUNTED FAN DETAIL IS INCOMPLETE.
 INDICATE HOW THE CURB WILL BE ATACHED TO THE STRUCTURE,
 AND THE FAN ATTACHED TO THE CURB. WHICH TYPE OF ANCHORS
 AND FASTENERS WILL BE USED- SECTION 301.15 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-03-23 Cont ID  
Sent By shill Date 2020-03-23 Time 10:26 Rev Time 0.00
Received By shill Date 2020-03-23 Time 08:15 Sent To  
Notes
2020-03-23 10:26:51OK PER JAMES BAKER, PE
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-12-17 Cont ID  
Sent By shill Date 2019-12-17 Time 19:22 Rev Time 0.00
Received By shill Date 2019-12-16 Time 17:07 Sent To  
Notes
2019-12-17 19:23:052ND PLUMBING REVIEW**DENIED** COMMENTS FROM 1ST REVIEW
 HAVE NOT BEEN ADDRESSED. FAILURE TO FULLY COMPLY ON THE
 NEXT SUBMITTAL COULD LEAD TO A 4X PLAN REVIEW FEE.
 553.80 (B)?WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS
 IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
 1) SHOW ELEVATOR SUMP PUMP AND DISCHARGE CHARGE PIPING.
 FBC 107.3.5
 2) SHT. G100 LIST THE AMENDMENTS YEAR AS 2010. PLEASE
 CORRECT AND LIST 2017. FBC 107.2.1
 3) SHOW BREAK ROOM SINK AS HAVING CLEAR FLOOR SPACE
 MATCHING ALL SHEETS THAT SHOW TOILET ROOM CLEAR FLOOR
 SPACE. FBC 107.3.5
 4) SHOW SEPARATE CLEAR FLOOR SPACE OUTSIDE THE ARC OF
 THE DOOR SWING AS REQUIRED IN FBC-ACC 603.2.3
 5) SHT. A-555 SHOW THE REAR GRAB BAR AS MOUNTING 12?
 FROM THE CENTER OF TOILET OVER TOWARDS THE SIDE WALL.
 FBC-ACC 604.5.2
 6) SHOW HOT WATER RETURN LINE AS IT APPEARS THE
 DISTANCE EXCEEDS THE MAX ALLOWED FROM THE SOURCE OF HOT
 WATER. FBC-ENERGY C404.5.1, FBC-PLB 607.2
 7) CALL OUT MIN ALLOWED PIPE INSULATIONS IS 1? WALL.
 SHT. P400 CALLS OUT ALL PIPING 2? AND UNDER MIN 1?
 WALL. SEE TABLE C403.2.10 FBC 107.2.1
 8) SHT.P-200 DETAIL (D) CALLS OUT WATER HEATER IS POINT
 OF USE BUT SHOW TANK TYPE. PLEASE CLARIFY. FBC-107.2
 9) PROVIDE WATER HEATER INSTALLATION MANUAL SHOW IT
 COMPLIES WITH MIN ENERGY REQUIREMENTS. FBC-ENERGY
 C404.2
 TIM HUNT
 PLUMBING PLAN EXAMINER
 CITY OF WEST PALM BEACH ( CGA SOLUTIONS)
 [email protected]
 561-248-2703
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-12 Cont ID  
Sent By shill Date 2019-11-12 Time 07:18 Rev Time 0.00
Received By shill Date 2019-11-07 Time 08:02 Sent To  
Notes
2019-11-12 07:18:541ST PLUMBING REVIEW**DENIED**
  
 1) SHOW ELEVATOR SUMP PUMP AND DISCHARGE CHARGE PIPING.
 FBC 107.3.5
 2) SHT. G100 LIST THE AMENDMENTS YEAR AS 2010. PLEASE
 CORRECT AND LIST 2017. FBC 107.2.1
 3) SHOW BREAK ROOM SINK AS HAVING CLEAR FLOOR SPACE
 MATCHING ALL SHEETS THAT SHOW TOILET ROOM CLEAR FLOOR
 SPACE. FBC 107.3.5
 4) SHOW SEPARATE CLEAR FLOOR SPACE OUTSIDE THE ARC OF
 THE DOOR SWING AS REQUIRED IN FBC-ACC 603.2.3
 5) SHT. A-555 SHOW THE REAR GRAB BAR AS MOUNTING 12?
 FROM THE CENTER OF TOILET OVER TOWARDS THE SIDE WALL.
 FBC-ACC 604.5.2
 6) SHOW HOT WATER RETURN LINE AS IT APPEARS THE
 DISTANCE EXCEEDS THE MAX ALLOWED FROM THE SOURCE OF HOT
 WATER. FBC-ENERGY C404.5.1, FBC-PLB 607.2
 7) CALL OUT MIN ALLOWED PIPE INSULATIONS IS 1? WALL.
 FBC 107.2.1
 8) SHT.P-200 DETAIL (D) CALLS OUT WATER HEATER IS POINT
 OF USE BUT SHOW TANK TYPE. PLEASE CLARIFY. FBC-107.2
 9) PROVIDE WATER HEATER INSTALLATION MANUAL SHOW IT
 COMPLIES WITH MIN ENERGY REQUIREMENTS. FBC-ENERGY
 C404.2
 TIM HUNT
 PLUMBING PLAN EXAMINER
 CITY OF WEST PALM BEACH ( CGA SOLUTIONS)
 [email protected]
 561-248-2703
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2020-07-01 Cont ID  
Sent By rmcdouga Date 2020-07-01 Time 08:40 Rev Time 0.00
Received By rmcdouga Date 2020-07-01 Time 08:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2020-04-08 Cont ID  
Sent By rmcdouga Date 2020-04-08 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2020-04-08 Time 14:30 Sent To  
Notes
2020-04-08 14:31:21SHEET G100 VERSION 3 HAS NOT BEEN DIGITALLY SEALED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-03-21 Cont ID  
Sent By shill Date 2020-03-21 Time 12:00 Rev Time 0.00
Received By shill Date 2020-03-21 Time 12:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-12-13 Cont ID  
Sent By shill Date 2019-12-13 Time 16:11 Rev Time 0.00
Received By shill Date 2019-12-13 Time 16:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-11-12 Cont ID  
Sent By shill Date 2019-11-12 Time 07:34 Rev Time 0.00
Received By shill Date 2019-11-12 Time 07:34 Sent To  
Notes
2019-11-12 07:34:38ADVISED K.HERBERT, PE VIA EMAIL THAT SELF CERTIFYING
 SIGNATURE NOT PERMITTED (MECHANICAL); OBTAIN 3RD PARTY
 SIGNATURE FOR FUTURE PROJECTS, THIS COMMENT DOES NOT
 AFFECT THIS PERMIT
  
  
  
  
  

Review Stop Z ZONING
Rev No 5 Status P Date 2020-06-30 Cont ID  
Sent By eschneid Date 2020-06-30 Time 13:20 Rev Time 1.00
Received By eschneid Date 2020-06-30 Time 11:29 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2020-04-15 Cont ID  
Sent By eschneid Date 2020-04-15 Time 10:00 Rev Time 0.50
Received By eschneid Date 2020-04-14 Time 16:24 Sent To  
Notes
2020-04-15 10:00:55FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) REPEAT COMMENT: ALL EXTERIOR SIGNAGE NEEDS TO BE
 REMOVED FROM SHEETS A200 AND A201. NOTE: EXTERIOR
 SIGNAGE REQUIRES A SEPARATE PERMIT AND IS NOT REVIEWED
 AS PART OF THE INTERIOR BUILD OUT PERMIT. THESE SHEETS
 HAVE NOT BEEN REMOVED AS STATED IN THE COMMENT
 RESPONSE.
  
 2) UPDATED COMMENT: THE 2ND LEVEL FLOOR PLAN INDICATES
 THAT THE EXTERIOR WALLS AT THE CORNER OF THE BAY, WHERE
 THE FITTING ROOMS ARE PROPOSED) ARE EXISTING SOLID
 WALLS (EXISTING STUCCO SURFACE FACADE ON SHEETS A200
 AND A201). THIS IS NOT ACCURATE. CONTRARY TO THE
 COMMENT RESPONSE, SHEETS A200 AND A201 HAVE NOT BEEN
 REMOVED. WHILE THE LANDLORD HAS SUBMITTED PERMIT
 20030637 FOR EXTERIOR WORK, ZONING STAFF HAS NOT
 APPROVED THE PERMIT. ONE ISSUE IS THE PROPOSED BLOCKING
 IN THE GLAZING AT THE CORNER OF THIS IMPORTANT SPACE.
 THIS CORNER NEEDS TO REMAIN WITH GLAZING. IF YOU MUST
 LOCATE THE FITTING ROOMS IN THIS LOCATION, WHICH SEEMS
 THAT IT WOULD BE BETTER SERVED TO HAVE VIEW INTO THE
 STORE, THEN SET THE FITTING ROOM BACK SO THAT THAT
 THERE CAN BE MERCHANDISE DISPLAYED BETWEEN STOREFRONT
 GLAZING AND THE REAR OF THE FITTING ROOMS. LIFESTYLE
 IMAGERY CAN THEN BE INSTALLED ON THE BACK OF THE
 FITTING ROOMS WALLS.
  
 3) NEW COMMENT: THE RESPONSE COMMENTS STATE THAT THERE
 IS NO FACADE/EXTERIOR STOREFRONT WORK ASSOCIATED WITH
 THIS INTERIOR BUILD OUT PERMIT. THE SECOND FLOOR
 EXTERIOR INCLUDED AS A BASE FOR THIS PERMIT DOES NOT
 MATCH WHAT IS SHOWN ON THE LANDLORD EXTERIOR WORK
 PERMIT. THIS INCLUDES THE ENTRY DOOR LOCATION (NORTH
 VS. WEST FACADE) AND THE PROPOSED SOLID WALL INFILL
 (NOT APPROVED BY ZONING - SEE COMMENT 2). UNLESS YOU
 ARE GOING TO CHANGE WHAT THE LANDLORD IS INSTALLING,
 ALL THE PLANS NEED TO SHOW THE EXTERIOR MATCHING WHAT
 THE FINAL APPROVED PERMIT FOR THE LANDLORD WORK SHOWS.
 IF YOU ARE CHANGING WHAT IS APPROVED FOR THE LANDLORD,
 THEN YOU WILL NEED TO INCLUDE THE DETAILS FOR THE NEW
 EXTERIOR DEMOLITION AND CONSTRUCTION WITH THIS PERMIT.
  
 4) UPDATED REPEAT COMMENT: SHEETS M101 AND M201
 SPECIFICALLY CALL OUT THE INSTALLATION OF NEW EXHAUST
 FANS TO BE INSTALLED ON THE ROOF WITH THIS PERMIT. THE
 LANDLORD IS NOT INSTALLING ROOFTOP EQUIPMENT AS PART OF
 PERMIT 20030637 OR ANY OTHER PERMIT. IN ACCORDANCE WITH
 THE CITYPLACE DRI, PLEASE PROVIDE VERIFICATION THAT THE
 NEW EXHAUST FANS (NEW ROOFTOP MECHANICAL EQUIPMENT),
 ARE SCREENED FROM PUBLIC VIEW THROUGH ANY COMBINATION
 OF LANDSCAPING, WALLS AND EQUIPMENT LOCATION.
 VERIFICATION CAN BE PROVIDED BY PLANS OR OTHER EVIDENCE
 THAT THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL BE
 SCREENED FROM PUBLIC VIEW.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status F Date 2020-03-13 Cont ID  
Sent By eschneid Date 2020-03-13 Time 11:40 Rev Time 0.25
Received By eschneid Date 2020-03-13 Time 10:57 Sent To  
Notes
2020-03-13 11:41:05FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) ALL SIGNAGE NEEDS TO BE REMOVED FROM SHEETS A200 AND
 A201.
  
 2) REPEAT COMMENT: THE 2ND LEVEL FLOOR PLAN INDICATES
 THAT THE EXTERIOR WALLS AT THE CORNER OF THE BAY, WHERE
 THE FITTING ROOMS ARE PROPOSED) ARE EXISTING SOLID
 WALLS (EXISTING STUCCO SURFACE FACADE ON SHEETS A200
 AND A201). THIS IS NOT ACCURATE. THE OPENINGS HAVE A
 KNEE WALL WITH STOREFRONT GLAZING. THE EXISTING
 OPENINGS MAY NOT BE FILLED IN, BLACKED OUT OR OTHERWISE
 HAVE CONSTRUCTION TO OBSTRUCT THE VIEW INTO THE STORE.
 ---- THE STOREFRONT ELEVATIONS ON SHEETS A200 AND A201
 CONTINUE TO SHOW INACCURATE CONDITIONS. THERE IS NO
 PERMIT TO CLOSE IN THE EXISTING STOREFRONT ON WHERE THE
 CHANGING ROOMS ARE PROPOSED. YOU MAY NOT SHOW
 INACCURATE PLANS AND THEN SAY THAT IT IS NOT PART OF
 YOUR SCOPE OF WORK.
  
 3) REPEAT COMMENT: IT APPEARS THAT THERE IS NEW
 EQUIPMENT BEING INSTALLED ON THE ROOF. IN ACCORDANCE
 WITH THE CITYPLACE DRI, PLEASE PROVIDE VERIFICATION
 THAT ALL ROOFTOP MECHANICAL EQUIPMENT, INCLUDING BUT
 NOT LIMITED TO SUCH ITEMS AS PUBLIC AND PRIVATE UTILITY
 SERVICE CONNECTIONS; HEATING, VENTILATING, AND AIR
 CONDITIONING SYSTEMS; COMMUNICATIONS DEVICES; AND
 RELATED EQUIPMENT, SHALL BE SCREENED FROM PUBLIC VIEW
 THROUGH ANY COMBINATION OF LANDSCAPING, WALLS AND
 EQUIPMENT LOCATION. PLEASE PROVIDE PLANS OR OTHER
 EVIDENCE THAT THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL
 BE SCREENED FROM PUBLIC VIEW. ---- THE RESPONSE LETTER
 MENTIONS SEPARATE PERMITS FOR THE ROOFTOP EQUIPMENT,
 YET STAFF HAS FOUND NO EVIDENCE OF A SEPARATE PERMIT;
 THEREFORE, YOU NEED TO PROVIDE THE DRAWINGS TO VERIFY
 THAT THE EQUIPMENT MEETS THE SCREENING REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-12-09 Cont ID  
Sent By eschneid Date 2019-12-09 Time 14:01 Rev Time 0.25
Received By eschneid Date 2019-12-09 Time 11:52 Sent To  
Notes
2019-12-09 14:03:04FAILED
  
 PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) REPEAT COMMENT: THE PLANS ARE EITHER REQUIRED TO
 HAVE THE CITYPLACE RETAIL, LLC, APPROVAL STAMP ON THEM,
 OR YOU MUST PROVIDE A SEPARATE LETTER FROM CITYPLACE
 RETAIL, LLC, APPROVING THE SPECIFIC PLANS THAT YOU HAVE
 SUBMITTED.
  
 2) REPEAT COMMENT: SIGNAGE REQUIRES SEPARATE PERMIT
 WITH PLANS. NOTE: THE SIGNS DO NOT APPEAR TO CONFORM TO
 THE ROSEMARY SQUARE MASTER SIGN PLAN.
  
 3) REPEAT COMMENT: THE 2ND LEVEL FLOOR PLAN INDICATE
 THAT THE EXTERIOR WALLS AT THE CORNER OF THE BAY, WHERE
 THE FITTING ROOMS ARE PROPOSED) ARE EXISTING SOLID
 WALLS (EXISTING STUCCO SURFACE FACADE ON SHEETS A200
 AND A201). THIS IS NOT ACCURATE. THE OPENINGS HAVE A
 KNEE WALL WITH STOREFRONT GLAZING. THE EXISTING
 OPENINGS MAY NOT BE FILLED IN, BLACKED OUT OR OTHERWISE
 HAVE CONSTRUCTION TO OBSTRUCT THE VIEW INTO THE STORE.
  
 4) REPEAT COMMENT: IT APPEARS THAT THERE IS NEW
 EQUIPMENT BEING INSTALLED ON THE ROOF. IN ACCORDANCE
 WITH THE CITYPLACE DRI, PLEASE PROVIDE VERIFICATION
 THAT ALL ROOFTOP MECHANICAL EQUIPMENT, INCLUDING BUT
 NOT LIMITED TO SUCH ITEMS AS PUBLIC AND PRIVATE UTILITY
 SERVICE CONNECTIONS; HEATING, VENTILATING, AND AIR
 CONDITIONING SYSTEMS; COMMUNICATIONS DEVICES; AND
 RELATED EQUIPMENT, SHALL BE SCREENED FROM PUBLIC VIEW
 THROUGH ANY COMBINATION OF LANDSCAPING, WALLS AND
 EQUIPMENT LOCATION. PLEASE PROVIDE PLANS OR OTHER
 EVIDENCE THAT THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL
 BE SCREENED FROM PUBLIC VIEW.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-11-18 Cont ID  
Sent By eschneid Date 2019-11-18 Time 14:34 Rev Time 0.75
Received By eschneid Date 2019-11-08 Time 09:26 Sent To  
Notes
2019-11-18 14:37:33FAILED
  
 1) THE PLANS ARE EITHER REQUIRED TO HAVE THE CITYPLACE
 RETAIL, LLC, APPROVAL STAMP ON THEM, OR YOU MUST
 PROVIDE A SEPARATE LETTER FROM CITYPLACE RETAIL, LLC,
 APPROVING THE SPECIFIC PLANS THAT YOU HAVE SUBMITTED.
  
 2) SIGNAGE REQUIRES SEPARATE PERMIT WITH PLANS. NOTE:
 THE SIGNS DO NOT APPEAR TO CONFORM TO THE ROSEMARY
 SQUARE MASTER SIGN PLAN.
  
 3) THE 2ND LEVEL FLOOR PLAN INDICATE THAT THE EXTERIOR
 WALLS AT THE CORNER OF THE BAY, WHERE THE FITTING ROOMS
 ARE PROPOSED) ARE EXISTING SOLID WALLS (EXISTING STUCCO
 SURFACE FA?ADE ON SHEETS A200 AND A201). THIS IS NOT
 ACCURATE. THE OPENINGS HAVE A KNEE WALL WITH STOREFRONT
 GLAZING. THE EXISTING OPENINGS MAY NOT BE FILLED IN,
 BLACKED OUT OR OTHERWISE HAVE CONSTRUCTION TO OBSTRUCT
 THE VIEW INTO THE STORE.
  
 4) IT APPEARS THAT THERE IS NEW EQUIPMENT BEING
 INSTALLED ON THE ROOF. IN ACCORDANCE WITH THE CITYPLACE
 DRI, PLEASE PROVIDE VERIFICATION THAT ALL ROOFTOP
 MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO SUCH
 ITEMS AS PUBLIC AND PRIVATE UTILITY SERVICE
 CONNECTIONS; HEATING, VENTILATING, AND AIR CONDITIONING
 SYSTEMS; COMMUNICATIONS DEVICES; AND RELATED EQUIPMENT,
 SHALL BE SCREENED FROM PUBLIC VIEW THROUGH ANY
 COMBINATION OF LANDSCAPING, WALLS AND EQUIPMENT
 LOCATION. PLEASE PROVIDE PLANS OR OTHER EVIDENCE THAT
 THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL BE SCREENED
 FROM PUBLIC VIEW.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  