Plan Review Details - Permit 19110025
| Plan Review Stops For Permit 19110025 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-02-13 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-02-13 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-01-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-01-30 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-01-30 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2020-01-30 10:16:12 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1. FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN | | | HEADING ?ANCHOR SPACING? FOR OPENINGS 2,3,4,8,9,10 AND | | | 12; PROVIDE INFORMATION FROM PAGE FROM PAGES 12-15 OF | | | FL389-R9. EXAMPLE: MAXIMUM DESIGN PRESSURE 60, MAXIMUM | | | SHUTTER SPAN 9?-0?; POURED CONCRETE; WALL HEADER | | | MOUNTING TYPE A; 3? MIN. EDGE DISTANCE; ANCHOR TYPE | | | TAPCON MAXIMUM ANCHOR SPACING IS 10?. MAXIMUM DESIGN | | | PRESSURE 60, MAXIMUM SHUTTER SPAN 9?-0?; POURED | | | CONCRETE; WALL HEADER MOUNTING TYPE D; 3? MIN. EDGE | | | DISTANCE; ANCHOR TYPE TAPCON MAXIMUM ANCHOR SPACING IS | | | 4?. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-26 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-26 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2019-11-26 08:48:15 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1.FBC B 107.2.1. PLEASE CORRECT THE FOLLOWING; ON THE | | | SCHEDULE FOR INSTALLATION OF PROTECTIVE DEVICES OR | | | ASSEMBLIES: COLUMN HEADING ?ANCHOR SPACING?; PROVIDE | | | INFORMATION FROM PAGES 12 THROUGH 15 OF PRODUCT | | | APPROVAL FL389.2, FOR OPENINGS 2-10 AND 12-20 AS PER | | | SHUTTER MOUNTING CONNECTION TYPE; ASD NEGATIVE PRESSURE | | | RATING; MAXIMUM SHUTTER SPAN; ANCHOR TYPE AND | | | SUBSTRATE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-11-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-07 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-07 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2019-11-07 09:05:27 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | | 805-6724 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION | | | OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL | | | INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL | | | SPREADSHEET): INFORMATION MUST CORRESPOND WITH | | | SUBMITTED PRODUCT APPROVALS. | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS?PAGE=2 | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-02-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-02-13 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-02-10 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2020-02-11 14:01:39 | RESUB ROUTED TO JBROOKS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-01-30 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-01-27 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2020-01-28 13:34:48 | RESUB ROUTED TO CMONTELLO/JBROOK'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-26 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-20 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2019-11-21 11:34:49 | RESUB ROUTED TO JBROOKS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-11-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2019-11-07 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2019-11-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2019-11-01 10:48:04 | SENT TO MISC 1 BLDG |
|
|
|