Plan Review Details - Permit 19101604
| Plan Review Stops For Permit 19101604 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2019-11-06 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-11-06 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2019-11-06 |
Time |
|
Sent To |
M |
|
| Notes |
| 2019-11-06 07:57:02 | REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-11-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-11-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-11-05 |
Time |
11:26 |
Sent To |
ENG |
|
| Notes |
| 2019-11-05 11:31:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE BACKFLOW PREVENTOR IS INDICATED CLOSE TO THE | | | BUILDING WITH NO DIMENSIONS PROVIDED. | | | | | | PER NFPA 24 | | | | | | 6.2.11 ALL CONNECTIONS TO PRIVATE FIRE SERVICE MAINS | | | FOR FIRE | | | PROTECTION SYSTEMS SHALL BE ARRANGED IN ACCORDANCE WITH | | | ONE | | | OF THE FOLLOWING SO THAT THEY CAN BE ISOLATED | | | | | | | | | (4)*A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | | VALVE NOT | | | LESS THAN 40 FT (12 M) FROM THE BUILDING | | | (A) FOR BUILDINGS LESS THAN 40 FT (12 M) IN HEIGHT, A | | | BACKFLOW | | | PREVENTER WITH AT LEAST ONE INDICATING VALVE SHALL | | | BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FT (12 M) | | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | | THE WALL FACING THE BACKFLOW PREVENTER. | | | | | | PLEASE INSTALL THE BACKFLOW AS FAR AWAY FROM THE | | | BUILDING AS POSSIBLE AS REQUIRED FOR THE MINIMUM | | | PROPERTY LINE DISTANCES. | | | | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-11-15 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-10-30 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2019-10-31 13:22:28 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-11-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-11-15 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-11-15 |
Time |
09:17 |
Sent To |
I |
|
| Notes |
|
|
|