Plan Review Details - Permit 19101600
| Plan Review Stops For Permit 19101600 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-11-01 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-11-01 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-11-01 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2019-11-01 10:46:13 | 1. PROVIDE A K-TYPE PORTABLE FIRE EXTINGUISHER AND | | | ASSOCIATED SIGNAGE IN KITCHEN AREA. | | | | | | 2. KITCHEN HOOD SUPPRESSION SYSTEM SHALL BE TIED INTO | | | THE BUILDING FIRE ALARM SYSTEM TO INITIATE A GENERAL | | | FIRE ALARM CONDITION. | | | | | | 3. DEEP FAT FRYERS SHALL BE EQUIPPED WITH A SEPARATE | | | HIGH-LIMIT CONTROL IN ADDITION TO THE ADJUSTABLE | | | THERMOSTAT TO SHUT OFF FUEL OR ENERGY WHEN THE FAT | | | TEMPERATURE REACHES 475F DEGREES AT 1-INCH BELOW THE | | | SURFACE. | | | | | | 4. PROVIDE AN 8" TALL STEEL BAFFLE OR PROVIDE 16" OF | | | SPACE BETWEEN THE DEEP FAT FRYER AND SURFACE FLAMES OF | | | THE ADJACENT EQUIPMENT. | | | | | | 5. WHERE APPLICABLE, ANY AND ALL WORK ON THE FIRE ALARM | | | SYSTEM SHALL BE DONE BY A FIRE ALARM CONTRACTOR. A | | | SEPARATE SHOP DRAWING COMPLIANT WITH NFPA 72 IS | | | REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE | | | FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | 6. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY | | | WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS. | | | EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS | | | SHALL BE SUBMITTED SEPARATELY FOR APPROVAL. | | | | | | 7. PLEASE PROVIDE MANUFACTURER'S SPECIFICATION SHEETS | | | FOR ALL EQUIPMENT TO BE EXCHANGED (I.E. NOZZLES, | | | FUSIBLE LINKS, CYLINDERS, ETC.) | | | | | | S. THOMAS | | | 561-804-4728 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-30 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2019-10-31 13:41:27 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-11-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-11-05 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-05 |
Time |
08:04 |
Sent To |
I |
|
| Notes |
| 2019-11-05 08:07:47 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19101600 | | | 11/5/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A BRIEF SCOPE OF WORK OUTLINE ON THE | | | PLAN THAT CLARIFIES AND ITEMIZES ALL COMPONENTS OF THE | | | SYSTEM THAT WILL BE UNDERGOING REPAIR- SECTION 107.2.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |