Plan Review Details - Permit 19101435
Plan Review Stops For Permit 19101435
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-17 Cont ID  
Sent By cthroop Date 2019-12-17 Time 11:31 Rev Time 0.00
Received By cthroop Date 2019-12-17 Time 11:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-11-22 Cont ID  
Sent By cthroop Date 2019-11-22 Time 13:55 Rev Time 0.00
Received By cthroop Date 2019-11-20 Time 11:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-12-17 Cont ID  
Sent By cthroop Date 2019-12-17 Time 11:30 Rev Time 0.00
Received By cthroop Date 2019-12-17 Time 11:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-11-19 Cont ID  
Sent By jpearson Date 2019-11-19 Time 12:18 Rev Time 0.00
Received By jpearson Date 2019-11-19 Time 10:52 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2019-11-08 Cont ID  
Sent By fmittner Date 2019-11-08 Time 11:16 Rev Time 0.00
Received By fmittner Date 2019-11-08 Time 11:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-12-17 Cont ID  
Sent By cthroop Date 2019-12-17 Time 11:26 Rev Time 0.00
Received By cthroop Date 2019-12-17 Time 11:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-22 Cont ID  
Sent By cthroop Date 2019-11-22 Time 13:55 Rev Time 0.00
Received By cthroop Date 2019-10-28 Time 14:27 Sent To  
Notes
2019-11-12 13:10:55THERE IS AN EXISTING A/C SYSTEM IN PLACE IN WHAT
 APPEARS TO BE AN UN-CONDITIONED SPACE PER PAPA
 DOCUMENTS AND FILE NET RECORDS
2019-10-29 14:27:58R04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2019-12-30 Cont ID  
Sent By cthroop Date 2019-12-30 Time 13:20 Rev Time 0.00
Received By cthroop Date 2019-12-30 Time 13:20 Sent To  
Notes
2019-12-30 13:21:27NO FEES DUE. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-11-22 Cont ID  
Sent By cthroop Date 2019-11-22 Time 13:54 Rev Time 0.00
Received By cthroop Date 2019-11-21 Time 13:53 Sent To  
Notes
2019-11-22 13:54:57PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-12-17 Cont ID  
Sent By cthroop Date 2019-12-17 Time 11:26 Rev Time 0.00
Received By cthroop Date 2019-12-17 Time 11:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-12 Cont ID  
Sent By jesmith Date 2019-11-12 Time 13:12 Rev Time 0.00
Received By jesmith Date 2019-11-12 Time 08:46 Sent To  
Notes
2019-11-12 13:12:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLUMBING COMMENTS: DENIED
 1. PROVISO: AT THE PLUMBING INSPECTOR'S DISCRETION,
 SHOW THAT ANY EXISTING PLUMBING INFRASTRUCTURE,
 INCLUSIVE OF PIPING, PLUMBING FIXTURES AND APPLIANCES
 SHOWN ON THE DEMOLITION PLAN, IS CODE COMPLIANT. THIS
 MAY REQUIRE PROVIDING DOCUMENTATION OF, OPENING OF
 WALLS AND FLOORS, PRESSURE TESTS, VIDEO CAM OF BURIED
 SANITARY, ETC., AS DETERMINED BY THE PLUMBING
 INSPECTOR. PLEASE CALL TIM LARGE AT 561-805-6692 FOR
 ADDITIONAL INFORMATION OR CLARIFICATION.
 2. SEE REDLINED COMMENTS ON PLAN:
 A. SANITARY RISER DIAGRAM; PROVIDE VENT FOR WATER
 CLOSET AND SHOWER COMPLYING WITH FBC RES P3108
 B. SHOWER COMPARTMENTS LESS THAN 30" WIDE (FINISH
 DIMENSION) SHALL BE A MINIMUM 25 INCHES WIDE AND HAVE
 MINIMUM 1300 SQUARE INCHES CROSS SECTIONAL PER FBC RES
 PO2708.1.
 C. SHOWER COMPARTMENT ACCESS/EGRESS SHALL HAVE A CLEAR,
 UNOBSTRUCTED WIDTH OF NOT LESS THAN 22" PER FBC RES
 P2708.1.1.
 D. SEE SHOWER DETAIL; LINER SHALL TURN UP A MINIMUM OF
 2 INCHES FROM THE TOP DOWN TO THE THRESHOLD AT THE CURB
 SHALL BE MINIMUM OF 2 INCHES
 E. SEE SHOWER DETAIL; PROVIDE SHOWER DRAIN IN
 ACCORDANCE WITH FBC RES P2709.4.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19101435 727 KANUGA DR
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-12-31 Cont ID  
Sent By fmittner Date 2019-12-31 Time 08:51 Rev Time 0.00
Received By fmittner Date 2019-12-31 Time 08:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-11-08 Cont ID  
Sent By fmittner Date 2019-11-08 Time 11:17 Rev Time 0.00
Received By fmittner Date 2019-11-08 Time 11:17 Sent To  
Notes
2019-11-08 12:19:07NO SECOND UNIT PERMIT ON SITE. LOT DOES NOT MEET ZONING
 MINIMUMS.
  
 QUESTIONS, CONTACT: FRIEDERIKE MITTNER, CITY HISTORIC
 PRESERVATION PLANNER AT (561) 822-1457


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved