Plan Review Details - Permit 19101417
Plan Review Stops For Permit 19101417
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-11-20 Cont ID  
Sent By jgomez Date 2019-10-28 Time 18:49 Rev Time 0.00
Received By jgomez Date 2019-10-28 Time 18:32 Sent To  
Notes
2019-10-28 18:50:05REVISED 11/19/19
  
  
 BUILDING REVIEW APPROVED WITH PROVISO.
 (NOTE: PROVIDE REVISION BEFORE WINDOW BUCK INSPECTION):
  
 1- REVISE EGRESS WINDOW NOTE ON SHEET A-01. THE NOTE
 REFERENCES A 1994 CODE SECTION. CURRENT CODE IS 2017.
 REVISE NOTE TO SHOW COMPLIANCE WITH EITHER SEC. 702.5
 FBC-EXISTING BUILDING OR SEC. R310.2 FBC-RESIDENTIAL
 (2017).
  
 SEC. 702.5 FBC-EXISTING BUILDING REQUIRES SAME TYPE OF
 MANUFACTURER'S LARGEST SIZE WINDOW THAT WILL FIT
 WITHING THE EXISTING ROUGH OPENING OR OTHER STYLE THAT
 PROVIDES EQUAL OR GREATER WINDOW OPENING AREA THAN THE
 EXISTING WINDOW.
  
 2- BASED ON ENGINEER'S LETTER SUBMITTED, THERE IS ROOF
 RAFTERS REPAIR WORK. IF THESE SCOPE OF WORK IS PART OF
 THIS PERMIT, THEN PROVIDE REVISED PLANS SHOWING
 COMPLETE DETAILS/SPECIFICATIONS AND AREA OF WORK. OR
 PROVIDE COMPLETE INFORMATION ON SEPARATE PERMIT.
 NOTE: SPECS DESCRIBED ON THE LETTER ARE FOR MASONRY
 CONSTRUCTION. THIS IS A WOOD FRAMED HOUSE. PROVIDE
 INFORMATION THAT MATCHES HOUSE CONSTRUCTION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-11-12 Cont ID  
Sent By jpearson Date 2019-11-12 Time 13:28 Rev Time 0.00
Received By jpearson Date 2019-11-12 Time 13:28 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-11-13 Cont ID  
Sent By fmittner Date 2019-11-13 Time 13:45 Rev Time 0.00
Received By fmittner Date 2019-11-13 Time 13:45 Sent To  
Notes
2019-11-13 13:47:45BUILDING IN HISTORICV DISTRICT. SAHLL RETAIN ARCH AT
 PORCH AND FRONT WINDOW SHALL BE PAIRED CASEMENT WITH
 HORIZONTAL MUNTIN OR KEEP AS SINGLE HUNG AND ADD
 VERTICAL MUNTNI OF 3" TO REPLICATE PAIR OF OF 1/1/
 SINGLE HUNGS. QUESTIONS, CONTACT: FRIEDERIKE MITTNER,
 CITY HISTORIC PRESERVATION PLANNER AT (561) 822-1457

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-20 Cont ID  
Sent By jgomez Date 2019-11-20 Time 08:26 Rev Time 0.00
Received By jgomez Date 2019-10-24 Time 11:27 Sent To  
Notes
2020-01-21 15:02:51ROUTED FROM ZONING BROUGHT DIRECTLY TO PERMIT COUNTER -
 ZONING SHOULD HAVE PASSED ON FIRST REVIEW EL
2019-11-18 16:02:18ROUTED TO HISTORIC FROM ZONING EL
2019-11-07 14:52:52ROUTED TO DESK OF SHILL PER HER REQUEST ALONG WITH
 #18100648
2019-10-28 11:28:56PLANS IN R21 RIDING WITH PERMIT #18100648 FOR WORK ON
 REAR DUPLEX. JG.
  
  
  
 11/24/19 MET WITH RONEN HAZAN (OWNER) TO COORDINATE
 PERMIT APPLICATIONS AND PLANS FOR FRONT BUILDING AND
 REAR DUPLEX. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-11-12 Cont ID  
Sent By CMONTELL Date 2019-11-12 Time 14:25 Rev Time 0.00
Received By cmontell Date 2019-11-12 Time 14:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-11-07 Cont ID  
Sent By jesmith Date 2019-11-07 Time 14:41 Rev Time 0.00
Received By jesmith Date 2019-11-07 Time 14:41 Sent To  
Notes
2019-11-07 14:41:26PLUMBING COMMENTS: APPROVED
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 SCOPE OF WORK IS LIMITED TO CHANGE OUT OF BATH AND
 KITCHEN FIXTURES ONLY

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-11-20 Cont ID  
Sent By jgomez Date 2019-11-20 Time 08:53 Rev Time 0.00
Received By jgomez Date 2019-11-20 Time 08:53 Sent To  
Notes
2019-11-20 08:54:13OWENS SHINGLES NOA 18-0215.01

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-01-15 Cont ID  
Sent By shill Date 2020-01-15 Time 13:54 Rev Time 0.00
Received By shill Date 2020-01-15 Time 13:53 Sent To  
Notes
2020-01-15 13:54:58ENGINEER CAME IN TO OFFICE AND SIGNED EACH PAGE
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-11-19 Cont ID  
Sent By shill Date 2019-11-19 Time 17:53 Rev Time 0.00
Received By shill Date 2019-11-19 Time 17:53 Sent To  
Notes
2019-11-19 17:54:30****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE PLANS SUBMITTED HAVE A PHOTOCOPY SIGNATURE.
 FS471, ORIGINAL REQUIRED. A MEETING WITH THE DESIGN
 PROFESSIONAL IS REQUESTED; HE CAN SIGN THE PLANS AT
 THAT TIME.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2020-01-21 Cont ID  
Sent By elevesqu Date 2020-01-21 Time 15:01 Rev Time 0.00
Received By elevesqu Date 2020-01-21 Time 15:01 Sent To  
Notes
2020-01-21 15:02:19PERMIT DID NOT EXCEED IMPROVEMENT VALUE - OTHER PERMIT
 FOR REAR HOUSE TRIGGERS LANDSCAPE REQUIREMENTS (PERMIT
 VALUE OVER 50% OF IMPROVEMENT VALUE) -PERMIT 18100648
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2019-11-18 Cont ID  
Sent By elevesqu Date 2019-11-18 Time 16:01 Rev Time 0.00
Received By elevesqu Date 2019-11-18 Time 15:21 Sent To  
Notes
2019-11-18 16:01:53 
 PLEASE AMEND THE ADDRESS ON THE PLANS TO REFLECT 805
 3RD STREET
  
  
 PERMITS FOR SINGLE FAMILY RESIDENCES, WHERE THE PERMIT
 VALUE IS OVER 50% OF THE IMPROVED LAND VALUE (PER
 PAPA), MUST BE ABLE TO SHOW THAT THEY ARE MEETING THE
 CRITERIA FOR LANDSCAPING FOR SINGLE FAMILY RESIDENCES.
 THIS PERMIT VALUE MEETS THIS REQUIREMENT.
 PLEASE PROVIDE THE FOLLOWING INFORMATION TO RAY
 CARANCI, LANDSCAPE PLANNER:
 PROVIDE A LIST OF THE NUMBER AND SPECIES OF TREES ON
 SITE
 PROVIDE A LIST OF THE AMOUNT (LENGTH) AND SPECIES OF
 SHRUBS ON SITE
  
 IF CURRENT LANDSCAPING DOES NOT MEET CURRENT CODE, A
 LANDSCAPE PERMIT WILL BE REQUIRED. ZONING CANNOT PASS
 PERMIT UNTIL IT IS VERIFIED THAT THE SITE MEETS
 LANDSCAPE CODE, OR UNTIL A LANDSCAPE PERMIT IS SUMITTED
 (IF NEEDED)
  
 LANDSCAPE CODE FOR SINGLE FAMILY DWELLING UNITS IS AS
 FOLLOWS:
  
 (2)GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS AND ALL OTHER DEVELOPMENTS . GENERAL
 LANDSCAPING STANDARDS FOR SINGLE-FAMILY DWELLING UNITS
 AND ALL OTHER DEVELOPMENTS SHALL BE AS
 FOLLOWS:A.SINGLE-FAMILY DWELLING UNITS . FOR
 SINGLE-FAMILY AND DUPLEX DWELLING UNITS, AT LEAST ONE
 SHADE OR FLOWERING TREE SHALL BE PLANTED FOR EACH 1,000
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. AT LEAST
 ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FRONT YARDS SHALL BE
 LANDSCAPED TO MEET THE REQUIREMENTS OF SECTION
 94-482(A).
 94-482(A): LOCATION AND SURFACE. REQUIRED OFF-STREET
 PARKING SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING
 UNITS SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE
 UNITS ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A
 FRONT YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR
 75 PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED
 WITH LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND
 COVER, SHRUBS, HEDGES, VINES OR TREES).
  
 PLEASE CONTACT RAY CARANCI AT [email protected] OR AT
 561-822-1462
  
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved