Plan Review Details - Permit 19101308
Plan Review Stops For Permit 19101308
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-29 Cont ID  
Sent By jbrooks Date 2019-10-29 Time 08:46 Rev Time 0.00
Received By jbrooks Date 2019-10-29 Time 08:46 Sent To HIST
Notes
2019-10-29 08:47:09JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561)
 805-6724
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN
 PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE
 11X17 OR SMALLER, YOU MAY RESUBMIT ALONG WITH A
 COMPLETED RESUBMITTAL FORM, VIA EMAIL TO
 [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT
 NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE
 RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE:
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 1.FBC B 107.2.1. PROVIDE REVISE FLOOR PLANS/BUILDING
 FOOT PRINT SHOWING LOCATION OF PROPOSED WINDOWS TO BE
 REPLACED AND ADD DIMENSIONS OF EACH OPENING; WINDOW
 TYPE AND ROOM DESIGNATION.
 2. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO.
 17-0918.07 HAS BEEN SUPERSEDED BY MIAMI-DADE COUNTY NOA
 NO. 19-0603.02. PLEASE PROVIDE TWO SETS. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS
 NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING. AS PER RULE 61G20-3.
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-10-29 Cont ID  
Sent By aborngra Date 2019-10-29 Time 13:33 Rev Time 0.00
Received By aborngra Date 2019-10-29 Time 12:02 Sent To PC
Notes
2019-10-29 13:33:39THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. STAFF IS UNABLE TO DETERMINE THE EXISTING CONDITION
 AND THE PROPOSED CONDITION OF EACH WINDOW OPENING.
 PLEASE PROVIDE A PHOTO OF EACH ELEVATION LABELING THE
 OPENING TO MATCH WITH THE PROPOSED ORDER FORM. FOR
 LARGE ELEVATIONS, MULTIPLE PHOTOS MAY BE USED.
 2. ALL WINDOWS WILL BE REQUIRED TO HAVE A MUNTIN
 PATTERN. A 6/1 IS VERY COMMON FOR A MISSION REVIVAL
 STRUCTURE. PROVIDE A MUNTIN DETAIL. THE EXTERNAL
 MUNTINS MUST A DIMENSIONAL OGEE PROFILE. SPECIFIC
 MUNTIN PATTERN WILL VARY DEPENDING ON THE WINDOW. STAFF
 IS UNABLE TO DETERMINE WHAT IS THE BEST WINDOW LITE
 PATTERN PER WINDOW.
 3. HORIZONTAL ROLLER WINDOWS AND FIXED WINDOWS
 (OPENINGS #19 AND #20) ARE UNLIKELY TO BE APPROVED
 BASED ON THE PERIOD OF THE STRUCTURE. STAFF RECOMMENDS
 REVISING THEM TO PAIRED CASEMENTS OR A SINGLE CASEMENT
 DEPENDING ON THE OPENING.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS THAT WILL BE
 ADDED TO THE PERMIT ONCE SUFFICIENT INFORMATION IS
 SUBMITTED. CONDITIONS ARE SUBJECT TO CHANGE PRIOR TO
 FINAL APPROVAL.
  
 A. ALL WINDOWS SHALL HAVE CLEAR GLASS OR CLEAR GLASS
 WITH LOW-E COATING. TINTED OR PRIVACY GLASS IS
 PROHIBITED.
 B. ALL WINDOWS SHALL BE SIZED TO FIT THE ORIGINAL
 WINDOW FRAME OPENING. ALL WINDOWS SHALL MATCH THE
 INSET/DEPTH OF THE ORIGINAL WINDOWS WITHIN THE WINDOW
 OPENING.
 C. THE NEW MULLION SHALL MATCH THE WIDTH OF THE
 EXISTING MULLION ON ALL WINDOWS.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-10-29 Cont ID  
Sent By jbrooks Date 2019-10-29 Time 14:15 Rev Time  
Received By cpuell Date 2019-10-24 Time 13:16 Sent To  
Notes
***NONE***