| Plan Review Stops For Permit 19101012 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-24 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-24 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2019-12-24 14:05:29 | BUILDING REVIEW APPROVED WITH PROVISO: | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS) | | | | | | 1- PROVIDE COMPLETE PRODUCT APPROVAL (2 COPIES) FOR THE | | | FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY IS | | | GOING TO BE INSTALLED. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-13 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-11-12 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2019-11-12 14:33:58 | RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | 2- EXISTING BEDROOM #1 (SAME AS PROPOSED BEDROOM #2): | | | SPECIFY THE SIZE AND TYPE OF EXISTING WINDOW AND SIZE | | | AND TYPE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE WITH | | | THE EGRESS REQUIREMENTS OF SEC. 702.5 FBC-EXISTING | | | BUILDING. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B) DOUBLE FRENCH DOORS WITH SIDELITE AS SHOWN ON PLANS. | | | | | | C) WINDOW MULLIONS AS SHOWN ON PLANS. AND REQUIRED: | | | CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY | | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | 5- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. VALUATION WAS UPDATED TO $62,196. THE | | | PERMIT FEE BALANCE IS $1365.02. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-12-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-25 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-25 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-11-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-11-19 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-11-19 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2019-11-19 11:16:07 | APPROVED WITH PROVISO ON PLAN FOR AIC CALCULATION AND | | | WIRE SIZE TO SUB-PANEL. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-12-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-12-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-11-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-11-04 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-11-04 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2019-11-04 10:50:48 | FRONT FRENCH DOOR OPEINGS TO REMAIN SAME WIDTH AS | | | EXISITNG WINDOWS. WINDWO LITE PATTERN TO REFLECT | | | EXISTING (PRIMARILY 6/1), WINDOWS FLANKING CHIMNEY TO | | | REMAIN. THESE ITEMS DISCUSSED WITH OWNER/CONTRACTOR ON | | | SITE. | | | | | | QUESTIONS/CONTACT: FRIEDERIKE MITTNER, (561) 822-1457 | | | OR [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-28 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-28 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-01-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-01-08 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2020-01-09 14:23:09 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-01-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-12-09 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-10-21 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2020-01-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-01-28 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-01-28 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2020-01-28 16:29:31 | $393.79 PAID. MU-2020-002636. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-24 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2019-12-24 14:16:31 | IMPACT FEES - | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-13 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-11-13 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2019-11-13 13:19:07 | IMPACT FEES - | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-13 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-13 |
Time |
17:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-02 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-02 |
Time |
10:32 |
Sent To |
I |
|
| Notes |
| 2020-01-02 10:35:33 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19101012 | | | 1/2/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 2ND REQUEST FOR MECHANICAL PLANS- SEE 1ST REVIEW | | | COMMENT PRINTED BELOW. | | | | | | 1) SUBMIT MECHANICAL PLANS, AND ENERGY AND AC | | | CALCULATIONS- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-11-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-11-26 |
Time |
08:23 |
Sent To |
I |
|
| Notes |
| 2019-11-26 08:32:36 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19101012 | | | 11/26/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT MECHANICAL PLANS, AND ENERGY AND AC | | | CALCULATIONS- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-24 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-11-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-11-08 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-11-07 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-12-24 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-12-24 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2019-12-24 16:02:42 | BUILDING REVIEW APPROVED WITH PROVISO: | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS) | | | | | | 1- PROVIDE COMPLETE PRODUCT APPROVAL (2 COPIES) FOR THE | | | FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY IS | | | GOING TO BE INSTALLED. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-11-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-11-13 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-11-13 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2019-11-13 13:21:28 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE | | | TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE | | | COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-12-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-12-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-11-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-11-04 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-11-04 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|