Plan Review Details - Permit 19101003
Plan Review Stops For Permit 19101003
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-07-27 Cont ID  
Sent By jgomez Date 2021-07-27 Time 16:21 Rev Time 0.00
Received By jgomez Date 2021-07-27 Time 10:42 Sent To  
Notes
2021-07-27 16:22:24RESIDENTIAL(R3) ALTERATION, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT: 19101003
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- OK
 2- OK
 3- OK
 4- OK.
 5- OK.
  
 ORIGINAL COMMENT:
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)DINING ROOM SLIDING GLASS DOORS AS SHOWN ON PLANS.
 B)EXTERIOR SWING DOOR ADJACENT TO THE NEW BATHROOM ON
 THE BACK OF THE HOUSE.
 NOTE: IT IS NOT CLEAR IF THESE DOORS ARE GOING TO BE
 REPLACED. SCOPE OF WORK AND DEMOLITION NOTES CALL FOR
 REMOVAL OF THESE DOORS. IF THESE DOORS ARE NEW, THEN
 THEY NEED THE CORRESPONDING PRODUCT APPROVAL.
 ALSO, IT IS NOT CLEAR IF THE DOOR OF THE EXTERIOR
 UTILITY CLOSET BEHIND THE MASTER BATHROOM IS NEW OR IF
 IT'S GOING TO BE REPLACED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THE ROOFING PRODUCT APPROVALS) AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 8- OK
  
 ORIGINAL COMMENT:
 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. PROVIDE COPY OF
 SIGNED CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES FOR
 BUILDING OFFICIAL REVIEW/APPROVAL.
  
 RESPONSE:
 REPEAT COMMENT (THREE TIMES). VALUED DECLARED IN THE
 NEW PERMIT APPLICATION STILL EXTREMELY TOO LOW FOR ALL
 THE SCOPE OF WORK SHOWN ON PLANS. PROVIDE A REALISTIC
 MARKET VALUE INCLUDING ALL MATERIALS, LABOR,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ENGINEER OF RECORD
 FEES OR PROVIDE COPIES OF ALL SIGNED CONTRACTS
 (INCLUDING THE SUBCONTRACTORS) CLEARLY DEPICTING ALL
 THE WORK SHOWN ON PLANS, AND COPY OF SIGNED CONTRACT
 WITH ENGINEER OF RECORD.
  
 NEW COMMENT:
 10- NONE OF THE PLANS SUBMITTED HAVE THE ENGINEER'S OF
 RECORD SEAL AND SIGNATURE. ALL PLANS NEED TO HAVE THE
 ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY 471
 F.S. WHEN SUBMITTING PLANS /DOCUMENTS FOR PUBLIC
 RECORDS.
  
 NOTE:
 PLANS CAN BE UPLOADED TO PROJECTDOX WITH DIGITAL
 SIGNATURE OR HARD COPIES WITH ENGINEER'S ORIGINAL
 SIGNATURE/SEAL MAY BE DROPPED OFF IN CITY HALL.
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 11- EXTERIOR UTILITY CLOSET:
 A)PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR THE RECONSTRUCTION OF THE EXTERIOR UTILITY CLOSET
 BEHIND THE MASTER BATHROOM. PROVIDE COMPLETE WALL
 SECTION SHOWING ALL FRAMING MEMBERS AND FASTENERS.
 PROVIDE COMPLETE INFORMATION FOR INTERIOR AND EXTERIOR
 CONSTRUCTION. SEC. R301.1 FBC-RESIDENTIAL.
  
 B) PROVIDE DOOR FRAMING DETAIL. SPECIFY ALL FRAMING
 MEMBERS AND FASTENERS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-02-28 Cont ID  
Sent By jgomez Date 2020-02-28 Time 17:33 Rev Time 0.00
Received By jgomez Date 2020-02-28 Time 15:57 Sent To  
Notes
2020-02-28 17:33:37RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 ORIGINAL COMMENT:
 1- PLANS SUBMITTED CALL FOR REMOVAL OF ENTIRE SECOND
 FLOOR AND STAIRS. NEED TO PROVIDE COMPLETE FRAMING
 PLANS, DETAILS AND SPECIFICATIONS FOR NEW ROOF. SPECIFY
 THE CURRENT CODE, WIND DESIGN CRITERIA INCLUDING THE
 ULTIMATE WIND LOAD AND NOMINAL WIND LOAD, BUILDING
 EXPOSURE, ETC. AS REQUIRED BY SEC. SEC. R301.2.1
 FBC-RESIDENTIAL AND SEC. 107.3.5.3 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 2- PLANS SUBMITTED CALL FOR A NEW LARGE SLIDING GLASS
 DOOR BY THE PROPOSED DINING AREA. NEED TO PROVIDE
 COMPLETE FRAMING PLANS, DETAILS AND SPECIFICATIONS FOR
 NEW SLIDING GLASS DOORS. ALSO, SPECIFY THE SIZE OF THE
 GLASS DOORS. SEC. R301.2.1 FBC-RESIDENTIAL AND SEC.
 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 3- PROPOSED PLANS SUBMITTED SHOW A DOOR TO BE REPLACED
 WITH A WINDOW AT THE REAR OF THE LIVING AREA. NEED TO
 PROVIDE COMPLETE FRAMING PLANS, DETAILS AND
 SPECIFICATIONS FOR NEW WINDOW. ALSO, SPECIFY THE TYPE
 AND SIZE OF THE NEW WINDOW. SEC. R301.2.1
 FBC-RESIDENTIAL AND SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 4- OK.
  
 5- OK.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
  
 ORIGINAL COMMENT:
 A) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 B) NEW WINDOWS AS SHOWN ON PLANS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 C) OK. EXISTING EXTERIOR DOOR TO REMAIN.
  
 ORIGINAL COMMENT:
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THE ROOFING PRODUCT APPROVALS) AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 8- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED
 ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8
 ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C.
 ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF
 FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT
 BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS
 117.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 NOTE: THERE IS A ROOFING PERMIT FOR THIS PROPERTY. BUT
 IS NOT CLEAR WHY THE ROOFING PERMIT WAS ISSUED BEFORE
 THE NEW ROOF IS INSTALLED. THIS NEEDS COORDINATION.
  
 ORIGINAL COMMENT:
 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. PROVIDE COPY OF
 SIGNED CONTRACTS INCLUDING DESIGN PROFESSIONAL FEES FOR
 BUILDING OFFICIAL REVIEW/APPROVAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 NEW COMMENT BASED ON NEW SET OF DRAWINGS SUBMITTED:
  
 10- SPECIFY THE SIZE OF THE NEW ATTIC ACCESS. SEC. R807
 FBC-RESIDENTIAL.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-11-13 Cont ID  
Sent By jgomez Date 2019-11-13 Time 18:07 Rev Time 0.00
Received By jgomez Date 2019-11-13 Time 13:34 Sent To P
Notes
2019-11-13 18:07:29RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1- PLANS SUBMITTED CALL FOR REMOVAL OF ENTIRE SECOND
 FLOOR AND STAIRS. NEED TO PROVIDE COMPLETE FRAMING
 PLANS, DETAILS AND SPECIFICATIONS FOR NEW ROOF. SPECIFY
 THE CURRENT CODE, WIND DESIGN CRITERIA INCLUDING THE
 ULTIMATE WIND LOAD AND NOMINAL WIND LOAD, BUILDING
 EXPOSURE, ETC. AS REQUIRED BY SEC. SEC. R301.2.1
 FBC-RESIDENTIAL AND SEC. 107.3.5.3 CITY AMENDMENTS.
  
 2- PLANS SUBMITTED CALL FOR A NEW LARGE SLIDING GLASS
 DOOR BY THE PROPOSED DINING AREA. NEED TO PROVIDE
 COMPLETE FRAMING PLANS, DETAILS AND SPECIFICATIONS FOR
 NEW SLIDING GLASS DOORS. ALSO, SPECIFY THE SIZE OF THE
 GLASS DOORS. SEC. R301.2.1 FBC-RESIDENTIAL AND SEC.
 107.2.1 CITY AMENDMENTS.
  
 3- PROPOSED PLANS SUBMITTED SHOW A DOOR TO BE REPLACED
 WITH A WINDOW AT THE REAR OF THE LIVING AREA. NEED TO
 PROVIDE COMPLETE FRAMING PLANS, DETAILS AND
 SPECIFICATIONS FOR NEW WINDOW. ALSO, SPECIFY THE TYPE
 AND SIZE OF THE NEW WINDOW. SEC. R301.2.1
 FBC-RESIDENTIAL AND SEC. 107.2.1 CITY AMENDMENTS.
  
 4- PROPOSED FLOOR PLAN DOESN'T HAVE ANY DIMENSIONS.
 PROVIDE ALL THE DIMENSIONS FOR ALL NEW AREAS. SEC.
 107.2.1 CITY AMENDMENTS.
  
 5- PROVIDE THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 B) NEW WINDOWS AS SHOWN ON PLANS.
  
 C) NEW INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 (INCLUDING THE ROOFING PRODUCT APPROVALS) AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 8- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED
 ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8
 ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C.
 ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF
 FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT
 BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS
 117.
  
 9- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. UPDATE
 VALUATION OR PROVIDE COPY OF SIGNED CONTRACTS INCLUDING
 DESIGN PROFESSIONAL FEES FOR BUILDING OFFICIAL
 REVIEW/APPROVAL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2021-07-19 Cont ID  
Sent By jleahy Date 2021-07-19 Time 17:03 Rev Time 0.00
Received By jleahy Date 2021-07-19 Time 16:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2020-02-27 Cont ID  
Sent By jpearson Date 2020-02-27 Time 10:50 Rev Time 0.00
Received By jpearson Date 2020-02-27 Time 10:50 Sent To  
Notes
2020-02-27 10:40:22CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 3. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS
 LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY
 ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS
 SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE
 CORRECTION. NEC 410.16; FBC RE E4003.12
 4. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE
 SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION OR NOTE
 FOR COMPLIANCE. NEC 410.10(D); FBC RE E4003.11
 5. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR RECEPTACLE OUTLETS. RECEPTACLES SHALL
 BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY
 ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6
 FEET FROM A RECEPTACLE OUTLET. THE WALL SPACING
 REQUIREMENTS FOR KITCHEN COUNTER SPACE STATE THAT
 RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT
 ALONG THE WALL LINE IS MORE THAN 24 INCHES MEASURED
 HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE.
 THE PLAN PROVIDED DOES NOT MEET THIS CODE IN SOME
 AREAS. PROVIDE CORRECTION. NEC 210.52(C)(1); FBC RE
 E3901
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-11-19 Cont ID  
Sent By jpearson Date 2019-11-19 Time 13:06 Rev Time 0.00
Received By jpearson Date 2019-11-19 Time 10:52 Sent To  
Notes
2019-11-19 13:06:46CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED(AND
 SEALED WHERE APPLICABLE) BY THE PERSON RESPONSIBLE FOR
 THE DESIGN. WPB FBC 107.2.1, 107.3.5; FS 471, 481
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH
 ITEM ALONG WITH THE CITY RESUBMITTAL FORM.
 ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL
 SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS.
 ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD
 REMAIN IN PACKAGE AND BE MARKED OLD SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-07-27 Cont ID  
Sent By jgomez Date 2021-07-27 Time 16:27 Rev Time 0.00
Received By jgomez Date 2021-07-16 Time 12:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-03-25 Cont ID  
Sent By ccarvaja Date 2020-03-25 Time 14:12 Rev Time 0.00
Received By ccarvaja Date 2020-02-11 Time 14:16 Sent To  
Notes
2020-02-12 14:16:34R09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-11-26 Cont ID  
Sent By ccole Date 2019-11-26 Time   Rev Time 0.00
Received By ccole Date 2019-10-28 Time 14:46 Sent To  
Notes
2019-10-29 14:46:43R05

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2021-07-19 Cont ID  
Sent By medwards Date 2021-07-19 Time 12:37 Rev Time 0.00
Received By medwards Date 2021-07-19 Time 12:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2020-02-14 Cont ID  
Sent By ccole Date 2020-02-14 Time 07:58 Rev Time 0.00
Received By ccole Date 2020-02-14 Time 07:57 Sent To  
Notes
2020-02-14 08:06:542ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19101003
 2/14/20
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE MECHANICAL PLANS SHOWING:
  
 A) DUCT ALTERATIONS FOR THE NEW FLOOR PLAN LAYOUT-
 SECTION M1601.1 FBC RES.
  
 B) NEW KITCHEN EXHAUST VENTILATION DETAILS- SECTIONS
 M1503.1 & TABLE M1507.3.3(2) FBC RES
  
 C) NEW BATH EXHAUST VENTILATION DETAILS- SECTION R303.3
 & TABLE 1507.4 FBC RES
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-11-26 Cont ID  
Sent By ccole Date 2019-11-26 Time 09:58 Rev Time 0.00
Received By ccole Date 2019-11-26 Time 08:36 Sent To I
Notes
2019-11-26 10:06:331ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19101003
 11/26/19
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A1.01: IT APPEARS BY THE SCOPE OF WORK NOTES
 THAT THE AC SYSTEM IS TO BE REPLACED. PLEASE PROVIDE
 MECHANICAL PLANS AND/OR AN AC CHANGE OUT FORM IF THE
 SCOPE IS LIMITED TO JUST CHANGING THE SYSTEM- SECION
 107.2.1 WPB. PLEASE NOTE THE CHANGE OUT FORM CAN BE
 LOCATED ON THE CITY OF WEST PALM BEACH WEBSITE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2021-07-19 Cont ID  
Sent By abelisle Date 2021-07-19 Time 12:13 Rev Time 0.00
Received By abelisle Date 2021-07-19 Time 09:18 Sent To  
Notes
2021-07-19 11:54:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 7/19/2021 19101003
  
 3RD REVIEW
 PLUMBING COMMENTS: DENIED
  
 1. THIRD REQUEST; PER WPB FBC 107.2.1, INFORMATION ON
 PLAN SHEET P-1; WATER HEATER SCHEDULE PLAN STATES
 EXISTING WATER HEATER DETAIL SHALL COMPLY WITH FBC RES
 P2801 AND P2903.4 (THERMAL EXPANSION CONTROL
 2. PER WPB FBC 107.2.1, PROVIDE NOTE REQUIRING WATER
 HAMMER ARRESTORS FOR DISHWASHER AND ICE LINE AND
 WASHING MACHINE IN ACCORDANCE WITH FBC RES P2903.5.
 3.. PER FBC PL 2017 406.2WASTE CONNECTION.
 THE WASTE FROM AN AUTOMATIC CLOTHES WASHER SHALL
 DISCHARGE THROUGH AN AIR BREAK INTO A STANDPIPE IN
 ACCORDANCE WITH SECTION 802.3.3 OR INTO A LAUNDRY SINK.
 THE TRAP AND FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER STANDPIPE SHALL BE NOT LESS THAN 2 INCHES (51
 MM) IN DIAMETER. THE FIXTURE DRAIN FOR THE STANDPIPE
 SERVING AN AUTOMATIC CLOTHES WASHER SHALL CONNECT TO A
 3-INCH (76 MM) OR LARGER DIAMETER FIXTURE BRANCH OR
 STACK. AUTOMATIC CLOTHES WASHERS THAT DISCHARGE BY
 GRAVITY SHALL BE PERMITTED TO DRAIN TO A WASTE RECEPTOR
 OR AN APPROVED TRENCH DRAIN.
 4. RE: A-1; FIXTURE SCHEDULE, FLOOR MOUNTED TUB FILLER.
 A. PER FBC RES P2713.3, PROVIDE A TEMPERATURE LIMITING
 DEVICE CONFORMING TO ASSE 1070 OR SHOW THAT THE TUB
 FILL VALVE CONFORMS TO ONE OF THE FOLLOWING; ASSE 1016,
 ASMEA112.1016 OR CSA B125.16 AS REQUIRED BY FBC RES
 P2708.4 FOR COMBINATION TUB/SHOWER CONTROL VALVES.
 B. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR CONNECTION
 OF HOT AND COLD WATER SUPPLY LINES TO THE FLOOR MOUNTED
 TUB FILLER; PROVIDE ACCESS TO THE CONNECTIONS IN THE
 CONCRETE SLAB AS REQUIRED BY FBC RES P2906.7.
 5. PER WPB FBC 107.2.1, PROVIDE SIZED SANITARY PLAN
 VIEW AND RISER DIAGRAM FOR THE ADDED SOAKING OR
 WHIRLPOOL TUB IN THE MASTER BATH. PROVIDE TRAP, VENT
 AND POINT OF CONNECTION OF FIXTURE DRAIN COMPLYING WITH
 FBC RES CHAPTERS 30,31 AND 32.
 6. PLAN SHEET P-1 THE SANITARY ISOMETRIC SHALL BE
 REVISED TO COMPLY WITH FBC PL 2017 910.- FBC PL 2017
 915
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 ATELYO BELISLE
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6695
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2020-03-10 Cont ID  
Sent By jesmith Date 2020-03-10 Time 11:51 Rev Time 0.00
Received By jesmith Date 2020-03-10 Time 08:52 Sent To  
Notes
2020-03-10 11:49:53CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
 1. SECOND REQUEST; PER WPB FBC 107.2.1, PROVIDE
 SIZE(CAPACITY) OF EXISTING WATER HEATER. PLEASE NOTE
 THAT THREE FIXTURES, A LARGE SOAKING OR WHIRLPOOL TUB,
 A SHOWER AND A LAVATORY, ALL REQUIRING HOT WATER HAVE
 BEEN ADDED TO THE PROJECT. THE INFORMATION ON PLAN
 SHEET P-1; WATER HEATER SCHEDULE PLAN STATES EXISTING
 WATER HEATER BUT PROVIDES NO DETAILS. PROVIDE AS A
 MINIMUM THAT THE EXISTING CAPACITY WILL ADEQUATELY
 SUPPORT ALL PLUMBING FIXTURES IN THE HOUSE, INCLUSIVE
 OF LAUNDRY FACILITIES. PROVIDE CALCULATIONS; REFER TO
 FBC RES P2903.6 AND TABLES P2903.6/P2903.6(1). IF
 EXISTING WATER HEATER IS NOT ADEQUATE, PROVIDE A NEW
 WATER HEATER AND SPECIFICATION/SCHEDULE. DETAIL SHALL
 COMPLY WITH FBC RES P2801 AND P2903.4 (THERMAL
 EXPANSION CONTROL). ADDITIONALLY, SHOW LOCATION ON THE
 FLOOR PLAN.
 2. A FULL BATHROOM GROUP AS WELL AS AN ADDITIONAL
 SHOWER HAS EACH BEEN ADDED TO THE PROJECT. PROVIDE AS
 MINIMUM THAT THE EXISTING WATER SERVICE WILL ADEQUATELY
 SUPPORT ALL PLUMBING FIXTURES IN THE HOUSE. PROVIDE
 CALCULATIONS; REFER TO FBC RES P2903.6 AND TABLES
 P2903.6/P2903.6(1). IF EXISTING SERVICE IS NOT
 ADEQUATE, THEN UPGRADE WATER SERVICE AND DISTRIBUTION
 TO ADEQUATELY SUPPORT ALL PLUMBING FIXTURES, INCLUDING
 THE LAUNDRY FACILITIES.
 3. PER WPB FBC 107.2.1, PROVIDE NOTE REQUIRING WATER
 HAMMER ARRESTORS FOR DISHWASHER AND ICE LINE AND
 WASHING MACHINE IN ACCORDANCE WITH FBC RES P2903.5.
 4. PER WPB FBC 107.2.1, SHOW LOCATION OF THE EXISTING
 CLOTHES WASHER AND IF APPLICABLE, THE LAUNDRY TUB.
 5. PER WPB FBC 107.2.1, PROVIDE NOTE ON PLAN REQUIRING
 NEW SHOWER/ TUB VALVES SHALL COMPLY WITH FBC RES
 P2708.4 AND P2708.5.
  
 6. RE: A-1; FIXTURE SCHEDULE, FLOOR MOUNTED TUB FILLER.
 A. PER FBC RES P2713.3, PROVIDE A TEMPERATURE LIMITING
 DEVICE CONFORMING TO ASSE 1070 OR SHOW THAT THE TUB
 FILL VALVE CONFORMS TO ONE OF THE FOLLOWING; ASSE 1016,
 ASMEA112.1016 OR CSA B125.16 AS REQUIRED BY FBC RES
 P2708.4 FOR COMBINATION TUB/SHOWER CONTROL VALVES.
 B. PROVIDE BACKFLOW PREVENTION DEVICE FOR THE HAND-HELD
 SHOWER; COMPLY WITH FBC RES P2708.5
 C. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR CONNECTION
 OF HOT AND COLD WATER SUPPLY LINES TO THE FLOOR MOUNTED
 TUB FILLER; PROVIDE ACCESS TO THE CONNECTIONS IN THE
 CONCRETE SLAB AS REQUIRED BY FBC RES P2906.7.
  
 7. PER WPB FBC 107.2.1, PROVIDE SIZED SANITARY PLAN
 VIEW AND RISER DIAGRAM FOR THE ADDED SOAKING OR
 WHIRLPOOL TUB IN THE MASTER BATH. PROVIDE TRAP, VENT
 AND POINT OF CONNECTION OF FIXTURE DRAIN COMPLYING WITH
 FBC RES CHAPTERS 30,31 AND 32.
 8. PER WPB FBC 107.2.1, PROVIDE A SLAB REPAIR DETAIL ON
 THE PLANS. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM
 THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED. SHOW
 SIZE, LENGTH, SPACING (ON CENTER), MINIMUM EMBEDMENT
 AND ANCHORING/ADHESIVE MATERIAL FOR DOWELS. THE REPAIR
 SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AS
 WELL AS THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR FINAL INSPECTION.
 9. PLAN SHEET P-1 ON ONE OF THE TWO RESUBMITTALS IS
 MISSING THE ENGINEER?S STAMP/SEAL. PLEASE WHEN
 RESUBMITTING BE SURE THAT ALL PLANS ARE SIGNED AND
 STAMPED/SEALED AS REQUIRED BY FLORIDA ADMINISTRATIVE
 CODE AND FLORIDA STATUTES
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19101003 212 GREGORY PL
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-11-14 Cont ID  
Sent By gjohnson Date 2019-11-14 Time 08:47 Rev Time 0.00
Received By gjohnson Date 2019-11-07 Time 10:04 Sent To  
Notes
2019-11-14 09:01:311ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE DIMENSIONS FOR NEW POWDER ROOM SHALL COMPLY
 WITH FBC RES P2705.1
  
 2. PROVIDE SANITARY ISOMETRICS DRAWING FOR NEW POWDER
 ROOM PER WPB AMEND TO FBC 107.3.5.3(12)
  
 3. NOTE ON PLAN IF THE SHOWER/ TUB VALES ARE EXISTING
 OR BEING REPLACED SHALL COMPLY WITH FNBC RES P2708.4 ,
 P2708.5
  
 4. NOTE ON PLAN IF WATER HEATER IS NEW OR EXISTING WHAT
 SIZE. PER FBC RES SECTION P2801
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2021-07-27 Cont ID  
Sent By jgomez Date 2021-07-27 Time 16:23 Rev Time 0.00
Received By jgomez Date 2021-07-27 Time 16:23 Sent To  
Notes
2021-07-27 16:25:12NO ROOFING REVIEW DONE. COMPLETE INFORMATION TO BE
 PROVIDED UNDER A SEPARATE PERMIT. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2020-02-28 Cont ID  
Sent By jgomez Date 2020-02-28 Time 17:34 Rev Time 0.00
Received By jgomez Date 2020-02-28 Time 17:34 Sent To  
Notes
2020-02-28 17:34:45ORIGINAL COMMENT:
 1-- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED
 ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8
 ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C.
 ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF
 FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT
 BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS
 117.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 NOTE: THERE IS A ROOFING PERMIT FOR THIS PROPERTY. BUT
 IS NOT CLEAR WHY THE ROOFING PERMIT WAS ISSUED BEFORE
 THE NEW ROOF IS INSTALLED. THIS NEEDS COORDINATION.
  
  
 ******************************************
  
 ORIGINAL REVIEW COMMENTS:
  
 1- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED
 ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8
 ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C.
 ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF
 FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT
 BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS
 117.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
 1) CERTAIN TEED NOA 15-0622.21 (FLAT ROOF)
 2) CERTAIN TEED NOA 17-1211.08 (SHINGLES)

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-11-13 Cont ID  
Sent By jgomez Date 2019-11-13 Time 18:11 Rev Time 0.00
Received By jgomez Date 2019-11-13 Time 18:07 Sent To  
Notes
2019-11-13 18:14:041- ENGINEER DOING THE RAS 117 CALCULATIONS SPECIFIED
 ONE ROW OF FASTENERS AT 4 INCHES O.C. AT THE LAP AND 8
 ROWS OF FASTENERS IN THE FIELD AT 4 INCHES O.C.
 ENGINEER TO PROVIDE SKETCH SHOWING HOW THE 9 ROWS OF
 FASTENERS ARE GOING TO BE PLACED IF FASTENERS CAN NOT
 BE PLACED LESS THAN 4 INCHES O.C. SEE SEC. 8.1 OF RAS
 117.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
 1) CERTAIN TEED NOA 15-0622.21 (FLAT ROOF)
 2) CERTAIN TEED NOA 17-1211.08 (SHINGLES)

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-07-27 Cont ID  
Sent By jgomez Date 2021-07-27 Time 16:25 Rev Time 0.00
Received By jgomez Date 2021-07-27 Time 16:25 Sent To  
Notes
2021-07-27 16:26:22SIGNATURE REVIEW COMMENTS.
  
 1- NONE OF THE PLANS SUBMITTED HAVE THE ENGINEER'S OF
 RECORD SEAL AND SIGNATURE. ALL PLANS NEED TO HAVE THE
 ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY 471
 F.S. WHEN SUBMITTING PLANS /DOCUMENTS FOR PUBLIC
 RECORDS.
  
 NOTE:
 PLANS CAN BE UPLOADED TO PROJECTDOX WITH DIGITAL
 SIGNATURE OR HARD COPIES WITH ENGINEER'S ORIGINAL
 SIGNATURE/SEAL MAY BE DROPPED OFF IN CITY HALL.
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2020-03-25 Cont ID  
Sent By rfalcone Date 2020-03-25 Time 10:10 Rev Time 0.00
Received By rfalcone Date 2020-03-25 Time 10:10 Sent To I
Notes
2020-02-28 16:23:25NEW SET OF PLANS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2019-11-04 Cont ID  
Sent By rfalcone Date 2019-11-04 Time 10:49 Rev Time 0.00
Received By rfalcone Date 2019-11-04 Time 10:49 Sent To I
Notes
2019-11-04 10:50:1611/4/19 PASSED. RF
  
 THERE ARE NO MODIFICATIONS BEING MADE TO THE EXISITING
 FOOTPRINT OF THE STRUCTURE. INTERIOR RENOVATIONS AND
 DEMOLITION OF SECOND FLOOR ONLY.