Plan Review Details - Permit 19100856
Plan Review Stops For Permit 19100856
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-12-14 Cont ID  
Sent By cthroop Date 2019-12-14 Time 11:12 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 08:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-10-19 Cont ID  
Sent By cthroop Date 2019-10-19 Time 11:30 Rev Time 0.00
Received By cthroop Date 2019-10-16 Time 15:50 Sent To  
Notes
2019-10-19 11:31:18BUILDING PLAN REVIEW
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 ADMINISTRATIVE NOTICE:
  
 A SEPERATE PERMIT NUMBER (19100856) HAS BEEN ASSIGNED
 TO THE CABANA. A VALUE OF $30,000.00 HAS BEEN ASSIGNED
 TO IT WITH A CORRESPONDING REDUCTION IN VALUE OF THE
 MAIN RESIDENCE, PERMIT NUMBER (19090792).
  
 1. AN ELEVATION CERTIFICATE IS REQUIRED. SEE COMMENTS
 UNDER THE NFIP REVIEW.
  
 2. PROVIDE A SOILS REPORT.
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 3. PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE.
 SEE COMMENTS UNDER THE IMPACT FEE REVIEW.
  
 4. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT.
 DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE
 A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR
 REVIEW.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-02-01 Cont ID  
Sent By cthroop Date 2020-02-01 Time 09:37 Rev Time 0.00
Received By cthroop Date 2020-02-01 Time 08:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-12-16 Cont ID  
Sent By cthroop Date 2019-12-16 Time 09:23 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 08:39 Sent To  
Notes
2019-12-16 09:23:48PLAN REVIEW - ELECTRICAL
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SERVICE OUTLET AT CU-1 & CU-6.
 E3901.12 HVAC OUTLET.
  
 2. AVAILABLE FAULT CURRENT FROM FPL TRANSFORMER IS
 30684. FAULT CURRENT USED ON PAGE E-5 FOR AVAILABLE
 FAULT CURRENT CALCULATIONS IS 52,205. PLEASE CORRECT.
 PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT
 AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC
 110.10 & FBC RE E3404.3
  
 3. REMOVE PANEL DP FROM RISER DIAGRAHM. PANEL DP IS TO
 BE REMOVED FROM SOW PER RESPONSE LETTER FROM DESIGNER.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. PANEL B SHOWS A TOTAL LOAD OF 119 AMPS. OVERCURRENT
 PROTECTION FROM MDP IS 100 AMPS. PLEASE CORRECT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-10-22 Cont ID  
Sent By fgiaquin Date 2019-10-22 Time 07:00 Rev Time 0.00
Received By fgiaquin Date 2019-10-22 Time 06:36 Sent To  
Notes
2019-10-22 07:00:47ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
  
 1. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET AND SWITCH
 CONTROLLED LIGHT FOR SERVICING EACH AHU LOCATED IN AN
 ATTIC. FBC MECHANICAL CODE M306.3.1
  
 2. RECEPTACLES IN OUTSIDE GRILL/PATIO AREA MUST BE GFCI
 PROTECTED. NEC 210.8A3
  
 3. SERVICE RECEPTACLE WITH GFCI PROTECTION REQUIRED
 WITHIN 25FT OF CU OUTSIDE. NEC 210.63
  
 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR PANEL P. NEC 225.31,
 225.32
  
 5. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE
 ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND
 CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF
 GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC
 RE E3607.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-02-06 Cont ID  
Sent By fmittner Date 2020-02-06 Time 15:39 Rev Time 0.00
Received By fmittner Date 2020-02-06 Time 15:39 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-12-23 Cont ID  
Sent By fmittner Date 2019-12-23 Time 11:40 Rev Time 0.00
Received By fmittner Date 2019-12-23 Time 11:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-12-24 Cont ID  
Sent By lmarchan Date 2019-12-24 Time 08:04 Rev Time 0.00
Received By lmarchan Date 2019-10-16 Time 15:50 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-02-06 Cont ID  
Sent By lmarchan Date 2020-02-06 Time 15:51 Rev Time 0.00
Received By lmarchan Date 2019-12-23 Time 09:39 Sent To  
Notes
2020-02-06 15:51:16SEE 19090792

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-10-19 Cont ID  
Sent By cthroop Date 2019-10-19 Time 11:27 Rev Time 0.00
Received By cthroop Date 2019-10-16 Time 15:50 Sent To  
Notes
2019-10-19 11:28:39PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-10-19 Cont ID  
Sent By cthroop Date 2019-10-19 Time 08:32 Rev Time 0.00
Received By cthroop Date 2019-10-16 Time 15:50 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status P Date 2020-02-03 Cont ID  
Sent By cthroop Date 2020-02-03 Time 16:26 Rev Time 0.00
Received By cthroop Date 2020-02-03 Time 16:26 Sent To  
Notes
2020-10-27 15:48:09PROVISO: A BUILDING UNDER CONSTRUCTION ELEVATION
 CERTIFICATE IS REQUIRED AT PLACEMENT OF 1ST FLOOR.
 NOTE: PROVIDE THIS EC TO CITY BUILDING INSPECTOR.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2020-02-01 Cont ID  
Sent By cthroop Date 2020-02-01 Time 08:32 Rev Time 0.00
Received By cthroop Date 2020-02-01 Time 08:32 Sent To  
Notes
2020-02-01 08:33:12PLAN REVIEW - NFIP
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SECTION C2 REQUIRES BENCHMARK UTILIZED TO BE
 DESCRIBED IN COMMENTS SECTION.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2019-12-23 Cont ID  
Sent By cthroop Date 2019-12-23 Time 09:37 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 13:42 Sent To  
Notes
2019-12-23 09:38:26PLAN REVIEW - NFIP
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SECTION C2 REQUIRES BENCHMARK UTILIZED TO BE
 DESCRIBED IN COMMENTS SECTION.
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2019-10-19 Cont ID  
Sent By cthroop Date 2019-10-19 Time 11:26 Rev Time 0.00
Received By cthroop Date 2019-10-19 Time 07:44 Sent To  
Notes
2019-10-19 11:27:02NFIP REVIEW
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 THIS PROPERTY IS LOCATED IN A FLOOD ZONE AE. AN
 ELEVATION CERTIFICATE IS REQUIRED.
  
 NFIP REVIEW
 CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16
 AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT
 AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE
 MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD
 HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM
 BEACH, FL.
 ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON
 NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM
 BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A TWO
 FOOT FREEBOARD ABOVE THE (BFE).
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 AE WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY
 OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN
 ADDITIONAL 24 INCHES OF FREEBOARD REQUIRING THE DESIGN
 FLOOD ELEVATION (DFE) TO BE 9. 0 FEET. PLEASE NOTE THIS
 INFORMATION ON YOUR PLANS.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 9 FEET NAVD.
  
 AN UNDER CONSTRUCTION (FORMBOARD) SURVEY WITH FINISHED
 FLOOR ELEVATION IS REQUIRED.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 THIS EC MAY BE SUBMITTED FOR REVIEW PRIOR TO BUILDING
 FINAL.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-02-04 Cont ID  
Sent By jesmith Date 2020-02-04 Time 10:57 Rev Time 0.00
Received By jesmith Date 2020-02-04 Time 10:55 Sent To  
Notes
2020-02-04 10:57:21PLUMBING COMMENTS: APPROVED
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 RE: PERMIT 19100856 FOR MAIN HOUSE

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-12-20 Cont ID  
Sent By cthroop Date 2019-12-20 Time 11:33 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 08:39 Sent To  
Notes
2019-12-20 11:34:18SEE PLUMBING REVIEW COMMENTS ON PERMIT 19090792. CT

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2020-01-28 Cont ID  
Sent By cthroop Date 2020-01-28 Time 11:31 Rev Time 0.00
Received By cthroop Date 2020-01-28 Time 11:30 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-12-14 Cont ID  
Sent By cthroop Date 2019-12-14 Time 11:13 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 11:13 Sent To  
Notes
2019-12-14 11:14:15BUILDING PLAN REVIEW - ROOFING
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT.
 DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE
 A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR
 REVIEW.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-10-19 Cont ID  
Sent By cthroop Date 2019-10-19 Time 11:28 Rev Time 0.00
Received By cthroop Date 2019-10-16 Time 15:50 Sent To  
Notes
2019-10-19 11:29:53BUILDING PLAN REVIEW - ROOFING
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THIS PROPERTY IS LOCATED WITHIN A HISTORIC DISTRICT.
 DEFERRAL OF PRODUCT APPROVALS AS NOTED ON PLAN PAGE
 A-0.0 ARE NOT ALLOWED. SUBMIT ALL PRODUCT APPROVALS FOR
 REVIEW.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-12-14 Cont ID  
Sent By cthroop Date 2019-12-14 Time 11:12 Rev Time 0.00
Received By cthroop Date 2019-12-14 Time 08:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-02-06 Cont ID  
Sent By fmittner Date 2020-02-06 Time 15:39 Rev Time 0.00
Received By fmittner Date 2020-02-06 Time 15:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-12-23 Cont ID  
Sent By fmittner Date 2019-12-23 Time 11:40 Rev Time 0.00
Received By fmittner Date 2019-12-23 Time 11:40 Sent To  
Notes
***NONE***