Plan Review Details - Permit 19100752
| Plan Review Stops For Permit 19100752 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-11-25 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-11-25 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-22 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-22 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2019-10-22 13:22:16 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1. THERE IS NOT ENOUGH INFORMATION IN DESCRIPTION OF | | | WORK APPLYING FOR. | | | 2. THE ADDRESS ON THE SUBMITTED PLANS IS DIFFERENT THAN | | | ON THE APPLICATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-11-25 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-11-13 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2019-11-14 16:26:18 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-22 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-22 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2019-10-21 14:11:58 | REVISION ROUTED TO PVALENTI |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-11-25 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-11-25 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-11-25 |
Time |
06:13 |
Sent To |
B |
|
| Notes |
| 2019-11-25 07:41:17 | 11/25/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | A.BELISLE | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-10-24 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2019-10-25 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2019-10-24 |
Time |
06:34 |
Sent To |
I |
|
| Notes |
| 2019-10-24 07:14:58 | 10/24/2019 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1- PLEASE SUBMIT A SPERATE PLUMBING PERMIT APPLICATION | | | FOR THE ROOF DRAINS, GREASE TRAP, ALL INTERIOR/ | | | EXTERIOR PLUMBING. PLUMBING SHALL BE DONE BY A LICENSED | | | PLUMBING CONTRACTOR. | | | | | | 2- SIGNATURE OF AN ARCHITECT-ENGINEER IS REQUIRED (OR | | | SEAL, OR TITLE BLOCK, OR ALL THREE) ARE NOT IN | | | ACCORDANCE WITH FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.001, FLORIDA STATUTE 471. | | | | | | 3- PLEASE SHOW DIMENSIONS ON THE PLAN INDICATING THE | | | BUILDINGS ACTUAL ROOF SIZE | | | | | | 4- THE ADDRESS ON THE SUBMITTED PLANS IS DIFFERENT THAN | | | THE ADDRESS LISTED ON THE PERMIT APPLICATION | | | | | | 5- INDICATE ON THE PLAN ALL ROOF DRAINS TO BE | | | INSTALLED, PLAN PAGE E 1.2 SHOWS SOME ADDITIONAL ROOF | | | DRAINS NOT SHOWN ON C-1. | | | | | | 6- PROVIDE 2-COPIES OF SPECIFICATIONS FOR THE TYPE OF | | | ROOF DRAINS THAT ARE TO BE INSTALLED | | | | | | 7- PROVIDE AN ISOMETRIC SHOWING THE ENTIRE ROOF | | | DRAINAGE SYSTEM | | | | | | 8- FLOOR DRAIN CONNECTED TO GREASE TRAP IN DUMPSTER | | | AREA SHALL NOT RECIEVE ANY RAIN WATER, HOW WILL THE | | | DUMPSTER PAD BE ELEVATED ABOVE THE SORROUNDING AREA | | | OUTSIDE OF THE DUMPSTER ? | | | | | | | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLANS EXAMINER | | | AVAILABLE BY APPOINTMENT ONLY | | | [email protected] | | | 561-805-6695 | | | |
|
|
|